Hyundai HB20S

Parameters

The Hyundai HB20S has 327 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission fluid temperature HB20S_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery temperature HB20S_12V_BAT_T

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2013 to 2026.

12V battery voltage HB20S_12V_BAT_V

  • Service 22DID ED08
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2013 to 2026.

Battery capacity, battery sensor HB20S_BAT_CAP_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2013 to 2026.

Battery charge flag, battery sensor HB20S_BAT_CHG_FLAG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Battery current HB20S_BAT_CURRENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
val×100010000
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2013 to 2026.

Battery current, battery sensor HB20S_BAT_CURRENT_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

In testing for 2013 to 2026.

Battery current, battery sensor HB20S_BAT_CURRENT_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 736 to 751 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val16
Range
-2048 to 2047.9375 A
Unit
A

In testing for 2013 to 2026.

Battery current, battery sensor HB20S_BAT_CURRENT_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2013 to 2026.

Battery health aging flag, battery sensor HB20S_BAT_HEALTH_AGING

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Battery is in use to crank the engine flag, battery sensor HB20S_BAT_CRANK_ENG_FLAG

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Battery quiescent current flag, battery sensor HB20S_BAT_QUIESCENT

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Battery sensor invalid condition flag, battery sensor HB20S_BATSENS_INVALID_COND

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Battery state of charge, battery sensor HB20S_BAT_ST_CHG_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Battery state of charge, battery sensor HB20S_BAT_ST_CHG_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 784 to 791 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Battery state of charge, battery sensor HB20S_BAT_ST_CHG_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Battery state of function, battery sensor HB20S_BAT_ST_FUNCTION

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×12.75255
Range
0 to 12.75 V
Unit
V

In testing for 2013 to 2026.

Battery state of health, battery sensor HB20S_BAT_ST_HEALTH

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Battery state of health, battery sensor HB20S_BAT_ST_HEALTH_BATSENS

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2013 to 2026.

Battery temperature HB20S_BAT_T

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 °C
Unit
°C

In testing for 2013 to 2026.

Battery temperature, battery sensor HB20S_BAT_T_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2013 to 2026.

Battery temperature, battery sensor HB20S_BAT_T_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 768 to 783 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1953250000
Range
-255.9836 to 255.9758 °C
Unit
°C

In testing for 2013 to 2026.

Battery temperature, battery sensor HB20S_BAT_T_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val2−40
Range
-40 to 32727 °C
Unit
°C

In testing for 2013 to 2026.

Battery voltage HB20S_BAT_V

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val×1010000+6
Range
0 to 71.535 V
Unit
V

In testing for 2013 to 2026.

Battery voltage, battery sensor HB20S_BAT_V_BATSENS

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×12.75255+6
Range
0 to 18.75 V
Unit
V

In testing for 2013 to 2026.

Battery voltage, battery sensor HB20S_BAT_V_BATSENS_7E0_7E0_06

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 752 to 767 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×3265535
Range
0 to 32 V
Unit
V

In testing for 2013 to 2026.

Battery voltage, battery sensor HB20S_BAT_V_BATSENS_7E0_7E0_27

  • Service 21PID 27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000+6
Range
0 to 71.53 V
Unit
V

In testing for 2013 to 2026.

Control module voltage HB20S_CONTROL_MODULE_VOLTAGEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

0xAD = 173 → 173 V

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Control module voltage after ignition HB20S_CONTROL_MODULE_VOLTAGE_AFTER_IGNITIONConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

0x00 = 0 → 0 V

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Coolant temperature sensor voltage HB20S_COOLANT_T_SENSOR_VOLTAGEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Dual-clutch transmission control module voltage HB20S_DUAL_CLU_TRANS_CTRL_V

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val13.6
Range
0 to 18.75 V
Unit
V

In testing for 2013 to 2026.

Gasoline particulate filter charge state HB20S_GPF_CHG_ST

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Gasoline particulate filter inlet temperature sensor raw voltage HB20S_GPF_INLET_T_SENS_RAW_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2013 to 2026.

Gasoline particulate filter outlet temperature sensor raw voltage HB20S_GPF_OUTLET_T_SENS_V

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×213334369000
Range
0 to 319 V
Unit
V

In testing for 2013 to 2026.

