Parameters
The Honda ZR-V has 228 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery coolant temperature ZRV_BATTERY_COOLANT_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Battery module power ZRV_BATTERY_MODULE_POWERConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -524.288 to 524.272 kW
- Unit
- kW
0x0000 = 0 → = 0 kW
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2020, 2022 to 2023.
Distance traveled since last charge ZRV_BAT_DIST
- Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing
Bits 80 to 111 of the reply, 32 bits.
- Formula
- Range
- 0 to 250000 km
- Unit
- km
In testing for 2020, 2024 to 2026. Not supported for 2022 to 2023.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 13 to 14 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
3 | Not PSA |
Confirmed for 2025.
HV battery cell max state of charge ZRV_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
0x1003 = 4099 → = 40.99 %
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
HV battery current ZRV_HV_BATTERY_CURRENTConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
0x005F = 95 → = 0.95 A
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
HV battery fan 3 speed ZRV_HV_BATTERY_FAN_3_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2020, 2022 to 2026.
HV battery max cell voltage ZRV_HV_BATTERY_MAX_CELL_VOLTAGE
- Service 22
DID 2222 - Module
DBEF - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2020, 2022 to 2026.
HV battery usable capacity ZRV_HV_BATTERY_USABLE_CAPACITYConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → 0 %
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2025.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2025.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2025.
Motor assist battery temperature ZRV_IMA_BAT_T
- Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °C
- Unit
- °C
In testing for 2020, 2022 to 2026.
Motor assist battery temperature ZRV_IMA_BAT_T_DA10Confirmed
- Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °C
- Unit
- °C
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
State of charge ZRV_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x23 = 35 → 35 %
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
State of charge, raw count ZRV_ST_CHG_RAW_CNT
- Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
State of charge, raw count ZRV_ST_CHG_RAW_CNT_DA10Confirmed
- Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025.
Climate
A/C pressure ZRV_AC_PConfirmed
- Service 22
DID 2613 - Module
DA0E → 0E - Every
1 s - Testing for 2023 to 2026
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 4000 kPa
- Unit
- kPa
Confirmed for 2022. In testing for 2024 to 2026. Not supported for 2023.
Outside air temperature ZRV_AATConfirmed
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing for 2024 to 2026
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
Confirmed for 2022 to 2023. In testing for 2025 to 2026. Not supported for 2020, 2024.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Time since engine start ZRV_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2023 to 2024. In testing for 2022, 2025 to 2026. Not supported for 2020.
Time since engine start ZRV_RUNTM_PCM
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2020, 2022 to 2026.
Time since engine start ZRV_RUNTM_V2
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA11 → 11 - Every
5 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2020, 2022 to 2023.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2020, 2022 to 2023.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020, 2022 to 2025.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
ECU
Knock control ZRV_KNOCK_CTRL_PCMConfirmed
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Misfire count, cylinder 1 ZRV_MIS_1_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count, cylinder 2 ZRV_MIS_2_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count, cylinder 3 ZRV_MIS_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count, cylinder 4 ZRV_MIS_4_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Oil pressure ZRV_EOP
- Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2026. Not supported for 2020, 2022 to 2025.
Variable valve control ZRV_VTEC_CTRLConfirmed
- Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 2020, 2022, 2025 to 2026
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2020, 2025 to 2026. Not supported for 2022.
Electrical
Brake pressure ZRV_BRK_PConfirmed
- Service 22
DID 4005 - Module
DA28 → 28 - Every
1 s - Testing for 2020, 2022, 2024 to 2026
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Brake switch ZRV_BRK_SWConfirmed
- Service 22
DID 4004 - Module
DA28 → 28 - Every
1 s - Testing for 2020, 2022, 2024 to 2026
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Engine
A/C clutch ZRV_AC_CLU_PCMConfirmed
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2020. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
A/C clutch ZRV_AC_CLUTCHConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Active cylinders ZRV_ACTIVE_CYL
- Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2026. Not supported for 2020, 2022 to 2025.
Active cylinders ZRV_ACTIVE_CYL_PCM
- Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2020, 2022 to 2026.
Air conditioner clutch ZRV_AC_CLU
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2020, 2022 to 2026.
Air conditioning pressure, raw count ZRV_AC_P_RAW_CNT
- Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Air/gas ratio ZRV_AIRGAS_RAT_PCMConfirmed
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing for 2023, 2025 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2020, 2024. In testing for 2023, 2025 to 2026.
