Hyundai Ioniq Electric

Parameters

The Hyundai Ioniq Electric has 1,003 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery charge, displayed IONIQPHEV_HVBAT_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 248 to 255 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x6F = 111 → 1112 = 55.5 %

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery charge IONIQEV_VPWR_7E2

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

12V battery state of charge IONIQEV_BATTERY_SOCConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

0x4F = 79 → 79 %

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

A/C charger current IONIQEV_AC_CHARGER_CURRENT

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

A/C charging counter IONIQEV_HVBAT_AC_CHARGING_COUNTER

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

A/C charging time IONIQEV_VCMS__AC_CHARGING_TIME

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

A/C charging time, after plug-in IONIQEV_AC_CHARGING_TIME_AFTER_PLUG_IN

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Airbag hard-wire duty IONIQEV_AIRBAG_DUTYConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x50 = 80 → 80

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Aux battery state of charge IONIQEV_AUX_SOC

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Aux battery state of health IONIQEV_AUX_SOH

  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Auxiliary battery current IONIQEV_2025_AUX_BATTERY_CURRENT

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val100−327
Range
-327 to 328.35 A
Unit
A

In testing for 2016 to 2022.

Auxiliary battery current IONIQEV_AUX_BATTERY_CURRENT

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val100−327
Range
-327 to 328.35 A
Unit
A

In testing for 2016 to 2022.

Auxiliary battery current IONIQEV_AUXILIARY_BAT

  • Service 21PID 02
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2016 to 2022.

Auxiliary battery state of charge IONIQEV_2025_AUX_BATTERY_STATE_OF_CHARGE

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Auxiliary battery state of charge IONIQEV_AUX_BATTERY_STATE_OF_CHARGE

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Auxiliary battery state of charge IONIQEV_AUXILIARY_BAT_ST_CHG

  • Service 21PID 02
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2022.

Auxiliary battery temperature IONIQEV_2025_AUX_BATTERY_T

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727.5 °C
Unit
°C

In testing for 2016 to 2022.

Auxiliary battery temperature IONIQEV_AUX_BATTERY_T

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727.5 °C
Unit
°C

In testing for 2016 to 2022.

Auxiliary battery voltage IONIQEV_2025_AUX_BATTERY_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val1000+6
Range
6 to 71.535 V
Unit
V

In testing for 2016 to 2022.

Auxiliary battery voltage IONIQEV_AUX_BATTERY_VOLTAGE_7E5

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val1000+6
Range
6 to 71.535 V
Unit
V

In testing for 2016 to 2022.

Auxiliary battery voltage IONIQEV_AUXILIARY_BAT_V

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016 to 2022.

Available charge power IONIQEV_AVAILABLE_CHG_POWER

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655 kW
Unit
kW

In testing for 2016 to 2022.

Available discharge power IONIQEV_AVAILABLE_DCHG_POWER

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val100
Range
0 to 655 kW
Unit
kW

In testing for 2016 to 2022.

Battery auxiliary voltage IONIQEV_VPWR

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Battery capacity, battery sensor IONIQEV_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2016 to 2022.

Battery cell voltage deviation IONIQEV_HVBAT_C_DEV_VConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0x00 = 0 → 050 = 0 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery charge flag, battery sensor IONIQEV_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery current IONIQEV_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2016 to 2022.

Battery current IONIQEV_BAT_CURRENT_7E4

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2016 to 2022.

Battery current, battery sensor IONIQEV_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2016 to 2022.

Battery DC voltage IONIQEV_BAT_DC_V

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2016 to 2022.

Battery fan duty feedback IONIQEV_HVBAT_FAN_DUTY

  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Battery fan feedback IONIQEV_BAT_FAN_FEEDBACK

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 255 Hz
Unit
Hz

In testing for 2016 to 2022.

Battery fan status IONIQEV_BAT_FAN_STAT

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Battery health aging flag, battery sensor IONIQEV_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery heater 1 temperature IONIQEV_HVBAT_HTR1_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery heater 2 temperature IONIQEV_HVBAT_HTR2_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery inlet temperature IONIQEV_BAT_INLET_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery inlet temperature IONIQEV_HVBAT_INLET_T

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Battery is in use to crank the engine flag, battery sensor IONIQEV_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery management state IONIQEV_BMS_STATE

  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2016 to 2022.

Battery max temperature IONIQEV_BAT_MAX_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery min temperature IONIQEV_BAT_MIN_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 01 temperature IONIQEV_BAT_MODULE_01_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 128 to 135 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 02 temperature IONIQEV_BAT_MODULE_02_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 03 temperature IONIQEV_BAT_MODULE_03_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 04 temperature IONIQEV_BAT_MODULE_04_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 05 temperature IONIQEV_BAT_MODULE_05_T

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery module 06 temperature IONIQEV_HVBAT_MOD06_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 72 to 79 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 07 temperature IONIQEV_HVBAT_MOD07_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 80 to 87 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 08 temperature IONIQEV_HVBAT_MOD08_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 09 temperature IONIQEV_HVBAT_MOD09_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 10 temperature IONIQEV_HVBAT_MOD10_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 11 temperature IONIQEV_HVBAT_MOD11_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery module 12 temperature IONIQEV_HVBAT_MOD12_TConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

0x16 = 22 → 22 °C

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Battery pack B17 IONIQEV_BATTERY_PACK_B17

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2016 to 2022.

Battery pack B18 IONIQEV_BATTERY_PACK_B18

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

In testing for 2016 to 2022.

Battery quiescent current flag, battery sensor IONIQEV_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery sensor invalid condition flag, battery sensor IONIQEV_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery state of charge, battery sensor IONIQEV_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Battery state of function, battery sensor IONIQEV_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2016 to 2022.

Battery state of health, battery sensor IONIQEV_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Battery temperature IONIQEV_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2016 to 2022.

Battery temperature at the power relay assembly IONIQEV_HVBAT_PRA_T

  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 °C
Unit
°C

In testing for 2016 to 2022.

Battery temperature at WCS input IONIQEV_HVBAT_WCS_INLET_T

  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2022.

Battery temperature, battery sensor IONIQEV_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2022.

Battery voltage IONIQEV_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2016 to 2022.

Battery voltage IONIQEV_BATTERY_VConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xCE = 206 → 206×17.37255 = 14.032235 V

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Battery voltage after ignition IONIQEV_BATTERY_V_AFTER_IGNITIONConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val×17.37255
Range
0 to 17.37 V
Unit
V

0xCE = 206 → 206×17.37255 = 14.032235 V

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Battery voltage, battery sensor IONIQEV_BAT_V_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2016 to 2022.

Charge mode A/C maximum current limit IONIQEV_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Charge mode DC maximum current limit IONIQEV_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Charge mode DC target voltage IONIQEV_CHARGE_MODE_DC_TARGET_VOLTAGE

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2018.

Control pilot duty cycle IONIQEV_HVBAT_CP_DUTY_CYCLE

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Control pilot voltage IONIQEV_HVBAT_CP_VOLTAGE

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Cumulative charge current IONIQEV_CUM_CHG_CURRENT

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 240 to 271 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2016 to 2022.

Cumulative DC charging time IONIQEV_DC_CHRG_TIME

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Cumulative discharge current IONIQEV_CUM_DCHG_CURRENT

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 272 to 303 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2016 to 2022.

Cumulative energy charged IONIQEV_CUM_ENERGY_CHARGED

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 304 to 335 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 kWh
Unit
kWh

In testing for 2016 to 2022.

Cumulative energy discharged IONIQEV_CUM_ENERGY

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 336 to 367 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 kWh
Unit
kWh

In testing for 2016 to 2022.

DC charger current capability IONIQEV_DC_CHARGER_CURRENT_CAPABILITY

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

DC charging counter IONIQEV_HVBAT_CHRG_CNT

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

DC charging time, after plug-in IONIQEV_DC_CHARGING_TIME_AFTER_PLUG_IN

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Discharge mode A/C maximum current limit IONIQEV_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016 to 2022.

Discharge mode A/C target voltage IONIQEV_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGE

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2016 to 2022.

Discharge mode DC maximum current limit IONIQEV_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016 to 2022.

Electric oil pump, actual speed IONIQEV_EOP_ACTUAL_SPEED

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 2016 to 2022.

Electric oil pump, commanded speed IONIQEV_EOP_COMMANDED_SPEED

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 2016 to 2022.

Electric oil pump, current DC IONIQEV_EOP_CURRENT_DC

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016 to 2022.

Electric oil pump, current IQ IONIQEV_EOP_CURRENT_IQ

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016 to 2022.

Electric vehicle supply equipment, target current IONIQEV_HVBAT_TARGET_CURR

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Electric water pump, actual rotation speed IONIQEV_EWP_ACTUAL_ROTATION_SPEED

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2016 to 2022.

Electric water pump, commanded rotation speed IONIQEV_EWP_COMMANDED_ROTATION_SPEED

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

In testing for 2016 to 2022.

Electric water pump, current DC IONIQEV_EWP_CURRENT_DC

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2016 to 2022.

Electric water pump, voltage DC IONIQEV_EWP_VOLTAGE_DC

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016 to 2022.

High voltage battery, max current IONIQEV_HVBAT_EV_MAX_CURRENT

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, max voltage IONIQEV_HVBAT_EV_MAX_VOLTAGE

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, state of charge IONIQEV_HVBAT_SOC_VCMS

Pelican can show this parameter as the state of charge.

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, target current IONIQEV_HVBAT_BMS_TARGET_CURRENT

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, target voltage IONIQEV_HVBAT_BMS_TARGET_VOLTAGE

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, target voltage IONIQEV_HVBAT_TARGET_VOLT

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

High voltage battery, voltage IONIQEV_HVBAT_HV_BATTERY_VOLTAGE

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery charge IONIQEV_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery charge IONIQEV_HVBAT_SOC_DISP_7E4

Pelican can show this parameter as the state of charge.

