Parameters
The Jeep Avenger has 486 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accelerator pedal signal 1 voltage AVENGER_ACCEL_PEDAL_SIG_1_V
- Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2023 to 2026.
Accelerator pedal signal 2 voltage AVENGER_ACCEL_PEDAL_SIG_2_V
- Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2023 to 2026.
Approximate position of turbocharger actuator AVENGER_APPROXIMATE_POS
- Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2023 to 2026.
Average cell voltage value AVENGER_AVG_CELL_V
- Service 22
DID D43D - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery average temperature AVENGER_BAT_AVG_T
- Service 22
DID D877 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2026.
Battery cell 001 voltage AVENGER_BAT_CELL_001_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 002 voltage AVENGER_BAT_CELL_002_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 003 voltage AVENGER_BAT_CELL_003_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 004 voltage AVENGER_BAT_CELL_004_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 005 voltage AVENGER_BAT_CELL_005_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 006 voltage AVENGER_BAT_CELL_006_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 007 voltage AVENGER_BAT_CELL_007_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 008 voltage AVENGER_BAT_CELL_008_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 009 voltage AVENGER_BAT_CELL_009_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 010 voltage AVENGER_BAT_CELL_010_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 011 voltage AVENGER_BAT_CELL_011_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 012 voltage AVENGER_BAT_CELL_012_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 013 voltage AVENGER_BAT_CELL_013_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 014 voltage AVENGER_BAT_CELL_014_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 015 voltage AVENGER_BAT_CELL_015_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 016 voltage AVENGER_BAT_CELL_016_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 017 voltage AVENGER_BAT_CELL_017_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 018 voltage AVENGER_BAT_CELL_018_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 019 voltage AVENGER_BAT_CELL_019_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 020 voltage AVENGER_BAT_CELL_020_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 021 voltage AVENGER_BAT_CELL_021_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 022 voltage AVENGER_BAT_CELL_022_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 023 voltage AVENGER_BAT_CELL_023_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 024 voltage AVENGER_BAT_CELL_024_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 025 voltage AVENGER_BAT_CELL_025_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 026 voltage AVENGER_BAT_CELL_026_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 027 voltage AVENGER_BAT_CELL_027_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 028 voltage AVENGER_BAT_CELL_028_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 029 voltage AVENGER_BAT_CELL_029_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 030 voltage AVENGER_BAT_CELL_030_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 031 voltage AVENGER_BAT_CELL_031_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 032 voltage AVENGER_BAT_CELL_032_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 033 voltage AVENGER_BAT_CELL_033_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 034 voltage AVENGER_BAT_CELL_034_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 035 voltage AVENGER_BAT_CELL_035_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 036 voltage AVENGER_BAT_CELL_036_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 037 voltage AVENGER_BAT_CELL_037_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 038 voltage AVENGER_BAT_CELL_038_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 039 voltage AVENGER_BAT_CELL_039_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 040 voltage AVENGER_BAT_CELL_040_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 041 voltage AVENGER_BAT_CELL_041_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 042 voltage AVENGER_BAT_CELL_042_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 043 voltage AVENGER_BAT_CELL_043_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 044 voltage AVENGER_BAT_CELL_044_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 045 voltage AVENGER_BAT_CELL_045_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 046 voltage AVENGER_BAT_CELL_046_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 047 voltage AVENGER_BAT_CELL_047_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 048 voltage AVENGER_BAT_CELL_048_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 049 voltage AVENGER_BAT_CELL_049_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 050 voltage AVENGER_BAT_CELL_050_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 051 voltage AVENGER_BAT_CELL_051_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 052 voltage AVENGER_BAT_CELL_052_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 053 voltage AVENGER_BAT_CELL_053_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 054 voltage AVENGER_BAT_CELL_054_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 055 voltage AVENGER_BAT_CELL_055_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 056 voltage AVENGER_BAT_CELL_056_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 057 voltage AVENGER_BAT_CELL_057_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 058 voltage AVENGER_BAT_CELL_058_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 059 voltage AVENGER_BAT_CELL_059_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 060 voltage AVENGER_BAT_CELL_060_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 061 voltage AVENGER_BAT_CELL_061_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 062 voltage AVENGER_BAT_CELL_062_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 063 voltage AVENGER_BAT_CELL_063_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 064 voltage AVENGER_BAT_CELL_064_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 065 voltage AVENGER_BAT_CELL_065_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 066 voltage AVENGER_BAT_CELL_066_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 067 voltage AVENGER_BAT_CELL_067_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 068 voltage AVENGER_BAT_CELL_068_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 069 voltage AVENGER_BAT_CELL_069_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 070 voltage AVENGER_BAT_CELL_070_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 071 voltage AVENGER_BAT_CELL_071_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 072 voltage AVENGER_BAT_CELL_072_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 073 voltage AVENGER_BAT_CELL_073_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 074 voltage AVENGER_BAT_CELL_074_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 075 voltage AVENGER_BAT_CELL_075_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 076 voltage AVENGER_BAT_CELL_076_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 077 voltage AVENGER_BAT_CELL_077_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 078 voltage AVENGER_BAT_CELL_078_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 079 voltage AVENGER_BAT_CELL_079_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 080 voltage AVENGER_BAT_CELL_080_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 081 voltage AVENGER_BAT_CELL_081_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 082 voltage AVENGER_BAT_CELL_082_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 083 voltage AVENGER_BAT_CELL_083_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 084 voltage AVENGER_BAT_CELL_084_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 085 voltage