Honda CR-V Hybrid

Parameters

The Honda CR-V Hybrid has 303 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery coolant temperature CRVH_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery coolant temperature CRVH_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Battery module power CRVH_BATTERY_MODULE_POWERConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val×0.016
Range
-524.288 to 524.272 kW
Unit
kW

0x0000 = 0 → 0×0.016 = 0 kW

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Cell voltage limit during charge CRVH_CEL_V_LIM

  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Charging voltage target CRVH_CHG_V_TGT

  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Distance traveled since last charge CRVH_BAT_DIST

  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

High voltage battery cells, max state of charge CRVH_CELL_MAX_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery cells, max state of charge CRVH_CELL_MIN_SOCConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery module 1A temperature CRVH_HVB_MOD_1A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery module 1B temperature CRVH_HVB_MOD_1B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

High voltage battery module 2A temperature CRVH_HVB_MOD_2A_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 488 to 503 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

High voltage battery module 3A temperature CRVH_HVB_MOD_3A_TConfirmed

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery module 3B temperature CRVH_HVB_MOD_3B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

High voltage battery module 4B temperature CRVH_HVB_MOD_4B_T

  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 520 to 535 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

High voltage battery total capacity CRVH_HVB_CAPConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery total current CRVH_HVB_C_TOTALConfirmed

Pelican can show this parameter as the traction battery current.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-100 to 200 A
Unit
A

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery voltage CRVH_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

High voltage battery voltage, line B CRVH_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

HV battery cell max state of charge CRVH_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 100 %
Unit
%

0x0E36 = 3638 → 3638100 = 36.38 %

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

HV battery current CRVH_HV_BATTERY_CURRENTConfirmed

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0091 = 145 → 145100 = 1.45 A

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

HV battery fan 3 speed CRVH_HV_BATTERY_FAN_3_SPEED

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 288 to 295 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2017 to 2022, 2024, 2026. Supported for 2023, 2025, 2027.

HV battery max cell voltage CRVH_HV_BATTERY_MAX_CELL_VOLTAGE

  • Service 22DID 2222
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 mV
Unit
mV

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

HV battery usable capacity CRVH_HV_BATTERY_USABLE_CAPACITYConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Normal charger input voltage CRVH_CHG_V_IN

  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val10
Range
0 to 500 V
Unit
V

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Normal charger output voltage CRVH_CHG_V_OUT

  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val10
Range
0 to 500 V
Unit
V

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

State of charge CRVH_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

State of charge CRVH_STATE_OF_CHARGEConfirmed

  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x1D = 29 → 29 %

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Cells

Battery capacity, line B CRVH_HVB_CAP_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 1 CRVH_CEL_V_B1

