Parameters
The Honda Clarity has 425 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery coolant temperature CLARITY_BATTERY_COOLANT_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Example reply from a 2018 Honda Clarity.
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Battery module power CLARITY_BATTERY_MODULE_POWERConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Example reply from a 2018 Honda Clarity.
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -524.288 to 524.272 kW
- Unit
- kW
0x0000 = 0 → = 0 kW
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage limit during charge CLARITY_CEL_V_LIMConfirmed
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Charging voltage target CLARITY_CHG_V_TGTConfirmed
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2018, 2022. Supported for 2019, 2021.
Distance traveled since last charge CLARITY_BAT_DISTConfirmed
- Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 80 to 111 of the reply, 32 bits.
- Formula
- Range
- 0 to 250000 km
- Unit
- km
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 13 to 14 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
2 | CIM | Charge increasing mode |
3 | Not PSA |
Confirmed for 2018, 2022.
High voltage battery cells, max state of charge CLARITY_CELL_MAX_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery cells, max state of charge CLARITY_CELL_MIN_SOCConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 1A temperature CLARITY_HVB_MOD_1A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 1B temperature CLARITY_HVB_MOD_1B_TConfirmed
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 2A temperature CLARITY_HVB_MOD_2A_TConfirmed
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 488 to 503 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 3A temperature CLARITY_HVB_MOD_3A_TConfirmed
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 3B temperature CLARITY_HVB_MOD_3B_TConfirmed
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery module 4B temperature CLARITY_HVB_MOD_4B_TConfirmed
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 520 to 535 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery total capacity CLARITY_HVB_CAPConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery total current CLARITY_HVB_C_TOTALConfirmed
Pelican can show this parameter as the traction battery current.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 200 A
- Unit
- A
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery voltage CLARITY_HVB_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
High voltage battery voltage, line b CLARITY_HVB_V_BConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
HV battery cell max state of charge CLARITY_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
HV battery current CLARITY_HV_BATTERY_CURRENTConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
HV battery fan 3 speed CLARITY_HV_BATTERY_FAN_3_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Supported for 2018.
HV battery max cell voltage CLARITY_HV_BATTERY_MAX_CELL_VOLTAGE
- Service 22
DID 2222 - Module
DBEF - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
HV battery usable capacity CLARITY_HV_BATTERY_USABLE_CAPACITYConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed
The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).
Pelican can show this parameter as the state of charge.
- Service 01
PID 5B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019, 2021 to 2022.
Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2018, 2022.
Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.98 V
- Unit
- V
Confirmed for 2018, 2022.
Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | CSM | Charge sustaining mode |
1 | CDM | Charge depleting mode |
Confirmed for 2018, 2022.
Normal charger input voltage CLARITY_CHG_V_INConfirmed
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Normal charger output voltage CLARITY_CHG_V_OUTConfirmed
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
State of charge CLARITY_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
State of charge CLARITY_STATE_OF_CHARGEConfirmed
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cells
Battery capacity, line b CLARITY_HVB_CAP_BConfirmed
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 1 CLARITY_CEL_V_B1Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 2 CLARITY_CEL_V_B2Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 3 CLARITY_CEL_V_B3Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 4 CLARITY_CEL_V_B4Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 5 CLARITY_CEL_V_B5Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 6 CLARITY_CEL_V_B6Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 7 CLARITY_CEL_V_B7Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 8 CLARITY_CEL_V_B8Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 9 CLARITY_CEL_V_B9Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 10 CLARITY_CEL_V_B10Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 11 CLARITY_CEL_V_B11Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 12 CLARITY_CEL_V_B12Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 13 CLARITY_CEL_V_B13Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 14 CLARITY_CEL_V_B14Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 15 CLARITY_CEL_V_B15Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 16 CLARITY_CEL_V_B16Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 17 CLARITY_CEL_V_B17Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 18 CLARITY_CEL_V_B18Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 19 CLARITY_CEL_V_B19Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 20 CLARITY_CEL_V_B20Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 21 CLARITY_CEL_V_B21Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 22 CLARITY_CEL_V_B22Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 23 CLARITY_CEL_V_B23Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 24 CLARITY_CEL_V_B24Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 25 CLARITY_CEL_V_B25Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 26 CLARITY_CEL_V_B26Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 27 CLARITY_CEL_V_B27Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 28 CLARITY_CEL_V_B28Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 29 