IAT sensor voltage HB20S_IAT_SENSOR_VOLTAGEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Manifold absolute pressure sensor voltage HB20S_MAP_SENSOR_VOLTAGEConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0048828125
Range
0 to 319 V
Unit
V

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Relative accelerator pedal position voltage HB20S_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val5
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2013 to 2026.

Response error from battery sensor flag, battery sensor HB20S_RESPONSE_ERROR

  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Throttle position sensor voltage #1 HB20S_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2013 to 2026.

Throttle position sensor voltage #2 HB20S_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0012207031
Range
0 to 79 V
Unit
V

In testing for 2013 to 2026.

Waste gate voltage HB20S_WASTE_GATE_V

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val×0.000152588
Range
0 to 9.99 V
Unit
V

In testing for 2013 to 2026.

Wastegate position voltage HB20S_WASTEGATE_POS_V

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2013 to 2026.

Control

Brake booster pressure HB20S_BRAKE_BOOSTER_P

  • Service 22DID E013
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val25
Range
-1310 to 1310
Unit
Raw value

In testing for 2013 to 2026.

Brake pedal HB20S_BRAKE_PEDALConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xC0 = 192 → 192

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Brake pedal HB20S_BRAKE_PEDAL_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Relative accelerator pedal position HB20S_APP_REL_TCMConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017.

Engine

Adaptation value for lower stop of wastegate actuator HB20S_ADPT_LO_STOP

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×1.5310000
Range
-5.01 to 5.01 V
Unit
V

In testing for 2013 to 2026.

Air conditioning pressure HB20S_AC_P

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×13.79
Range
0 to 3516.45 kPa
Unit
kPa

In testing for 2013 to 2026.

Air conditioning relay HB20S_AC_RELAY

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Automatic transmission fluid temperature HB20S_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x44 = 68 → 68−40 = 28 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Automatic transmission fluid temperature HB20S_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Barometric pressure HB20S_BAROMETRIC_PRESSURE

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2013 to 2026.

Boost pressure HB20S_BOOST_P

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2013 to 2026.

Boost pressure upstream HB20S_BOOST_P_UP

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2013 to 2026.

Boost pressure upstream, desired HB20S_BOOST_P_UP_DES

  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×39500
Range
0 to 5111
Unit
Raw value

In testing for 2013 to 2026.

Butane in liquefied petroleum gas HB20S_BUTANE_LPG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Calculated oil temperature HB20S_CALC_OIL_T

  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Camshaft exhaust position, actual HB20S_CAM_EXH_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2013 to 2026.

Camshaft exhaust position, commanded HB20S_CAM_EXH_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×-38−40
Range
-135 to -40 °
Unit
°

In testing for 2013 to 2026.

Camshaft intake position, actual HB20S_CAM_INT_POS_ACT

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2013 to 2026.

Camshaft intake position, commanded HB20S_CAM_INT_POS_CMD

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×38+60
Range
0 to 155 °
Unit
°

In testing for 2013 to 2026.

Catalyst damaging misfires total all cylinders HB20S_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total all cylinders HB20S_CATDMG_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 1 HB20S_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 1 HB20S_CATDMG_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 2 HB20S_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 2 HB20S_CATDMG_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 3 HB20S_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 3 HB20S_CATDMG_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 4 HB20S_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 4 HB20S_CATDMG_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 5 HB20S_CATDMG_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Catalyst damaging misfires total, cylinder 6 HB20S_CATDMG_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Commanded evaporative purge HB20S_COMMANDED_EVAPORATIVE_PURGE

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2013 to 2026.

Commanded throttle actuator HB20S_COMMANDED_THROTTLE_ACTUATOR

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2013 to 2026.

Coolant HB20S_COOLANT_FAN

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Coolant fan PWM HB20S_CLT_FAN_PWM

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×15.2110000
Range
0 to 99.67 %
Unit
%

In testing for 2013 to 2026.

Coverage driven length HB20S_COVERAGE_DRIVEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Crankshaft torque HB20S_CRANK_TQ

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×600255
Range
0 to 600 N·m
Unit
N·m

In testing for 2013 to 2026.

