Hyundai IONIQ 5

Parameters

The Hyundai IONIQ 5 has 407 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary battery voltage IONIQ5_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×4.88310000
Range
0 to 32 V
Unit
V

0x7416 = 29718 → 29718×4.88310000 = 14.511299 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

A/C charger current IONIQ5_AC_CHARGER_CURRENTConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 304 to 319 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

0x0098 = 152 → 152100 = 1.52 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

A/C charging counter IONIQ5_HVBAT_AC_CHARGING_COUNTERConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x000F = 15 → 15

Confirmed for 2022 to 2026. In testing for 2018, 2021.

A/C charging time IONIQ5_VCMS__AC_CHARGING_TIMEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

0x00A3 = 163 → 163 h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

A/C charging time, after plug-in IONIQ5_AC_CHARGING_TIME_AFTER_PLUG_INConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x001D = 29 → 29 min

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Auxiliary battery current IONIQ5_2025_AUX_BATTERY_CURRENTConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 144 to 159 of the reply, 16 bits.

Formula
val100−327
Range
-327 to 328.35 A
Unit
A

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Auxiliary battery current IONIQ5_AUX_BATTERY_CURRENTConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 144 to 159 of the reply, 16 bits.

Formula
val100−327
Range
-327 to 328.35 A
Unit
A

0x7C4D = 31821 → 31821100−327 = -8.79 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Auxiliary battery state of charge IONIQ5_2025_AUX_BATTERY_STATE_OF_CHARGEConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Auxiliary battery state of charge IONIQ5_AUX_BATTERY_STATE_OF_CHARGEConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x53 = 83 → 83 %

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Auxiliary battery temperature IONIQ5_2025_AUX_BATTERY_TConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 184 to 199 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727.5 °C
Unit
°C

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Auxiliary battery temperature IONIQ5_AUX_BATTERY_TConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 184 to 199 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727.5 °C
Unit
°C

0x004C = 76 → 762−40 = -2 °C

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Auxiliary battery voltage IONIQ5_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×4.88310000
Range
0 to 32 V
Unit
V

0x7416 = 29718 → 29718×4.88310000 = 14.511299 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Auxiliary battery voltage IONIQ5_2025_AUX_BATTERY_VOLTAGEConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 168 to 183 of the reply, 16 bits.

Formula
val1000+6
Range
6 to 71.535 V
Unit
V

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Auxiliary battery voltage IONIQ5_AUX_BATTERY_VOLTAGE_7E5Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 168 to 183 of the reply, 16 bits.

Formula
val1000+6
Range
6 to 71.535 V
Unit
V

0x18A8 = 6312 → 63121000+6 = 12.312 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Auxiliary battery voltage IONIQ5_AUXILLARY_BATTERY_VOLTAGEConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val10
Range
11 to 14.6 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery current IONIQ5_BATTERY_CURRENTConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery DC voltage IONIQ5_BATTERY_DC_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery fan feedback IONIQ5_BATTERY_FAN_FEEDBACKConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 120 Hz
Unit
Hz

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery fan status IONIQ5_BATTERY_FAN_STATUSConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery inlet temperature IONIQ5_BATTERY_INLET_TConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery management system ignition IONIQ5_BMS_IGNITIONConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bit 405 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery management system main relay IONIQ5_BMS_MAIN_RELAYConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery max temperature IONIQ5_BATTERY_MAX_TConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery min temperature IONIQ5_BATTERY_MIN_TConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B01 IONIQ5_BATTERY_PACK_B01Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B02 IONIQ5_BATTERY_PACK_B02Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B03 IONIQ5_BATTERY_PACK_B03Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B04 IONIQ5_BATTERY_PACK_B04Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B05 IONIQ5_BATTERY_PACK_B05Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B17 IONIQ5_BATTERY_PACK_B17Confirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

0x18 = 24 → 24 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery pack B18 IONIQ5_BATTERY_PACK_B18Confirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 80 °C
Unit
°C

0x18 = 24 → 24 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery work time total IONIQ5_BATTERY_WORK_TIME_TOTAL_SECConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 368 to 399 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Charge mode A/C maximum current limit IONIQ5_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Charge mode DC maximum current limit IONIQ5_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Charge mode DC target voltage IONIQ5_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Charging? IONIQ5_HV_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bit 72 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Control pilot duty cycle IONIQ5_HVBAT_CP_DUTY_CYCLEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 56 to 71 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x00FE = 254 → 25410 = 25.4 %

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Control pilot voltage IONIQ5_HVBAT_CP_VOLTAGEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x3C = 60 → 6010 = 6 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Cumulative charge current IONIQ5_CUMULATIVE_CHARGE_CURRENTConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 271 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Cumulative DC charging time IONIQ5_DC_CHRG_TIMEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

0x0000 = 0 → 0 h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Cumulative discharge current IONIQ5_CUMULATIVE_DISCHARGE_CURRENTConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 303 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Cumulative energy charged IONIQ5_CUMULATIVE_ENERGY_CHARGEDConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 304 to 335 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Cumulative energy discharged IONIQ5_CUMULATIVE_ENERGY_DISCHARGEDConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 336 to 367 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 kWh
Unit
kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC charger current capability IONIQ5_DC_CHARGER_CURRENT_CAPABILITYConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 320 to 335 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC charging counter IONIQ5_HVBAT_CHRG_CNTConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0001 = 1 → 1

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC charging time, after plug-in IONIQ5_DC_CHARGING_TIME_AFTER_PLUG_INConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