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 2 CRVH_CEL_V_B2

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 3 CRVH_CEL_V_B3

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 4 CRVH_CEL_V_B4

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 5 CRVH_CEL_V_B5

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 6 CRVH_CEL_V_B6

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 7 CRVH_CEL_V_B7

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 8 CRVH_CEL_V_B8

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 9 CRVH_CEL_V_B9

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 10 CRVH_CEL_V_B10

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 11 CRVH_CEL_V_B11

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 12 CRVH_CEL_V_B12

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 13 CRVH_CEL_V_B13

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 14 CRVH_CEL_V_B14

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 15 CRVH_CEL_V_B15

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 16 CRVH_CEL_V_B16

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 17 CRVH_CEL_V_B17

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 18 CRVH_CEL_V_B18

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 19 CRVH_CEL_V_B19

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 20 CRVH_CEL_V_B20

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 21 CRVH_CEL_V_B21

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 22 CRVH_CEL_V_B22

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 23 CRVH_CEL_V_B23

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 24 CRVH_CEL_V_B24

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 25 CRVH_CEL_V_B25

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 26 CRVH_CEL_V_B26

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 27 CRVH_CEL_V_B27

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 28 CRVH_CEL_V_B28

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 29 CRVH_CEL_V_B29

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 30 CRVH_CEL_V_B30

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 31 CRVH_CEL_V_B31

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 32 CRVH_CEL_V_B32

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 33 CRVH_CEL_V_B33

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 34 CRVH_CEL_V_B34

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 35 CRVH_CEL_V_B35

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 36 CRVH_CEL_V_B36

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 37 CRVH_CEL_V_B37

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 38 CRVH_CEL_V_B38

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 39 CRVH_CEL_V_B39

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 40 CRVH_CEL_V_B40

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 41 CRVH_CEL_V_B41

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 42 CRVH_CEL_V_B42

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 43 CRVH_CEL_V_B43

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 44 CRVH_CEL_V_B44

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 45 CRVH_CEL_V_B45

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 46 CRVH_CEL_V_B46

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 47 CRVH_CEL_V_B47

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 48 CRVH_CEL_V_B48

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 49 CRVH_CEL_V_B49

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 50 CRVH_CEL_V_B50

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 51 CRVH_CEL_V_B51

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 52 CRVH_CEL_V_B52

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 53 CRVH_CEL_V_B53

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 54 CRVH_CEL_V_B54

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 55 CRVH_CEL_V_B55

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 56 CRVH_CEL_V_B56

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 57 CRVH_CEL_V_B57

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 58 CRVH_CEL_V_B58

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 59 CRVH_CEL_V_B59

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 60 CRVH_CEL_V_B60

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 61 CRVH_CEL_V_B61

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 62 CRVH_CEL_V_B62

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 63 CRVH_CEL_V_B63

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 64 CRVH_CEL_V_B64

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 65 CRVH_CEL_V_B65

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 66 CRVH_CEL_V_B66

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 67 CRVH_CEL_V_B67

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 68 CRVH_CEL_V_B68

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 69 CRVH_CEL_V_B69

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 70 CRVH_CEL_V_B70

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 71 CRVH_CEL_V_B71

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 72 CRVH_CEL_V_B72

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 73 CRVH_CEL_V_B73

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 74 CRVH_CEL_V_B74

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 75 CRVH_CEL_V_B75

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 76 CRVH_CEL_V_B76

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 77 CRVH_CEL_V_B77

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 78 CRVH_CEL_V_B78

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 79 CRVH_CEL_V_B79

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 80 CRVH_CEL_V_B80

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 81 CRVH_CEL_V_B81

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 82 CRVH_CEL_V_B82

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 83 CRVH_CEL_V_B83

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Cell voltage, 84 CRVH_CEL_V_B84

  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Individual cell max SOC, line B CRVH_CEL_MAX_SOC_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Individual cell min SOC, line B CRVH_CEL_MIN_SOC_B