AVENGER_BAT_CELL_085_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 086 voltage AVENGER_BAT_CELL_086_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 087 voltage AVENGER_BAT_CELL_087_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 088 voltage AVENGER_BAT_CELL_088_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 089 voltage AVENGER_BAT_CELL_089_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 090 voltage AVENGER_BAT_CELL_090_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 091 voltage AVENGER_BAT_CELL_091_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 092 voltage AVENGER_BAT_CELL_092_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 093 voltage AVENGER_BAT_CELL_093_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 094 voltage AVENGER_BAT_CELL_094_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 095 voltage AVENGER_BAT_CELL_095_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 096 voltage AVENGER_BAT_CELL_096_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 097 voltage AVENGER_BAT_CELL_097_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,536 to 1,551 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 098 voltage AVENGER_BAT_CELL_098_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,552 to 1,567 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 099 voltage AVENGER_BAT_CELL_099_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,568 to 1,583 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 100 voltage AVENGER_BAT_CELL_100_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,584 to 1,599 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 101 voltage AVENGER_BAT_CELL_101_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,600 to 1,615 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 102 voltage AVENGER_BAT_CELL_102_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,616 to 1,631 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 103 voltage AVENGER_BAT_CELL_103_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,632 to 1,647 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 104 voltage AVENGER_BAT_CELL_104_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,648 to 1,663 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 105 voltage AVENGER_BAT_CELL_105_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,664 to 1,679 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 106 voltage AVENGER_BAT_CELL_106_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,680 to 1,695 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 107 voltage AVENGER_BAT_CELL_107_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,696 to 1,711 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 108 voltage AVENGER_BAT_CELL_108_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,712 to 1,727 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 109 voltage AVENGER_BAT_CELL_109_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,728 to 1,743 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 110 voltage AVENGER_BAT_CELL_110_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,744 to 1,759 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 111 voltage AVENGER_BAT_CELL_111_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,760 to 1,775 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 112 voltage AVENGER_BAT_CELL_112_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,776 to 1,791 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 113 voltage AVENGER_BAT_CELL_113_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,792 to 1,807 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 114 voltage AVENGER_BAT_CELL_114_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,808 to 1,823 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 115 voltage AVENGER_BAT_CELL_115_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,824 to 1,839 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 116 voltage AVENGER_BAT_CELL_116_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,840 to 1,855 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 117 voltage AVENGER_BAT_CELL_117_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,856 to 1,871 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 118 voltage AVENGER_BAT_CELL_118_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,872 to 1,887 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 119 voltage AVENGER_BAT_CELL_119_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,888 to 1,903 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery cell 120 voltage AVENGER_BAT_CELL_120_V
- Service 22
DID D440 - Module
6B4 → 694 - Every
1 s - Testing
Bits 1,904 to 1,919 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Battery current AVENGER_BAT_CURRENT
- Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2097152 to 2097151 A
- Unit
- A
In testing for 2023 to 2026.
Battery DC current AVENGER_BAT_DC_CURRENT
- Service 22
DID D816 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -1200 to 67107663 A
- Unit
- A
In testing for 2023 to 2026.
Battery insulation resistance AVENGER_BAT_INSULATION_RES
- Service 22
DID D47A - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 kΩ
- Unit
- kΩ
In testing for 2023 to 2026.
Battery max unit temperature AVENGER_BAT_MAX_UNIT_T
- Service 22
DID D817 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2026.
Battery max unit temperature number AVENGER_BAT_MAX_UNIT_T_NUMBER
- Service 22
DID D445 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2023 to 2026.
Battery min unit temperature AVENGER_BAT_MIN_UNIT_T
- Service 22
DID D87D - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2026.
Battery min unit temperature number AVENGER_BAT_MIN_UNIT_T_NUMBER
- Service 22
DID D446 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2023 to 2026.
Battery temperature AVENGER_BAT_T
- Service 22
DID D8EF - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2023 to 2026.
Cell voltage sum AVENGER_CELL_V_SUMM
- Service 22
DID D438 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2023 to 2026.
Centralized voltage maintenance device temperature limiter state AVENGER_CENTRALIZED_V_T
- Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Computer power supply voltage AVENGER_COMPUTER_POWER_SUP_V
- Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2026.
Energy accumulator discharge permission state AVENGER_ENERGY_ACCUMULATOR
- Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine control computer supply voltage AVENGER_ENG_CTRL_COMPUTER_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 V
- Unit
- V
In testing for 2023 to 2026.
Engine oil level sensor voltage AVENGER_ENG_OIL_LEVEL_SENS_V
- Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2023 to 2026.
Evaluation of the total resistance of the voltage maintaining device AVENGER_EVALUATION_TOT_RES_V
- Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 0.511
- Unit
- Number
In testing for 2023 to 2026.
High voltage battery charge AVENGER_HVBAT_SOC_RAW
Pelican can show this parameter as the state of charge.
- Service 22
DID D810 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2026.
High voltage battery charge, calibrated AVENGER_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Service 22
DID D410 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2025. Not supported for 2026.
High voltage battery health AVENGER_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Service 22
DID D860 - Module
6B4 → 694 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2023 to 2026.
High voltage battery voltage AVENGER_HVBAT_VOLT
- Service 22
DID D815 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2023 to 2026.
High voltage maximum voltage AVENGER_HVBAT_MAX_VOLT
- Service 22
DID D870 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2023 to 2026.
High voltage minimum voltage AVENGER_HVBAT_MIN_VOLT
- Service 22
DID D86F - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2023 to 2026.
Highest voltage cell number AVENGER_HIGHEST_V_CELL
- Service 22
DID D43B - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2023 to 2026.