0x0000 = 0 → 0 min

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Discharge mode A/C maximum current limit IONIQ5_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x00 = 0 → 0 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Discharge mode A/C target voltage IONIQ5_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGEConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

0x00 = 0 → 0 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Discharge mode DC maximum current limit IONIQ5_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed

  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x32 = 50 → 50 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Electric oil pump, actual speed IONIQ5_EOP_ACTUAL_SPEEDConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric oil pump, commanded speed IONIQ5_EOP_COMMANDED_SPEEDConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val×20
Range
0 to 5100 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric oil pump, current DC IONIQ5_EOP_CURRENT_DCConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric oil pump, current IQ IONIQ5_EOP_CURRENT_IQConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, target current IONIQ5_HVBAT_TARGET_CURRConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 144 to 159 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, target voltage IONIQ5_HVBAT_TARGET_VOLTConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 128 to 143 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric water pump, actual rotation speed IONIQ5_EWP_ACTUAL_ROTATION_SPEEDConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric water pump, commanded rotation speed IONIQ5_EWP_COMMANDED_ROTATION_SPEEDConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val×24
Range
0 to 6120 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric water pump, current DC IONIQ5_EWP_CURRENT_DCConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric water pump, voltage DC IONIQ5_EWP_VOLTAGE_DCConfirmed

  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, max current IONIQ5_HVBAT_EV_MAX_CURRENTConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 176 to 191 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0DAC = 3500 → 350010 = 350 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, max voltage IONIQ5_HVBAT_EV_MAX_VOLTAGEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 160 to 175 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x2040 = 8256 → 825610 = 825.6 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, state of charge IONIQ5_HVBAT_SOC_VCMSConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 120 to 127 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x9E = 158 → 1582 = 79 %

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, target current IONIQ5_HVBAT_BMS_TARGET_CURRENTConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 208 to 223 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0192 = 402 → 40210 = 40.2 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, target voltage IONIQ5_HVBAT_BMS_TARGET_VOLTAGEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 192 to 207 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x2040 = 8256 → 825610 = 825.6 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

High voltage battery, voltage IONIQ5_HVBAT_HV_BATTERY_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 104 to 119 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x1E0D = 7693 → 769310 = 769.3 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

HV battery charge IONIQ5_HVBAT_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2018, 2021.

HV battery charge, dashboard IONIQ5_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2018, 2021.

HV battery remaining energy IONIQ5_HVBAT_WHConfirmed

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 239 of the reply, 16 bits.

Formula
val×21000
Range
0 to 131.07 kWh
Unit
kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

HV battery state of health IONIQ5_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 215 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Inverter capacitor voltage IONIQ5_INVERTER_CAPACITOR_VOLTAGEConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 408 to 423 of the reply, 16 bits.

Formula
val
Range
0 to 1000 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Isolation resistance IONIQ5_ISOLATION_RESISTANCEConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 3000 kΩ
Unit
kΩ

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Low-voltage dc-dc converter, input voltage IONIQ5_2025_LDC_INPUT_VOLTAGEConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Low-voltage dc-dc converter, input voltage IONIQ5_LDC_INPUT_VOLTAGEConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 112 to 127 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x01B8 = 440 → 44010 = 44 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Low-voltage dc-dc converter, output current IONIQ5_2025_LDC_OUTPUT_CURRENTConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 96 to 111 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 A
Unit
A

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Low-voltage dc-dc converter, output current IONIQ5_LDC_OUTPUT_CURRENTConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 96 to 111 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 A
Unit
A

0x0000 = 0 → 0×101000 = 0 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Low-voltage dc-dc converter, output voltage IONIQ5_2025_LDC_OUTPUT_VOLTAGEConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Low-voltage dc-dc converter, output voltage IONIQ5_LDC_OUTPUT_VOLTAGEConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x301F = 12319 → 123191000 = 12.319 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Low-voltage dc-dc converter, temperature IONIQ5_2025_LDC_TConfirmed

  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s

Bits 72 to 79 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

Confirmed for 2025 to 2026. Not supported for 2022 to 2023.

Low-voltage dc-dc converter, temperature IONIQ5_LDC_TConfirmed

  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−100
Range
-100 to 155 °C
Unit
°C

0x66 = 102 → 102−100 = 2 °C

Confirmed for 2022 to 2024. In testing for 2018, 2021. Not supported for 2025.

Maximum cell voltage IONIQ5_MAXIMUM_CELL_VOLTAGEConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Maximum cell voltage no IONIQ5_MAXIMUM_CELL_VOLTAGE_NOConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Minimum cell voltage IONIQ5_MINIMUM_CELL_VOLTAGEConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
2.8 to 4.2 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Minimum cell voltage no IONIQ5_MINIMUM_CELL_VOLTAGE_NOConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Normal charge port IONIQ5_NORMAL_CHARGE_PORTConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bit 74 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Normal charging energy, total IONIQ5_NORMAL_CHARGING_ENERGY_TOTConfirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

0x00000032 = 50 → 50 kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Normal charging, count IONIQ5_NORMAL_CHARGING_COUNTConfirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000003 = 3 → 3

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Proximity detection voltage IONIQ5_HVBAT_PD_VOLTAGEConfirmed

  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 103 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 V
Unit
V

0x05D4 = 1492 → 1492×1010000 = 1.492 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Quick charging energy, total IONIQ5_QUICK_CHARGING_ENERGY_TOTConfirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

0x00000004 = 4 → 4 kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Quick charging, count IONIQ5_QUICK_CHARGING_COUNTConfirmed

  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000001 = 1 → 1

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rapid charge port IONIQ5_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bit 73 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Charging

400V relay on/off request IONIQ5_400V_RELAY_ON_OFF_REQUESTConfirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 43 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

400V relay status IONIQ5_400V_RELAY_STATUSConfirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

AC charging state IONIQ5_AC_CHRG_STATEConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 141 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2022 to 2026. In testing for 2018, 2021.