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery charge, displayed IONIQPHEV_HVBAT_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 248 to 255 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x6F = 111 → 1112 = 55.5 %

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

HV battery charging IONIQEV_HVBAT_CHARGING

Pelican can show this parameter as the charging state.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery current IONIQEV_HVBAT_CURR

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery fan IONIQEV_HVBAT_FAN

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 255 Hz
Unit
Hz

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery fan status IONIQEV_HVBAT_FAN_STATUS

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery health IONIQPHEV_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 200 to 215 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x03A6 = 934 → 93410 = 93.4 %

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

HV battery heater 1 temperature IONIQEV_HVBAT_HTR1_T_2

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery heater 2 temperature IONIQEV_HVBAT_HTR2_T_2

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery max deterioration cell id IONIQEV_HVBAT_DET_MAX_ID

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 98
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery min deterioration IONIQEV_HVBAT_DET_MIN_2

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery min deterioration cell id IONIQEV_HVBAT_DET_MIN_ID

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val
Range
0 to 98
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery state of health IONIQEV_HVBAT_SOH_7E4

Pelican can show this parameter as the state of health.

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, maximum IONIQEV_HVBAT_T_MAX

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, minimum IONIQEV_HVBAT_T_MIN

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, module 1 IONIQEV_HVBAT_MOD1_T

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, module 2 IONIQEV_HVBAT_MOD2_T

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, module 3 IONIQEV_HVBAT_MOD3_T

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery temperature, module 4 IONIQEV_HVBAT_MOD4_T

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127 to 127 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery voltage, DC IONIQEV_HVBAT_VDC

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV cell deviation, voltage IONIQEV_HVBAT_C_DEV_V_2

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Ignition IONIQEV_IGN

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bit 405 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Inverter capacitor voltage IONIQEV_INVERTER_CAPACITOR_V

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2016 to 2022.

Inverter capacitor voltage IONIQEV_INVRT_CV

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Isolation resistance IONIQEV_ISO_R

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Least deteriorated cell number IONIQEV_HVBAT_DET_MIN_CELLConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 240 to 247 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x0A = 10 → 10

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Low-voltage dc-dc converter, input voltage IONIQEV_2025_LDC_INPUT_VOLTAGE

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Low-voltage dc-dc converter, input voltage IONIQEV_LDC_INPUT_VOLTAGE

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Low-voltage dc-dc converter, output current IONIQEV_2025_LDC_OUTPUT_CURRENT

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 A
Unit
A

In testing for 2016 to 2022.

Low-voltage dc-dc converter, output current IONIQEV_LDC_OUTPUT_CURRENT

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 A
Unit
A

In testing for 2016 to 2022.

Low-voltage dc-dc converter, output voltage IONIQEV_2025_LDC_OUTPUT_VOLTAGE

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2016 to 2022.

Low-voltage dc-dc converter, output voltage IONIQEV_LDC_OUTPUT_VOLTAGE

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2016 to 2022.

Low-voltage dc-dc converter, temperature IONIQEV_2025_LDC_T

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2016 to 2022.

Low-voltage dc-dc converter, temperature IONIQEV_LDC_T

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2016 to 2022.

Maximum cell voltage IONIQEV_C_V_MAX

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Maximum cell voltage IONIQEV_MAX_CELL_V

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016 to 2022.

Maximum cell voltage id IONIQEV_C_V_MAX_ID

The id of the cell with the highest voltage.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Maximum cell voltage no. IONIQEV_MAX_CELL_V_NO

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Minimum cell deterioration IONIQEV_HVBAT_DET_MINConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 224 to 239 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 %
Unit
%

0x03E8 = 1000 → 100010 = 100 %

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Minimum cell voltage IONIQEV_C_V_MIN

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Minimum cell voltage IONIQEV_MIN_CELL_V

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016 to 2022.

Minimum cell voltage id IONIQEV_C_V_MIN_ID

The id of the cell with the lowest voltage.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Minimum cell voltage no. IONIQEV_MIN_CELL_V_NO

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Most deteriorated cell number IONIQEV_HVBAT_DET_MAX_CELLConfirmed

  • Service 21PID 05
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x5A = 90 → 90

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Normal charge port IONIQEV_NORMAL_CHG_PORT

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 74 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Normal charge port state IONIQEV_HVBAT_PLUG_NORM

Pelican can show this parameter as the plug state.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bit 74 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Normal charging energy, total IONIQEV_NORMAL_CHARGING_ENERGY_TOT

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

In testing for 2016 to 2022.

Normal charging, count IONIQEV_NORMAL_CHARGING_COUNT

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2016 to 2022.

On-board charger charger AC input current, RMS IONIQEV_ON_BOARD_CHARGER

  • Service 21PID 01
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val×6425
Range
0 to 652 A
Unit
A

In testing for 2016 to 2022.

On-board charger charger AC input voltage, instant IONIQEV_ON_BOARD_CHARGER_CHARGER_V

  • Service 21PID 01
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×6425−100
Range
-100 to 552 V
Unit
V

In testing for 2016 to 2022.

On-board charger charger AC input voltage, RMS IONIQEV_ON_BOARD_CHARGER_V

  • Service 21PID 01
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×6425
Range
0 to 652 V
Unit
V

In testing for 2016 to 2022.

On-board charger charger temperature a IONIQEV_ON_BOARD_CHARGER_T

  • Service 21PID 01
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2016 to 2022.

On-board charger charger temperature b IONIQEV_ON_BOARD_CHARGER_T_B

  • Service 21PID 01
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 336 to 343 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

In testing for 2016 to 2022.

Proximity detection voltage IONIQEV_HVBAT_PD_VOLTAGE

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Quick charging energy, total IONIQEV_QUICK_CHARGING_ENERGY_TOT

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

In testing for 2016 to 2022.

Quick charging, count IONIQEV_QUICK_CHARGING_COUNT

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2016 to 2022.

Rapid charge port IONIQEV_RAPID_CHG_PORT

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 73 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Rapid charge port state IONIQEV_HVBAT_PLUG_RAPD

Pelican can show this parameter as the plug state.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bit 73 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Relative accelerator pedal position voltage IONIQEV_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2016 to 2022.

Response error from battery sensor flag, battery sensor IONIQEV_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

State of charge BMS IONIQEV_ST_CHG_BMS

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2016 to 2022.

Supply voltage IONIQEV_SUPPLY_VOLTAGE

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016 to 2022.

System voltage IONIQEV_SYSTEM_VOLTAGE

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016 to 2022.

Throttle position sensor voltage #1 IONIQEV_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2016 to 2022.

Throttle position sensor voltage #2 IONIQEV_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2016 to 2022.

Total charge, current IONIQEV_HVBAT_CHRG_TOT_C

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 271 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Total charge, energy IONIQEV_HVBAT_CHRG_TOT_E

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 304 to 335 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 kWh
Unit
kWh

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Total discharge, current IONIQEV_HVBAT_DSCH_TOT_C

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 303 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Total discharge, energy IONIQEV_HVBAT_DSCH_TOT_E

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 336 to 367 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 kWh
Unit
kWh

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Wastegate position voltage IONIQEV_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2016 to 2022.

Charging

400V relay on/off request IONIQEV_400V_RELAY_ON_OFF_REQUEST

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 43 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

400V relay status IONIQEV_400V_RELAY_STATUS

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

AC charging state IONIQEV_AC_CHRG_STATE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 141 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

AC inlet temperature 1 IONIQEV_AC_INLET_T_1

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Auxiliary battery voltage IONIQEV_AUX_BATTERY_VOLTAGE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Battery main relay status IONIQEV_BATTERY_MAIN_RELAY_STATUS

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Charging socket connected IONIQEV_CHARGING_SOCKET_CONNECTED

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

DC charging state IONIQEV_DC_CHRG_STATE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bit 140 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

DC inlet temperature 1 IONIQEV_DC_INLET_T_1

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

DC inlet temperature 2 IONIQEV_DC_INLET_T_2

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Electric vehicle supply equipment, current IONIQEV_EVSE_C

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Electric vehicle supply equipment, current, max IONIQEV_EVSE_MAXIMUM_CURRENT_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Electric vehicle supply equipment, current, min IONIQEV_EVSE_MINIMUM_CURRENT_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Electric vehicle supply equipment, power, delivered IONIQEV_EVSE_DELIVERED_POWER_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 kWh
Unit
kWh

In testing for 2016 to 2022.

Electric vehicle supply equipment, power, main IONIQEV_EVSE_MAIN_POWER

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

In testing for 2016 to 2022.

Electric vehicle supply equipment, power, max IONIQEV_EVSE_MAXIMUM_POWER_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

In testing for 2016 to 2022.

Electric vehicle supply equipment, regulation tolerance IONIQEV_EVSE_CURRENT_REGULATION_TOLERANCE_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 A
Unit
A

In testing for 2016 to 2022.

Electric vehicle supply equipment, voltage IONIQEV_EVSE_V

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Electric vehicle supply equipment, voltage, max IONIQEV_EVSE_MAXIMUM_VOLTAGE_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Electric vehicle supply equipment, voltage, min IONIQEV_EVSE_MINIMUM_VOLTAGE_VALUE

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

Estimated charging power IONIQEV_ESTIMATED_CHRG_POWER

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×10−50
Range
-50 to 655300 W
Unit
W

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, AC current a IONIQEV_OBC_AC_CURRENT_A_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, AC current b IONIQEV_OBC_AC_CURRENT_B_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, AC frequency IONIQEV_OBC_AC_FREQUENCY

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 Hz
Unit
Hz

In testing for 2016 to 2022.

On-board charger, AC input current sensor a signal voltage IONIQEV_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGE

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2016 to 2022.

On-board charger, AC input current sensor b signal voltage IONIQEV_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGE

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2016 to 2022.