Cylinder 1 injection time, 1st pulse HB20S_CYL_1_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 1 injection time, 2nd pulse HB20S_CYL_1_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 2 injection time, 1st pulse HB20S_CYL_2_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 2 injection time, 2nd pulse HB20S_CYL_2_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 3 injection time, 1st pulse HB20S_CYL_3_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 3 injection time, 2nd pulse HB20S_CYL_3_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 4 injection time, 1st pulse HB20S_CYL_4_INJ_TIME_1ST

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Cylinder 4 injection time, 2nd pulse HB20S_CYL_4_INJ_TIME_2ND

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×41000
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Diesel particulate filter differential pressure HB20S_DPF_DIFF_P

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
val×431.373100−100
Range
-100 to 1000
Unit
Raw value

In testing for 2013 to 2026.

Diesel particulate filter differential pressure HB20S_DPF_DIFF_P_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
val×431.373100
Range
0 to 1100
Unit
Raw value

In testing for 2013 to 2026.

Diesel particulate filter regeneration count HB20S_DPF_REGEN_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Diesel particulate filter regeneration state HB20S_DPF_REGENERATION_STATE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Diesel particulate filter successful regeneration count HB20S_DPF_SUCCESSFUL_REGEN

  • Service 22DID E0F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Direct injection time 1 HB20S_DI_TIME_1

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Direct injection time 2 HB20S_DI_TIME_2

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Direct injection time 3 HB20S_DI_TIME_3

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Direct injection time 4 HB20S_DI_TIME_4

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Direct injection time 5 HB20S_DI_TIME_5

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Direct injection time 6 HB20S_DI_TIME_6

  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×10013107
Range
0 to 500 ms
Unit
ms

In testing for 2013 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a HB20S_DUAL_CLU_TRANS_CLU_1_P

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2013 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b HB20S_DUAL_CLU_TRANS_CLU_2_P_B

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2013 to 2026.

Dual-clutch transmission fluid temperature 1 HB20S_DUAL_CLU_ATF_T_1

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Dual-clutch transmission fluid temperature 2 HB20S_DUAL_CLU_ATF_T_2

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Dual-clutch transmission line pressure, sensor c HB20S_DUAL_CLU_TRANS_LINE_P_C

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val×19.5310000
Range
0 to 127 bar
Unit
bar

In testing for 2013 to 2026.

Emission relevant misfires total all cylinders HB20S_EMIS_MIS_TOT_ALL

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total all cylinders HB20S_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 1 HB20S_EMIS_MIS_TOT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 1 HB20S_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 2 HB20S_EMIS_MIS_TOT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 2 HB20S_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 3 HB20S_EMIS_MIS_TOT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 3 HB20S_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 4 HB20S_EMIS_MIS_TOT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 4 HB20S_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 5 HB20S_EMIS_MIS_TOT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission relevant misfires total, cylinder 6 HB20S_EMIS_MIS_TOT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Engine coolant temperature HB20S_ENGINE_COOLANT_TConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 200 to 207 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

0x66 = 102 → 102×0.75−48 = 28.5 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Engine oil temperature HB20S_ENGINE_OIL_TConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 272 to 279 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

0x66 = 102 → 102×0.75−48 = 28.5 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Engine oil temperature HB20S_EOT_7E0

  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×0.7843−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2013 to 2026.

Engine RPM HB20S_ENGINE_RPM_TCMConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Engine run time, total HB20S_ENG_RUN_TIME_TOT

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393209.9999 min
Unit
min

In testing for 2013 to 2026.

Engine running time total HB20S_ENG_RUNNING_TIME_TOT

  • Service 22DID E00E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6
Range
0 to 393210 min
Unit
min

In testing for 2013 to 2026.

Engine, actual torque HB20S_ENG_ACT_TQ

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×2352910000
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2013 to 2026.

Exhaust cam oil control valve duty HB20S_OIL_CTRL_VLV_IMPULSE_WIDTH

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Exhaust camshaft position HB20S_EXH_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2013 to 2026.

Exhaust gas temperature HB20S_EXHAUST_GAS_T

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val×4.709803922+99
Range
99 to 1300 °C
Unit
°C

In testing for 2013 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 1 HB20S_EXH_GAS_T_BEFORE_GPF_1

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2013 to 2026.

Exhaust gas temperature before gasoline particulate filter sensor 2 HB20S_EXH_GAS_T_BEFORE_GPF_2

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×12125
Range
0 to 6291 °C
Unit
°C

In testing for 2013 to 2026.