AC inlet temperature 1 IONIQ5_AC_INLET_T_1Confirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 87 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x48 = 72 → 72−50 = 22 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Auxiliary battery voltage IONIQ5_AUX_BATTERY_VOLTAGEConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 103 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

0x05B6 = 1462 → 1462100 = 14.62 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Battery main relay status IONIQ5_BATTERY_MAIN_RELAY_STATUSConfirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 37 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b1 = 1 → 1

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Charging socket connected IONIQ5_CHARGING_SOCKET_CONNECTEDConfirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 38 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC charging state IONIQ5_DC_CHRG_STATEConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bit 140 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC inlet temperature 1 IONIQ5_DC_INLET_T_1Confirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x45 = 69 → 69−50 = 19 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DC inlet temperature 2 IONIQ5_DC_INLET_T_2Confirmed

  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

0x45 = 69 → 69−50 = 19 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, current IONIQ5_EVSE_CConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, current, max IONIQ5_EVSE_MAXIMUM_CURRENT_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, current, min IONIQ5_EVSE_MINIMUM_CURRENT_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 120 to 135 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, power, delivered IONIQ5_EVSE_DELIVERED_POWER_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 184 to 199 of the reply, 16 bits.

Formula
val×101000
Range
0 to 655.35 kWh
Unit
kWh

0x0000 = 0 → 0×101000 = 0 kWh

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, power, main IONIQ5_EVSE_MAIN_POWERConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

0x00 = 0 → 0 kW

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, power, max IONIQ5_EVSE_MAXIMUM_POWER_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 200 to 215 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 W
Unit
W

0x0000 = 0 → 0×10 = 0 W

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, regulation tolerance IONIQ5_EVSE_CURRENT_REGULATION_TOLERANCE_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 176 to 183 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 A
Unit
A

0x00 = 0 → 0−50 = -50 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, voltage IONIQ5_EVSE_VConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 136 to 151 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, voltage, max IONIQ5_EVSE_MAXIMUM_VOLTAGE_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 72 to 87 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0FA0 = 4000 → 400010 = 400 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Electric vehicle supply equipment, voltage, min IONIQ5_EVSE_MINIMUM_VOLTAGE_VALUEConfirmed

  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 104 to 119 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Estimated charging power IONIQ5_ESTIMATED_CHRG_POWERConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 224 to 239 of the reply, 16 bits.

Formula
val×10−50
Range
-50 to 655300 W
Unit
W

0x0118 = 280 → 280×10−50 = 2,750 W

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC current a IONIQ5_OBC_AC_CURRENT_A_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC current b IONIQ5_OBC_AC_CURRENT_B_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 120 to 135 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC frequency IONIQ5_OBC_AC_FREQUENCYConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 Hz
Unit
Hz

0x00 = 0 → 0 Hz

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC input current sensor a signal voltage IONIQ5_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGEConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 296 to 311 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

0x0000 = 0 → 0100 = 0 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

On-board charger, AC input current sensor b signal voltage IONIQ5_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGEConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 312 to 327 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

0x0000 = 0 → 0100 = 0 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

On-board charger, AC total current IONIQ5_OBC_AC_TOTAL_CURRENT_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 103 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC voltage a IONIQ5_OBC_AC_VOLTAGE_A_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, AC voltage b IONIQ5_OBC_AC_VOLTAGE_B_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0700 = 1792 → 179210 = 179.2 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, charge mode DC target current IONIQ5_OBC_CHARGE_MODE_DC_TARGET_CURRENTConfirmed

  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0000 = 0 → 010 = 0 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

On-board charger, charge mode DC target voltage IONIQ5_OBC_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed

  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0AC7 = 2759 → 275910 = 275.9 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

On-board charger, charging AC current IONIQ5_OBC_CHRG_AC_CURRENTConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 184 to 199 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0098 = 152 → 15210 = 15.2 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, charging AC voltage IONIQ5_OBC_CHRG_AC_VOLTAGEConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

0x00 = 0 → 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, charging DC current IONIQ5_OBC_CHRG_DC_CURRENTConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 168 to 183 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x00D2 = 210 → 21010 = 21 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, charging DC voltage IONIQ5_OBC_CHRG_DC_VOLTAGEConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x2040 = 8256 → 825610 = 825.6 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, DC current a IONIQ5_OBC_DC_CURRENT_A_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 184 to 199 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, DC current b IONIQ5_OBC_DC_CURRENT_B_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, DC current total IONIQ5_OBC_DC_CURRENT_TOTAL_RMSConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, DC voltage IONIQ5_OBC_DC_VOLTAGEConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 152 to 167 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0000 = 0 → 010 = 0 V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, discharging AC current IONIQ5_OBC_DCHRG_AC_CURRENTConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x00 = 0 → 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, discharging DC current IONIQ5_OBC_DCHRG_DC_CURRENTConfirmed

  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x25 = 37 → 37 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, temperature a IONIQ5_OBC_T_AConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 216 to 223 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

On-board charger, temperature b IONIQ5_OBC_T_BConfirmed

  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 224 to 231 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 001

HV battery module 001 voltage IONIQ5_HVBAT_CMU001_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 002

HV battery module 002 voltage IONIQ5_HVBAT_CMU002_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 003

HV battery module 003 voltage IONIQ5_HVBAT_CMU003_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 004