CLARITY_CEL_V_B29Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 30 CLARITY_CEL_V_B30Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 31 CLARITY_CEL_V_B31Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 32 CLARITY_CEL_V_B32Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 33 CLARITY_CEL_V_B33Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 34 CLARITY_CEL_V_B34Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 35 CLARITY_CEL_V_B35Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 36 CLARITY_CEL_V_B36Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 37 CLARITY_CEL_V_B37Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 38 CLARITY_CEL_V_B38Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 39 CLARITY_CEL_V_B39Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 40 CLARITY_CEL_V_B40Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 41 CLARITY_CEL_V_B41Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 42 CLARITY_CEL_V_B42Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 43 CLARITY_CEL_V_B43Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 44 CLARITY_CEL_V_B44Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 45 CLARITY_CEL_V_B45Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 46 CLARITY_CEL_V_B46Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 47 CLARITY_CEL_V_B47Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 48 CLARITY_CEL_V_B48Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 49 CLARITY_CEL_V_B49Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 50 CLARITY_CEL_V_B50Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 51 CLARITY_CEL_V_B51Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 52 CLARITY_CEL_V_B52Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 53 CLARITY_CEL_V_B53Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 54 CLARITY_CEL_V_B54Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 55 CLARITY_CEL_V_B55Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 56 CLARITY_CEL_V_B56Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 57 CLARITY_CEL_V_B57Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 58 CLARITY_CEL_V_B58Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 59 CLARITY_CEL_V_B59Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 60 CLARITY_CEL_V_B60Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 61 CLARITY_CEL_V_B61Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 62 CLARITY_CEL_V_B62Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 63 CLARITY_CEL_V_B63Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 64 CLARITY_CEL_V_B64Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 65 CLARITY_CEL_V_B65Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 66 CLARITY_CEL_V_B66Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 67 CLARITY_CEL_V_B67Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 68 CLARITY_CEL_V_B68Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 69 CLARITY_CEL_V_B69Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 70 CLARITY_CEL_V_B70Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 71 CLARITY_CEL_V_B71Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 72 CLARITY_CEL_V_B72Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 73 CLARITY_CEL_V_B73Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 74 CLARITY_CEL_V_B74Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 75 CLARITY_CEL_V_B75Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 76 CLARITY_CEL_V_B76Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 77 CLARITY_CEL_V_B77Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 78 CLARITY_CEL_V_B78Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 79 CLARITY_CEL_V_B79Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 80 CLARITY_CEL_V_B80Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 81 CLARITY_CEL_V_B81Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 82 CLARITY_CEL_V_B82Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 83 CLARITY_CEL_V_B83Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Cell voltage, 84 CLARITY_CEL_V_B84Confirmed
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell max SOC, line b CLARITY_CEL_MAX_SOC_BConfirmed
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell min SOC, line b CLARITY_CEL_MIN_SOC_BConfirmed
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A1 CLARITY_CEL_V_A1Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A2 CLARITY_CEL_V_A2Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A3 CLARITY_CEL_V_A3Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A4 CLARITY_CEL_V_A4Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A5 CLARITY_CEL_V_A5Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A6 CLARITY_CEL_V_A6Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A7 CLARITY_CEL_V_A7Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A8 CLARITY_CEL_V_A8Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A9 CLARITY_CEL_V_A9Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A10 CLARITY_CEL_V_A10Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A11 CLARITY_CEL_V_A11Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A12 CLARITY_CEL_V_A12Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A13 CLARITY_CEL_V_A13Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A14 CLARITY_CEL_V_A14Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A15 CLARITY_CEL_V_A15Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A16 CLARITY_CEL_V_A16Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A17 CLARITY_CEL_V_A17Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A18 CLARITY_CEL_V_A18Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A19 CLARITY_CEL_V_A19Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A20 CLARITY_CEL_V_A20Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A21 CLARITY_CEL_V_A21Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A22 CLARITY_CEL_V_A22Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A23 CLARITY_CEL_V_A23Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A24 CLARITY_CEL_V_A24Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A25 CLARITY_CEL_V_A25Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A26 CLARITY_CEL_V_A26Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A27 CLARITY_CEL_V_A27Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A28 