HV battery energy AVENGER_HVBAT_KWH
Energy stored in the high voltage battery
- Service 22
DID D865 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 kWh
- Unit
- kWh
In testing for 2023 to 2026.
Lowest voltage cell number AVENGER_LOWEST_V_CELL_NUMBER
- Service 22
DID D43C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2023 to 2026.
Maximum power the battery can provide for 10 seconds AVENGER_MAX_POWER_BAT_CAN_PROVIDE_10
- Service 22
DID D873 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2023 to 2026.
Maximum power the battery can provide for 30 seconds AVENGER_MAX_POWER_BAT_CAN_PROVIDE_30
- Service 22
DID D874 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2023 to 2026.
Maximum power the battery can withstand for 10 seconds AVENGER_MAX_POWER_BAT_CAN_10
- Service 22
DID D871 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2023 to 2026.
Maximum power the battery can withstand for 30 seconds AVENGER_MAX_POWER_BAT_CAN_30
- Service 22
DID D872 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- -500 to 33551784 kW
- Unit
- kW
In testing for 2023 to 2026.
Minimum battery voltage at startup AVENGER_MIN_BAT_V_STARTUP
- Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 V
- Unit
- V
In testing for 2023 to 2026.
Reversible generator voltage AVENGER_REVERSIBLE_GEN_V
- Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 V
- Unit
- V
In testing for 2023 to 2026.
Service battery charge state AVENGER_SERVICE_BAT_CHG_ST
- Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Service battery charge status AVENGER_SERVICE_BAT_CHG_STAT
- Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2023 to 2026.
Service battery temperature AVENGER_SERVICE_BAT_T
- Service 22
DID D496 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Service battery temperature AVENGER_SERVICE_BAT_T_6A8
- Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2023 to 2026.
Service battery voltage AVENGER_SERVICE_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2023 to 2026.
Service battery wear condition AVENGER_SERVICE_BAT_WEAR
- Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Service cell voltage value AVENGER_SERVICE_CELL_V
- Service 22
DID D822 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2023 to 2026.
Set voltage of energy storage AVENGER_SET_V_ENERGY_STORAGE
- Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2023 to 2026.
Set voltage of storage battery charging AVENGER_SET_V_STORAGE_BAT
- Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 V
- Unit
- V
In testing for 2023 to 2026.
Set voltage of the reversible generator AVENGER_SET_V_REVERSIBLE_GEN
- Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2023 to 2026.
Stop permitted by voltage maintainer computer AVENGER_STOP_PERMITTED_V
- Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Temperature of the electronic power unit of the voltage maintenance device AVENGER_T_ELECTRONIC_POWER_V
- Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2023 to 2026.
Turbocharger control duty cycle AVENGER_TURBOCHARGER_CTRL
- Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -128 to 127 %
- Unit
- %
In testing for 2023 to 2026.
Turbocharger first electronic boost AVENGER_TURBOCHARGER_FIRST
- Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Turbocharger position information AVENGER_TURBOCHARGER_POS
- Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2023 to 2026.
Turbocharger pressure measured AVENGER_TURBOCHARGER_P_MEAS
- Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2023 to 2026.
Turbocharger pressure reference AVENGER_TURBOCHARGER_P
- Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2023 to 2026.
Turbocharger, target position AVENGER_TURBOCHARGER_TGT_POS
- Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Voltage at the terminals of the energy accumulator AVENGER_V_TERMINALS_ENERGY
- Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2023 to 2026.
Voltage maintainer computer request sent AVENGER_V_MAINTAINER_COMPUTER_REQ
- Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Voltage maintainer computer restart permission AVENGER_V_MAINTAINER
- Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Voltage maintainer status AVENGER_V_MAINTAINER_STAT
- Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Control
Anti-lock brake or stability control regulating AVENGER_ABS_EKS_PROCESS_ADJ
- Service 22
DID D474 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Brake circuit pressure AVENGER_BRAKE_CIRCUIT_P
- Service 22
DID D70E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -55 to 6498 bar
- Unit
- bar
In testing for 2023 to 2026.
Brake system backup contactor status AVENGER_BRAKE_SYSTEM_BACKUP
- Service 22
DID D463 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Main brake contactor status AVENGER_MAIN_BRAKE_CONTACTOR
- Service 22
DID D513 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Secondary brake contactor status AVENGER_SECONDARY_BRAKE
- Service 22
DID D514 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Vacuum present in the brake system AVENGER_VACUUM_PRESENT_BRAKE
- Service 22
DID D700 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine
5V power supply state number 1 AVENGER_5V_POWER_SUP_ST_1
- Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
5V power supply state number 2 AVENGER_5V_POWER_SUP_ST_2
- Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
5V power supply state number 3 AVENGER_5V_POWER_SUP_ST_3
- Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
5V power supply state number 4 AVENGER_5V_POWER_SUP_ST_4
- Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
12V network allowed stop AVENGER_12V_NETWORK_ALLOWED
- Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Activation count, brake electromagnetic valve B1 AVENGER_NUM_ACTIVATIONS_B1
- Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, line pressure control solenoid AVENGER_NUM_LINE_P_CTRL
- Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, the electromagnetic valve of brake B2 AVENGER_NUM_ACTIVATIONS_B2
- Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Actual oil pressure AVENGER_ACT_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2023 to 2026.
Additional heater control 1 AVENGER_ADDITIONAL_HEATER_1
- Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Air conditioning AVENGER_AC
- Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Air conditioning compressor current AVENGER_AC_COMP_CURRENT
- Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6375
- Unit
- Number
In testing for 2023 to 2026.