On-board charger, AC total current IONIQEV_OBC_AC_TOTAL_CURRENT_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, AC voltage a IONIQEV_OBC_AC_VOLTAGE_A_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

On-board charger, AC voltage b IONIQEV_OBC_AC_VOLTAGE_B_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

On-board charger, charge mode DC target current IONIQEV_OBC_CHARGE_MODE_DC_TARGET_CURRENT

  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

On-board charger, charge mode DC target voltage IONIQEV_OBC_CHARGE_MODE_DC_TARGET_VOLTAGE

  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

On-board charger, charging AC current IONIQEV_OBC_CHRG_AC_CURRENT

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, charging AC voltage IONIQEV_OBC_CHRG_AC_VOLTAGE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, charging DC current IONIQEV_OBC_CHRG_DC_CURRENT

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, charging DC voltage IONIQEV_OBC_CHRG_DC_VOLTAGE

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, DC current a IONIQEV_OBC_DC_CURRENT_A_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, DC current b IONIQEV_OBC_DC_CURRENT_B_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, DC current total IONIQEV_OBC_DC_CURRENT_TOTAL_RMS

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

In testing for 2016 to 2022.

On-board charger, DC voltage IONIQEV_OBC_DC_VOLTAGE

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2016 to 2022.

On-board charger, discharging AC current IONIQEV_OBC_DCHRG_AC_CURRENT

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, discharging DC current IONIQEV_OBC_DCHRG_DC_CURRENT

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

On-board charger, temperature a IONIQEV_OBC_T_A

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

On-board charger, temperature b IONIQEV_OBC_T_B

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

Modules › 001

HV battery module 001 voltage IONIQEV_HVBAT_CMU001_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 001 voltage IONIQPHEV_HVBAT_CMU001_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 002

HV battery module 002 voltage IONIQEV_HVBAT_CMU002_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 002 voltage IONIQPHEV_HVBAT_CMU002_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 003

HV battery module 003 voltage IONIQEV_HVBAT_CMU003_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 003 voltage IONIQPHEV_HVBAT_CMU003_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 004

HV battery module 004 voltage IONIQEV_HVBAT_CMU004_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 004 voltage IONIQPHEV_HVBAT_CMU004_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 005

HV battery module 005 voltage IONIQEV_HVBAT_CMU005_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 005 voltage IONIQPHEV_HVBAT_CMU005_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 006

HV battery module 006 voltage IONIQEV_HVBAT_CMU006_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 006 voltage IONIQPHEV_HVBAT_CMU006_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 007

HV battery module 007 voltage IONIQEV_HVBAT_CMU007_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 007 voltage IONIQPHEV_HVBAT_CMU007_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 008

HV battery module 008 voltage IONIQEV_HVBAT_CMU008_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 008 voltage IONIQPHEV_HVBAT_CMU008_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 009

HV battery module 009 voltage IONIQEV_HVBAT_CMU009_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 009 voltage IONIQPHEV_HVBAT_CMU009_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 010

HV battery module 010 voltage IONIQEV_HVBAT_CMU010_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 010 voltage IONIQPHEV_HVBAT_CMU010_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 011

HV battery module 011 voltage IONIQEV_HVBAT_CMU011_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 011 voltage IONIQPHEV_HVBAT_CMU011_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 012

HV battery module 012 voltage IONIQEV_HVBAT_CMU012_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 012 voltage IONIQPHEV_HVBAT_CMU012_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 013

HV battery module 013 voltage IONIQEV_HVBAT_CMU013_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 013 voltage IONIQPHEV_HVBAT_CMU013_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 014

HV battery module 014 voltage IONIQEV_HVBAT_CMU014_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 014 voltage IONIQPHEV_HVBAT_CMU014_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 015

HV battery module 015 voltage IONIQEV_HVBAT_CMU015_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 015 voltage IONIQPHEV_HVBAT_CMU015_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 016

HV battery module 016 voltage IONIQEV_HVBAT_CMU016_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 016 voltage IONIQPHEV_HVBAT_CMU016_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 017

HV battery module 017 voltage IONIQEV_HVBAT_CMU017_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 017 voltage IONIQPHEV_HVBAT_CMU017_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 018

HV battery module 018 voltage IONIQEV_HVBAT_CMU018_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 018 voltage IONIQPHEV_HVBAT_CMU018_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 019

HV battery module 019 voltage IONIQEV_HVBAT_CMU019_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 019 voltage IONIQPHEV_HVBAT_CMU019_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 020

HV battery module 020 voltage IONIQEV_HVBAT_CMU020_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 020 voltage IONIQPHEV_HVBAT_CMU020_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 021

HV battery module 021 voltage IONIQEV_HVBAT_CMU021_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 021 voltage IONIQPHEV_HVBAT_CMU021_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 022

HV battery module 022 voltage IONIQEV_HVBAT_CMU022_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 022 voltage IONIQPHEV_HVBAT_CMU022_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 023

HV battery module 023 voltage IONIQEV_HVBAT_CMU023_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 023 voltage IONIQPHEV_HVBAT_CMU023_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 024

HV battery module 024 voltage IONIQEV_HVBAT_CMU024_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 024 voltage IONIQPHEV_HVBAT_CMU024_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 025

HV battery module 025 voltage IONIQEV_HVBAT_CMU025_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 025 voltage IONIQPHEV_HVBAT_CMU025_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 026

HV battery module 026 voltage IONIQEV_HVBAT_CMU026_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 026 voltage IONIQPHEV_HVBAT_CMU026_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 027

HV battery module 027 voltage IONIQEV_HVBAT_CMU027_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 027 voltage IONIQPHEV_HVBAT_CMU027_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 028

HV battery module 028 voltage IONIQEV_HVBAT_CMU028_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 028 voltage IONIQPHEV_HVBAT_CMU028_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 029

HV battery module 029 voltage IONIQEV_HVBAT_CMU029_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 029 voltage IONIQPHEV_HVBAT_CMU029_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 030

HV battery module 030 voltage IONIQEV_HVBAT_CMU030_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 030 voltage IONIQPHEV_HVBAT_CMU030_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 031

HV battery module 031 voltage IONIQEV_HVBAT_CMU031_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 031 voltage IONIQPHEV_HVBAT_CMU031_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 032

HV battery module 032 voltage IONIQEV_HVBAT_CMU032_VOLT_7E4

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 032 voltage IONIQPHEV_HVBAT_CMU032_VOLTConfirmed

  • Service 21PID 02
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 033

HV battery module 033 voltage IONIQEV_HVBAT_CMU033_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 033 voltage IONIQPHEV_HVBAT_CMU033_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 034

HV battery module 034 voltage IONIQEV_HVBAT_CMU034_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 034 voltage IONIQPHEV_HVBAT_CMU034_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 035

HV battery module 035 voltage IONIQEV_HVBAT_CMU035_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 035 voltage IONIQPHEV_HVBAT_CMU035_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 036

HV battery module 036 voltage IONIQEV_HVBAT_CMU036_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 036 voltage IONIQPHEV_HVBAT_CMU036_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 037

HV battery module 037 voltage IONIQEV_HVBAT_CMU037_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 037 voltage IONIQPHEV_HVBAT_CMU037_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 038

HV battery module 038 voltage IONIQEV_HVBAT_CMU038_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 038 voltage IONIQPHEV_HVBAT_CMU038_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 039

HV battery module 039 voltage IONIQEV_HVBAT_CMU039_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 039 voltage IONIQPHEV_HVBAT_CMU039_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 040

HV battery module 040 voltage IONIQEV_HVBAT_CMU040_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 040 voltage IONIQPHEV_HVBAT_CMU040_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 041

HV battery module 041 voltage IONIQEV_HVBAT_CMU041_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 041 voltage IONIQPHEV_HVBAT_CMU041_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 042

HV battery module 042 voltage IONIQEV_HVBAT_CMU042_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 042 voltage IONIQPHEV_HVBAT_CMU042_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 043

HV battery module 043 voltage IONIQEV_HVBAT_CMU043_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 043 voltage IONIQPHEV_HVBAT_CMU043_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 044

HV battery module 044 voltage IONIQEV_HVBAT_CMU044_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 044 voltage IONIQPHEV_HVBAT_CMU044_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 045

HV battery module 045 voltage IONIQEV_HVBAT_CMU045_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 045 voltage IONIQPHEV_HVBAT_CMU045_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 046

HV battery module 046 voltage IONIQEV_HVBAT_CMU046_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 046 voltage IONIQPHEV_HVBAT_CMU046_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 047

HV battery module 047 voltage IONIQEV_HVBAT_CMU047_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 047 voltage IONIQPHEV_HVBAT_CMU047_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 048

HV battery module 048 voltage IONIQEV_HVBAT_CMU048_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 048 voltage IONIQPHEV_HVBAT_CMU048_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 049

HV battery module 049 voltage IONIQEV_HVBAT_CMU049_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 049 voltage IONIQPHEV_HVBAT_CMU049_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 050

HV battery module 050 voltage IONIQEV_HVBAT_CMU050_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 050 voltage IONIQPHEV_HVBAT_CMU050_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 051

HV battery module 051 voltage IONIQEV_HVBAT_CMU051_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 051 voltage IONIQPHEV_HVBAT_CMU051_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 052

HV battery module 052 voltage IONIQEV_HVBAT_CMU052_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 052 voltage IONIQPHEV_HVBAT_CMU052_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 053

HV battery module 053 voltage IONIQEV_HVBAT_CMU053_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 053 voltage IONIQPHEV_HVBAT_CMU053_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 054

HV battery module 054 voltage IONIQEV_HVBAT_CMU054_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 054 voltage IONIQPHEV_HVBAT_CMU054_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 055

HV battery module 055 voltage IONIQEV_HVBAT_CMU055_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 055 voltage IONIQPHEV_HVBAT_CMU055_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 056

HV battery module 056 voltage IONIQEV_HVBAT_CMU056_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 056 voltage IONIQPHEV_HVBAT_CMU056_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 057