Exhaust gas volume flow HB20S_EXH_GAS_VOLUME_FLOW

  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×7844910000
Range
0 to 2000
Unit
Raw value

In testing for 2013 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst HB20S_EXH_T_1_UP_OXICAT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2013 to 2026.

Exhaust temperature 2, upstream of DPF HB20S_EXH_T_2_UP_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
val×4.7098+99
Range
0 to 1299.999 °C
Unit
°C

In testing for 2013 to 2026.

Gasoline direct injection time bank a, 1 HB20S_GDI_IT_A1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank a, 2 HB20S_GDI_IT_A2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank a, 3 HB20S_GDI_IT_A3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank a, 4 HB20S_GDI_IT_A4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank b, 1 HB20S_GDI_IT_B1

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank b, 2 HB20S_GDI_IT_B2

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank b, 3 HB20S_GDI_IT_B3

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Gasoline direct injection time bank b, 4 HB20S_GDI_IT_B4

  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553.5 ms
Unit
ms

In testing for 2013 to 2026.

Idle control mode HB20S_IDLE_CONTROL_MODE

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Ignition retard due to knock control 1 HB20S_IGN_RETARD_KNOCK_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Ignition retard due to knock control 2 HB20S_IGN_RETARD_KNOCK_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Ignition retard due to knock control 3 HB20S_IGN_RETARD_KNOCK_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Ignition retard due to knock control 4 HB20S_IGN_RETARD_KNOCK_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Injection impulse 1, cylinder 1 HB20S_INJ_IMPULSE_1_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 1, cylinder 2 HB20S_INJ_IMPULSE_1_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 1, cylinder 3 HB20S_INJ_IMPULSE_1_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 1, cylinder 4 HB20S_INJ_IMPULSE_1_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 2, cylinder 1 HB20S_INJ_IMPULSE_2_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 2, cylinder 2 HB20S_INJ_IMPULSE_2_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 2, cylinder 3 HB20S_INJ_IMPULSE_2_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 2, cylinder 4 HB20S_INJ_IMPULSE_2_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val250
Range
0 to 262.14 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 3, cylinder 1 HB20S_INJ_IMPULSE_3_CYL_1

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 3, cylinder 2 HB20S_INJ_IMPULSE_3_CYL_2

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 3, cylinder 3 HB20S_INJ_IMPULSE_3_CYL_3

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2013 to 2026.

Injection impulse 3, cylinder 4 HB20S_INJ_IMPULSE_3_CYL_4

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val25
Range
0 to 2621.4 ms
Unit
ms

In testing for 2013 to 2026.

Injector correction factor 1 HB20S_INJ_CORR_FACTOR_1

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2013 to 2026.

Injector correction factor 2 HB20S_INJ_CORR_FACTOR_2

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2013 to 2026.

Injector correction factor 3 HB20S_INJ_CORR_FACTOR_3

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2013 to 2026.

Injector correction factor 4 HB20S_INJ_CORR_FACTOR_4

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×265535
Range
0 to 2
Unit
Number

In testing for 2013 to 2026.

Intake air temperature HB20S_INTAKE_AIR_TConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 264 to 271 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

0x65 = 101 → 101×0.75−48 = 27.75 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Intake cam oil control valve duty HB20S_OIL_CTRL_VLV_IMPULSE

  • Service 21PID 20
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Intake camshaft position HB20S_INT_CAM_POS

  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2013 to 2026.

Intake camshaft position actual HB20S_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val128
Range
-256 to 255 °
Unit
°

In testing for 2013 to 2026.

Intake camshaft position commanded HB20S_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val2
Range
-64 to 63.5 °
Unit
°

In testing for 2013 to 2026.