Air conditioning high side pressure AVENGER_AC_HIGH_SIDE_P
- Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2023 to 2026.
Air conditioning pressure AVENGER_AC_P
- Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2023 to 2026.
Air doser first electronic loading AVENGER_AIR_DOSER_FIRST
- Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Air flow AVENGER_AIR_FLOW
- Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2023 to 2026.
Air flow target AVENGER_AIR_FLOW_TGT
- Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2023 to 2026.
Air metering valve duty cycle AVENGER_AIR_METERING_VLV
- Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Air metering valve position AVENGER_AIR_METERING_VLV_POS
- Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Air metering valve, target position AVENGER_AIR_METERING_VLV_TGT
- Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Air temperature by air flow meter AVENGER_AIR_T_AIR_FLOW_METER
- Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Alternator load value AVENGER_ALTERNATOR_LOAD
- Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Ambient air temperature AVENGER_AAT_6A9
- Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2023 to 2026.
ANTI START PROGRAMMING STATUS AVENGER_ANTI_START
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Atmospheric pressure AVENGER_ATMOSPHERIC_P
- Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2023 to 2026.
Automatic restart request from body control module AVENGER_AUTOMATIC_RESTART_REQ_BSI
- Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic restart request from engine management computer AVENGER_AUTOMATIC_RESTART
- Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic stop allowed by body control module AVENGER_AUTOMATIC_STOP
- Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic stop allowed by power steering computer AVENGER_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Auxiliary heater 2 control AVENGER_AUXILIARY_HEATER_2
- Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Average mileage for the last 10 regenerations AVENGER_AVG_MILEAGE_LAST_10
- Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2023 to 2026.
Boost air temperature AVENGER_BOOST_AIR_T
- Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Button state AVENGER_BUTTON_ST
- Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Camshaft/crankshaft position synchronization AVENGER_CAM_CRANK_POS
- Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
CHANGE REPORT IN PROGRESS AVENGER_CHANGE_REPORT
- Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Combustion engine state AVENGER_ICE_ST
- Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Commanded oil pressure AVENGER_CMD_OIL_P
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2023 to 2026.
Computer lock AVENGER_COMPUTER_LOCK
- Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Computer remote wake-up state AVENGER_COMPUTER_WAKE_UP_ST
- Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Computer restarts since memory erase AVENGER_CNT_NUM_RE
- Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
Computer temperature AVENGER_COMPUTER_T
- Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Control current of electromagnetic valve for changing the pressure in the brake system B2 AVENGER_CTRL_CURRENT_P_B2
- Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 AVENGER_CTRL_CURRENT_P_B1
- Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Controlled air supply module AVENGER_CONTROLLED_AIR_SUP
- Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Coolant temperature AVENGER_ECT
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2023 to 2026.
Coolant temperature AVENGER_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Coolant temperature target AVENGER_ECT_TGT
- Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Coolant temperature, corrected AVENGER_ECT_CORRECTED
- Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Cruise control, RW status AVENGER_CRUISE_CTRL_RW_STAT
- Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Cylinder 1 injector flow correction AVENGER_CYL_1_INJ_FLOW_CORR
- Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2023 to 2026.
Cylinder 2 injector flow correction AVENGER_CYL_2_INJ_FLOW_CORR
- Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2023 to 2026.
Cylinder 3 injector flow correction AVENGER_CYL_3_INJ_FLOW_CORR
- Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2023 to 2026.
Cylinder 4 injector flow correction AVENGER_CYL_4_INJ_FLOW_CORR
- Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2023 to 2026.
Date AVENGER_DATE
- Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2023 to 2026.
Drive motor power AVENGER_DRIVE_MOTOR_POWER
- Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 W
- Unit
- W
In testing for 2023 to 2026.
Drive motor stator temperature AVENGER_DRIVE_MOTOR_STATOR_T
- Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Drive motor torque, actual AVENGER_DRIVE_MOTOR_TQ_ACT
- Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Drive motor torque, desired AVENGER_DRIVE_MOTOR_TQ_DES
- Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Driver presence AVENGER_DRIVER_PRESENCE
- Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Driver, requested torque value AVENGER_DRIVER_REQ_TQ
- Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Economy mode off state AVENGER_ECO_MODE_OFF_ST
- Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Electric cooling fan control AVENGER_GMV_ELEC_COOLING_FAN
- Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Electric machine torque AVENGER_ELEC_MACHINE_TQ
- Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1638 to 4915 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Electric machine torque reduction AVENGER_ELEC_MACHINE_TQ_REDUCTION
- Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Energy accumulator state transfer AVENGER_ENERGY_ACCUMULATOR_ST
- Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Energy accumulator temperature limiter state AVENGER_ENERGY_ACCUMULATOR_T
- Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine control module status AVENGER_ENG_CTRL_MODULE_STAT
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine coolant temperature AVENGER_ECT_6A9
- Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2026.
Engine oil dilution protection status AVENGER_ENG_OIL_DILUTION
- Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine operating mode AVENGER_ENG_OP_MODE
- Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Engine restart counter AVENGER_ENG_RESTART_CNT
- Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Engine restart counter by stop and start function AVENGER_ENG_RESTART_CNT_STOP
- Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Engine restart request sent by ESP computer AVENGER_ENG_RESTART_REQ_SENT
- Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine stalls AVENGER_ENG_STALLS
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine start prohibition control, start lock AVENGER_ENG_START
- Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engine stop time AVENGER_ENG_STOP_TIME
- Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2023 to 2026.
Engine torque AVENGER_ENG_TQ
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Estimated torque of internal friction of the engine AVENGER_ESTIMATED_TQ
- Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Evaluation of carbon content in engine oil AVENGER_EVALUATION_CARBON
- Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7.96 %
- Unit
- %
In testing for 2023 to 2026.
