Parameters
The Honda WRV has 374 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery voltage HONDA_12V_V
12 V system voltage from the Drive Motor Control Module (matches Chevrolet-Equinox-EV DA1D 2233E5). Note: LYRIQ command_support docs list this DID as HV pack voltage - on-vehicle it reads 13.1-13.9 V under DC-DC float and does not track pack voltage.
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 33E5 - Module
DA1D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
Battery coolant temperature HONDA_BATTERY_COOLANT_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery module power HONDA_BATTERY_MODULE_POWER
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -524.288 to 524.272 kW
- Unit
- kW
In testing for 2017 to 2026.
Cell voltage limit during charge HONDA_CEL_V_LIM
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, average HONDA_HVBAT_C_V_AVG
- Service 22
DID 2AF5 - Module
DACB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 V
- Unit
- V
In testing for 2017 to 2026.
Cell voltage, maximum HONDA_HVBAT_C_V_MAX
- Service 22
DID 2AF5 - Module
DACB - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 V
- Unit
- V
In testing for 2017 to 2026.
Cell voltage, minimum HONDA_HVBAT_C_V_MIN
- Service 22
DID 2AF5 - Module
DACB - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 V
- Unit
- V
In testing for 2017 to 2026.
Charge station pilot current HONDA_EVSE_PILOT_C
J1772 pilot-advertised AC current limit. Read 38.8 A on a 9.2 kW EVSE while plugged; snaps to a 10.0 A default when unplugged.
- Service 22
DID 4149 - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 A
- Unit
- A
In testing for 2017 to 2026.
Charging voltage target HONDA_CHG_V_TGT
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Distance traveled since last charge HONDA_BAT_DIST
- Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing
Bits 80 to 111 of the reply, 32 bits.
- Formula
- Range
- 0 to 250000 km
- Unit
- km
In testing for 2017 to 2026.
High voltage battery cells, max state of charge HONDA_CELL_MAX_SOC
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
High voltage battery cells, max state of charge HONDA_CELL_MIN_SOC
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
High voltage battery module 1A temperature HONDA_HVB_MOD_1A_T
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery module 1B temperature HONDA_HVB_MOD_1B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery module 2A temperature HONDA_HVB_MOD_2A_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 488 to 503 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery module 3A temperature HONDA_HVB_MOD_3A_T
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery module 3B temperature HONDA_HVB_MOD_3B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery module 4B temperature HONDA_HVB_MOD_4B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 520 to 535 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
High voltage battery total capacity HONDA_HVB_CAP
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2017 to 2026.
High voltage battery total current HONDA_HVB_C_TOTAL
Pelican can show this parameter as the traction battery current.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 200 A
- Unit
- A
In testing for 2017 to 2026.
High voltage battery voltage HONDA_HVB_V
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery voltage, line B HONDA_HVB_V_B
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
In testing for 2017 to 2026.
HV battery cell max state of charge HONDA_HV_BATTERY_CELL_MAX_STATE_OF_CHARGE
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2017 to 2026.
HV battery current HONDA_HV_BATTERY_CURRENT
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
HV battery fan 3 speed HONDA_HV_BATTERY_FAN_3_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2017 to 2026.
HV battery max cell voltage HONDA_HV_BATTERY_MAX_CELL_VOLTAGE
- Service 22
DID 2222 - Module
DBEF - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2017 to 2026.
HV battery usable capacity HONDA_HV_BATTERY_USABLE_CAPACITY
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Motor assist battery temperature HONDA_IMA_BAT_T
- Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °C
- Unit
- °C
In testing for 2017 to 2026.
Motor assist battery temperature HONDA_IMA_BAT_T_DA10
- Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- -40 to 419 °C
- Unit
- °C
In testing for 2017 to 2026.
Normal charger input voltage HONDA_CHG_V_IN
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2017 to 2026.
Normal charger output voltage HONDA_CHG_V_OUT
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2017 to 2026.
State of charge HONDA_SOC
Pelican can show this parameter as the state of charge.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge HONDA_SOC_V2
Pelican can show this parameter as the state of charge.
- Service 22
DID 2B43 - Module
DACB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge HONDA_STATE_OF_CHARGE
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge, high resolution HONDA_SOC_HD
A high resolution measure of the battery pack's remaining state of charge.
Pelican can show this parameter as the state of charge.