HV battery module 057 voltage IONIQEV_HVBAT_CMU057_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 057 voltage IONIQPHEV_HVBAT_CMU057_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 058

HV battery module 058 voltage IONIQEV_HVBAT_CMU058_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 058 voltage IONIQPHEV_HVBAT_CMU058_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 059

HV battery module 059 voltage IONIQEV_HVBAT_CMU059_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 059 voltage IONIQPHEV_HVBAT_CMU059_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 060

HV battery module 060 voltage IONIQEV_HVBAT_CMU060_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 060 voltage IONIQPHEV_HVBAT_CMU060_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 061

HV battery module 061 voltage IONIQEV_HVBAT_CMU061_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 061 voltage IONIQPHEV_HVBAT_CMU061_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 062

HV battery module 062 voltage IONIQEV_HVBAT_CMU062_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 062 voltage IONIQPHEV_HVBAT_CMU062_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 063

HV battery module 063 voltage IONIQEV_HVBAT_CMU063_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 063 voltage IONIQPHEV_HVBAT_CMU063_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 064

HV battery module 064 voltage IONIQEV_HVBAT_CMU064_VOLT_7E4

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 064 voltage IONIQPHEV_HVBAT_CMU064_VOLTConfirmed

  • Service 21PID 03
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 065

HV battery module 065 voltage IONIQEV_HVBAT_CMU065_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 065 voltage IONIQPHEV_HVBAT_CMU065_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 066

HV battery module 066 voltage IONIQEV_HVBAT_CMU066_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 066 voltage IONIQPHEV_HVBAT_CMU066_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 067

HV battery module 067 voltage IONIQEV_HVBAT_CMU067_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 067 voltage IONIQPHEV_HVBAT_CMU067_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 068

HV battery module 068 voltage IONIQEV_HVBAT_CMU068_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 068 voltage IONIQPHEV_HVBAT_CMU068_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 069

HV battery module 069 voltage IONIQEV_HVBAT_CMU069_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 069 voltage IONIQPHEV_HVBAT_CMU069_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 070

HV battery module 070 voltage IONIQEV_HVBAT_CMU070_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 070 voltage IONIQPHEV_HVBAT_CMU070_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 071

HV battery module 071 voltage IONIQEV_HVBAT_CMU071_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 071 voltage IONIQPHEV_HVBAT_CMU071_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 072

HV battery module 072 voltage IONIQEV_HVBAT_CMU072_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 072 voltage IONIQPHEV_HVBAT_CMU072_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 073

HV battery module 073 voltage IONIQEV_HVBAT_CMU073_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 073 voltage IONIQPHEV_HVBAT_CMU073_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 074

HV battery module 074 voltage IONIQEV_HVBAT_CMU074_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 074 voltage IONIQPHEV_HVBAT_CMU074_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 075

HV battery module 075 voltage IONIQEV_HVBAT_CMU075_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 075 voltage IONIQPHEV_HVBAT_CMU075_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 076

HV battery module 076 voltage IONIQEV_HVBAT_CMU076_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 076 voltage IONIQPHEV_HVBAT_CMU076_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 077

HV battery module 077 voltage IONIQEV_HVBAT_CMU077_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 077 voltage IONIQPHEV_HVBAT_CMU077_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 078

HV battery module 078 voltage IONIQEV_HVBAT_CMU078_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 078 voltage IONIQPHEV_HVBAT_CMU078_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 079

HV battery module 079 voltage IONIQEV_HVBAT_CMU079_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 079 voltage IONIQPHEV_HVBAT_CMU079_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 080

HV battery module 080 voltage IONIQEV_HVBAT_CMU080_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 080 voltage IONIQPHEV_HVBAT_CMU080_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 081

HV battery module 081 voltage IONIQEV_HVBAT_CMU081_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 081 voltage IONIQPHEV_HVBAT_CMU081_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 082

HV battery module 082 voltage IONIQEV_HVBAT_CMU082_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 082 voltage IONIQPHEV_HVBAT_CMU082_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 083

HV battery module 083 voltage IONIQEV_HVBAT_CMU083_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 083 voltage IONIQPHEV_HVBAT_CMU083_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 084

HV battery module 084 voltage IONIQEV_HVBAT_CMU084_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 084 voltage IONIQPHEV_HVBAT_CMU084_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 085

HV battery module 085 voltage IONIQEV_HVBAT_CMU085_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 085 voltage IONIQPHEV_HVBAT_CMU085_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 086

HV battery module 086 voltage IONIQEV_HVBAT_CMU086_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 086 voltage IONIQPHEV_HVBAT_CMU086_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 087

HV battery module 087 voltage IONIQEV_HVBAT_CMU087_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 087 voltage IONIQPHEV_HVBAT_CMU087_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 088

HV battery module 088 voltage IONIQEV_HVBAT_CMU088_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 088 voltage IONIQPHEV_HVBAT_CMU088_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 089

HV battery module 089 voltage IONIQEV_HVBAT_CMU089_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 089 voltage IONIQPHEV_HVBAT_CMU089_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 090

HV battery module 090 voltage IONIQEV_HVBAT_CMU090_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 090 voltage IONIQPHEV_HVBAT_CMU090_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 091

HV battery module 091 voltage IONIQEV_HVBAT_CMU091_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 091 voltage IONIQPHEV_HVBAT_CMU091_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 092

HV battery module 092 voltage IONIQEV_HVBAT_CMU092_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 092 voltage IONIQPHEV_HVBAT_CMU092_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 093

HV battery module 093 voltage IONIQEV_HVBAT_CMU093_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 093 voltage IONIQPHEV_HVBAT_CMU093_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 094

HV battery module 094 voltage IONIQEV_HVBAT_CMU094_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 094 voltage IONIQPHEV_HVBAT_CMU094_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 095

HV battery module 095 voltage IONIQEV_HVBAT_CMU095_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 095 voltage IONIQPHEV_HVBAT_CMU095_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB8 = 184 → 18450 = 3.68 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 096

HV battery module 096 voltage IONIQEV_HVBAT_CMU096_VOLT_7E4

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 096 voltage IONIQPHEV_HVBAT_CMU096_VOLTConfirmed

  • Service 21PID 04
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2016, 2020 to 2022

Example reply from a 2019 Hyundai Ioniq Electric.

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

0xB7 = 183 → 18350 = 3.66 V

Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.

Modules › 097

HV battery module 097 voltage IONIQEV_HVBAT_CMU097_VOLT

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 097 voltage IONIQEV_HVBAT_CMU097_VOLT_7E4

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 098

HV battery module 098 voltage IONIQEV_HVBAT_CMU098_VOLT

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

HV battery module 098 voltage IONIQEV_HVBAT_CMU098_VOLT_7E4

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 099

HV battery module 099 voltage IONIQEV_HVBAT_CMU099_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 100

HV battery module 100 voltage IONIQEV_HVBAT_CMU100_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 101

HV battery module 101 voltage IONIQEV_HVBAT_CMU101_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 102

HV battery module 102 voltage IONIQEV_HVBAT_CMU102_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 103

HV battery module 103 voltage IONIQEV_HVBAT_CMU103_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 104

HV battery module 104 voltage IONIQEV_HVBAT_CMU104_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 105

HV battery module 105 voltage IONIQEV_HVBAT_CMU105_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 106

HV battery module 106 voltage IONIQEV_HVBAT_CMU106_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 107

HV battery module 107 voltage IONIQEV_HVBAT_CMU107_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 108

HV battery module 108 voltage IONIQEV_HVBAT_CMU108_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 109

HV battery module 109 voltage IONIQEV_HVBAT_CMU109_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 110

HV battery module 110 voltage IONIQEV_HVBAT_CMU110_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 111

HV battery module 111 voltage IONIQEV_HVBAT_CMU111_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 112

HV battery module 112 voltage IONIQEV_HVBAT_CMU112_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 113

HV battery module 113 voltage IONIQEV_HVBAT_CMU113_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 114

HV battery module 114 voltage IONIQEV_HVBAT_CMU114_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 115

HV battery module 115 voltage IONIQEV_HVBAT_CMU115_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 116

HV battery module 116 voltage IONIQEV_HVBAT_CMU116_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 117

HV battery module 117 voltage IONIQEV_HVBAT_CMU117_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 118

HV battery module 118 voltage IONIQEV_HVBAT_CMU118_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 119

HV battery module 119 voltage IONIQEV_HVBAT_CMU119_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 120

HV battery module 120 voltage IONIQEV_HVBAT_CMU120_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 121

HV battery module 121 voltage IONIQEV_HVBAT_CMU121_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 122

HV battery module 122 voltage IONIQEV_HVBAT_CMU122_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 123

HV battery module 123 voltage IONIQEV_HVBAT_CMU123_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 124

HV battery module 124 voltage IONIQEV_HVBAT_CMU124_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 125

HV battery module 125 voltage IONIQEV_HVBAT_CMU125_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 126

HV battery module 126 voltage IONIQEV_HVBAT_CMU126_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 127

HV battery module 127 voltage IONIQEV_HVBAT_CMU127_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 128

HV battery module 128 voltage IONIQEV_HVBAT_CMU128_VOLT

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 129

HV battery module 129 voltage IONIQEV_HVBAT_CMU129_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 130

HV battery module 130 voltage IONIQEV_HVBAT_CMU130_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 131

HV battery module 131 voltage IONIQEV_HVBAT_CMU131_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 132

HV battery module 132 voltage IONIQEV_HVBAT_CMU132_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 133

HV battery module 133 voltage IONIQEV_HVBAT_CMU133_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 134

HV battery module 134 voltage IONIQEV_HVBAT_CMU134_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 135

HV battery module 135 voltage IONIQEV_HVBAT_CMU135_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 136

HV battery module 136 voltage IONIQEV_HVBAT_CMU136_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 137

HV battery module 137 voltage IONIQEV_HVBAT_CMU137_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 138