  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Individual cell voltage A1 CRVH_CEL_V_A1Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A2 CRVH_CEL_V_A2Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A3 CRVH_CEL_V_A3Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A4 CRVH_CEL_V_A4Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A5 CRVH_CEL_V_A5Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A6 CRVH_CEL_V_A6Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A7 CRVH_CEL_V_A7Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A8 CRVH_CEL_V_A8Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A9 CRVH_CEL_V_A9Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A10 CRVH_CEL_V_A10Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A11 CRVH_CEL_V_A11Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A12 CRVH_CEL_V_A12Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A13 CRVH_CEL_V_A13Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A14 CRVH_CEL_V_A14Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A15 CRVH_CEL_V_A15Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A16 CRVH_CEL_V_A16Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A17 CRVH_CEL_V_A17Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A18 CRVH_CEL_V_A18Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A19 CRVH_CEL_V_A19Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A20 CRVH_CEL_V_A20Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A21 CRVH_CEL_V_A21Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A22 CRVH_CEL_V_A22Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A23 CRVH_CEL_V_A23Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A24 CRVH_CEL_V_A24Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A25 CRVH_CEL_V_A25Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A26 CRVH_CEL_V_A26Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A27 CRVH_CEL_V_A27Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A28 CRVH_CEL_V_A28Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A29 CRVH_CEL_V_A29Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A30 CRVH_CEL_V_A30Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A31 CRVH_CEL_V_A31Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A32 CRVH_CEL_V_A32Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A33 CRVH_CEL_V_A33Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A34 CRVH_CEL_V_A34Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A35 CRVH_CEL_V_A35Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A36 CRVH_CEL_V_A36Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A37 CRVH_CEL_V_A37Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A38 CRVH_CEL_V_A38Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A39 CRVH_CEL_V_A39Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A40 CRVH_CEL_V_A40Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A41 CRVH_CEL_V_A41Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A42 CRVH_CEL_V_A42Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A43 CRVH_CEL_V_A43Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A44 CRVH_CEL_V_A44Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A45 CRVH_CEL_V_A45Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A46 CRVH_CEL_V_A46Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A47 CRVH_CEL_V_A47Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A48 CRVH_CEL_V_A48Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A49 CRVH_CEL_V_A49Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A50 CRVH_CEL_V_A50Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A51 CRVH_CEL_V_A51Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A52 CRVH_CEL_V_A52Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A53 CRVH_CEL_V_A53Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A54 CRVH_CEL_V_A54Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A55 CRVH_CEL_V_A55Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A56 CRVH_CEL_V_A56Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A57 CRVH_CEL_V_A57Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A58 CRVH_CEL_V_A58Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A59 CRVH_CEL_V_A59Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A60 CRVH_CEL_V_A60Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A61 CRVH_CEL_V_A61Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A62 CRVH_CEL_V_A62Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A63 CRVH_CEL_V_A63Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A64 CRVH_CEL_V_A64Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A65 CRVH_CEL_V_A65Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A66 CRVH_CEL_V_A66Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A67 CRVH_CEL_V_A67Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A68 CRVH_CEL_V_A68Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A69 CRVH_CEL_V_A69Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A70 CRVH_CEL_V_A70Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A71 CRVH_CEL_V_A71Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A72 CRVH_CEL_V_A72Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A73 CRVH_CEL_V_A73Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A74 CRVH_CEL_V_A74Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A75 CRVH_CEL_V_A75Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A76 CRVH_CEL_V_A76Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A77 CRVH_CEL_V_A77Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A78 CRVH_CEL_V_A78Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A79 CRVH_CEL_V_A79Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A80 CRVH_CEL_V_A80Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A81 CRVH_CEL_V_A81Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A82 CRVH_CEL_V_A82Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A83 CRVH_CEL_V_A83Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Individual cell voltage A84 CRVH_CEL_V_A84Confirmed

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Climate

A/C pressure CRVH_AC_P

  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 4000 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Outside air temperature CRVH_AATConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s
  • Testing for 2017 to 2022, 2024

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °F
Unit
°F

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024.

Outside air temperature CRVH_AAT_CConfirmed

  • Service 22DID 7028
  • ModuleDA60 → 60
  • Every5 s

Bits 132 to 143 of the reply, 12 bits. The value is signed.

Formula
val
Range
-40 to 2047 °C
Unit
°C

Confirmed for 2026.

Clocks

Time since engine start CRVH_RUNTMConfirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Time since engine start CRVH_RUNTM_V2

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2021, 2025 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2023, 2026. Supported for 2021, 2025.

ECU

Oil pressure CRVH_EOP

  • Service 22DID 2203
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Variable valve control CRVH_VTEC_CTRLConfirmed

  • Service 22DID 2612
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2017 to 2022, 2024

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Electrical

Brake fluid pressure CRVH_BRK_FLD_PConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Brake pedal stroke CRVH_BRK_PED_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Brake pressure CRVH_BRK_PConfirmed

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Brake switch CRVH_BRK_SWConfirmed

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Master cylinder stroke CRVH_MSTR_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Slave cylinder stroke CRVH_SLV_CYL_STKConfirmed

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Engine

A/C clutch CRVH_AC_CLUTCHConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2023. Supported for 2021, 2026.