Intake manifold absolute pressure HB20S_INTAKE_MANIFOLD_ABSOLUTE_PRESSUREConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val256
Range
0 to 255 kPa
Unit
kPa

0x2E0C = 11788 → 11788256 = 46.046875 kPa

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Knock detected HB20S_KNOCK_DETECTED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Knock retard cylinder #1 HB20S_KNOCK_RETARD_CYLINDER_1

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder #2 HB20S_KNOCK_RETARD_CYLINDER_2

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder #3 HB20S_KNOCK_RETARD_CYLINDER_3

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder #4 HB20S_KNOCK_RETARD_CYLINDER_4

  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 1 HB20S_KNOCK_RETARD_CYL_1

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 1, alternate HB20S_KNOCK_RETARD_1_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 1, alternate HB20S_KNOCK_RETARD_CYL_1_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 2 HB20S_KNOCK_RETARD_CYL_2

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 2, alternate HB20S_KNOCK_RETARD_2_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 2, alternate HB20S_KNOCK_RETARD_CYL_2_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 3 HB20S_KNOCK_RETARD_CYL_3

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 3, alternate HB20S_KNOCK_RETARD_3_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 3, alternate HB20S_KNOCK_RETARD_CYL_3_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 4 HB20S_KNOCK_RETARD_CYL_4

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 4, alternate HB20S_KNOCK_RETARD_4_E019

  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val×0.75−191.25
Range
-191.25 to 0 °
Unit
°

In testing for 2013 to 2026.

Knock retard cylinder 4, alternate HB20S_KNOCK_RETARD_CYL_4_ALT

  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val1.333333333
Range
0 to 191.25 °
Unit
°

In testing for 2013 to 2026.

Liquefied petroleum gas low side temperature HB20S_LPG_LOW_SIDE_T

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143 °C
Unit
°C

In testing for 2013 to 2026.

Main injection volume HB20S_MAIN_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×0.392156863
Range
0 to 100 L
Unit
L

In testing for 2013 to 2026.

Mass air flow rate HB20S_MAF_RATE

  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
val×0.04239
Range
0 to 10.8
Unit
Raw value

In testing for 2013 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running HB20S_MAX_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2013 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop HB20S_MAX_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2013 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running HB20S_MIN_ADPT_LO_MECH_STOP_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2013 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop HB20S_MIN_ADPT_LO_MECH_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×1.5310000
Range
0 to 10.02 V
Unit
V

In testing for 2013 to 2026.

Misfires current total HB20S_MIS_CURRENT_TOT

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 1 HB20S_MIS_CURRENT_1

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 2 HB20S_MIS_CURRENT_2

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 3 HB20S_MIS_CURRENT_3

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 4 HB20S_MIS_CURRENT_4

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 5 HB20S_MIS_CURRENT_5

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires current, cylinder 6 HB20S_MIS_CURRENT_6

  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst, cylinder 1 HB20S_MIS_HARMFUL_CAT_1

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst, cylinder 2 HB20S_MIS_HARMFUL_CAT_2

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst, cylinder 3 HB20S_MIS_HARMFUL_CAT_3

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst, cylinder 4 HB20S_MIS_HARMFUL_CAT_4

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, current, cylinder 1 HB20S_MISFIRES_C1_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, current, cylinder 2 HB20S_MISFIRES_C2_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, current, cylinder 3 HB20S_MISFIRES_C3_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, current, cylinder 4 HB20S_MISFIRES_C4_CUR

  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 1 HB20S_MIS_1_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 2 HB20S_MIS_2_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 3 HB20S_MIS_3_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 4 HB20S_MIS_4_7E0

  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Oil pump PWM HB20S_OIL_PMP_PWM

  • Service 22DID ED13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val×2051
Range
0 to 0.392
Unit
Off or on

In testing for 2013 to 2026.

Output speed HB20S_OUTPUT_SPEEDConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Overheat protection, active HB20S_OVERHEAT_PROTECTION

  • Service 22DID E014
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 132 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Oxygen sensor 1 bank 1 HB20S_OXYGEN_SENSOR_11

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2013 to 2026.

Oxygen sensor 2 bank 1 HB20S_OXYGEN_SENSOR_21

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val×0.00521−0.2
Range
-0.2 to 1.12 V
Unit
V

In testing for 2013 to 2026.

Pilot injection volume HB20S_PILOT_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2013 to 2026.

Post injection volume HB20S_POST_INJECTION_QTY

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2013 to 2026.

Rail pressure control valve HB20S_RAIL_P_CTRL_VLV

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 55 of the reply.

Formula
val×2051
Range
0 to 0.3921
Unit
Off or on

In testing for 2013 to 2026.

Regeneration demand counter by soot load HB20S_REGEN_DEMAND_CNT

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Requested torque HB20S_REQUESTED_TORQUE

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val×0.001526
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Requested torque limitation from traction control HB20S_REQ_TQ_LIM_TRACTION

  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Successful regeneration state HB20S_SUCCESSFUL_REGEN_ST

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 424 to 431 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2013 to 2026.

