INFINITI QX70

Parameters

The INFINITI QX70 has 79 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Manifold pressure sensor voltage QX70_MANIFOLD_P_SENS_V

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2003 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Manifold pressure sensor voltage QX70_MANIFOLD_P_SENS_V

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2003 to 2017.

Refrigerant fluid sensor voltage QX70_REFRIGERANT_FLUID_V

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Upstream oxygen sensor voltage QX70_UP_OXYGEN_SENS_V

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Control

Accelerator pedal position QX70_APP

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2003 to 2017.

Anti-lock brake steering angle QX70_ABS_STEER_ANG

  • Service 22DID 1208
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2003 to 2017.

Brake master cylinder pressure QX70_BRAKE_MC_P

  • Service 22DID 1209
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.536
Range
0 to 42666.015
Unit
Raw value

In testing for 2003 to 2017.

BRAKE SWITCH, number 1 QX70_BRAKE_SWITCH_NUMBER_1

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

BRAKE SWITCH, number 2 QX70_BRAKE_SWITCH_NUMBER_2

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Left turn signal QX70_TURN_SIGNAL_LEFT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Right turn signal QX70_TURN_SIGNAL_RIGHT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Cruise control

Cruise control set speed QX70_CC_S

  • Service 22DID 122B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 3686 km/h
Unit
km/h

In testing for 2003 to 2017.

Engine

Air conditioning compressor QX70_AC_COMP

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Cooling fan high QX70_COOLING_FAN_HIGH

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Cooling fan low QX70_COOLING_FAN_LOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Engine oil temperature QX70_EOT

  • Service 22DID 2095
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2003 to 2017.

Idle control mode QX70_IDLE_CTRL_MODE

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Intake camshaft advance, bank 2 QX70_CAM_ADV_B2

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2003 to 2017.

Intake valve timing solenoid duty, bank 2 QX70_CAM_DUTY_B2

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2003 to 2017.

Mass air flow sensor voltage, bank 2 QX70_MAF_V_B2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Fuel

Air/fuel ratio adjustment, bank 2 QX70_AF_ADJ_B2

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2003 to 2017.

Movement

Engine speed QX70_TCM_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID 1204
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Engine speed, alternate QX70_TCM_RPM_2

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Input speed QX70_TCM_INPUT_RPM

  • Service 22DID 1201
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Output speed QX70_OUTPUT_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Primary pulley speed QX70_TCM_PRI_RPM

  • Service 22DID 1202
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Primary pulley speed, alternate QX70_TCM_PRI_RPM_2

  • Service 22DID 120D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Secondary pulley speed QX70_TCM_SEC_RPM

  • Service 22DID 1203
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Secondary pulley speed, alternate QX70_TCM_SEC_RPM_2

  • Service 22DID 120E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Turbine speed QX70_TURBINE_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Vehicle speed QX70_TCM_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2017.

Tires

Front left tire pressure QX70_TP_FL_743

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 0E26
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2003 to 2017.

Front right tire pressure QX70_TP_FR_743

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 0E25
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2003 to 2017.

Rear left tire pressure QX70_TP_RL_743

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 0E28
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2003 to 2017.

Rear right tire pressure QX70_TP_RR_743

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 0E27
  • Module743 → 763
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 psi
Unit
psi

In testing for 2003 to 2017.

Transmission

Acceleration sensor voltage QX70_TCM_G_V

  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.27 to 3.27 V
Unit
V

In testing for 2003 to 2017.

Engine torque QX70_TCM_ENG_TQ

  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2003 to 2017.

Engine torque, active QX70_TCM_ENG_TQ_ACT

  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2003 to 2017.

Engine torque, transmitted QX70_TCM_ENG_TQ_TX

  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2003 to 2017.

Estimated vehicle speed QX70_TCM_VSS_EST

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2017.

Fluid temperature sensor voltage QX70_TCM_ATF_T_V

  • Service 22DID 1207
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2003 to 2017.