- Service 22
DID 27C6 - Module
DACB - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge, raw count HONDA_ST_CHG_RAW_CNT
- Service 22
DID 2614 - Module
DA11 → 11 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
State of charge, raw count HONDA_ST_CHG_RAW_CNT_DA10
- Service 22
DID 2614 - Module
DA10 → 10 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Traction battery coolant temperature 1 HONDA_HVBAT_COOL_T1
- Service 22
DID 40E5 - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 °C
- Unit
- °C
In testing for 2017 to 2026.
Traction battery coolant temperature 2 HONDA_HVBAT_COOL_T2
- Service 22
DID 40E6 - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 °C
- Unit
- °C
In testing for 2017 to 2026.
Traction battery current HONDA_HVBAT_C
Signed pack current from the drive-motor/power-electronics controller (negative = charging). Confirmed -22.75 A at a steady 9.22 kW AC charge and +0.9 A accessory draw in Ready. Same register family as Chevy Bolt 7E1 222414.
Pelican can show this parameter as the traction battery current.
- Service 22
DID 2414 - Module
DA17 → 17 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1000 to 1000 A
- Unit
- A
In testing for 2017 to 2026.
Traction battery group 1 voltage HONDA_HVBAT_GRP1_V
- Service 22
DID 416C - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 2017 to 2026.
Traction battery group 2 voltage HONDA_HVBAT_GRP2_V
- Service 22
DID 416D - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 2017 to 2026.
Traction battery group 3 voltage HONDA_HVBAT_GRP3_V
~51 V battery groups; rise under charge, fall under load, and read 0 with the vehicle off (live measurements behind the contactors).
- Service 22
DID 416E - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 2017 to 2026.
Traction battery nominal voltage HONDA_HVBAT_NOM_V
Constant rated (nominal) pack voltage, 352.1 V on a 2025 LYRIQ - identical while charging at 70% SOC and at rest at 80% SOC, so it is not a live measurement. Duplicates at 2428/242D/2434/2489.
- Service 22
DID 2429 - Module
DA17 → 17 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023 V
- Unit
- V
In testing for 2017 to 2026.
Traction battery temperature HONDA_HVBAT_T
Same encoding as Chevy Bolt 7E4 22434F.
- Service 22
DID 434F - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Traction battery temperature sensor A HONDA_HVBAT_T_A
- Service 22
DID 4127 - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 °C
- Unit
- °C
In testing for 2017 to 2026.
Traction battery temperature sensor B HONDA_HVBAT_T_B
- Service 22
DID 4124 - Module
DA40 → 40 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047 °C
- Unit
- °C
In testing for 2017 to 2026.
Cells
Battery capacity, line B HONDA_HVB_CAP_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2017 to 2026.
Cell voltage, 1 HONDA_CEL_V_B1
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 2 HONDA_CEL_V_B2
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 3 HONDA_CEL_V_B3
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 4 HONDA_CEL_V_B4
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 5 HONDA_CEL_V_B5
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 6 HONDA_CEL_V_B6
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 7 HONDA_CEL_V_B7
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 8 HONDA_CEL_V_B8
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 9 HONDA_CEL_V_B9
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 10 HONDA_CEL_V_B10
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 11 HONDA_CEL_V_B11
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 12 HONDA_CEL_V_B12
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 13 HONDA_CEL_V_B13
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 14 HONDA_CEL_V_B14
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 15 HONDA_CEL_V_B15
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 16 HONDA_CEL_V_B16
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 17 HONDA_CEL_V_B17
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 18 HONDA_CEL_V_B18
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 19 HONDA_CEL_V_B19
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 20 HONDA_CEL_V_B20
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 21 HONDA_CEL_V_B21
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 22 HONDA_CEL_V_B22
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 23 HONDA_CEL_V_B23
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 24 HONDA_CEL_V_B24
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 25 HONDA_CEL_V_B25
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 26 HONDA_CEL_V_B26
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 27 HONDA_CEL_V_B27
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 28 HONDA_CEL_V_B28
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 29 HONDA_CEL_V_B29
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 30 HONDA_CEL_V_B30
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 31 HONDA_CEL_V_B31
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 32 HONDA_CEL_V_B32
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 33 HONDA_CEL_V_B33
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 34 HONDA_CEL_V_B34
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 35 HONDA_CEL_V_B35
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 36 HONDA_CEL_V_B36
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 37 HONDA_CEL_V_B37
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 38 HONDA_CEL_V_B38
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 39 HONDA_CEL_V_B39
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 40 HONDA_CEL_V_B40
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 41 HONDA_CEL_V_B41
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 42 HONDA_CEL_V_B42
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 43 HONDA_CEL_V_B43
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 44 HONDA_CEL_V_B44
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 45 HONDA_CEL_V_B45
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 46 HONDA_CEL_V_B46
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 47 HONDA_CEL_V_B47
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 48 HONDA_CEL_V_B48
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 49 HONDA_CEL_V_B49
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 50 HONDA_CEL_V_B50
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 51 HONDA_CEL_V_B51