Evaluation of the degree of dilution of motor oil AVENGER_EVALUATION_DEGREE
- Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2023 to 2026.
Exhaust gas recirculation high limit electronic loading AVENGER_EGR_HIGH_LIM
- Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Exhaust gas recirculation low limit electronic loading AVENGER_EGR_LOW_LIM
- Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Exhaust gas recirculation valve duty cycle AVENGER_EGR_VLV_CTRL_SIG_RCO
- Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Exhaust gas recirculation valve first electronic loading AVENGER_EGR_VLV_FIRST
- Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Exhaust gas recirculation valve position AVENGER_EGR_VLV_POS
- Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Exhaust gas recirculation valve set position AVENGER_EGR_VLV_SET_POS
- Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Expected generator supplier identifier of the reversible generator AVENGER_EXPECTED_GEN
- Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Expected identifier of electronic power circuit of reversible generator generator AVENGER_EXPECTED_IDENTIFIER_ELECTRONIC
- Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Expected identifier of reversible generator AVENGER_EXPECTED_IDENTIFIER
- Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
FUGITIVE TRIP IN EMERGENCY MODE AVENGER_FUGITIVE_TRIP
- Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Generator mode AVENGER_GEN_MODE
- Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Generator shutdown AVENGER_GEN_SHUTDOWN
- Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Identifier of the electronic power circuit of the reversible generator AVENGER_IDENTIFIER
- Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Identifier of the supplier of the reversible generator AVENGER_IDENTIFIER_SUPPLIER
- Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Immobilizer code programming status AVENGER_IMMOBILIZER_CODE
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Indicated engine torque AVENGER_INDICATED_ENG_TQ
- Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Injector code 1 AVENGER_INJ_CODE_1
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2023 to 2026.
Injector code 2 AVENGER_INJ_CODE_2
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2023 to 2026.
Injector code 3 AVENGER_INJ_CODE_3
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2023 to 2026.
Injector code 4 AVENGER_INJ_CODE_4
- Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2023 to 2026.
Line pressure solenoid valve control current AVENGER_SLT_LINE_P_VARIATION
- Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Lock status AVENGER_LOCK_STAT
- Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Long-term regeneration capability AVENGER_LONG_TERM_REGEN
- Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Maximum allowable torque AVENGER_MAX_ALLOWABLE_TQ
- Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 AVENGER_MEAS_CURRENT_P_B2
- Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 AVENGER_MEAS_CURRENT_P_B1
- Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured line pressure variation solenoid valve current AVENGER_MEAS_LINE_P
- Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Mileage since last oil change AVENGER_MILEAGE_SINCE_OIL
- Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2023 to 2026.
Minimum cell capacity AVENGER_MIN_CELL_CAP
- Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2023 to 2026.
Movement of controlled air supply module AVENGER_MOVEMENT_CONTROLLED
- Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Neutral position sensor status AVENGER_NEUTRAL_POS_SENS
- Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Number of engine stop information deletion cycles AVENGER_NUM_ENG_STOP
- Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Oil pressure AVENGER_OIL_P
- Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2023 to 2026.
Oil pressure reference value AVENGER_OIL_P_REFERENCE
- Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2023 to 2026.
Oil pressure regulation control AVENGER_OIL_P_REGULATION
- Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 %
- Unit
- %
In testing for 2023 to 2026.
Oil temperature AVENGER_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Outside air temperature AVENGER_AAT_6A8
- Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Powertrain condition AVENGER_POWERTRAIN_COND
- Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Preheating relay control AVENGER_PREHEATING_RELAY
- Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Presence of the identifier of the reversible generator AVENGER_PRESENCE_IDENTIFIER
- Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Problems detected while transmitting unlock code AVENGER_PROBLEMS_DETECTED
- Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Problems detected while transmitting unlock code AVENGER_PROBLEMS_DETECTED_WHILE
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Real engine torque AVENGER_REAL_ENG_TQ
- Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Regeneration enable AVENGER_REGEN_ENABLE
- Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Remote wake-up circuit status AVENGER_REMOTE_WAKE_UP
- Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Remote wake-up state AVENGER_REMOTE_WAKE_UP_ST
- Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Request to turn on the engine diagnostic indicator AVENGER_REQ_TURN_ON_ENG
- Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Requested value controlled thermostat AVENGER_REQ_CONTROLLED
- Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2023 to 2026.
Restart request sent by power steering computer AVENGER_RESTART_REQ_SENT
- Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Restart request sent by suspension computer AVENGER_RESTART_REQ_SENT_SUSPENSION
- Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Return to engine start and restart control by starter AVENGER_RETURN_ENG_START
- Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Return to starter engine restart control AVENGER_RETURN_STARTER_ENG
- Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Reverse generator status AVENGER_REVERSE_GEN_STAT
- Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Reversible generator torque AVENGER_REVERSIBLE_GEN_TQ
- Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Service network related engine restart request AVENGER_SERVICE_NETWORK
- Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Short-term regeneration capability AVENGER_SHORT_TERM_REGEN
- Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Sport mode contactor state AVENGER_SPORT_MODE_CONTACTOR
- Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Start inhibit control, wired AVENGER_START_INHIBIT_CTRL
- Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Start or restart inhibition transmitted by engine management computer AVENGER_START_OR_RESTART
- Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Start prohibition AVENGER_START_PROHIBITION
- Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Starter activation counter AVENGER_STARTER_ACTIVATION
- Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Starter control interface unit operating status AVENGER_STARTER_CTRL
- Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Starter duty cycle AVENGER_STARTER_DUTY
- Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2023 to 2026.