Throttle position #1 HB20S_THROTTLE_POSITION__1

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2013 to 2026.

Throttle position #2 HB20S_THROTTLE_POSITION__2

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.0244140625
Range
-800 to 799 %
Unit
%

In testing for 2013 to 2026.

Timing advance #1 HB20S_TIMING_ADVANCE_1

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2013 to 2026.

Timing advance #2 HB20S_TIMING_ADVANCE_2

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2013 to 2026.

Timing advance #3 HB20S_TIMING_ADVANCE_3

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2013 to 2026.

Timing advance #4 HB20S_TIMING_ADVANCE_4

  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2013 to 2026.

Torque converter slip HB20S_TORQUE_CONVERTER_SLIPConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

0x0800 = 2048 → 20484−512 = 0 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Torque converter slip HB20S_TORQUE_CONVERTER_SLIP_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Torque converter slip HB20S_TQ_CONV_SLIP

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Torque, actual HB20S_TQ_ACT

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×6140000
Range
0 to 99.94 %
Unit
%

In testing for 2013 to 2026.

Total sulfur mass HB20S_TOT_SULFUR_MASS

  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15259100000
Range
0 to 9999
Unit
Raw value

In testing for 2013 to 2026.

Transmission fluid temperature HB20S_ATF_T_7E0

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2013 to 2026.

Turbine speed HB20S_TURBINE_SPEEDConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Turbo boost pressure HB20S_TURBO_BOOST_P

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×829.110000
Range
0 to 5433
Unit
Raw value

In testing for 2013 to 2026.

Turbo boost pressure HB20S_TURBO_BOOST_P_7E0

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×0.008291
Range
0 to 543
Unit
Number

In testing for 2013 to 2026.

Variable valve timing temperature HB20S_CVVT_TConfirmed

Continuously variable valve timing temperature.

  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 272 to 279 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

0x00 = 0 → 0−48 = -48 °C

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Waste gate duty HB20S_WASTE_GATE_DUTY

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val×0.00305176
Range
0 to 199 %
Unit
%

In testing for 2013 to 2026.

Waste gate position HB20S_WASTE_GATE_POS

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2013 to 2026.

Waste gate target HB20S_WASTE_GATE_TGT

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val×0.00610352
Range
0 to 399 %
Unit
%

In testing for 2013 to 2026.

Wastegate control PWM, wastegate actuator HB20S_WASTEGATE_CTRL_PWM

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×10032767
Range
-100 to 100 %
Unit
%

In testing for 2013 to 2026.

Wastegate position target, wastegate actuator HB20S_WASTEGATE_POS_TGT

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2013 to 2026.

Wastegate position, wastegate actuator HB20S_WASTEGATE_POS

  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×20032767
Range
-200 to 200 %
Unit
%

In testing for 2013 to 2026.

Misfires

Emission-relevant misfires, cylinder #1 HB20S_MIS_CNT_EMIS_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission-relevant misfires, cylinder #2 HB20S_MIS_CNT_EMIS_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission-relevant misfires, cylinder #3 HB20S_MIS_CNT_EMIS_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Emission-relevant misfires, cylinder #4 HB20S_MIS_CNT_EMIS_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst cylinder 1 HB20S_MIS_CAT_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst cylinder 2 HB20S_MIS_CAT_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst cylinder 3 HB20S_MIS_CAT_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires harmful for catalyst cylinder 4 HB20S_MIS_CAT_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires total counter, all cylinders HB20S_MIS_CNT_ALL

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires total counter, cylinder #1 HB20S_MIS_CNT_1

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires total counter, cylinder #2 HB20S_MIS_CNT_2

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires total counter, cylinder #3 HB20S_MIS_CNT_3

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires total counter, cylinder #4 HB20S_MIS_CNT_4

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 1 HB20S_MIS_1

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 2 HB20S_MIS_2

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 3 HB20S_MIS_3

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Misfires, cylinder 4 HB20S_MIS_4

  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2013 to 2026.

Fuel

Cycle fuel consumption HB20S_CYCLE_FUEL_CONS

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 423 of the reply, 8 bits.