Air/gas ratio ZRV_AIRGAS_RATIOConfirmed
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 2020, 2022, 2025 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Air/gas ratio ZRV_AIRGAS_RATIO_V2
- Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.
Cabin air temperature ZRV_CABIN_AIR_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
0x13 = 19 → = 66.2 °F
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.
Catalyst temperature ZRV_CAT_T
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2026. Not supported for 2020, 2022 to 2025.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.
DC-DC converter temperature ZRV_DC_DC_CONVERTER_TEMPERATUREConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0000 = 0 → = 0 °C
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Electric load detector current ZRV_ELD_ELEC_LOAD_DUTY
- Service 22
DID 2661 - Module
DA11 → 11 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 A
- Unit
- A
In testing for 2020, 2022 to 2026.
Electric motor load ZRV_ELEC_MOTOR_LOAD
- Service 22
DID 2668 - Module
DA11 → 11 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- -100 to 100 %
- Unit
- %
In testing for 2020, 2022 to 2026.
Electric motor load ZRV_ELEC_MOTOR_LOAD_DA10Confirmed
- Service 22
DID 2668 - Module
DA10 → 10 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- -100 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Engine oil temperature, variant 1 ZRV_EOT_VAR_1
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2023, 2026. Not supported for 2020, 2024 to 2025.
Engine oil temperature, variant 2 ZRV_EOT_VAR_2
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2023, 2026. Not supported for 2020, 2024 to 2025.
Engine oil temperature, variant 3 ZRV_EOT_VAR_3
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Engine oil temperature, variant 3 ZRV_EOT_VAR_3_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2022 to 2026.
Engine oil temperature, variant 4 ZRV_EOT_VAR_4
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Engine oil temperature, variant 4 ZRV_EOT_VAR_4_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020, 2022 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Evaporative purge control load ZRV_EVAP_PC_LOAD
- Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.61 %
- Unit
- %
In testing for 2020, 2022 to 2026.
Fuel/air commanded equivalence ratio ZRV_FUELAIR_CARConfirmed
- Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing for 2020, 2022, 2025 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Fuel/air commanded equivalence ratio ZRV_FUELAIR_CAR_PCM
- Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2020, 2022 to 2026.
Generator ZRV_GEN
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2020, 2022 to 2026.
Generator ZRV_GENERATORConfirmed
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Generator ZRV_GENERATOR_PCMConfirmed
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Knock control ZRV_KNOCK_CONTROLConfirmed
ECU's determination of fuel quality.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 2020, 2022, 2025 to 2026
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Raw value
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Knock control ZRV_KNOCK_CONTROL_V2
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2026. Not supported for 2020, 2022 to 2025.
Maintenance, air cleaner ZRV_MAINT_AIR_CLNConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, cabin filter ZRV_MAINT_CABIN_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, engine coolant ZRV_MAINT_COOLConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, general inspection ZRV_MAINT_INSPConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, oil & filter ZRV_MAINT_OIL_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, rake fluid ZRV_MAINT_BRK_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, spark plugs & valves ZRV_MAINT_SPARKConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Maintenance, transmission fluid ZRV_MAINT_TRANS_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Misfire count #1 ZRV_MIS_1Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Misfire count #1, variant 1 ZRV_MIS_CNT_1_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #1, variant 1 ZRV_MISFIRE_COUNT_1_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #1, variant 2 ZRV_MISFIRE_COUNT_1_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #1, variant 3 ZRV_MIS_CNT_1_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #1, variant 3 ZRV_MISFIRE_COUNT_1_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #2 ZRV_MIS_2Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Misfire count #2, variant 1 ZRV_MIS_CNT_2_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #2, variant 1 ZRV_MISFIRE_COUNT_2_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #2, variant 2 ZRV_MISFIRE_COUNT_2_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #2, variant 3 ZRV_MIS_CNT_2_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #2, variant 3 ZRV_MISFIRE_COUNT_2_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #3 ZRV_MIS_3Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Misfire count #3, variant 1 ZRV_MIS_CNT_3_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #3, variant 1 ZRV_MISFIRE_COUNT_3_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #3, variant 2 ZRV_MISFIRE_COUNT_3_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #3, variant 3 ZRV_MIS_CNT_3_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #3, variant 3 ZRV_MISFIRE_COUNT_3_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #4 ZRV_MIS_4Confirmed
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2020, 2022, 2025 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Misfire count #4, variant 1 ZRV_MIS_CNT_4_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #4, variant 1 ZRV_MISFIRE_COUNT_4_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #4, variant 2 ZRV_MISFIRE_COUNT_4_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count #4, variant 3 ZRV_MIS_CNT_4_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2022 to 2026.