Active cylinders CRVH_ACTIVE_CYL

  • Service 22DID 2615
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Air/gas ratio CRVH_AIRGAS_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2017 to 2022, 2024

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Air/gas ratio CRVH_AIRGAS_RATIO_V2

  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Ambient air temperature, cabin CRVH_AAT_CABConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Ambient air temperature, outside CRVH_AAT_OUTConfirmed

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Cabin air temperature CRVH_CABIN_AIR_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 200 to 207 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

0x18 = 24 → 24×1.8+32 = 75.2 °F

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2026. Supported for 2021, 2025.

Catalyst temperature CRVH_CAT_T

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 1500 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023, 2026. Supported for 2021.

DC-DC converter temperature CRVH_DC_DC_CONVERTER_TEMPERATUREConfirmed

  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0000 = 0 → 010 = 0 °C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. Supported for 2021, 2025.

Engine coolant temperature sensor 1 CRVH_ECT_1Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Engine coolant temperature sensor 2 CRVH_ECT_2Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Engine coolant temperature sensor 3 CRVH_ECT_3Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Engine coolant temperature sensor 4 CRVH_ECT_4Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024. Not supported for 2026.

Engine oil temperature, variant 1 CRVH_EOT_VAR_1

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Engine oil temperature, variant 2 CRVH_EOT_VAR_2

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Engine oil temperature, variant 3 CRVH_EOT_VAR_3

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Engine oil temperature, variant 4 CRVH_EOT_VAR_4

  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2023. Supported for 2021, 2025 to 2026.

Fuel/air commanded equivalence ratio CRVH_FUELAIR_CARConfirmed

  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2017 to 2022, 2024

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Generator CRVH_GENERATORConfirmed

  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Knock control CRVH_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2017 to 2022, 2024

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Raw value

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Knock control CRVH_KNOCK_CONTROL_V2

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×1.99255
Range
0 to 1.99
Unit
Number

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, air cleaner CRVH_MAINT_AIR_CLN

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, cabin filter CRVH_MAINT_CABIN_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, engine coolant CRVH_MAINT_COOL

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, general inspection CRVH_MAINT_INSP

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, oil & filter CRVH_MAINT_OIL_FLT

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, rake fluid CRVH_MAINT_BRK_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, spark plugs & valves CRVH_MAINT_SPARK

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, transmission fluid CRVH_MAINT_TRANS_FLD

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2023. Supported for 2021, 2026.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2023. Supported for 2021, 2026.

Misfire count #1 CRVH_MIS_1Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Misfire count #1, variant 1 CRVH_MISFIRE_COUNT_1_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #1, variant 2 CRVH_MISFIRE_COUNT_1_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #1, variant 3 CRVH_MISFIRE_COUNT_1_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #2 CRVH_MIS_2Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Misfire count #2, variant 1 CRVH_MISFIRE_COUNT_2_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #2, variant 2 CRVH_MISFIRE_COUNT_2_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #2, variant 3 CRVH_MISFIRE_COUNT_2_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #3 CRVH_MIS_3Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Misfire count #3, variant 1 CRVH_MISFIRE_COUNT_3_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #3, variant 2 CRVH_MISFIRE_COUNT_3_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #3, variant 3 CRVH_MISFIRE_COUNT_3_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #4 CRVH_MIS_4Confirmed