Formula
val×8.478100
Range
0 to 21.6189
Unit
Raw value

In testing for 2013 to 2026.

Fuel consumption since last DPF regeneration HB20S_FUEL_CONS_SINCE_DPF

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val×1.2549
Range
0 to 319 L
Unit
L

In testing for 2013 to 2026.

Fuel cut HB20S_FUEL_CUT

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Fuel injection timing #1 HB20S_FUEL_INJECTION_TIMING_1

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2013 to 2026.

Fuel injection timing #2 HB20S_FUEL_INJECTION_TIMING_2

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2013 to 2026.

Fuel injection timing #3 HB20S_FUEL_INJECTION_TIMING_3

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2013 to 2026.

Fuel injection timing #4 HB20S_FUEL_INJECTION_TIMING_4

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.8192
Range
0 to 53686.272 ms
Unit
ms

In testing for 2013 to 2026.

Fuel level input HB20S_FLI_INPUT

  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 L
Unit
L

In testing for 2013 to 2026.

Fuel pressure HB20S_FUEL_P

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2013 to 2026.

Fuel pressure deviation HB20S_FUEL_P_DEV

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306710000
Range
-173889.9456 to 173884.6389
Unit
Raw value

In testing for 2013 to 2026.

Fuel pressure set point HB20S_FUEL_P_SET_POINT

  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2013 to 2026.

Fuel pressure set point deviation HB20S_FUEL_P_SET_POINT_DEV

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×5306610000
Range
-173886.6688 to 173881.3622
Unit
Raw value

In testing for 2013 to 2026.

Fuel pressure, actual HB20S_FUEL_P_ACT

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2013 to 2026.

Fuel pressure, set point HB20S_FUEL_P_SET_POINT_7E0

  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×5306710000
Range
0 to 347774.5845
Unit
Raw value

In testing for 2013 to 2026.

Fuel rail low pressure HB20S_FUEL_RAIL_LOW_P

  • Service 22DID E006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val10
Range
0 to 6553 kPa
Unit
kPa

In testing for 2013 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2017.

Fuel temperature HB20S_FUEL_T

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val×784310000−50
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2013 to 2026.

Liquefied petroleum gas electrical fuel pump PWM HB20S_LPG_ELECTRICAL_FUEL

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Liquefied petroleum gas pressure in fuel rail, average HB20S_LPG_P_FUEL_RAIL_AVG

  • Service 21PID 22
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val2
Range
0 to 32767
Unit
Raw value

In testing for 2013 to 2026.

Short term fuel % trim, bank 1 HB20S_STFT_B1

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val×0.0030517578−100
Range
0 to 99.99 %
Unit
%

In testing for 2013 to 2026.

Short term fuel % trim, bank 1 idle HB20S_STFT_B1_IDLE

  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val×0.046875
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Movement

Actual acceleration HB20S_ACT_ACCEL

  • Service 22DID ED04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
val×64255
Range
0 to 64 m/s²
Unit
m/s²

In testing for 2013 to 2026.

Commanded engine idle RPM HB20S_COMMANDED_ENGINE_IDLE_RPMConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 72 to 79 of the reply, 8 bits.

Formula
val×10
Range
0 to 2550 rpm
Unit
rpm

0x8D = 141 → 141×10 = 1,410 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Coolant fan high speed HB20S_COOLANT_FAN_HIGH_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Coolant fan high speed, 1.8 HB20S_COOLANT_FAN_HIGH_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 109 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Coolant fan low speed HB20S_COOLANT_FAN_LOW_SPEED

  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Coolant fan low speed, 1.8 HB20S_COOLANT_FAN_LOW_SPEED_1_8

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 110 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2026.

Dual-clutch transmission engine RPM HB20S_DUAL_CLU_TRANS_RPM

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

In testing for 2013 to 2026.

Dual-clutch transmission vehicle speed HB20S_DUAL_CLU_TRANS_VSS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2026.

Engine coolant fan high speed, on/off HB20S_ENG_CLT_FAN_HIGH_SPD_ON_OFF

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Engine coolant fan low speed HB20S_ENG_CLT_FAN_LOW_SPD

  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Engine RPM HB20S_ENGINE_RPMConfirmed

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x160C = 5644 → 56444 = 1,411 rpm

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Engine RPM HB20S_RPM_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Output speed HB20S_OUTPUT_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Output speed HB20S_OUTPUT_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Relative accelerator pedal position HB20S_REL_APP

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Relative accelerator pedal position HB20S_RELATIVE_ACCELERATOR_PEDAL_POSITION

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×0.390625
Range
0 to 99.6 %
Unit
%

In testing for 2013 to 2026.