Starter engagement status AVENGER_STARTER_ENGAGEMENT
- Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
State lock/unlock control unit AVENGER_ST_LOCK_UNLOCK_CTRL
- Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Status of internal ignition motor AVENGER_STAT_INTERNAL_IGN
- Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Status of the energy accumulator AVENGER_STAT_ENERGY
- Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Stop allowed by ESP computer AVENGER_STOP_ALLOWED_ESP
- Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Stop and start function state AVENGER_STOP_START_FUNCTION
- Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Stop and start switch AVENGER_STOP_START_SWITCH
- Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Stop permitted by suspension computer AVENGER_STOP_PERMITTED
- Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Temperature difference between the hottest and the coolest cells AVENGER_T_DIFF_HOTEST
- Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2023 to 2026.
Temperature of the energy accumulator AVENGER_T_ENERGY_ACCUMULATOR
- Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2023 to 2026.
The composition of the mixture is calculated by the oxygen sensor AVENGER_COMPOSITION_MIXTURE
- Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2023 to 2026.
Torque corresponding to driver requirement AVENGER_TQ_CORRESPONDING
- Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Torque supplied or taken by generator AVENGER_TQ_SUPPLIED_OR_TAKEN
- Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Total mileage AVENGER_ODO_6A8
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2023 to 2026.
Towing device configured AVENGER_CAN_VEH_BE_EQUIPPED
- Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Traction circuit coolant temperature AVENGER_TRACTION_CIRCUIT_ECT
- Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2023 to 2026.
Traction or stability control regulating AVENGER_ASR_OR_ESP_SYSTEM
- Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Transmission fluid temperature AVENGER_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2023 to 2026.
Vacuum circuit vacuum AVENGER_VACUUM_CIRCUIT
- Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2023 to 2026.
Value during generator load smooth increase AVENGER_DURING_GEN_LOAD
- Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Vehicle hour meter AVENGER_VEH_HOUR_METER
- Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2023 to 2026.
Vehicle mileage since the last oil change under severe vehicle operating conditions AVENGER_VEH_MILEAGE_SINCE
- Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2023 to 2026.
Winter mode switch state AVENGER_WINTER_MODE_SWITCH
- Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Fuel
Amount of fuel additive remaining in the additive tank AVENGER_AMOUNT_FUEL_ADDITIVE
- Service 22
DID D56C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2023 to 2026.
Calculated fuel injection amount AVENGER_CALC_FUEL_INJ_AMOUNT
- Service 22
DID D563 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2023 to 2026.
Desired high pressure common rail fuel pressure AVENGER_DES_HIGH_P_COMMON_P
- Service 22
DID D445 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 bar
- Unit
- bar
In testing for 2023 to 2026.
First fuel additive injection state AVENGER_FIRST_FUEL_ADDITIVE
- Service 22
DID D56F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Fuel pressure AVENGER_FUEL_P
- Service 22
DID D41F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2023 to 2026.
Fuel temperature AVENGER_FUEL_T
- Service 22
DID D42A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2023 to 2026.
High fuel pressure measured AVENGER_HIGH_FUEL_P_MEAS
- Service 22
DID D446 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 2023 to 2026.
Injection angle of the high-pressure fuel pump AVENGER_INJ_ANG_HIGH_P_FUEL
- Service 22
DID D588 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2023 to 2026.
Low pressure fuel pump actuator duty cycle AVENGER_LOW_P_FUEL_PMP
- Service 22
DID D472 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2023 to 2026.
Low pressure fuel pump status AVENGER_LOW_P_FUEL_PMP_STAT
- Service 22
DID D4ED - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Minimum fuel level AVENGER_MIN_FLI
- Service 22
DID D56A - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Movement
Accelerator pedal position AVENGER_ACCEL_PEDAL_POS
- Service 22
DID D407 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position AVENGER_ACCEL_PEDAL_POS_6A9
- Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.45 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position AVENGER_ACCEL_PEDAL_POS_6A9_6A9
- Service 22
DID D505 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position AVENGER_ACCEL_PEDAL_POS_6B4
- Service 22
DID D407 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position, recalculated AVENGER_ACCEL_PEDAL_POS_RECALCULATED
- Service 22
DID D407 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position, track 1 AVENGER_ACCEL_PEDAL_POS_1
- Service 22
DID D491 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2023 to 2026.
Accelerator pedal position, track 2 AVENGER_ACCEL_PEDAL_POS_2
- Service 22
DID D492 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399 to 399 %
- Unit
- %
In testing for 2023 to 2026.
Clutch release state at stop, creep speed reduction AVENGER_CLU_RELEASE_ST_STOP
- Service 22
DID D672 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Crankshaft speed AVENGER_CRANK_SPD
- Service 22
DID D462 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Crankshaft speed determined by camshaft sensor AVENGER_CRANK_SPD_DETERMINED
- Service 22
DID D499 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Cruise control set speed AVENGER_CRUISE_CTRL_SET_SPD
- Service 22
DID D475 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Engine RPM AVENGER_RPM
Pelican can show this parameter as the engine speed.
- Service 22
DID D400 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Engine RPM AVENGER_RPM_6A9
Pelican can show this parameter as the engine speed.
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Input shaft speed AVENGER_INPUT_SHFT_SPD
- Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Set speed of electric cooling fan AVENGER_SET_SPD_ELEC_COOLING
- Service 22
DID D4AA - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
STATUS COMMANDS REGULATION OR LIMITATION SPEED AVENGER_STAT_COMMANDS
- Service 22
DID D704 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Torque converter slip speed, measured AVENGER_TQ_CONV_SLIP_SPD
- Service 22
DID D654 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Vehicle speed AVENGER_VSS_6A8
Pelican can show this parameter as the speed.