  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2017 to 2022, 2024

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Misfire count #4, variant 1 CRVH_MISFIRE_COUNT_4_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #4, variant 2 CRVH_MISFIRE_COUNT_4_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #4, variant 3 CRVH_MISFIRE_COUNT_4_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #5, variant 1 CRVH_MISFIRE_COUNT_5_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #5, variant 2 CRVH_MISFIRE_COUNT_5_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #5, variant 3 CRVH_MISFIRE_COUNT_5_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #6, variant 1 CRVH_MISFIRE_COUNT_6_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #6, variant 2 CRVH_MISFIRE_COUNT_6_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Misfire count #6, variant 3 CRVH_MISFIRE_COUNT_6_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Motor inverter, current CRVH_MOTOR_INVERTER_CURRENTConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

0x0000 = 0 → 0100 = 0 A

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Outside air temperature CRVH_OUTSIDE_AIR_TEMPERATUREConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 208 to 215 of the reply, 8 bits.

Formula
val×1.8+32
Range
0 to 491 °F
Unit
°F

0x00 = 0 → 0×1.8+32 = 32 °F

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2023, 2026. Supported for 2021.

Transmission fluid temperature, variant 4 CRVH_ATF_T_VAR_4

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 2201
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Variable timing control duty CRVH_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing for 2017 to 2022, 2024

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

VTEC valve control CRVH_VTEC_VALVE_CTRL

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Internal

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2026.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. Supported for 2021, 2026.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2023, 2026.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023, 2026.

Fuel

Fuel level CRVH_FLVConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2017 to 2022, 2024

Bits 96 to 111 of the reply, 16 bits.

Formula
val100
Range
0 to 655 L
Unit
L

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2023. Supported for 2021, 2026.

Fuel/air commanded equivalence ratio CRVH_FUEL_AIR_RATIOConfirmed

  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2017 to 2022, 2024

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Movement

Generator motor speed CRVH_GENERATOR_MOTOR_SPEEDConfirmed

  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 184 to 191 of the reply, 8 bits.

Formula
val×64
Range
0 to 16320 rpm
Unit
rpm

0x00 = 0 → 0×64 = 0 rpm

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2023, 2026. Supported for 2021, 2025.

Tires

Front left tire pressure CRVH_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Front left tire temperature CRVH_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 200 to 207 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Front right tire pressure CRVH_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Front right tire temperature CRVH_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 192 to 199 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Maintenance, tire rotation CRVH_MAINT_TIRE

  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Rear left tire pressure CRVH_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Rear left tire temperature CRVH_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 216 to 223 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Rear right tire pressure CRVH_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Rear right tire temperature CRVH_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6001
  • ModuleDA26 → 26
  • Every15 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Transmission

Automatic transmission fluid temperature CRVH_ATF_T

  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Current gear CRVH_GEAR_1D

  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Current gear var.2 CRVH_CURRENT_GEAR_VAR_2

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Current gear var.3 CRVH_CURRENT_GEAR_VAR_3

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2017 to 2022, 2024, 2026. Not supported for 2023, 2025, 2027.

Transmission fluid temperature CRVH_ATF_T_DA1E

  • Service 22DID 3083
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 200 °C
Unit
°C

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Transmission gear CRVH_GEAR

  • Service 22DID 3086
  • ModuleDA1E → 1E
  • Every250 ms
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0PPark
1D1Drive 1
2D2Drive 2
3D3Drive 3
4D4Drive 4
5D5Drive 5
6D6Drive 6
7D7Drive 7
8D8Drive 8
9D9Drive 9
14NNeutral
15RReverse

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Trips

Odometer CRVH_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2017 to 2022, 2024, 2026

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2023, 2025, 2027. In testing for 2017 to 2022, 2024, 2026.

Odometer CRVH_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA1D → 1D
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2017 to 2022, 2024. Not supported for 2023, 2025 to 2027.

Odometer, variation 3 CRVH_ODO_V3Confirmed

  • Service 22DID 7022
  • ModuleDA60 → 60
  • Every30 s
  • Testing for 2017 to 2022, 2024

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 200000 mi
Unit
mi

Confirmed for 2023, 2025 to 2027. In testing for 2017 to 2022, 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.