Turbine speed HB20S_TURBINE_SPD

  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Turbine speed HB20S_TURBINE_SPEED_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2013 to 2026.

Vehicle speed HB20S_VEHICLE_SPEEDConfirmed

Pelican can show this parameter as the speed.

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Vehicle speed HB20S_VSS_7E1

Pelican can show this parameter as the speed.

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2013 to 2026.

Vehicle speed, v2 HB20S_VSS_V2

Pelican can show this parameter as the speed.

  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×1.25
Range
0 to 318.75 km/h
Unit
km/h

In testing for 2013 to 2026.

Transmission

Commanded gear HB20S_COMMANDED_GEARConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Commanded gear HB20S_COMMANDED_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Current gear HB20S_CURRENT_GEARConfirmed

  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2013 to 2016, 2018 to 2026

Example reply from a 2017 Hyundai HB20S.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2017. In testing for 2013 to 2016, 2018 to 2026.

Current gear HB20S_CURRENT_GEAR_7E1

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Current gear HB20S_CURRENT_GEAR_7E1_2

  • Service 21PID A1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Dual-clutch transmission absolute pedal position d HB20S_DUAL_CLU_TRANS_ABS_D

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Dual-clutch transmission clutch 1 slip HB20S_DUAL_CLU_TRANS_CLU_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2013 to 2026.

Dual-clutch transmission clutch 1 temperature HB20S_DUAL_CLU_TRANS_CLU_1_T

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 °C
Unit
°C

In testing for 2013 to 2026.

Dual-clutch transmission clutch 2 slip HB20S_DUAL_CLU_TRANS_CLU_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val4−512
Range
-512 to 15871 rpm
Unit
rpm

In testing for 2013 to 2026.

Dual-clutch transmission even shaft, gear engaged HB20S_DUAL_CLU_TRANS_EVEN

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Dual-clutch transmission gear ratio HB20S_DUAL_CLU_TRANS_GEAR

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53
Unit
Number

In testing for 2013 to 2026.

Dual-clutch transmission input shaft 1 HB20S_DUAL_CLU_TRANS_INPUT_1

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2013 to 2026.

Dual-clutch transmission input shaft 2 HB20S_DUAL_CLU_TRANS_INPUT_2

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val2−16384
Range
-16384 to 16383 rpm
Unit
rpm

In testing for 2013 to 2026.

Dual-clutch transmission odd shaft, gear engaged HB20S_DUAL_CLU_TRANS_ODD

  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Dual-clutch transmission throttle position HB20S_DUAL_CLU_TRANS

  • Service 21PID A4
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2013 to 2026.

Gear HB20S_GEAR_7E0

  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Gear selector HB20S_GEAR

  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2013 to 2026.

Trips

Diesel particulate filter odometer at last regeneration HB20S_DPF_ODO_LAST_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 328 to 359 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Distance since last DPF regeneration HB20S_DIST_SINCE_DPF_REGEN

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 360 to 391 of the reply, 32 bits.

Formula
val1000
Range
0 to 50000 km
Unit
km

In testing for 2013 to 2026.

Distance since last DPF regeneration HB20S_DISTANCE_SINCE_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 424 to 455 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Distance since last gasoline particulate filter regeneration HB20S_DIST_SINCE_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 360 to 391 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Odometer HB20S_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 456 to 487 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Odometer HB20S_ODO_7E0

  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Odometer at last DPF regeneration HB20S_ODO_LAST_DPF_REGEN

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 392 to 423 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Odometer at last gasoline particulate filter regeneration HB20S_ODO_LAST_GPF_REGEN

  • Service 22DID E009
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 328 to 359 of the reply, 32 bits. The bytes are in little-endian order.

Formula
val1000
Range
0 to 4294967 km
Unit
km

In testing for 2013 to 2026.

Vehicle total distance HB20S_VEH_TOT_DIST

  • Service 21PID B3
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 248 to 287 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775 km
Unit
km

In testing for 2013 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.