- Service 22
DID D402 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Vehicle speed AVENGER_VSS_6A9
Pelican can show this parameter as the speed.
- Service 21
PID C8 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Vehicle speed AVENGER_VSS_6A9_6A9
Pelican can show this parameter as the speed.
- Service 22
DID D711 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Vehicle speed AVENGER_VSS_6B4
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6B4 → 694 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4194368 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Vehicle speed limiter set speed AVENGER_VSS_LIMITER_SET_SPD
- Service 22
DID D476 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Vehicle speed limiter status, LW AVENGER_VSS_LIMITER_STAT_LW
- Service 22
DID D4C0 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Vehicle speed, ESP AVENGER_VSS_ESP
Pelican can show this parameter as the speed.
- Service 22
DID D802 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Tires
Average front wheel speed AVENGER_AVG_FRONT_WHL_SPD
- Service 22
DID D530 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2621 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Average speed front wheels AVENGER_AVG_SPD_FRONT_WHEELS
- Service 22
DID D533 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Counter of occurrence of enhanced resonance of the twin flywheel of the engine AVENGER_CNT_OCCURRENCE
- Service 22
DID D4E4 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
Counter of occurrence of resonance of the twin flywheel of the engine AVENGER_CNT_OCCURRENCE_RESONANCE
- Service 22
DID D4E5 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2023 to 2026.
Rear left wheel speed AVENGER_RL_WHL_SPD
- Service 22
DID D531 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Rear right wheel speed AVENGER_RR_WHL_SPD
- Service 22
DID D532 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2023 to 2026.
Transmission
Activation count, additional oil pump, ATN8 gearbox AVENGER_NUM_ADDITIONAL_OIL
- Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, clutch electromagnetic valve C2 AVENGER_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2
- Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, clutch electromagnetic valve C3 AVENGER_NUM_ACTIVATIONS_CLU_C3
- Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, clutch protection C1 AVENGER_NUM_ACTIVATIONS_CLU_C1
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Activation count, clutch protection C2 AVENGER_NUM_ACTIVATIONS_CLU_C2
- Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Activation count, gear 7 AVENGER_NUM_ACTIVATIONS_GEAR_7
- Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, shift solenoid SC2 AVENGER_NUM_SHIFT_SOLENOID
- Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, shift solenoid SC3 AVENGER_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p AVENGER_NUM_ACTIVATIONS_P
- Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, the electromagnetic valve of clutch C4 AVENGER_NUM_ACTIVATIONS_C4
- Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, the electromagnetic valve of the clutch C1 AVENGER_NUM_ACTIVATIONS_C1
- Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation count, torque converter lockup electromagnetic valve AVENGER_NUM_ACTIVATIONS_TQ
- Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Activation of additional oil pump, ATN8 gearbox AVENGER_ACTIVATION
- Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2023 to 2026.
Additional oil pump control status, atn8 transmission AVENGER_ADDITIONAL_OIL_PMP
- Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic restart request from transmission computer AVENGER_AUTOMATIC_RESTART_REQ
- Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic stop allowed by gearbox computer AVENGER_AUTOMATIC_STOP_ALLOWED
- Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission fluid temperature AVENGER_AUTOMATIC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2023 to 2026.
Automatic transmission in emergency mode AVENGER_AUTOMATIC_TRANS_EMERGENCY
- Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission in park position AVENGER_AUTOMATIC_TRANS_PARK
- Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission input shaft mode, calculated AVENGER_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Automatic transmission input shaft mode, measured AVENGER_AUTOMATIC_TRANS_INPUT_SHFT
- Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Automatic transmission lubrication solenoid control current AVENGER_AUTOMATIC_TRANS_LUBRICATION
- Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission oil aging sensor AVENGER_AUTOMATIC_TRANS_OIL
- Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission oil drain AVENGER_DRAIN_TRANS
- Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission output shaft mode, calculated AVENGER_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Automatic transmission output shaft mode, measured AVENGER_AUTOMATIC_TRANS_OUTPUT
- Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Automatic transmission overheat indicator request AVENGER_AUTOMATIC_TRANS
- Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Automatic transmission torque request AVENGER_AUTOMATIC_TRANS_TQ
- Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2023 to 2026.
Calculated gear in gearbox AVENGER_CALC_GEAR_GEARBOX
- Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Clutch pedal AVENGER_CLU_PEDAL
- Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Clutch pedal position value AVENGER_CLU_PEDAL_POS
- Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2023 to 2026.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox AVENGER_CTRL_CURRENT_P_P
- Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p AVENGER_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Control current of electromagnetic valve of change of pressure of torque converter lock-up AVENGER_CTRL_CURRENT_P
- Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Control current of the electromagnetic valve for changing the gear shift SC2 AVENGER_CTRL_CURRENT
- Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Control current of the electromagnetic valve of change of pressure of clutch C3 AVENGER_CTRL_CURRENT_P_C3
- Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Control current of the electromagnetic valve of change of pressure of clutch C4 AVENGER_CTRL_CURRENT_P_C4
- Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Control current of the solenoid valve for changing the pressure of the clutch C1 AVENGER_CTRL_CURRENT_P_C1
- Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Control current of the solenoid valve for changing the pressure of the clutch C2 AVENGER_CTRL_CURRENT_P_C2
- Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
DC-DC converter temperature AVENGER_DC_DC_CONV_T
- Service 22
DID D8CE - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2023 to 2026.