Misfire count #4, variant 3 ZRV_MISFIRE_COUNT_4_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing for 2022 to 2026
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Supported for 2020. Not supported for 2024.
Misfire count 1 ZRV_MIS_CNT_1
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Misfire count 2 ZRV_MIS_CNT_2
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Misfire count 3 ZRV_MIS_CNT_3
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Misfire count 4 ZRV_MIS_CNT_4
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Motor inverter, current ZRV_MOTOR_INVERTER_CURRENTConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Outside air temperature ZRV_OUTSIDE_AIR_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
0x00 = 0 → = 32 °F
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.
Variable timing control duty ZRV_VTC_DUTYConfirmed
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 2020, 2022, 2025 to 2026
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Variable valve timing duty ZRV_VTC_DUTY_PCMConfirmed
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing for 2022 to 2026
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2022 to 2023, 2025 to 2026. Not supported for 2024.
VTEC valve control ZRV_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.
Internal
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2022 to 2023. Supported for 2020, 2024 to 2025.
Fuel
Air-fuel mixture heater ZRV_AIR_FUEL_MIXTUREConfirmed
- Service 22
DID 266D - Module
DA0E → 0E - Every
1 s - Testing for 2023, 2025 to 2026
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
Confirmed for 2020, 2024. In testing for 2023, 2025 to 2026.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2024. Supported for 2023.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024. Supported for 2023.
Fuel level ZRV_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 2026
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2020, 2022 to 2025. In testing for 2026.
Fuel pressure sensor a, raw count ZRV_SENS_FUEL_P_RAW_CNT
- Service 22
DID 2615 - Module
DA11 → 11 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2020, 2022 to 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2024. Supported for 2020, 2022 to 2023, 2025.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2020, 2022.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2020, 2022 to 2023.
Fuel/air commanded equivalence ratio ZRV_FUEL_AIR_RATIOConfirmed
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing for 2020, 2022, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2023 to 2024. In testing for 2026. Not supported for 2020, 2022, 2025.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2024. Supported for 2023.
Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2020, 2022.
Movement
Generator motor speed ZRV_GENERATOR_MOTOR_SPEEDConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Example reply from a 2023 Honda ZR-V.
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 16320 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2023. In testing for 2020, 2022, 2024 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2020, 2022 to 2025.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2023 to 2024. Supported for 2020, 2022, 2025.
Tires
Maintenance, tire rotation ZRV_MAINT_TIREConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2023. In testing for 2020, 2024 to 2026. Not supported for 2022.
Transmission
Automatic transmission fluid temperature ZRV_ATF_T
- Service 22
DID 2201 - Module
DA1D → 1D - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2026. Not supported for 2020, 2022 to 2025.
Current gear ZRV_GEAR_1D
- Service 22
DID 2221 - Module
DA1D → 1D - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2022 to 2023, 2025 to 2026. Not supported for 2020, 2024.
Current gear var.2 ZRV_CURRENT_GEAR_VAR_2Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
1 s - Testing for 2023, 2025 to 2026
Bits 352 to 359 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020, 2024. In testing for 2023, 2025 to 2026.
Current gear var.3 ZRV_CURRENT_GEAR_VAR_3Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
1 s - Testing for 2023, 2025 to 2026
Bits 368 to 375 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020, 2024. In testing for 2023, 2025 to 2026.
Trips
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2024. Supported for 2023.
Odometer ZRV_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2023 to 2024. In testing for 2022, 2025 to 2026. Not supported for 2020.
Odometer ZRV_ODO_PCM
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2020, 2022 to 2026.
Odometer ZRV_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing for 2020, 2022 to 2023, 2025 to 2026
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2026. Supported for 2024. Not supported for 2020, 2022 to 2023, 2025.
Odometer, variation 3 ZRV_ODO_V3Confirmed
- Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing for 2024 to 2026
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
Confirmed for 2022 to 2023. In testing for 2024 to 2026.