CLARITY_CEL_V_A28Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A29 CLARITY_CEL_V_A29Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A30 CLARITY_CEL_V_A30Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A31 CLARITY_CEL_V_A31Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A32 CLARITY_CEL_V_A32Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A33 CLARITY_CEL_V_A33Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A34 CLARITY_CEL_V_A34Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A35 CLARITY_CEL_V_A35Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A36 CLARITY_CEL_V_A36Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A37 CLARITY_CEL_V_A37Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A38 CLARITY_CEL_V_A38Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A39 CLARITY_CEL_V_A39Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A40 CLARITY_CEL_V_A40Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A41 CLARITY_CEL_V_A41Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A42 CLARITY_CEL_V_A42Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A43 CLARITY_CEL_V_A43Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A44 CLARITY_CEL_V_A44Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A45 CLARITY_CEL_V_A45Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A46 CLARITY_CEL_V_A46Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A47 CLARITY_CEL_V_A47Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A48 CLARITY_CEL_V_A48Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A49 CLARITY_CEL_V_A49Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A50 CLARITY_CEL_V_A50Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A51 CLARITY_CEL_V_A51Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A52 CLARITY_CEL_V_A52Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A53 CLARITY_CEL_V_A53Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A54 CLARITY_CEL_V_A54Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A55 CLARITY_CEL_V_A55Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A56 CLARITY_CEL_V_A56Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A57 CLARITY_CEL_V_A57Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A58 CLARITY_CEL_V_A58Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A59 CLARITY_CEL_V_A59Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A60 CLARITY_CEL_V_A60Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A61 CLARITY_CEL_V_A61Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A62 CLARITY_CEL_V_A62Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A63 CLARITY_CEL_V_A63Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A64 CLARITY_CEL_V_A64Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A65 CLARITY_CEL_V_A65Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A66 CLARITY_CEL_V_A66Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A67 CLARITY_CEL_V_A67Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A68 CLARITY_CEL_V_A68Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A69 CLARITY_CEL_V_A69Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A70 CLARITY_CEL_V_A70Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A71 CLARITY_CEL_V_A71Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Individual cell voltage A72 CLARITY_CEL_V_A72Confirmed
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Internal
Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022.
Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022.
Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022.
Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed
- Service 01
PID 9A - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022.
Climate
A/C pressure CLARITY_AC_PConfirmed
- Service 22
DID 2613 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 4000 kPa
- Unit
- kPa
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. Supported for 2019, 2021.
Outside air temperature CLARITY_AATConfirmed
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2020 to 2022
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
Confirmed for 2018 to 2019. In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Not supported for 2022.
Clocks
Time since engine start CLARITY_RUNTM
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Supported for 2018. Not supported for 2019, 2022.
Time since engine start CLARITY_RUNTM_PCMConfirmed
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Time since engine start CLARITY_RUNTM_V2
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA11 → 11 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2018. Supported for 2019, 2021.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022. Supported for 2019, 2021.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022. Supported for 2019, 2021.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018 to 2019, 2021 to 2022.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018, 2022. Supported for 2019, 2021.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018, 2022. Supported for 2019, 2021.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2018, 2022. Supported for 2019, 2021.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. Supported for 2019, 2021.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2018, 2022. Supported for 2019, 2021.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2018, 2022. Supported for 2019, 2021.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2022. Supported for 2018 to 2019, 2021.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018, 2022. Supported for 2019, 2021.
ECU
Knock control CLARITY_KNOCK_CTRL_PCMConfirmed
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 1 CLARITY_MIS_1_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 2 CLARITY_MIS_2_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 3 CLARITY_MIS_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 4 CLARITY_MIS_4_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 5 CLARITY_MIS_5_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count, cylinder 6 CLARITY_MIS_6_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Oil pressure CLARITY_EOP
- Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2008 to 2014, 2016 to 2017, 2020. Not supported for 2018 to 2019, 2021 to 2022.
Variable valve control CLARITY_VTEC_CTRL
- Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020 to 2022. Not supported for 2018 to 2019.