HV battery module 138 voltage IONIQEV_HVBAT_CMU138_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 139

HV battery module 139 voltage IONIQEV_HVBAT_CMU139_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 140

HV battery module 140 voltage IONIQEV_HVBAT_CMU140_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 141

HV battery module 141 voltage IONIQEV_HVBAT_CMU141_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 142

HV battery module 142 voltage IONIQEV_HVBAT_CMU142_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 143

HV battery module 143 voltage IONIQEV_HVBAT_CMU143_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 144

HV battery module 144 voltage IONIQEV_HVBAT_CMU144_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 145

HV battery module 145 voltage IONIQEV_HVBAT_CMU145_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 146

HV battery module 146 voltage IONIQEV_HVBAT_CMU146_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 147

HV battery module 147 voltage IONIQEV_HVBAT_CMU147_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 148

HV battery module 148 voltage IONIQEV_HVBAT_CMU148_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 149

HV battery module 149 voltage IONIQEV_HVBAT_CMU149_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 150

HV battery module 150 voltage IONIQEV_HVBAT_CMU150_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 151

HV battery module 151 voltage IONIQEV_HVBAT_CMU151_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 152

HV battery module 152 voltage IONIQEV_HVBAT_CMU152_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 153

HV battery module 153 voltage IONIQEV_HVBAT_CMU153_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 154

HV battery module 154 voltage IONIQEV_HVBAT_CMU154_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 155

HV battery module 155 voltage IONIQEV_HVBAT_CMU155_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 156

HV battery module 156 voltage IONIQEV_HVBAT_CMU156_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 157

HV battery module 157 voltage IONIQEV_HVBAT_CMU157_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 158

HV battery module 158 voltage IONIQEV_HVBAT_CMU158_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 159

HV battery module 159 voltage IONIQEV_HVBAT_CMU159_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 160

HV battery module 160 voltage IONIQEV_HVBAT_CMU160_VOLT

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 161

HV battery module 161 voltage IONIQEV_HVBAT_CMU161_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 162

HV battery module 162 voltage IONIQEV_HVBAT_CMU162_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 163

HV battery module 163 voltage IONIQEV_HVBAT_CMU163_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 164

HV battery module 164 voltage IONIQEV_HVBAT_CMU164_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 165

HV battery module 165 voltage IONIQEV_HVBAT_CMU165_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 166

HV battery module 166 voltage IONIQEV_HVBAT_CMU166_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 167

HV battery module 167 voltage IONIQEV_HVBAT_CMU167_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 168

HV battery module 168 voltage IONIQEV_HVBAT_CMU168_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 169

HV battery module 169 voltage IONIQEV_HVBAT_CMU169_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 170

HV battery module 170 voltage IONIQEV_HVBAT_CMU170_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 171

HV battery module 171 voltage IONIQEV_HVBAT_CMU171_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 172

HV battery module 172 voltage IONIQEV_HVBAT_CMU172_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 173

HV battery module 173 voltage IONIQEV_HVBAT_CMU173_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 174

HV battery module 174 voltage IONIQEV_HVBAT_CMU174_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 175

HV battery module 175 voltage IONIQEV_HVBAT_CMU175_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 176

HV battery module 176 voltage IONIQEV_HVBAT_CMU176_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 177

HV battery module 177 voltage IONIQEV_HVBAT_CMU177_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 178

HV battery module 178 voltage IONIQEV_HVBAT_CMU178_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 179

HV battery module 179 voltage IONIQEV_HVBAT_CMU179_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 180

HV battery module 180 voltage IONIQEV_HVBAT_CMU180_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 181

HV battery module 181 voltage IONIQEV_HVBAT_CMU181_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 182

HV battery module 182 voltage IONIQEV_HVBAT_CMU182_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 183

HV battery module 183 voltage IONIQEV_HVBAT_CMU183_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 184

HV battery module 184 voltage IONIQEV_HVBAT_CMU184_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 185

HV battery module 185 voltage IONIQEV_HVBAT_CMU185_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 186

HV battery module 186 voltage IONIQEV_HVBAT_CMU186_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 187

HV battery module 187 voltage IONIQEV_HVBAT_CMU187_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 188

HV battery module 188 voltage IONIQEV_HVBAT_CMU188_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 189

HV battery module 189 voltage IONIQEV_HVBAT_CMU189_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 190

HV battery module 190 voltage IONIQEV_HVBAT_CMU190_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 191

HV battery module 191 voltage IONIQEV_HVBAT_CMU191_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Modules › 192

HV battery module 192 voltage IONIQEV_HVBAT_CMU192_VOLT

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Climate

A/C compressor operation RPM IONIQEV_AC_COMPRESSOR_OPERATION_RPM

  • Service 22DID 0114
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 rpm
Unit
rpm

In testing for 2016 to 2022.

Air conditioning compressor speed IONIQEV_AC_COMP_RPM

  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

In testing for 2016 to 2022.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018.

Ambient temperature, vehicle control unit IONIQEV_AAT_VMCU

  • Service 21PID 80
  • Module7E6 → 7EE
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val2−40
Range
-104 to 23.5 °C
Unit
°C

In testing for 2016 to 2022.

Evaporator temperature IONIQEV_HVAC_EVAPORATOR_TConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 56 to 63 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x58 = 88 → 882−40 = 4 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Heated steering wheel IONIQEV_HEATED_WHEEL

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Humidity sensor for automatic defogger IONIQEV_HVAC_HUMIDITY_SENSOR_FOR_AUTOMATIC_DEFOGGERConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x21 = 33 → 33 %

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Interior temperature, driver legs vent IONIQEV_HVAC_IAT_DRIVER_LEGS_VENTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 224 to 231 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x75 = 117 → 1172−40 = 18.5 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Interior temperature, driver vent IONIQEV_HVAC_IAT_DRIVER_VENTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 216 to 223 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x61 = 97 → 972−40 = 8.5 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Interior temperature, front IONIQEV_HVAC_IATConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x80 = 128 → 1282−40 = 24 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Interior temperature, passenger legs vent IONIQEV_HVAC_IAT_PASSENGER_LEGS_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2022.

Interior temperature, passenger vent IONIQEV_HVAC_IAT_PASSENGER_VENT

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2022.

Outdoor temperature IONIQEV_HVAC_AATConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x75 = 117 → 1172−40 = 18.5 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2017 to 2018.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Accelerator pedal position IONIQEV_APP

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Brake lamp on IONIQEV_BRAKE_LAMP

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Brake pedal IONIQEV_BRAKE_PEDAL_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Relative accelerator pedal position IONIQEV_APP_REL_AWD

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Steering wheel angle IONIQEV_STEER_ANGLE

  • Service 21PID 01
  • Module7D4 → 7DC
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Steering wheel angle IONIQEV_STEERING_ANGLE

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2016 to 2022.

Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Doors

Front left door locked? IONIQEV_LOCK_FLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 36 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Front right door locked? IONIQEV_LOCK_FRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Number

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed

Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.

  • Service 01PID 4E
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2017 to 2018.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 4D
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2017 to 2018.

Status

A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Catalyst monitoring CAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

EGR system monitoring EGR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

EGR system monitoring completed EGR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Evaporative system monitoring EVAP_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Heated catalyst monitoring HCAT_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Misfire monitoring completed MIS_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Oxygen sensor monitoring O2S_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Secondary air system monitoring AIR_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2018.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2018.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Misfire monitoring enabled MIS_ENASAE J1979Confirmed

  • Service 01PID 41
  • Module7E0 → 7E8
  • Every1 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017 to 2018. Supported for 2019 to 2021.

Engine

4WD calculated clutch power IONIQEV_AWD_CALC_CLU_POWER

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×39.06210000
Range
0 to 255 kWh
Unit
kWh

In testing for 2016 to 2022.

4WD calculated engine power IONIQEV_AWD_CALC_ENG_POWER

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×9.76610000
Range
0 to 64 kWh
Unit
kWh

In testing for 2016 to 2022.

4WD calculated, commanded torque IONIQEV_AWD_CALC_CMD_TQ

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2016 to 2022.

4WD clutch, actual pressure IONIQEV_AWD_CLU_ACT_P

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 144 to 159 of the reply, 16 bits. The value is signed.

Formula
val×19.5310000
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2016 to 2022.

4WD clutch, actual torque IONIQEV_AWD_CLU_ACT_TQ

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 N·m
Unit
N·m

In testing for 2016 to 2022.

4WD max clutch stress IONIQEV_AWD_MAX_CLU_STRESS

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×19.53110000
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

4WD pump current IONIQEV_AWD_PMP_CURRENT

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
val×78.12510000
Range
-256 to 255 A
Unit
A

In testing for 2016 to 2022.

4WD pump PWM duty IONIQEV_AWD_PMP_PWM_DUTY

  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 100 %
Unit
%

In testing for 2016 to 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2017 to 2018.

Adaptation value for lower stop of wastegate actuator IONIQEV_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2016 to 2022.

Air conditioning pressure IONIQEV_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×13.79
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2016 to 2022.

Air conditioning relay IONIQEV_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017 to 2018.

Automatic transmission fluid temperature IONIQEV_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

AUX amps LDC IONIQEV_AUX_AMPS_LDC

  • Service 21PID 02
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

In testing for 2016 to 2022.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017.

Barometric pressure IONIQEV_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2016 to 2022.

Battery management ignition IONIQEV_BAT_MANAGEMENT_IGN

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 405 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Battery management main relay IONIQEV_BAT_MANAGEMENT_MAIN

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Boost pressure IONIQEV_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2016 to 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Calculated oil temperature IONIQEV_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

Catalyst damaging misfires total all cylinders IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total all cylinders IONIQEV_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 1 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 1 IONIQEV_CATDMG_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 2 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 2 IONIQEV_CATDMG_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 3 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 3 IONIQEV_CATDMG_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 4 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 4 IONIQEV_CATDMG_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 5 IONIQEV_CATDMG_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst damaging misfires total, cylinder 6 IONIQEV_CATDMG_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2017 to 2018.

Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed

  • Service 01PID 3E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2017 to 2018.

Clutch solenoid duty IONIQEV_CLUTCH_SOLENOID_DUTY

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2022.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2017.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Commanded evaporative purge IONIQEV_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2022.

Commanded throttle actuator IONIQEV_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2022.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Commanded torque IONIQEV_COMMANDED_TORQUE

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 N·m
Unit
N·m

In testing for 2016 to 2022.

Coolant IONIQEV_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Coolant fan PWM IONIQEV_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×15.2110000
Range
0 to 99.67 %
Unit
%

In testing for 2016 to 2022.

Coolant temperature IONIQEV_HVAC_COOLANT_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2022.

Crankshaft torque IONIQEV_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2016 to 2022.

Cylinder 1 injection time, 1st pulse IONIQEV_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 1 injection time, 2nd pulse IONIQEV_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 2 injection time, 1st pulse IONIQEV_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 2 injection time, 2nd pulse IONIQEV_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 3 injection time, 1st pulse IONIQEV_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 3 injection time, 2nd pulse IONIQEV_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 4 injection time, 1st pulse IONIQEV_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Cylinder 4 injection time, 2nd pulse IONIQEV_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Diesel particulate filter differential pressure IONIQEV_DPF_DIFF_P

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val×4.3137−100
Range
-100 to 999.9935
Unit
Raw value

In testing for 2016 to 2022.

Diesel particulate filter differential pressure IONIQEV_DPF_DIFF_P_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val×431.373100
Range
0 to 1100
Unit
Raw value

In testing for 2016 to 2022.

Diesel particulate filter differential pressure IONIQEV_DPF_DIFFERENTIAL_PRESSURE

  • Service 21PID 1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5
Unit
Raw value

In testing for 2016 to 2022.

Diesel particulate filter regeneration count IONIQEV_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Diesel particulate filter regeneration state IONIQEV_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Diesel particulate filter soot mass IONIQEV_DPF_SOOT_MASS

  • Service 22DID ED94
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×99255
Range
0 to 99 g
Unit
g

In testing for 2016 to 2022.

Diesel particulate filter successful regeneration count IONIQEV_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Diesel particulate filter total sulfur mass IONIQEV_DPF_TOT_SULFUR_MASS

  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.15259
Range
0 to 9999
Unit
Raw value

In testing for 2016 to 2022.

Direct injection time 1 IONIQEV_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Direct injection time 2 IONIQEV_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Direct injection time 3 IONIQEV_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Direct injection time 4 IONIQEV_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Direct injection time 5 IONIQEV_DI_TIME_5

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Direct injection time 6 IONIQEV_DI_TIME_6

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2022.

Disconnector actuator motor current IONIQEV_DISCONNECTOR_ACTUATOR_MOTOR_CURRENT

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 A
Unit
A

In testing for 2016 to 2022.

Disconnector disengage last time IONIQEV_DISCONNECTOR_DISENGAGE_LAST_TIME

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 ms
Unit
ms

In testing for 2016 to 2022.

Disconnector end point IONIQEV_DISCONNECTOR_END_POINT

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

In testing for 2016 to 2022.

Disconnector inverter PWM duty IONIQEV_DISCONNECTOR_INVERTER_PWM_DUTY

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×78.12510000
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Disconnector meet point IONIQEV_DISCONNECTOR_MEET_POINT

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

In testing for 2016 to 2022.

Disconnector stroke position IONIQEV_DISCONNECTOR_STROKE_POSITION

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

In testing for 2016 to 2022.

Disconnector zero count offset IONIQEV_DISCONNECTOR_ZERO_COUNT_OFFSET

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2016 to 2022.

Drive motor speed IONIQEV_RPM

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Dual-clutch transmission clutch 1, pressure sensor A IONIQEV_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2022.

Dual-clutch transmission clutch 2, pressure sensor B IONIQEV_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2022.

Dual-clutch transmission fluid temperature 1 IONIQEV_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

Dual-clutch transmission fluid temperature 2 IONIQEV_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

Dual-clutch transmission line pressure, sensor C IONIQEV_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2022.

EGR error EGR_ERRSAE J1979Confirmed

  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017.

Emission relevant misfires total all cylinders IONIQEV_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total all cylinders IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 1 IONIQEV_EMIS_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 1 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 2 IONIQEV_EMIS_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 2 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 3 IONIQEV_EMIS_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 3 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 4 IONIQEV_EMIS_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 4 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 5 IONIQEV_EMIS_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission relevant misfires total, cylinder 6 IONIQEV_EMIS_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018.

Engine oil temperature IONIQEV_EOT

  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val−4
Range
-4 to 215 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Engine oil temperature IONIQEV_EOT_7E0Confirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 272 to 279 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0xA1 = 161 → 161×34−48 = 72.75 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Engine oil temperature IONIQEV_EOT_7E0_7E0

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2016 to 2022.

Engine RPM IONIQEV_RPM_7E5

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2017 to 2018.

Engine run time, total IONIQEV_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2016 to 2022.

Engine, actual torque IONIQEV_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2352910000
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2016 to 2022.

Exhaust camshaft position IONIQEV_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2022.

Exhaust gas temperature IONIQEV_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2016 to 2022.

Exhaust temperature 1, upstream of oxidation catalyst IONIQEV_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2016 to 2022.

Exhaust temperature 2, upstream of DPF IONIQEV_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2016 to 2022.

Front left tire temperature IONIQEV_FL_TT

Pelican can show this parameter as the front left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Front right tire temperature IONIQEV_FR_TT

Pelican can show this parameter as the front right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is absolute (referenced to vacuum). Meant for diesel and gasoline direct-injection systems, whose pressures exceed the range of PIDs 0A and 22.

  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017 to 2018.

Gasoline direct injection time bank a, 1 IONIQEV_GDI_IT_A1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank a, 2 IONIQEV_GDI_IT_A2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank a, 3 IONIQEV_GDI_IT_A3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank a, 4 IONIQEV_GDI_IT_A4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank b, 1 IONIQEV_GDI_IT_B1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank b, 2 IONIQEV_GDI_IT_B2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank b, 3 IONIQEV_GDI_IT_B3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Gasoline direct injection time bank b, 4 IONIQEV_GDI_IT_B4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2022.

Heat IONIQEV_HEAT

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2016 to 2022.

Heat sink temperature IONIQEV_HEAT_SINK_T

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016 to 2022.

Hv_charging IONIQEV_HV_CHG

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Idle control mode IONIQEV_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Ignition retard due to knock control 1 IONIQEV_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Ignition retard due to knock control 2 IONIQEV_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Ignition retard due to knock control 3 IONIQEV_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Ignition retard due to knock control 4 IONIQEV_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Ignition voltage IONIQEV_IGN_VOLTAGE

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1010000
Range
0 to 65.535 V
Unit
V

In testing for 2016 to 2022.

Injection duration cylinder 1 IONIQEV_INJ_DUR_1Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 s
Unit
s

0x0001 = 1 → 11220.7 = 0.000819 s

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Injection duration cylinder 2 IONIQEV_INJ_DUR_2Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 s
Unit
s

0x0001 = 1 → 11220.7 = 0.000819 s

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Injection duration cylinder 3 IONIQEV_INJ_DUR_3Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 s
Unit
s

0x0001 = 1 → 11220.7 = 0.000819 s

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Injection duration cylinder 4 IONIQEV_INJ_DUR_4Confirmed

  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1220.7
Range
0 to 53 s
Unit
s

0x0001 = 1 → 11220.7 = 0.000819 s

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Injection impulse 1, cylinder 1 IONIQEV_INJ_IMPULSE_1_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 1, cylinder 2 IONIQEV_INJ_IMPULSE_1_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 1, cylinder 3 IONIQEV_INJ_IMPULSE_1_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 1, cylinder 4 IONIQEV_INJ_IMPULSE_1_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 2, cylinder 1 IONIQEV_INJ_IMPULSE_2_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 2, cylinder 2 IONIQEV_INJ_IMPULSE_2_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 2, cylinder 3 IONIQEV_INJ_IMPULSE_2_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 2, cylinder 4 IONIQEV_INJ_IMPULSE_2_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 3, cylinder 1 IONIQEV_INJ_IMPULSE_3_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 3, cylinder 2 IONIQEV_INJ_IMPULSE_3_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 3, cylinder 3 IONIQEV_INJ_IMPULSE_3_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2016 to 2022.

Injection impulse 3, cylinder 4 IONIQEV_INJ_IMPULSE_3_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2016 to 2022.

Intake air temperature IATSAE J1979Confirmed

  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018.

Intake air temperature IONIQEV_EITConfirmed

  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 264 to 271 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

0x70 = 112 → 112×34−48 = 36 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Intake camshaft position IONIQEV_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2022.

Intake camshaft position actual IONIQEV_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2022.

Intake camshaft position commanded IONIQEV_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2016 to 2022.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017.

Inverter temperature IONIQEV_HVAC_INVERTER_T

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2022.

Inverter temperature IONIQEV_INVERTER_T

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016 to 2022.

Isolation resistance IONIQEV_ISOLATION_RES

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

In testing for 2016 to 2022.

Knock detected IONIQEV_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Knock learn, cylinder 1 IONIQEV_KNOCK_LEARN_1

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Knock learn, cylinder 2 IONIQEV_KNOCK_LEARN_2

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Knock learn, cylinder 3 IONIQEV_KNOCK_LEARN_3

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Knock learn, cylinder 4 IONIQEV_KNOCK_LEARN_4

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Knock retard cylinder #1 IONIQEV_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder #2 IONIQEV_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder #3 IONIQEV_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder #4 IONIQEV_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 1 IONIQEV_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 1, alternate IONIQEV_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 1, alternate IONIQEV_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 2 IONIQEV_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 2, alternate IONIQEV_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 2, alternate IONIQEV_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 3 IONIQEV_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 3, alternate IONIQEV_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 3, alternate IONIQEV_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 4 IONIQEV_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 4, alternate IONIQEV_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2022.