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 52 HONDA_CEL_V_B52
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 53 HONDA_CEL_V_B53
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 54 HONDA_CEL_V_B54
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 55 HONDA_CEL_V_B55
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 56 HONDA_CEL_V_B56
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 57 HONDA_CEL_V_B57
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 58 HONDA_CEL_V_B58
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 59 HONDA_CEL_V_B59
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 60 HONDA_CEL_V_B60
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 61 HONDA_CEL_V_B61
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 62 HONDA_CEL_V_B62
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 63 HONDA_CEL_V_B63
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 64 HONDA_CEL_V_B64
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 65 HONDA_CEL_V_B65
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 66 HONDA_CEL_V_B66
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 67 HONDA_CEL_V_B67
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 68 HONDA_CEL_V_B68
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 69 HONDA_CEL_V_B69
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 70 HONDA_CEL_V_B70
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 71 HONDA_CEL_V_B71
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 72 HONDA_CEL_V_B72
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 73 HONDA_CEL_V_B73
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 74 HONDA_CEL_V_B74
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 75 HONDA_CEL_V_B75
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 76 HONDA_CEL_V_B76
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 77 HONDA_CEL_V_B77
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 78 HONDA_CEL_V_B78
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 79 HONDA_CEL_V_B79
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 80 HONDA_CEL_V_B80
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 81 HONDA_CEL_V_B81
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 82 HONDA_CEL_V_B82
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 83 HONDA_CEL_V_B83
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Cell voltage, 84 HONDA_CEL_V_B84
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell max SOC, line B HONDA_CEL_MAX_SOC_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Individual cell min SOC, line B HONDA_CEL_MIN_SOC_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Individual cell voltage A1 HONDA_CEL_V_A1
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A2 HONDA_CEL_V_A2
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A3 HONDA_CEL_V_A3
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A4 HONDA_CEL_V_A4
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A5 HONDA_CEL_V_A5
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A6 HONDA_CEL_V_A6
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A7 HONDA_CEL_V_A7
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A8 HONDA_CEL_V_A8
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A9 HONDA_CEL_V_A9
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A10 HONDA_CEL_V_A10
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A11 HONDA_CEL_V_A11
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A12 HONDA_CEL_V_A12
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A13 HONDA_CEL_V_A13
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A14 HONDA_CEL_V_A14
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A15 HONDA_CEL_V_A15
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A16 HONDA_CEL_V_A16
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A17 HONDA_CEL_V_A17
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A18 HONDA_CEL_V_A18
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A19 HONDA_CEL_V_A19
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A20 HONDA_CEL_V_A20
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A21 HONDA_CEL_V_A21
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A22 HONDA_CEL_V_A22
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A23 HONDA_CEL_V_A23
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A24 HONDA_CEL_V_A24
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A25 HONDA_CEL_V_A25
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A26 HONDA_CEL_V_A26
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A27 HONDA_CEL_V_A27
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A28 HONDA_CEL_V_A28
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A29 HONDA_CEL_V_A29
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A30 HONDA_CEL_V_A30
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A31 HONDA_CEL_V_A31
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A32 HONDA_CEL_V_A32
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A33 HONDA_CEL_V_A33
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A34 HONDA_CEL_V_A34
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A35 HONDA_CEL_V_A35
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A36 HONDA_CEL_V_A36
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A37 HONDA_CEL_V_A37
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A38 HONDA_CEL_V_A38
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A39 HONDA_CEL_V_A39
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A40 HONDA_CEL_V_A40
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A41 HONDA_CEL_V_A41
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A42 HONDA_CEL_V_A42
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A43 HONDA_CEL_V_A43
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A44 HONDA_CEL_V_A44
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A45 HONDA_CEL_V_A45
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A46 HONDA_CEL_V_A46
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A47 HONDA_CEL_V_A47
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A48 HONDA_CEL_V_A48
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A49 HONDA_CEL_V_A49
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A50 HONDA_CEL_V_A50
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A51 HONDA_CEL_V_A51
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A52 HONDA_CEL_V_A52
