INFINITI Q60

Parameters

The INFINITI Q60 has 110 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Cruise control set speed Q60_CC_SConfirmed

  • Service 22DID 122B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2015, 2018 to 2022

Example reply from a 2017 INFINITI Q60.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 3686 km/h
Unit
km/h

0x0000 = 0 → 0×9160 = 0 km/h

Confirmed for 2017. In testing for 2014 to 2015, 2018 to 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Manifold pressure sensor voltage Q60_MANIFOLD_P_SENS_V

  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Refrigerant fluid sensor voltage Q60_REFRIGERANT_FLUID_V

  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Upstream oxygen sensor voltage Q60_UP_OXYGEN_SENS_V

  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2017. Supported for 2019 to 2020.

Control

Accelerator pedal position Q60_APP

  • Service 22DID 1115
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2014 to 2015, 2017 to 2022.

Anti-lock brake steering angle Q60_ABS_STEER_ANG

  • Service 22DID 1208
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2014 to 2015, 2017 to 2022.

Brake master cylinder pressure Q60_BRAKE_MC_P

  • Service 22DID 1209
  • Module740 → 760
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.536
Range
0 to 42666.015
Unit
Raw value

In testing for 2014 to 2015, 2017 to 2022.

BRAKE SWITCH, number 1 Q60_BRAKE_SWITCH_NUMBER_1

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

BRAKE SWITCH, number 2 Q60_BRAKE_SWITCH_NUMBER_2

  • Service 22DID 130D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Left turn signal Q60_TURN_SIGNAL_LEFT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Right turn signal Q60_TURN_SIGNAL_RIGHT

  • Service 22DID 0103
  • Module707 → 727
  • Every100 ms
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Cruise control

Cruise control set speed Q60_CC_SConfirmed

  • Service 22DID 122B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2014 to 2015, 2018 to 2022

Example reply from a 2017 INFINITI Q60.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×9160
Range
0 to 3686 km/h
Unit
km/h

0x0000 = 0 → 0×9160 = 0 km/h

Confirmed for 2017. In testing for 2014 to 2015, 2018 to 2022.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017. Supported for 2019 to 2020.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017. Supported for 2019 to 2020.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2017. Supported for 2019 to 2020.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2017. Supported for 2019 to 2020.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017. Supported for 2019 to 2020.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2017.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017. Supported for 2019 to 2020.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2017. Supported for 2019 to 2020.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2019 to 2020.

Engine

Air conditioning compressor Q60_AC_COMP

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Cooling fan high Q60_COOLING_FAN_HIGH

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Cooling fan low Q60_COOLING_FAN_LOW

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Engine oil temperature Q60_EOT

  • Service 22DID 2095
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2014 to 2015, 2017 to 2022.

Idle control mode Q60_IDLE_CTRL_MODE

  • Service 22DID 1307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2015, 2017 to 2022.

Intake camshaft advance, bank 2 Q60_CAM_ADV_B2

  • Service 22DID 1137
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2014 to 2015, 2017 to 2022.

Intake valve timing solenoid duty, bank 2 Q60_CAM_DUTY_B2

  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

In testing for 2014 to 2015, 2017 to 2022.

Mass air flow sensor voltage, bank 2 Q60_MAF_V_B2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Fuel

Air/fuel ratio adjustment, bank 2 Q60_AF_ADJ_B2

  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 %
Unit
%

In testing for 2014 to 2015, 2017 to 2022.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2019 to 2020.

Movement

Engine speed Q60_TCM_RPM

Pelican can show this parameter as the engine speed.

  • Service 22DID 1204
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Engine speed, alternate Q60_TCM_RPM_2

  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Input speed Q60_TCM_INPUT_RPM

  • Service 22DID 1201
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Output speed Q60_OUTPUT_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Primary pulley speed Q60_TCM_PRI_RPM

  • Service 22DID 1202
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Primary pulley speed, alternate Q60_TCM_PRI_RPM_2

  • Service 22DID 120D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Secondary pulley speed Q60_TCM_SEC_RPM

  • Service 22DID 1203
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Secondary pulley speed, alternate Q60_TCM_SEC_RPM_2

  • Service 22DID 120E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Turbine speed Q60_TURBINE_SPD

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Vehicle speed Q60_TCM_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2017. Supported for 2019 to 2020.

Tires

Front left wheel speed Q60_FL_WHL_SPD

  • Service 22DID 4B00
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Front right wheel speed Q60_FR_WHL_SPD

  • Service 22DID 4B01
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Rear left wheel speed Q60_RL_WHL_SPD

  • Service 22DID 4B02
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Rear right wheel speed Q60_RR_WHL_SPD

  • Service 22DID 4B03
  • ModuleDA2D → 2D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Transmission

Acceleration sensor voltage Q60_TCM_G_V

  • Service 22DID 1208
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10000
Range
-3.27 to 3.27 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Engine torque Q60_TCM_ENG_TQ

  • Service 22DID 1214
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Engine torque, active Q60_TCM_ENG_TQ_ACT

  • Service 22DID 1212
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Engine torque, transmitted Q60_TCM_ENG_TQ_TX

  • Service 22DID 1213
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Estimated vehicle speed Q60_TCM_VSS_EST

  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Fluid temperature sensor voltage Q60_TCM_ATF_T_V

  • Service 22DID 1207
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Input speed, alternate Q60_TCM_INPUT_RPM_2

  • Service 22DID 120C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Isolation solenoid 1 current Q60_TCM_ISO_1_C

  • Service 22DID 1219
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Isolation solenoid 2 current Q60_TCM_ISO_2_C

  • Service 22DID 121A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Line pressure Q60_TCM_LINE_P

  • Service 22DID 110E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2014 to 2015, 2017 to 2022.