HV battery module 004 voltage IONIQ5_HVBAT_CMU004_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 005

HV battery module 005 voltage IONIQ5_HVBAT_CMU005_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 006

HV battery module 006 voltage IONIQ5_HVBAT_CMU006_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 007

HV battery module 007 voltage IONIQ5_HVBAT_CMU007_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 008

HV battery module 008 voltage IONIQ5_HVBAT_CMU008_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 009

HV battery module 009 voltage IONIQ5_HVBAT_CMU009_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 010

HV battery module 010 voltage IONIQ5_HVBAT_CMU010_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 011

HV battery module 011 voltage IONIQ5_HVBAT_CMU011_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 012

HV battery module 012 voltage IONIQ5_HVBAT_CMU012_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 013

HV battery module 013 voltage IONIQ5_HVBAT_CMU013_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 014

HV battery module 014 voltage IONIQ5_HVBAT_CMU014_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 015

HV battery module 015 voltage IONIQ5_HVBAT_CMU015_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 016

HV battery module 016 voltage IONIQ5_HVBAT_CMU016_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 017

HV battery module 017 voltage IONIQ5_HVBAT_CMU017_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 018

HV battery module 018 voltage IONIQ5_HVBAT_CMU018_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 019

HV battery module 019 voltage IONIQ5_HVBAT_CMU019_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 020

HV battery module 020 voltage IONIQ5_HVBAT_CMU020_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 021

HV battery module 021 voltage IONIQ5_HVBAT_CMU021_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 022

HV battery module 022 voltage IONIQ5_HVBAT_CMU022_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 023

HV battery module 023 voltage IONIQ5_HVBAT_CMU023_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 024

HV battery module 024 voltage IONIQ5_HVBAT_CMU024_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 025

HV battery module 025 voltage IONIQ5_HVBAT_CMU025_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 026

HV battery module 026 voltage IONIQ5_HVBAT_CMU026_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 027

HV battery module 027 voltage IONIQ5_HVBAT_CMU027_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 028

HV battery module 028 voltage IONIQ5_HVBAT_CMU028_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 029

HV battery module 029 voltage IONIQ5_HVBAT_CMU029_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 030

HV battery module 030 voltage IONIQ5_HVBAT_CMU030_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 031

HV battery module 031 voltage IONIQ5_HVBAT_CMU031_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 032

HV battery module 032 voltage IONIQ5_HVBAT_CMU032_VOLTConfirmed

  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 033

HV battery module 033 voltage IONIQ5_HVBAT_CMU033_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 034

HV battery module 034 voltage IONIQ5_HVBAT_CMU034_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 035

HV battery module 035 voltage IONIQ5_HVBAT_CMU035_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 036

HV battery module 036 voltage IONIQ5_HVBAT_CMU036_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 037

HV battery module 037 voltage IONIQ5_HVBAT_CMU037_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 038

HV battery module 038 voltage IONIQ5_HVBAT_CMU038_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 039

HV battery module 039 voltage IONIQ5_HVBAT_CMU039_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 040

HV battery module 040 voltage IONIQ5_HVBAT_CMU040_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 041

HV battery module 041 voltage IONIQ5_HVBAT_CMU041_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 042

HV battery module 042 voltage IONIQ5_HVBAT_CMU042_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 043

HV battery module 043 voltage IONIQ5_HVBAT_CMU043_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 044

HV battery module 044 voltage IONIQ5_HVBAT_CMU044_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 045

HV battery module 045 voltage IONIQ5_HVBAT_CMU045_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 046

HV battery module 046 voltage IONIQ5_HVBAT_CMU046_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 047

HV battery module 047 voltage IONIQ5_HVBAT_CMU047_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 048

HV battery module 048 voltage IONIQ5_HVBAT_CMU048_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 049

HV battery module 049 voltage IONIQ5_HVBAT_CMU049_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 050

HV battery module 050 voltage IONIQ5_HVBAT_CMU050_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 051

HV battery module 051 voltage IONIQ5_HVBAT_CMU051_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 052

HV battery module 052 voltage IONIQ5_HVBAT_CMU052_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 053

HV battery module 053 voltage IONIQ5_HVBAT_CMU053_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 054

HV battery module 054 voltage IONIQ5_HVBAT_CMU054_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 055

HV battery module 055 voltage IONIQ5_HVBAT_CMU055_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 056

HV battery module 056 voltage IONIQ5_HVBAT_CMU056_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 057

HV battery module 057 voltage IONIQ5_HVBAT_CMU057_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 058

HV battery module 058 voltage IONIQ5_HVBAT_CMU058_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 059

HV battery module 059 voltage IONIQ5_HVBAT_CMU059_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 060

HV battery module 060 voltage IONIQ5_HVBAT_CMU060_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 061

HV battery module 061 voltage IONIQ5_HVBAT_CMU061_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 062

HV battery module 062 voltage IONIQ5_HVBAT_CMU062_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 063

HV battery module 063 voltage IONIQ5_HVBAT_CMU063_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 064

HV battery module 064 voltage IONIQ5_HVBAT_CMU064_VOLTConfirmed

  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 065

HV battery module 065 voltage IONIQ5_HVBAT_CMU065_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 066

HV battery module 066 voltage IONIQ5_HVBAT_CMU066_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 067

HV battery module 067 voltage IONIQ5_HVBAT_CMU067_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 068

HV battery module 068 voltage IONIQ5_HVBAT_CMU068_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 069

HV battery module 069 voltage IONIQ5_HVBAT_CMU069_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 070

HV battery module 070 voltage IONIQ5_HVBAT_CMU070_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 071

HV battery module 071 voltage IONIQ5_HVBAT_CMU071_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 072