Knock retard cylinder 4, alternate IONIQEV_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2022.

Knock retard, cylinder 1 IONIQEV_KNOCK_RETARD_1Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x71 = 113 → 1135 = 22.6 °

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Knock retard, cylinder 2 IONIQEV_KNOCK_RETARD_2Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Knock retard, cylinder 3 IONIQEV_KNOCK_RETARD_3Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Knock retard, cylinder 4 IONIQEV_KNOCK_RETARD_4Confirmed

  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val5
Range
-25 to 25 °
Unit
°

0x00 = 0 → 05 = 0 °

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Lock switch IONIQEV_LOCK_SWITCH

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017 to 2018.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017 to 2018.

Main injection volume IONIQEV_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2016 to 2022.

Malfunction indicator IONIQEV_MALFUNCTION_INDICATOR

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Mass air flow rate IONIQEV_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2016 to 2022.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running IONIQEV_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2022.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop IONIQEV_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2022.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running IONIQEV_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2022.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop IONIQEV_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2022.

Misfire count #1 IONIQEV_MIS_1

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Misfire count #2 IONIQEV_MIS_2

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Misfire count #3 IONIQEV_MIS_3

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Misfire count #4 IONIQEV_MIS_4

  • Service 21PID 01
  • Module7E0 → 7D8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Misfires current total IONIQEV_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 1 IONIQEV_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 2 IONIQEV_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 3 IONIQEV_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 4 IONIQEV_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 5 IONIQEV_MIS_CURRENT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires current, cylinder 6 IONIQEV_MIS_CURRENT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst, cylinder 1 IONIQEV_MIS_HARMFUL_CAT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst, cylinder 2 IONIQEV_MIS_HARMFUL_CAT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst, cylinder 3 IONIQEV_MIS_HARMFUL_CAT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst, cylinder 4 IONIQEV_MIS_HARMFUL_CAT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, current, cylinder 1 IONIQEV_MISFIRES_C1_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, current, cylinder 2 IONIQEV_MISFIRES_C2_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, current, cylinder 3 IONIQEV_MISFIRES_C3_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, current, cylinder 4 IONIQEV_MISFIRES_C4_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 1 IONIQEV_MIS_1_7E0_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 2 IONIQEV_MIS_2_7E0_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 3 IONIQEV_MIS_3_7E0_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 4 IONIQEV_MIS_4_7E0_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Motor actual torque IONIQEV_MOTOR_ACTUAL_TORQUE

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2016 to 2022.

Motor phase current IONIQEV_MOTOR_PHASE_CURRENT_RMS

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2016 to 2022.

Motor RPM IONIQEV_MOTOR_RPM

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2016 to 2022.

Motor temperature IONIQEV_MOTOR_T

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2016 to 2022.

Motor-driven power steering current IONIQEV_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x00 = 0 → 0 A

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Nominal torque value IONIQEV_NOMINAL_TORQUE_VALUE

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

In testing for 2016 to 2022.

Operating time IONIQEV_OP_TIME

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 368 to 399 of the reply, 32 bits.

Formula
val3600
Range
0 to 1193046
Unit
Raw value

In testing for 2016 to 2022.

Overheat protection, active IONIQEV_OVERHEAT_PROTECTION

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Oxygen sensor 1 bank 1 IONIQEV_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2016 to 2022.

Oxygen sensor 2 bank 1 IONIQEV_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2016 to 2022.

Pilot injection volume IONIQEV_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2016 to 2022.

Post injection volume IONIQEV_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2016 to 2022.

Pressure sensor IONIQEV_PRESSURE_SENSOR

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 bar
Unit
bar

In testing for 2016 to 2022.

Rail pressure control valve IONIQEV_RAIL_P_CTRL_VLV

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
val×2051
Range
0 to 0.3921
Unit
Off or on

In testing for 2016 to 2022.

Rear left tire temperature IONIQEV_RL_TT

Pelican can show this parameter as the rear left tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Rear right tire temperature IONIQEV_RR_TT

Pelican can show this parameter as the rear right tire temperature.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

In testing for 2016 to 2022.

Regeneration demand counter by soot load IONIQEV_REGEN_DEMAND_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Requested torque IONIQEV_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Requested torque limitation from traction control IONIQEV_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017 to 2018.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017 to 2018.

Successful regeneration state IONIQEV_SUCCESSFUL_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 424 to 431 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2022.

Throttle position #1 IONIQEV_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2016 to 2022.

Throttle position #2 IONIQEV_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2016 to 2022.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

Confirmed for 2017.

Timing advance #1 IONIQEV_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2022.

Timing advance #2 IONIQEV_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2022.

Timing advance #3 IONIQEV_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2022.

Timing advance #4 IONIQEV_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2022.

Torque converter slip IONIQEV_TORQUE_CONVERTER_SLIP_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Torque converter slip IONIQEV_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Transmission fluid temperature IONIQEV_ATF_T_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2022.

Turbo boost pressure IONIQEV_TB_PRES

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543 kPa
Unit
kPa

In testing for 2016 to 2022.

Turbo boost pressure IONIQEV_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2016 to 2022.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2017 to 2018.

Variable valve timing temperature IONIQEV_CVVT_T

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7D8
  • Every250 ms
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Waste gate duty IONIQEV_WG_DUTY

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2016 to 2022.

Waste gate position IONIQEV_WG_POS

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2016 to 2022.

Waste gate set point IONIQEV_WG_SP

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2016 to 2022.

Waste gate voltage IONIQEV_WG_V

  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2016 to 2022.

Wastegate control PWM, wastegate actuator IONIQEV_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2016 to 2022.

Wastegate position target, wastegate actuator IONIQEV_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2016 to 2022.

Wastegate position, wastegate actuator IONIQEV_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2016 to 2022.

Misfires

Emission-relevant misfires, cylinder #1 IONIQEV_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission-relevant misfires, cylinder #2 IONIQEV_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission-relevant misfires, cylinder #3 IONIQEV_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Emission-relevant misfires, cylinder #4 IONIQEV_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst cylinder 1 IONIQEV_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst cylinder 2 IONIQEV_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst cylinder 3 IONIQEV_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires harmful for catalyst cylinder 4 IONIQEV_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires total counter, all cylinders IONIQEV_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires total counter, cylinder #1 IONIQEV_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires total counter, cylinder #2 IONIQEV_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires total counter, cylinder #3 IONIQEV_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires total counter, cylinder #4 IONIQEV_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 1 IONIQEV_MIS_1_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 2 IONIQEV_MIS_2_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 3 IONIQEV_MIS_3_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

Misfires, cylinder 4 IONIQEV_MIS_4_7E0

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2022.

OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018.

Fuel

Cycle fuel consumption IONIQEV_CYCLE_FUEL_CONS

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
val×8.478100
Range
0 to 21.6189
Unit
Raw value

In testing for 2016 to 2022.

Fuel consumption since last DPF regeneration IONIQEV_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2016 to 2022.

Fuel cut IONIQEV_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Fuel injection timing #1 IONIQEV_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2016 to 2022.

Fuel injection timing #2 IONIQEV_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2016 to 2022.

Fuel injection timing #3 IONIQEV_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2016 to 2022.

Fuel injection timing #4 IONIQEV_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2016 to 2022.

Fuel pressure IONIQEV_FUEL_P

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2016 to 2022.

Fuel pressure deviation IONIQEV_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2016 to 2022.

Fuel pressure set point IONIQEV_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2016 to 2022.

Fuel pressure set point deviation IONIQEV_FUEL_P_SET_POINT_DEV

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306610000
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2016 to 2022.

Fuel pressure, actual IONIQEV_FUEL_P_ACT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2016 to 2022.

Fuel pressure, set point IONIQEV_FUEL_P_SET_POINT_7E0

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2016 to 2022.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2017 to 2018.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2017 to 2018.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018.

Fuel temperature IONIQEV_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×784310000−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2016 to 2022.

Short term fuel % trim, bank 1 IONIQEV_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2016 to 2022.

Short term fuel % trim, bank 1 idle IONIQEV_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Lights

Brake light IONIQEV_BRAKE_LIGHT

  • Service 22DID BC06
  • Module770 → 778
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Defog light IONIQEV_DEFOG_LIGHTConfirmed

  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Hazard switch IONIQEV_HAZARD_SWConfirmed

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Headlight high beam IONIQEV_HL_HIGH

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Headlight low beam IONIQEV_HL_LOW

  • Service 22DID BC09
  • Module770 → 778
  • Every1 s
  • Testing

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Headlight switch IONIQEV_HL_SW

  • Service 22DID BC05
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Left turn signal on? IONIQEV_TURN_L

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Low beams IONIQEV_LOW_BEAMSConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Right turn signal on? IONIQEV_TURN_R

  • Service 22DID BC08
  • Module770 → 778
  • Every2 s
  • Testing

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Movement

4WD engine RPM IONIQEV_AWD_RPM

  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val2
Range
-16384 to 16383.5 bar
Unit
bar

In testing for 2016 to 2022.

Actual acceleration IONIQEV_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2016 to 2022.

Coolant fan high speed IONIQEV_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Coolant fan high speed, 1.8 IONIQEV_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Coolant fan low speed IONIQEV_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Coolant fan low speed, 1.8 IONIQEV_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2022.

Drive motor speed 1 IONIQEV_DRIVE_MOTOR_SPD_1

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2016 to 2022.

Drive motor speed 2 IONIQEV_DRIVE_MOTOR_SPD_2

  • Service 21PID 01
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2016 to 2022.

Drive motor speed, vehicle control unit IONIQEV_VMCU_MOTOR_ACT_SPD

  • Service 21PID 02
  • Module7E3 → 7EB
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016 to 2022.