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A53 HONDA_CEL_V_A53
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A54 HONDA_CEL_V_A54
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A55 HONDA_CEL_V_A55
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A56 HONDA_CEL_V_A56
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A57 HONDA_CEL_V_A57
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A58 HONDA_CEL_V_A58
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A59 HONDA_CEL_V_A59
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A60 HONDA_CEL_V_A60
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A61 HONDA_CEL_V_A61
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A62 HONDA_CEL_V_A62
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A63 HONDA_CEL_V_A63
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A64 HONDA_CEL_V_A64
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A65 HONDA_CEL_V_A65
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A66 HONDA_CEL_V_A66
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A67 HONDA_CEL_V_A67
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A68 HONDA_CEL_V_A68
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A69 HONDA_CEL_V_A69
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A70 HONDA_CEL_V_A70
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A71 HONDA_CEL_V_A71
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A72 HONDA_CEL_V_A72
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A73 HONDA_CEL_V_A73
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A74 HONDA_CEL_V_A74
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A75 HONDA_CEL_V_A75
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A76 HONDA_CEL_V_A76
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A77 HONDA_CEL_V_A77
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A78 HONDA_CEL_V_A78
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A79 HONDA_CEL_V_A79
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A80 HONDA_CEL_V_A80
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A81 HONDA_CEL_V_A81
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A82 HONDA_CEL_V_A82
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A83 HONDA_CEL_V_A83
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Individual cell voltage A84 HONDA_CEL_V_A84
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2017 to 2026.
Climate
A/C pressure HONDA_AC_P
- Service 22
DID 2613 - Module
DA0E → 0E - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 4000 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Outside air temperature HONDA_AAT
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
In testing for 2017 to 2026.
Outside air temperature HONDA_AAT_C
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °C
- Unit
- °C
In testing for 2017 to 2026.
Clocks
Time since engine start HONDA_RUNTM
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2026.
Time since engine start HONDA_RUNTM_PCM
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2026.
Time since engine start HONDA_RUNTM_V2
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA11 → 11 - Every
5 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2017 to 2026.
Control
Steering wheel angle HONDA_STEER_ANGLE
- Service 22
DID 4C2D - Module
DA28 - Every
100 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.896 to 720.8739 °
- Unit
- °
In testing for 2017 to 2026.
ECU
Knock control HONDA_KNOCK_CTRL
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2017 to 2026.
Knock control HONDA_KNOCK_CTRL_PCM
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 1 HONDA_MIS_1_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 2 HONDA_MIS_2_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 3 HONDA_MIS_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 4 HONDA_MIS_4_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 5 HONDA_MIS_5_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 5 HONDA_MISFIRE_5
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 6 HONDA_MIS_6_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count, cylinder 6 HONDA_MISFIRE_6
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Oil pressure HONDA_EOP
- Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Variable valve control HONDA_VTEC_CTRL
- Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Electrical
Brake fluid pressure HONDA_BRK_FLD_P
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Raw value
In testing for 2017 to 2026.
Brake pedal stroke HONDA_BRK_PED_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 mm
- Unit
- mm
In testing for 2017 to 2026.
Brake pressure HONDA_BRK_P
- Service 22
DID 4005 - Module
DA28 → 28 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
In testing for 2017 to 2026.
Brake switch HONDA_BRK_SW
- Service 22
DID 4004 - Module
DA28 → 28 - Every
250 ms - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Master cylinder stroke HONDA_MSTR_CYL_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
In testing for 2017 to 2026.
Slave cylinder stroke HONDA_SLV_CYL_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 mm
- Unit
- mm
In testing for 2017 to 2026.
Engine
A/C clutch HONDA_AC_CLU_PCM
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
A/C clutch HONDA_AC_CLUTCH
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Active cylinders HONDA_ACTIVE_CYL
- Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2017 to 2026.
Active cylinders HONDA_ACTIVE_CYL_PCM
- Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2017 to 2026.
Air conditioner clutch HONDA_AC_CLU_DA11
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Air conditioning pressure, raw count HONDA_AC_P_RAW_CNT
- Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Air/gas ratio HONDA_AIRGAS_RAT_PCM
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO_PCM
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO_V2
- Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Ambient air temperature, cabin HONDA_AAT_CAB
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Ambient air temperature, outside HONDA_AAT_OUT
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Brake pressure HONDA_BP
- Service 22
DID 4A7C - Module
DA28 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -13800 to 11700 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Cabin air temperature HONDA_CABIN_AIR_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2017 to 2026.