HV battery module 072 voltage IONIQ5_HVBAT_CMU072_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 073

HV battery module 073 voltage IONIQ5_HVBAT_CMU073_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 074

HV battery module 074 voltage IONIQ5_HVBAT_CMU074_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 075

HV battery module 075 voltage IONIQ5_HVBAT_CMU075_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 076

HV battery module 076 voltage IONIQ5_HVBAT_CMU076_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 077

HV battery module 077 voltage IONIQ5_HVBAT_CMU077_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 078

HV battery module 078 voltage IONIQ5_HVBAT_CMU078_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 079

HV battery module 079 voltage IONIQ5_HVBAT_CMU079_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 080

HV battery module 080 voltage IONIQ5_HVBAT_CMU080_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 081

HV battery module 081 voltage IONIQ5_HVBAT_CMU081_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 082

HV battery module 082 voltage IONIQ5_HVBAT_CMU082_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 083

HV battery module 083 voltage IONIQ5_HVBAT_CMU083_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 084

HV battery module 084 voltage IONIQ5_HVBAT_CMU084_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 085

HV battery module 085 voltage IONIQ5_HVBAT_CMU085_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 086

HV battery module 086 voltage IONIQ5_HVBAT_CMU086_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 087

HV battery module 087 voltage IONIQ5_HVBAT_CMU087_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 088

HV battery module 088 voltage IONIQ5_HVBAT_CMU088_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 089

HV battery module 089 voltage IONIQ5_HVBAT_CMU089_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 090

HV battery module 090 voltage IONIQ5_HVBAT_CMU090_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 091

HV battery module 091 voltage IONIQ5_HVBAT_CMU091_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 092

HV battery module 092 voltage IONIQ5_HVBAT_CMU092_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 093

HV battery module 093 voltage IONIQ5_HVBAT_CMU093_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 094

HV battery module 094 voltage IONIQ5_HVBAT_CMU094_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 095

HV battery module 095 voltage IONIQ5_HVBAT_CMU095_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 096

HV battery module 096 voltage IONIQ5_HVBAT_CMU096_VOLTConfirmed

  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 097

HV battery module 097 voltage IONIQ5_HVBAT_CMU097_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 098

HV battery module 098 voltage IONIQ5_HVBAT_CMU098_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 099

HV battery module 099 voltage IONIQ5_HVBAT_CMU099_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 100

HV battery module 100 voltage IONIQ5_HVBAT_CMU100_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 101

HV battery module 101 voltage IONIQ5_HVBAT_CMU101_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 102

HV battery module 102 voltage IONIQ5_HVBAT_CMU102_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 103

HV battery module 103 voltage IONIQ5_HVBAT_CMU103_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 104

HV battery module 104 voltage IONIQ5_HVBAT_CMU104_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 105

HV battery module 105 voltage IONIQ5_HVBAT_CMU105_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 106

HV battery module 106 voltage IONIQ5_HVBAT_CMU106_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 107

HV battery module 107 voltage IONIQ5_HVBAT_CMU107_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 108

HV battery module 108 voltage IONIQ5_HVBAT_CMU108_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 109

HV battery module 109 voltage IONIQ5_HVBAT_CMU109_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 110

HV battery module 110 voltage IONIQ5_HVBAT_CMU110_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 111

HV battery module 111 voltage IONIQ5_HVBAT_CMU111_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 112

HV battery module 112 voltage IONIQ5_HVBAT_CMU112_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 113

HV battery module 113 voltage IONIQ5_HVBAT_CMU113_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 114

HV battery module 114 voltage IONIQ5_HVBAT_CMU114_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 115

HV battery module 115 voltage IONIQ5_HVBAT_CMU115_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 116

HV battery module 116 voltage IONIQ5_HVBAT_CMU116_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 117

HV battery module 117 voltage IONIQ5_HVBAT_CMU117_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 118

HV battery module 118 voltage IONIQ5_HVBAT_CMU118_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 119

HV battery module 119 voltage IONIQ5_HVBAT_CMU119_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 120

HV battery module 120 voltage IONIQ5_HVBAT_CMU120_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 121

HV battery module 121 voltage IONIQ5_HVBAT_CMU121_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 122

HV battery module 122 voltage IONIQ5_HVBAT_CMU122_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 123

HV battery module 123 voltage IONIQ5_HVBAT_CMU123_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 124

HV battery module 124 voltage IONIQ5_HVBAT_CMU124_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 125

HV battery module 125 voltage IONIQ5_HVBAT_CMU125_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 126

HV battery module 126 voltage IONIQ5_HVBAT_CMU126_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 127

HV battery module 127 voltage IONIQ5_HVBAT_CMU127_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 128

HV battery module 128 voltage IONIQ5_HVBAT_CMU128_VOLTConfirmed

  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 129

HV battery module 129 voltage IONIQ5_HVBAT_CMU129_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 130

HV battery module 130 voltage IONIQ5_HVBAT_CMU130_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 131

HV battery module 131 voltage IONIQ5_HVBAT_CMU131_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 132

HV battery module 132 voltage IONIQ5_HVBAT_CMU132_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 133

HV battery module 133 voltage IONIQ5_HVBAT_CMU133_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 134

HV battery module 134 voltage IONIQ5_HVBAT_CMU134_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 135

HV battery module 135 voltage IONIQ5_HVBAT_CMU135_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 136

HV battery module 136 voltage IONIQ5_HVBAT_CMU136_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 137

HV battery module 137 voltage IONIQ5_HVBAT_CMU137_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 138

HV battery module 138 voltage IONIQ5_HVBAT_CMU138_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 139