Engine coolant fan high speed, on/off IONIQEV_ENG_CLT_FAN_HIGH_SPD_ON_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Engine coolant fan low speed IONIQEV_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Engine RPM IONIQEV_RPM_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Front left wheel speed IONIQEV_FL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127.5 to 127 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front left wheel speed IONIQEV_FRONT_LEFT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Front left wheel speed IONIQEV_TIRE_FL_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front left wheel speed IONIQEV_TIRE_FL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front left wheel speed IONIQEV_WHEEL_FL_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front left wheel speed, high resolution IONIQEV_WHEEL_FL_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2016 to 2022.

Front right wheel speed IONIQEV_FR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127.5 to 127 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front right wheel speed IONIQEV_FRONT_RIGHT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Front right wheel speed IONIQEV_TIRE_FR_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front right wheel speed IONIQEV_TIRE_FR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front right wheel speed IONIQEV_WHEEL_FR_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Front right wheel speed, high resolution IONIQEV_WHEEL_FR_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2016 to 2022.

Output speed IONIQEV_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Output speed IONIQEV_OUTPUT_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Rear left wheel speed IONIQEV_REAR_LEFT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Rear left wheel speed IONIQEV_RL_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127.5 to 127 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear left wheel speed IONIQEV_TIRE_RL_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear left wheel speed IONIQEV_TIRE_RL_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear left wheel speed IONIQEV_WHEEL_RL_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear left wheel speed, high resolution IONIQEV_WHEEL_RL_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2016 to 2022.

Rear right wheel speed IONIQEV_REAR_RIGHT_WHEEL_SPEED

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Rear right wheel speed IONIQEV_RR_VSS

  • Service 21PID 01
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-127.5 to 127 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear right wheel speed IONIQEV_TIRE_RR_SPD

  • Service 22DID C101
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear right wheel speed IONIQEV_TIRE_RR_VSS_V3

  • Service 22DID 4000
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear right wheel speed IONIQEV_WHEEL_RR_VSS

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Rear right wheel speed, high resolution IONIQEV_WHEEL_RR_VSS_HD

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

In testing for 2016 to 2022.

Relative accelerator pedal position IONIQEV_REL_APP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2016 to 2022.

Relative accelerator pedal position IONIQEV_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2022.

Turbine speed IONIQEV_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Turbine speed IONIQEV_TURBINE_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2016 to 2022.

Vehicle speed IONIQEV_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-180 to 180 mph
Unit
mph

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Vehicle speed IONIQEV_VSS_7B3Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x3A = 58 → 58 km/h

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Vehicle speed IONIQEV_VSS_7E1_7E1

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Vehicle speed IONIQEV_VSS_AWD

Pelican can show this parameter as the speed.

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017 to 2018.

Vehicle speed, v2 IONIQEV_VSS_V2

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2016 to 2022.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2018.

Orientation

Lateral acceleration IONIQEV_LATERAL_ACCELERATION

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.1769 to 4.1769 m/s²
Unit
m/s²

In testing for 2016 to 2022.

Longitudinal acceleration IONIQEV_LONGITUDINAL_ACCELERATION

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.1769 to 4.1769 m/s²
Unit
m/s²

In testing for 2016 to 2022.

Yaw rate IONIQEV_YAW_RATE

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 °
Unit
°

In testing for 2016 to 2022.

Seatbelts

Rear left seatbelt latched? IONIQEV_BELT_RLConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Rear middle seatbelt latched? IONIQEV_BELT_RMConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 52 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Rear right seatbelt latched? IONIQEV_BELT_RRConfirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Stats

Total drive time IONIQEV_DRIVE_TIME

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 368 to 399 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Tires

Front left tire pressure IONIQEV_FL_TP

Pelican can show this parameter as the front left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2016 to 2022.

Front left tire pressure IONIQPHEV_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2016, 2022

Example reply from a 2021 Hyundai Ioniq Electric.

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xAD = 173 → 1735 = 34.6 psi

Confirmed for 2017 to 2021. In testing for 2016, 2022.

Front left wheel speed IONIQEV_FL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Front right tire pressure IONIQEV_FR_TP

Pelican can show this parameter as the front right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2016 to 2022.

Front right tire pressure IONIQPHEV_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2016, 2022

Example reply from a 2021 Hyundai Ioniq Electric.

Bits 64 to 71 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xAD = 173 → 1735 = 34.6 psi

Confirmed for 2017 to 2021. In testing for 2016, 2022.

Front right wheel speed IONIQEV_FR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Rear left tire pressure IONIQEV_RL_TP

Pelican can show this parameter as the rear left tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2016 to 2022.

Rear left tire pressure IONIQPHEV_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2016, 2022

Example reply from a 2021 Hyundai Ioniq Electric.

Bits 128 to 135 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xAD = 173 → 1735 = 34.6 psi

Confirmed for 2017 to 2021. In testing for 2016, 2022.

Rear left wheel speed IONIQEV_RL_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Rear right tire pressure IONIQEV_RR_TP

Pelican can show this parameter as the rear right tire pressure.

  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.01378952
Range
0 to 3.51 bar
Unit
bar

In testing for 2016 to 2022.

Rear right tire pressure IONIQPHEV_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2016, 2022

Example reply from a 2021 Hyundai Ioniq Electric.

Bits 96 to 103 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xAE = 174 → 1745 = 34.8 psi

Confirmed for 2017 to 2021. In testing for 2016, 2022.

Rear right wheel speed IONIQEV_RR_WHEEL_VSS

  • Service 22DID C101
  • Module7D1 → 7D9
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016 to 2022.

Steering wheel angle IONIQEV_STEERING_WHEEL_ANGLE

  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val−88
Range
-88 to 167 °
Unit
°

In testing for 2016 to 2022.

Wheel turn angle, absolute IONIQEV_WHEEL_ANGLE_ABSConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0000 = 0 → 010 = 0 °

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Transmission

Automatic transmission fluid temperature IONIQEV_ATF_T

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Clutch #1 temperature IONIQEV_CLUTCH_1_TConfirmed

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 232 to 247 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

0x003E = 62 → 62×2−40 = 84 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Clutch #2 temperature IONIQEV_CLUTCH_2_TConfirmed

Part of the dual clutch transition

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 248 to 263 of the reply, 16 bits.

Formula
val×2−40
Range
-40 to 300 °C
Unit
°C

0x003E = 62 → 62×2−40 = 84 °C

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Commanded gear IONIQEV_COMMANDED_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Current gear IONIQEV_CURRENT_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Current gear IONIQEV_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Current gear IONIQEV_GEAR

The automatic transmission gear.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1NEUTRALNeutral
2REVERSEReverse
3PARKPark
4MANUALManual

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Current gear IONIQEV_GEAR_CURConfirmed

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 188 to 191 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

0b0000 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Drive selected IONIQEV_GEAR_D

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 44 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Dual-clutch transmission even shaft, gear engaged IONIQEV_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Dual-clutch transmission odd shaft, gear engaged IONIQEV_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Gear IONIQEV_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Gear selector IONIQEV_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2022.

Neutral selected IONIQEV_GEAR_N

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Next gear IONIQEV_GEAR_NXTConfirmed

  • Service 22DID 01A4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bits 196 to 199 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

0b0000 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Park selected IONIQEV_GEAR_P

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Reverse gear selected IONIQEV_GEAR_R_2Confirmed

  • Service 22DID BC04
  • Module770 → 778
  • Every1 s
  • Testing for 2016, 2019 to 2022

Example reply from a 2018 Hyundai Ioniq Electric.

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

0b0 = 0 → 0

Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.

Reverse selected IONIQEV_GEAR_R

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Transmission fluid temperature IONIQEV_ATF_TEMP

  • Service 22DID 21A0
  • Module7E0 → 7E8
  • Every10 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×95−40
Range
0 to 255 °F
Unit
°F

In testing for 2016 to 2022.

Vehicle speed IONIQEV_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.

Trips

Diesel particulate filter odometer at last regeneration IONIQEV_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2016 to 2022.

Distance since last DPF regeneration IONIQEV_DIST_SINCE_DPF_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 50000 km
Unit
km

In testing for 2016 to 2022.

Distance since last DPF regeneration IONIQEV_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2016 to 2022.

Odometer IONIQEV_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2016 to 2022.

Odometer IONIQEV_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2016 to 2022.

Odometer at last DPF regeneration IONIQEV_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2016 to 2022.

Odometer, km IONIQEV_ODO_KM

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2016, 2019 to 2022

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Odometer, miles IONIQEV_ODO_MI

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2016, 2019 to 2022

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.

Sensor 1 odometer event 1 IONIQEV_SENS_1_ODO_EVT_1

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 1 odometer event 2 IONIQEV_SENS_1_ODO_EVT_2

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 1 odometer event 3 IONIQEV_SENS_1_ODO_EVT_3

  • Service 22DID C00C
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 2 odometer event 1 IONIQEV_SENS_2_ODO_EVT_1

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 2 odometer event 2 IONIQEV_SENS_2_ODO_EVT_2

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 2 odometer event 3 IONIQEV_SENS_2_ODO_EVT_3

  • Service 22DID C00D
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 3 odometer event 1 IONIQEV_SENS_3_ODO_EVT_1

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 3 odometer event 2 IONIQEV_SENS_3_ODO_EVT_2

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 3 odometer event 3 IONIQEV_SENS_3_ODO_EVT_3

  • Service 22DID C00E
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 4 odometer event 1 IONIQEV_SENS_4_ODO_EVT_1

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 272 to 295 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 4 odometer event 2 IONIQEV_SENS_4_ODO_EVT_2

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 296 to 319 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Sensor 4 odometer event 3 IONIQEV_SENS_4_ODO_EVT_3

  • Service 22DID C00F
  • Module7A0 → 7A8
  • Every30 s
  • Testing

Bits 320 to 343 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721.5 km
Unit
km

In testing for 2016 to 2022.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.