Catalyst temperature HONDA_CAT_T
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2017 to 2026.
DC-DC converter temperature HONDA_DC_DC_CONVERTER_TEMPERATURE
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2017 to 2026.
Electric load detector current HONDA_ELD_ELEC_LOAD_DUTY
- Service 22
DID 2661 - Module
DA11 → 11 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 A
- Unit
- A
In testing for 2017 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD
- Service 22
DID 2668 - Module
DA11 → 11 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- -100 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD_DA10
- Service 22
DID 2668 - Module
DA10 → 10 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
- Range
- -100 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Engine coolant temperature sensor 1 HONDA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine coolant temperature sensor 2 HONDA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine coolant temperature sensor 3 HONDA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine coolant temperature sensor 4 HONDA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil level HONDA_OIL_LEVEL
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 mm
- Unit
- mm
In testing for 2017 to 2026.
Engine oil temperature, variant 1 HONDA_EOT_VAR_1
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, variant 2 HONDA_EOT_VAR_2
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Evaporative purge control load HONDA_EVAP_PC_LOAD
- Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 99.61 %
- Unit
- %
In testing for 2017 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR
- Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR_PCM
- Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2017 to 2026.
Generator HONDA_GEN
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator HONDA_GENERATOR
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator HONDA_GENERATOR_DA11
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Generator HONDA_GENERATOR_PCM
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Knock control HONDA_KNOCK_CONTROL
ECU's determination of fuel quality.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Raw value
In testing for 2017 to 2026.
Knock control HONDA_KNOCK_CONTROL_V2
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2017 to 2026.
Maintenance, air cleaner HONDA_MAINT_AIR_CLN
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, cabin filter HONDA_MAINT_CABIN_FLT
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, engine coolant HONDA_MAINT_COOL
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, general inspection HONDA_MAINT_INSP
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, oil & filter HONDA_MAINT_OIL_FLT
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, rake fluid HONDA_MAINT_BRK_FLD
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, spark plugs & valves HONDA_MAINT_SPARK
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Maintenance, transmission fluid HONDA_MAINT_TRANS_FLD
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Misfire count #1 HONDA_MIS_1
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #1, variant 1 HONDA_MIS_CNT_1_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #1, variant 1 HONDA_MISFIRE_COUNT_1_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #1, variant 2 HONDA_MISFIRE_COUNT_1_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #1, variant 3 HONDA_MIS_CNT_1_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #1, variant 3 HONDA_MISFIRE_COUNT_1_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2 HONDA_MIS_2
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2, variant 1 HONDA_MIS_CNT_2_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2, variant 1 HONDA_MISFIRE_COUNT_2_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2, variant 2 HONDA_MISFIRE_COUNT_2_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2, variant 3 HONDA_MIS_CNT_2_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #2, variant 3 HONDA_MISFIRE_COUNT_2_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3 HONDA_MIS_3
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3, variant 1 HONDA_MIS_CNT_3_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3, variant 1 HONDA_MISFIRE_COUNT_3_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3, variant 2 HONDA_MISFIRE_COUNT_3_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3, variant 3 HONDA_MIS_CNT_3_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #3, variant 3 HONDA_MISFIRE_COUNT_3_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4 HONDA_MIS_4
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4, variant 1 HONDA_MIS_CNT_4_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4, variant 1 HONDA_MISFIRE_COUNT_4_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4, variant 2 HONDA_MISFIRE_COUNT_4_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4, variant 3 HONDA_MIS_CNT_4_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #4, variant 3 HONDA_MISFIRE_COUNT_4_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #5, variant 1 HONDA_MIS_CNT_5_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #5, variant 1 HONDA_MISFIRE_COUNT_5_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #5, variant 2 HONDA_MISFIRE_COUNT_5_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #5, variant 3 HONDA_MIS_CNT_5_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #5, variant 3 HONDA_MISFIRE_COUNT_5_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #6, variant 1 HONDA_MIS_CNT_6_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #6, variant 1 HONDA_MISFIRE_COUNT_6_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #6, variant 2 HONDA_MISFIRE_COUNT_6_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #6, variant 3 HONDA_MIS_CNT_6_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count #6, variant 3 HONDA_MISFIRE_COUNT_6_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count 1 HONDA_MIS_CNT_1
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count 2 HONDA_MIS_CNT_2
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count 3 HONDA_MIS_CNT_3
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Misfire count 4 HONDA_MIS_CNT_4
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Motor inverter, current HONDA_MOTOR_INVERTER_CURRENT
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2017 to 2026.