HV battery module 139 voltage IONIQ5_HVBAT_CMU139_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 140

HV battery module 140 voltage IONIQ5_HVBAT_CMU140_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 141

HV battery module 141 voltage IONIQ5_HVBAT_CMU141_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 142

HV battery module 142 voltage IONIQ5_HVBAT_CMU142_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 143

HV battery module 143 voltage IONIQ5_HVBAT_CMU143_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 144

HV battery module 144 voltage IONIQ5_HVBAT_CMU144_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 145

HV battery module 145 voltage IONIQ5_HVBAT_CMU145_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 146

HV battery module 146 voltage IONIQ5_HVBAT_CMU146_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 147

HV battery module 147 voltage IONIQ5_HVBAT_CMU147_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 148

HV battery module 148 voltage IONIQ5_HVBAT_CMU148_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 149

HV battery module 149 voltage IONIQ5_HVBAT_CMU149_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 150

HV battery module 150 voltage IONIQ5_HVBAT_CMU150_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 151

HV battery module 151 voltage IONIQ5_HVBAT_CMU151_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 152

HV battery module 152 voltage IONIQ5_HVBAT_CMU152_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 153

HV battery module 153 voltage IONIQ5_HVBAT_CMU153_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 154

HV battery module 154 voltage IONIQ5_HVBAT_CMU154_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 155

HV battery module 155 voltage IONIQ5_HVBAT_CMU155_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 156

HV battery module 156 voltage IONIQ5_HVBAT_CMU156_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 157

HV battery module 157 voltage IONIQ5_HVBAT_CMU157_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 158

HV battery module 158 voltage IONIQ5_HVBAT_CMU158_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 159

HV battery module 159 voltage IONIQ5_HVBAT_CMU159_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 160

HV battery module 160 voltage IONIQ5_HVBAT_CMU160_VOLTConfirmed

  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 161

HV battery module 161 voltage IONIQ5_HVBAT_CMU161_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 162

HV battery module 162 voltage IONIQ5_HVBAT_CMU162_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 163

HV battery module 163 voltage IONIQ5_HVBAT_CMU163_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 164

HV battery module 164 voltage IONIQ5_HVBAT_CMU164_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 165

HV battery module 165 voltage IONIQ5_HVBAT_CMU165_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 64 to 71 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 166

HV battery module 166 voltage IONIQ5_HVBAT_CMU166_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 72 to 79 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 167

HV battery module 167 voltage IONIQ5_HVBAT_CMU167_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 80 to 87 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 168

HV battery module 168 voltage IONIQ5_HVBAT_CMU168_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 88 to 95 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 169

HV battery module 169 voltage IONIQ5_HVBAT_CMU169_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 96 to 103 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 170

HV battery module 170 voltage IONIQ5_HVBAT_CMU170_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 104 to 111 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 171

HV battery module 171 voltage IONIQ5_HVBAT_CMU171_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 112 to 119 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 172

HV battery module 172 voltage IONIQ5_HVBAT_CMU172_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 120 to 127 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 173

HV battery module 173 voltage IONIQ5_HVBAT_CMU173_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 128 to 135 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 174

HV battery module 174 voltage IONIQ5_HVBAT_CMU174_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 136 to 143 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 175

HV battery module 175 voltage IONIQ5_HVBAT_CMU175_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 176

HV battery module 176 voltage IONIQ5_HVBAT_CMU176_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 152 to 159 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 177

HV battery module 177 voltage IONIQ5_HVBAT_CMU177_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 160 to 167 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 178

HV battery module 178 voltage IONIQ5_HVBAT_CMU178_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 168 to 175 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 179

HV battery module 179 voltage IONIQ5_HVBAT_CMU179_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 176 to 183 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 180

HV battery module 180 voltage IONIQ5_HVBAT_CMU180_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 184 to 191 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 181

HV battery module 181 voltage IONIQ5_HVBAT_CMU181_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 192 to 199 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 182

HV battery module 182 voltage IONIQ5_HVBAT_CMU182_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 183

HV battery module 183 voltage IONIQ5_HVBAT_CMU183_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 208 to 215 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 184

HV battery module 184 voltage IONIQ5_HVBAT_CMU184_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 185

HV battery module 185 voltage IONIQ5_HVBAT_CMU185_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 186

HV battery module 186 voltage IONIQ5_HVBAT_CMU186_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 187

HV battery module 187 voltage IONIQ5_HVBAT_CMU187_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 240 to 247 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 188

HV battery module 188 voltage IONIQ5_HVBAT_CMU188_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 248 to 255 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 189

HV battery module 189 voltage IONIQ5_HVBAT_CMU189_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 256 to 263 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 190

HV battery module 190 voltage IONIQ5_HVBAT_CMU190_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 264 to 271 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 191

HV battery module 191 voltage IONIQ5_HVBAT_CMU191_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 272 to 279 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Modules › 192

HV battery module 192 voltage IONIQ5_HVBAT_CMU192_VOLTConfirmed

  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 280 to 287 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Climate

A/C compressor operation RPM IONIQ5_AC_COMPRESSOR_OPERATION_RPMConfirmed

  • Service 22DID 0114
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 208 to 223 of the reply, 16 bits.

Formula
val×20
Range
0 to 1310700 rpm
Unit
rpm

0x0000 = 0 → 0×20 = 0 rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Evaporator temperature IONIQ5_HVAC_EVAPORATOR_TConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 56 to 63 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Heated steering wheel IONIQ5_HEATED_WHEELConfirmed

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2018, 2021, 2025 to 2026

Example reply from a 2024 Hyundai IONIQ 5.

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2024. In testing for 2018, 2021, 2026. Not supported for 2025.