Lubrication pressure Q60_TCM_LUBE_P

  • Service 22DID 110D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×10
Range
-1280 to 1270 kPa
Unit
kPa

In testing for 2014 to 2015, 2017 to 2022.

Primary pressure sensor voltage Q60_TCM_PRI_P_V

  • Service 22DID 1206
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Primary pulley torque Q60_TCM_PRI_TQ

  • Service 22DID 1215
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Primary solenoid current Q60_TCM_PRI_SOL_C

  • Service 22DID 121B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Primary solenoid monitor current Q60_TCM_PRI_SOL_MON

  • Service 22DID 1221
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Pulley ratio Q60_TCM_PULLEY_RAT

  • Service 22DID 1210
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Requested engine speed Q60_TCM_REQ_RPM

  • Service 22DID 1114
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Requested torque Q60_TCM_REQ_TQ

  • Service 22DID 1113
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Requested torque delta Q60_TCM_REQ_TQ_D

  • Service 22DID 1112
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×2+100
Range
-156 to 354 N·m
Unit
N·m

In testing for 2014 to 2015, 2017 to 2022.

Secondary pressure sensor voltage Q60_TCM_SEC_P_V

  • Service 22DID 1205
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 320 V
Unit
V

In testing for 2014 to 2015, 2017 to 2022.

Secondary solenoid current Q60_TCM_SEC_SOL_C

  • Service 22DID 121C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Secondary solenoid monitor current Q60_TCM_SEC_SOL_MON

  • Service 22DID 1222
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Select solenoid current Q60_TCM_SEL_SOL_C

  • Service 22DID 121D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Select solenoid monitor current Q60_TCM_SEL_SOL_MON

  • Service 22DID 1223
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Solenoid 1 monitor current Q60_TCM_SOL_MON_1

  • Service 22DID 121E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Solenoid 2 monitor current Q60_TCM_SOL_MON_2

  • Service 22DID 121F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val1000
Range
0 to 0.255 A
Unit
A

In testing for 2014 to 2015, 2017 to 2022.

Target primary pulley pressure Q60_TCM_PRI_P_TGT

  • Service 22DID 110F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2014 to 2015, 2017 to 2022.

Target pulley ratio Q60_TCM_PULLEY_RAT_TGT

  • Service 22DID 1218
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Target secondary pulley pressure Q60_TCM_SEC_P_TGT

  • Service 22DID 1111
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2014 to 2015, 2017 to 2022.

Target select pressure Q60_TCM_SEL_P_TGT

  • Service 22DID 1110
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 kPa
Unit
kPa

In testing for 2014 to 2015, 2017 to 2022.

Torque converter slip Q60_TQ_CONV_SLIP

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2015, 2017 to 2022.

Torque ratio Q60_TCM_TQ_RAT

  • Service 22DID 1216
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×577160000
Range
0 to 236
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Transmission ATF deterioration date Q60_TRANS_ATF

  • Service 21PID 03
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Transmission fluid temperature Q60_TCM_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 110C
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2015, 2017 to 2022.

Transmission fluid temperature, variant 1 Q60_ATF_T_VAR_1

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2014 to 2015, 2017 to 2022.

Transmission fluid temperature, variant 1 Q60_ATF_T_VAR_1_7E1

  • Service 22DID 0230
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2014 to 2015, 2017 to 2022.

Transmission fluid temperature, variant 2 Q60_ATF_T_VAR_2

  • Service 21PID 01
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×95−67
Range
-67 to 392 °F
Unit
°F

In testing for 2014 to 2015, 2017 to 2022.

Transmission fluid temperature, variant 2 Q60_ATF_T_VAR_2_7E1

  • Service 21PID 30
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×95−58
Range
-58 to 401 °F
Unit
°F

In testing for 2014 to 2015, 2017 to 2022.

Transmission work hours Q60_TRANS_WORK_HOURS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2014 to 2015, 2017 to 2022.

Transmission work hours warm engine Q60_TRANS_WORK_HOURS_WARM_ENG

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val6
Range
0 to 10922 h
Unit
h

In testing for 2014 to 2015, 2017 to 2022.

Transmission-A Q60_TRANS

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Transmission-B Q60_TRANS_B

  • Service 21PID 10
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2015, 2017 to 2022.

Vehicle speed sensor Q60_TCM_VSS_SENS

  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2015, 2017 to 2022.

Trips

Odometer, meter group 1 Q60_MTR_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 01
  • Module743 → 763
  • Every30 s
  • Testing

Bits 56 to 79 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2014 to 2015, 2017 to 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.