Honda S2000

Parameters

The Honda S2000 has 25 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Time since engine start S2000_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2006 to 2007. In testing for 1999 to 2005, 2008 to 2009.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Clocks

Time since engine start S2000_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2006 to 2007. In testing for 1999 to 2005, 2008 to 2009.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2006 to 2007.

ECU

Variable valve control S2000_VTEC_CTRLConfirmed

  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1999 to 2005, 2008 to 2009

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2005, 2008 to 2009.

Engine

A/C clutch S2000_AC_CLUTCHConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Air/gas ratio S2000_AIRGAS_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006 to 2007.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2006 to 2007.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2007. Supported for 2006.

Engine oil temperature, variant 3 S2000_EOT_VAR_3

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2009.

Engine oil temperature, variant 4 S2000_EOT_VAR_4

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2009.

Fuel/air commanded equivalence ratio S2000_FUELAIR_CARConfirmed

  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1999 to 2005, 2008 to 2009

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Generator S2000_GENERATORConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Knock control S2000_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1999 to 2005, 2008 to 2009

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Raw value

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Misfire count #1 S2000_MIS_1Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Misfire count #2 S2000_MIS_2Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Misfire count #3 S2000_MIS_3Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Misfire count #4 S2000_MIS_4Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2006 to 2007.

Variable timing control duty S2000_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 1999 to 2005, 2008 to 2009

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2006 to 2007. In testing for 1999 to 2004, 2008 to 2009. Not supported for 2005.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2006 to 2007.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2006 to 2007.

Fuel

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007. Supported for 2006.

Fuel/air commanded equivalence ratio S2000_FUEL_AIR_RATIO

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2004, 2008 to 2009. Supported for 2006 to 2007. Not supported for 2005.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2006 to 2007.

Trips

Odometer S2000_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 1999 to 2005, 2008 to 2009

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2006 to 2007. In testing for 1999 to 2005, 2008 to 2009.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.