Heated steering wheel, alternate bit IONIQ5_HEATED_WHEEL_ALTConfirmed

  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing for 2018, 2021, 2025 to 2026

Example reply from a 2024 Hyundai IONIQ 5.

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2024. In testing for 2018, 2021, 2026. Not supported for 2025.

Humidity sensor for automatic defogger IONIQ5_HVAC_HUMIDITY_SENSOR_FOR_AUTOMATIC_DEFOGGERConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Interior temperature, driver legs vent IONIQ5_HVAC_IAT_DRIVER_LEGS_VENTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 224 to 231 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Interior temperature, driver vent IONIQ5_HVAC_IAT_DRIVER_VENTConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 216 to 223 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Interior temperature, front IONIQ5_HVAC_IATConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 40 to 47 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Interior temperature, passenger legs vent IONIQ5_HVAC_IAT_PASSENGER_LEGS_VENTConfirmed

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 72 to 79 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x64 = 100 → 1002−40 = 10 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Interior temperature, passenger vent IONIQ5_HVAC_IAT_PASSENGER_VENTConfirmed

  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x63 = 99 → 992−40 = 9.5 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Outdoor temperature IONIQ5_HVAC_AATConfirmed

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Control

Accelerator pedal depth IONIQ5_ACCEL_PEDAL_DEPTH

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2018, 2021. Not supported for 2022 to 2026.

Accelerator pedal position IONIQ5_ACCELERATOR_PEDAL_POSITIONConfirmed

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val512
Range
0 to 100 %
Unit
%

0x2A17 = 10775 → 10775512 = 21.044922 %

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Brake lamp status IONIQ5_BRAKE_LAMP_STATUS

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 55 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Brake switch IONIQ5_BRAKE_SWConfirmed

  • Service 22DID B008
  • Module7A0 → 7A8
  • Every1 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bit 51 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Brakes applied IONIQ5_BRAKES_APPLIED

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 54 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Steering wheel angle IONIQ5_STEERING_ANGLEConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 96 to 111 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

Confirmed for 2022 to 2026. In testing for 2018, 2021.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2025. Supported for 2018, 2022 to 2024, 2026.

Engine

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2018, 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025.

Coolant temperature IONIQ5_HVAC_COOLANT_TConfirmed

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0xAB = 171 → 1712−40 = 45.5 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector actuator motor current IONIQ5_DISCONNECTOR_ACTUATOR_MOTOR_CURRENTConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val×2
Range
-256 to 254 A
Unit
A

0x00 = 0 → 0×2 = 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector disengage last time IONIQ5_DISCONNECTOR_DISENGAGE_LAST_TIMEConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 ms
Unit
ms

0x00 = 0 → 0 ms

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector end point IONIQ5_DISCONNECTOR_END_POINTConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

0xFF80 = 65408 → 65408128 = 511 mm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector inverter PWM duty IONIQ5_DISCONNECTOR_INVERTER_PWM_DUTYConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×78.12510000
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×78.12510000 = 0 %

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector meet point IONIQ5_DISCONNECTOR_MEET_POINTConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

0xFF80 = 65408 → 65408128 = 511 mm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector stroke position IONIQ5_DISCONNECTOR_STROKE_POSITIONConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val128
Range
0 to 511 mm
Unit
mm

0x0000 = 0 → 0128 = 0 mm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Disconnector zero count offset IONIQ5_DISCONNECTOR_ZERO_COUNT_OFFSETConfirmed

  • Service 22DID E005
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767
Unit
Number

0x0000 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2018, 2023.

Heat sink temperature IONIQ5_HEAT_SINK_TConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

0x0649 = 1609 → 1609100 = 16.09 °C

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Ignition voltage IONIQ5_IGN_VOLTAGEConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1010000
Range
0 to 65.535 V
Unit
V

0x38FC = 14588 → 14588×1010000 = 14.588 V

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Inverter temperature IONIQ5_HVAC_INVERTER_TConfirmed

  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 103 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x27 = 39 → 392−40 = -20.5 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Inverter temperature IONIQ5_INVERTER_TConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

0x071D = 1821 → 1821100 = 18.21 °C

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Motor actual torque IONIQ5_MOTOR_ACTUAL_TORQUEConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

0x0119 = 281 → 28110 = 28.1 N·m

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Motor phase current IONIQ5_MOTOR_PHASE_CURRENT_RMSConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 A
Unit
A

0x0107 = 263 → 26310 = 26.3 A

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Motor RPM IONIQ5_MOTOR_RPMConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

0x0FEA = 4074 → 4,074 rpm

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Motor temperature IONIQ5_MOTOR_TConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

0x0787 = 1927 → 1927100 = 19.27 °C

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Motor-driven power steering current IONIQ5_MDPS_MOTOR_CURRENTConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

0x00 = 0 → 0 A

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Nominal torque value IONIQ5_NOMINAL_TORQUE_VALUEConfirmed

  • Service 22DID E001
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2024 Hyundai IONIQ 5.

Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val10
Range
-3276.8 to 3276.7 N·m
Unit
N·m

0x0119 = 281 → 28110 = 28.1 N·m

Confirmed for 2022 to 2024. In testing for 2018, 2021. Supported for 2025 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2025. Supported for 2018, 2023.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2025. Supported for 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2025. Supported for 2018.

Fuel

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2018.

Lights

Brake light IONIQ5_BRAKE_LIGHTConfirmed

  • Service 22DID BC06
  • Module770 → 778
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Exterior lights state code IONIQ5_LIGHTS_CODEConfirmed

  • Service 22DID BC10
  • Module770 → 778
  • Every5 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 32 to 35 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

0b0000 = 0 → 0

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Low beams IONIQ5_LOW_BEAMSConfirmed

  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2022 to 2025. In testing for 2018, 2021. Not supported for 2026.