Outside air temperature HONDA_OUTSIDE_AIR_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2017 to 2026.
Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Variable timing control duty HONDA_VARIABLE_TIM_CTRL
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Variable timing control duty HONDA_VTC_DUTY
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Variable timing control duty HONDA_VTC_DUTY_DA11
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Variable valve timing duty HONDA_VTC_DUTY_PCM
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
VTEC valve control HONDA_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
VTEC valve control HONDA_VTEC_VALVE_CTRL_PCM
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2017 to 2026.
Fuel
Air-fuel mixture heater HONDA_AIR_FUEL_MIXTURE
- Service 22
DID 266D - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2017 to 2026.
Fuel level HONDA_FLV
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
In testing for 2017 to 2026.
Fuel pressure sensor A, raw count HONDA_SENS_FUEL_P_RAW_CNT
- Service 22
DID 2615 - Module
DA11 → 11 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2017 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUEL_AIR_RAT_PCM
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUEL_AIR_RATIO
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUEL_AIR_RATIO_PCM
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Movement
Generator motor speed HONDA_GENERATOR_MOTOR_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 16320 rpm
- Unit
- rpm
In testing for 2017 to 2026.
Orientation
Lateral acceleration HONDA_LAT_G
- Service 22
DID 4C2F - Module
DA28 - Every
100 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -52 to 52 g
- Unit
- g
In testing for 2017 to 2026.
Longitudinal acceleration HONDA_LNG_G
- Service 22
DID 4C30 - Module
DA28 - Every
100 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -52 to 52 g
- Unit
- g
In testing for 2017 to 2026.
Tires
Front left tire pressure HONDA_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front left tire pressure HONDA_TP_FL_V2
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 5005 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front left tire temperature HONDA_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 200 to 207 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Front left wheel speed HONDA_FL_WHEEL_VSS
- Service 22
DID 4A7A - Module
DA28 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Front right tire pressure HONDA_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front right tire pressure HONDA_TP_FR_V2
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 5006 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Front right tire temperature HONDA_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Front right wheel speed HONDA_FR_WHEEL_VSS
- Service 22
DID 4A7A - Module
DA28 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Maintenance, tire rotation HONDA_MAINT_TIRE
- Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2017 to 2026.
Rear left tire pressure HONDA_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear left tire pressure HONDA_TP_RL_V2
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 5008 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear left tire temperature HONDA_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear left wheel speed HONDA_RL_WHEEL_VSS
- Service 22
DID 4A7A - Module
DA28 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Rear right tire pressure HONDA_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear right tire pressure HONDA_TP_RR_V2
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 5007 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2017 to 2026.
Rear right tire temperature HONDA_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2017 to 2026.
Rear right wheel speed HONDA_RR_WHEEL_VSS
- Service 22
DID 4A7A - Module
DA28 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2017 to 2026.
Transmission
Automatic transmission fluid temperature HONDA_ATF_T
- Service 22
DID 2201 - Module
DA1D → 1D - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2017 to 2026.
Current gear var.2 HONDA_CURRENT_GEAR_VAR_2
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bits 352 to 359 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Current gear var.3 HONDA_CURRENT_GEAR_VAR_3
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Gear HONDA_GEAR
- Service 22
DID 2221 - Module
DA1D → 1D - Every
250 ms - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Transmission fluid temperature HONDA_ATF_T_DA1E
- Service 22
DID 3083 - Module
DA1E → 1E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission fluid temperature HONDA_ATF_T_V2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 3083 - Module
DA1E → 1E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2017 to 2026.
Transmission gear HONDA_GEAR_DA1E
- Service 22
DID 3086 - Module
DA1E → 1E - Every
250 ms - Testing
Bits 160 to 167 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | P | Park |
1 | D1 | Drive 1 |
2 | D2 | Drive 2 |
3 | D3 | Drive 3 |
4 | D4 | Drive 4 |
5 | D5 | Drive 5 |
6 | D6 | Drive 6 |
7 | D7 | Drive 7 |
8 | D8 | Drive 8 |
9 | D9 | Drive 9 |
14 | N | Neutral |
15 | R | Reverse |
In testing for 2017 to 2026.
Trips
Odometer HONDA_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Odometer HONDA_ODO_PCM
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Odometer HONDA_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2017 to 2026.
Odometer, variation 3 HONDA_ODO_V3
- Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
In testing for 2017 to 2026.