Engaged gear AVENGER_ENGAGED_GEAR
- Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Engaged gear AVENGER_ENGAGED_GEAR_6A9
- Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Exhaust gas temperature after upstream catalytic converter AVENGER_EXH_GAS_T_AFTER_PRE
- Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Exhaust gas temperature before upstream catalytic converter AVENGER_EXH_GAS_T_BEFORE_PRE
- Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2023 to 2026.
Gear in the process of engaging AVENGER_GEAR_PROCESS
- Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Gear shift knob under steering wheel AVENGER_GEAR_SHIFT_KNOB
- Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Gear shift lever position displayed on instrument panel AVENGER_GEAR_SHIFT_LEVER_POS_ON
- Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Maximum clutch travel during gear shift AVENGER_MAX_CLU_TRAVEL
- Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2023 to 2026.
Measured current of control of electromagnetic valve of automatic transmission lubrication AVENGER_MEAS_CURRENT_CTRL
- Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up AVENGER_MEAS_CURRENT_CTRL_P
- Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Measured current of the electromagnetic valve for changing the gear shift SC2 AVENGER_MEAS_CURRENT
- Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox AVENGER_MEAS_CURRENT_P_P
- Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Measured current of the electromagnetic valve of change of pressure of clutch C3 AVENGER_MEAS_CURRENT_P_C3
- Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the electromagnetic valve of change of pressure of clutch C4 AVENGER_MEAS_CURRENT_P_C4
- Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the solenoid valve for changing the pressure of the clutch C1 AVENGER_MEAS_CURRENT_P_C1
- Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the solenoid valve for changing the pressure of the clutch C2 AVENGER_MEAS_CURRENT_P_C2
- Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p AVENGER_MEAS_CURRENT_P
- Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Nitrogen oxide content after catalytic converter, ppm AVENGER_NOX_CONTENT_AFTER
- Service 22
DID D53D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2023 to 2026.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm AVENGER_NOX_CONTENT_MEAS
- Service 22
DID D545 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2023 to 2026.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm AVENGER_NOX_CONTENT_MEAS_INLET_NOX
- Service 22
DID D576 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Number
In testing for 2023 to 2026.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox AVENGER_NUM_ENGAGEMENTS_P_P
- Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 1 AVENGER_NUM_GEAR_ENGAGEMENTS_1
- Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 2 AVENGER_NUM_GEAR_ENGAGEMENTS_2
- Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 3 AVENGER_NUM_GEAR_ENGAGEMENTS_3
- Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 4 AVENGER_NUM_GEAR_ENGAGEMENTS_4
- Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 5 AVENGER_NUM_GEAR_ENGAGEMENTS_5
- Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 6 AVENGER_NUM_GEAR_ENGAGEMENTS_6
- Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements 8 AVENGER_NUM_GEAR_ENGAGEMENTS_8
- Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements n AVENGER_NUM_GEAR_ENGAGEMENTS_N
- Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of gear engagements right AVENGER_NUM_GEAR_ENGAGEMENTS
- Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of shift solenoid operated automatic transmission lubrication control valve AVENGER_NUM_SHIFT_SOLENOID_OPERATED
- Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of shift solenoid operated SC4 AVENGER_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of shift solenoid operated SC5 AVENGER_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Number of shift solenoid operated torque converter lock-up pressure regulating valve AVENGER_NUM_SHIFT_SOLENOID_P
- Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2023 to 2026.
Operating mode used by the automatic transmission AVENGER_OP_MODE_USED
- Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Position of the gearshift lever AVENGER_POS_GEARSHIFT_LEVER
- Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Proportional clutch pedal sensor AVENGER_PROPORTIONAL_CLU
- Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Reverse gear contactor status AVENGER_REVERSE_GEAR
- Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
SC5 shift solenoid control current AVENGER_SC5_SHIFT_SOLENOID
- Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
SC5 shift solenoid measured current AVENGER_SC5_SHIFT_SOLENOID_MEAS
- Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Shift solenoid control current SC3 AVENGER_SHIFT_SOLENOID_CTRL
- Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Shift solenoid control current SC4 AVENGER_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Shift solenoid measured current SC3 AVENGER_SHIFT_SOLENOID_MEAS
- Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Shift solenoid measured current SC4 AVENGER_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Shift-lock control AVENGER_SHIFT_LOCK_CTRL
- Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Start permission from gearbox computer AVENGER_START_PERMISSION
- Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Torque converter lock-up pressure variation solenoid valve control current AVENGER_TQ_CONV_LOCK_UP_P
- Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Torque converter lock-up pressure variation solenoid valve control current AVENGER_TQ_CONV_LOCK_UP_P_VARIATION
- Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2023 to 2026.
Torque converter slip mode, theoretical value AVENGER_TQ_CONV_SLIP_MODE
- Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2023 to 2026.
Torque converter status AVENGER_TQ_CONV_STAT
- Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2023 to 2026.
Upstream catalytic converter aging AVENGER_PRE_CATALYTIC_CONV
- Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2023 to 2026.
Trips
Distance to next oil change AVENGER_DIST_NEXT_OIL_CHANGE
- Service 22
DID D536 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2023 to 2026.
Distance traveled since the last regeneration AVENGER_DIST_TRAVELED_SINCE
- Service 22
DID D519 - Module
6A8 → 688 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4095 km
- Unit
- km
In testing for 2023 to 2026.
Odometer AVENGER_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2023 to 2026.
Odometer AVENGER_ODO_6A2
Pelican can show this parameter as the odometer.
- Service 22
DID D49C - Module
6A2 → 682 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2023 to 2026.
Odometer AVENGER_ODO_6A9
Pelican can show this parameter as the odometer.
- Service 22
DID D802 - Module
6A9 → 689 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2023 to 2026.