Movement

Drive motor speed 1 IONIQ5_DRIVE_MOTOR_SPEED_1Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 424 to 439 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Drive motor speed 2 IONIQ5_DRIVE_MOTOR_SPEED_2Confirmed

  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2018, 2021

Bits 440 to 455 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front left wheel speed IONIQ5_WHEEL_FL_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front left wheel speed, high resolution IONIQ5_WHEEL_FL_VSS_HDConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front right wheel speed IONIQ5_WHEEL_FR_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front right wheel speed, high resolution IONIQ5_WHEEL_FR_VSS_HDConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear left wheel speed IONIQ5_WHEEL_RL_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear left wheel speed, high resolution IONIQ5_WHEEL_RL_VSS_HDConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear right wheel speed IONIQ5_WHEEL_RR_VSSConfirmed

  • Service 22DID 0104
  • Module7D1 → 7D9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear right wheel speed, high resolution IONIQ5_WHEEL_RR_VSS_HDConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val32
Range
0 to 2047 km/h
Unit
km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Vehicle speed IONIQ5_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2018, 2021

Bits 232 to 239 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Vehicle speed IONIQ5_VSS_VMCU

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

In testing for 2018, 2021. Not supported for 2022 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. Supported for 2018, 2023.

Vehicle speed, high resolution IONIQ5_VSS_HDConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×156.2510000
Range
-512 to 511 km/h
Unit
km/h

0x0EC8 = 3784 → 3784×156.2510000 = 59.125 km/h

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Orientation

Lateral acceleration IONIQ5_LATERAL_ACCELERATIONConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.177 to 4.177 m/s²
Unit
m/s²

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Longitudinal acceleration IONIQ5_LONGITUDINAL_ACCELERATIONConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×8.35465535−4.177
Range
-4.177 to 4.177 m/s²
Unit
m/s²

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Yaw rate IONIQ5_YAW_RATEConfirmed

  • Service 22DID F010
  • Module730 → 738
  • Every250 ms
  • Testing for 2018, 2021

Bits 144 to 151 of the reply, 8 bits.

Formula
val200
Range
0 to 1.275 °
Unit
°

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Tires

Front left tire pressure IONIQ5_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 32 to 39 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xB1 = 177 → 1775 = 35.4 psi

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front left tire temperature IONIQ5_TT_FLConfirmed

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 40 to 47 of the reply, 8 bits.

Formula
val−50
Range
-40 to 65 °C
Unit
°C

0x53 = 83 → 83−50 = 33 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front right tire pressure IONIQ5_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 72 to 79 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xB4 = 180 → 1805 = 36 psi

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Front right tire temperature IONIQ5_TT_FRConfirmed

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 80 to 87 of the reply, 8 bits.

Formula
val−50
Range
-40 to 65 °C
Unit
°C

0x53 = 83 → 83−50 = 33 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear left tire pressure IONIQ5_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 112 to 119 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xAF = 175 → 1755 = 35 psi

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear left tire temperature IONIQ5_TT_RLConfirmed

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 120 to 127 of the reply, 8 bits.

Formula
val−50
Range
-40 to 65 °C
Unit
°C

0x52 = 82 → 82−50 = 32 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear right tire pressure IONIQ5_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 152 to 159 of the reply, 8 bits.

Formula
val5
Range
0 to 51 psi
Unit
psi

0xB2 = 178 → 1785 = 35.6 psi

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Rear right tire temperature IONIQ5_TT_RRConfirmed

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID C00B
  • Module7A0 → 7A8
  • Every15 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 160 to 167 of the reply, 8 bits.

Formula
val−50
Range
-40 to 65 °C
Unit
°C

0x52 = 82 → 82−50 = 32 °C

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Tire sensor 1 ID IONIQ5_TID_1Confirmed

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

0x181735D6 = 404174294 → 404,174,294

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Tire sensor 2 ID IONIQ5_TID_2Confirmed

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 64 to 95 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

0x181735D0 = 404174288 → 404,174,288

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Tire sensor 3 ID IONIQ5_TID_3Confirmed

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 96 to 127 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

0x18174DCE = 404180430 → 404,180,430

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Tire sensor 4 ID IONIQ5_TID_4Confirmed

  • Service 22DID C002
  • Module7A0 → 7A8
  • Every60 s
  • Testing for 2018, 2021, 2026

Example reply from a 2025 Hyundai IONIQ 5.

Bits 128 to 159 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

0x18174EC1 = 404180673 → 404,180,673

Confirmed for 2022 to 2025. In testing for 2018, 2021, 2026.

Wheel turn angle, absolute IONIQ5_WHEEL_ANGLE_ABSConfirmed

  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °
Unit
°

0x0000 = 0 → 010 = 0 °

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Transmission

Gear position D IONIQ5_GEAR_D

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 44 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Gear position N IONIQ5_GEAR_N

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 45 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Gear position P IONIQ5_GEAR_P

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Gear position R IONIQ5_GEAR_R

  • Service 21PID 01
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2022 to 2026.

Trips

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2025.

Odometer, imperial IONIQ5_ODO_MIConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 mi
Unit
mi

0x001405 = 5125 → 5,125 mi

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Odometer, metric IONIQ5_ODO_KMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2018, 2021

Example reply from a 2026 Hyundai IONIQ 5.

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x000000 = 0 → 0 km

Confirmed for 2022 to 2026. In testing for 2018, 2021.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.