Input speed, alternate QX70_TCM_INPUT_RPM_2

  • Service 22DID 120C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2003 to 2017.

Isolation solenoid 1 current QX70_TCM_ISO_1_C

  • Service 22DID 1219
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Isolation solenoid 2 current QX70_TCM_ISO_2_C

  • Service 22DID 121A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Line pressure QX70_TCM_LINE_P

  • Service 22DID 110E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2003 to 2017.

Lubrication pressure QX70_TCM_LUBE_P

  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270 kPa
Unit
kPa

In testing for 2003 to 2017.

Primary pressure sensor voltage QX70_TCM_PRI_P_V

  • Service 22DID 1206
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2003 to 2017.

Primary pulley torque QX70_TCM_PRI_TQ

  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2003 to 2017.

Primary solenoid current QX70_TCM_PRI_SOL_C

  • Service 22DID 121B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Primary solenoid monitor current QX70_TCM_PRI_SOL_MON

  • Service 22DID 1221
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Pulley ratio QX70_TCM_PULLEY_RAT

  • Service 22DID 1210
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2003 to 2017.

Requested engine speed QX70_TCM_REQ_RPM

  • Service 22DID 1114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2003 to 2017.

Requested torque QX70_TCM_REQ_TQ

  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2003 to 2017.

Requested torque delta QX70_TCM_REQ_TQ_D

  • Service 22DID 1112
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2003 to 2017.

Secondary pressure sensor voltage QX70_TCM_SEC_P_V

  • Service 22DID 1205
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2003 to 2017.

Secondary solenoid current QX70_TCM_SEC_SOL_C

  • Service 22DID 121C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Secondary solenoid monitor current QX70_TCM_SEC_SOL_MON

  • Service 22DID 1222
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Select solenoid current QX70_TCM_SEL_SOL_C

  • Service 22DID 121D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Select solenoid monitor current QX70_TCM_SEL_SOL_MON

  • Service 22DID 1223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Solenoid 1 monitor current QX70_TCM_SOL_MON_1

  • Service 22DID 121E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Solenoid 2 monitor current QX70_TCM_SOL_MON_2

  • Service 22DID 121F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2003 to 2017.

Target primary pulley pressure QX70_TCM_PRI_P_TGT

  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2003 to 2017.

Target pulley ratio QX70_TCM_PULLEY_RAT_TGT

  • Service 22DID 1218
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2003 to 2017.

Target secondary pulley pressure QX70_TCM_SEC_P_TGT

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2003 to 2017.

Target select pressure QX70_TCM_SEL_P_TGT

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2003 to 2017.

Torque converter slip QX70_TQ_CONV_SLIP

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2003 to 2017.

Torque ratio QX70_TCM_TQ_RAT

  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×577160000
Range
0 to 236
Unit
Number

In testing for 2003 to 2017.

Transmission ATF deterioration date QX70_TRANS_ATF

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2003 to 2017.

Transmission fluid temperature QX70_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2003 to 2017.

Transmission fluid temperature, variant 1 QX70_ATF_T_VAR_1

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2003 to 2017.

Transmission fluid temperature, variant 1 QX70_ATF_T_VAR_1_7E1

  • Service 22DID 0230
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2003 to 2017.

Transmission fluid temperature, variant 2 QX70_ATF_T_VAR_2

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2003 to 2017.

Transmission fluid temperature, variant 2 QX70_ATF_T_VAR_2_7E1

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2003 to 2017.

Transmission work hours QX70_TRANS_WORK_HOURS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2003 to 2017.

Transmission work hours warm engine QX70_TRANS_WORK_HOURS_WARM_ENG

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2003 to 2017.

Transmission-A QX70_TRANS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2017.

Transmission-B QX70_TRANS_B

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2017.

Vehicle speed sensor QX70_TCM_VSS_SENS

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2003 to 2017.

Trips

Odometer QX70_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 0E01
  • Module743 → 763
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

In testing for 2003 to 2017.

Odometer, meter group 1 QX70_MTR_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 56 to 79 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2003 to 2017.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.