Electrical
Brake fluid pressure CLARITY_BRK_FLD_PConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Brake pedal stroke CLARITY_BRK_PED_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 mm
- Unit
- mm
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Brake pressure CLARITY_BRK_PConfirmed
- Service 22
DID 4005 - Module
DA28 → 28 - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Brake switch CLARITY_BRK_SWConfirmed
- Service 22
DID 4004 - Module
DA28 → 28 - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Master cylinder stroke CLARITY_MSTR_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Slave cylinder stroke CLARITY_SLV_CYL_STKConfirmed
- Service 22
DID 4201 - Module
DA2A → 2A - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 mm
- Unit
- mm
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine
A/C clutch CLARITY_AC_CLU_PCMConfirmed
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
A/C clutch CLARITY_AC_CLUTCH
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed
Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 53 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 327.675 kPa
- Unit
- kPa
Confirmed for 2018, 2022. Supported for 2019, 2021.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2018, 2022. Supported for 2019, 2021.
Active cylinders CLARITY_ACTIVE_CYL
- Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Active cylinders CLARITY_ACTIVE_CYL_PCM
- Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
Air conditioner clutch CLARITY_AC_CLU_DA11
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Air/gas ratio CLARITY_AIRGAS_RATIO
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Air/gas ratio CLARITY_AIRGAS_RATIO_PCMConfirmed
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Air/gas ratio CLARITY_AIRGAS_RATIO_V2
- Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Ambient air temperature, cabin CLARITY_AAT_CABConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Ambient air temperature, outside CLARITY_AAT_OUTConfirmed
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2019, 2021.
Cabin air temperature CLARITY_CABIN_AIR_TEMPERATUREConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2021.
Catalyst temperature CLARITY_CAT_T
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018. Supported for 2019, 2021.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018 to 2019. Supported for 2021.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
DC-DC converter temperature CLARITY_DC_DC_CONVERTER_TEMPERATUREConfirmed
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Example reply from a 2018 Honda Clarity.
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0000 = 0 → = 0 °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
EGR error EGR_ERRSAE J1979Confirmed
- Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018. Supported for 2019, 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018 to 2019. Supported for 2021.
Engine coolant temperature sensor 1 CLARITY_ECT_1Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine coolant temperature sensor 2 CLARITY_ECT_2Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine coolant temperature sensor 3 CLARITY_ECT_3Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine coolant temperature sensor 4 CLARITY_ECT_4Confirmed
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine oil temperature, variant 1 CLARITY_EOT_VAR_1
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2020, 2022. Not supported for 2018, 2021.
Engine oil temperature, variant 2 CLARITY_EOT_VAR_2
- Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2020, 2022. Not supported for 2018, 2021.
Engine oil temperature, variant 3 CLARITY_EOT_VAR_3
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Engine oil temperature, variant 4 CLARITY_EOT_VAR_4
- Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2018. Supported for 2019, 2021.
Fuel/air commanded equivalence ratio CLARITY_FUELAIR_CAR
- Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Fuel/air commanded equivalence ratio CLARITY_FUELAIR_CAR_PCMConfirmed
- Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Generator CLARITY_GENERATOR
- Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Generator CLARITY_GENERATOR_DA11
- Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Generator CLARITY_GENERATOR_PCMConfirmed
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Knock control CLARITY_KNOCK_CONTROL
ECU's determination of fuel quality.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Raw value
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Knock control CLARITY_KNOCK_CONTROL_V2
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Maintenance, air cleaner CLARITY_MAINT_AIR_CLNConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, cabin filter CLARITY_MAINT_CABIN_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, engine coolant CLARITY_MAINT_COOLConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, general inspection CLARITY_MAINT_INSPConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, oil & filter CLARITY_MAINT_OIL_FLTConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, rake fluid CLARITY_MAINT_BRK_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, spark plugs & valves CLARITY_MAINT_SPARKConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Maintenance, transmission fluid CLARITY_MAINT_TRANS_FLDConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2018.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2018.
Misfire count #1 CLARITY_MIS_1
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Misfire count #1, variant 1 CLARITY_MIS_CNT_1_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #1, variant 3 CLARITY_MIS_CNT_1_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #2 CLARITY_MIS_2
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Misfire count #2, variant 1 CLARITY_MIS_CNT_2_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #2, variant 3 CLARITY_MIS_CNT_2_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #3 CLARITY_MIS_3
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Misfire count #3, variant 1 CLARITY_MIS_CNT_3_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #3, variant 3 CLARITY_MIS_CNT_3_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #4 CLARITY_MIS_4
- Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Misfire count #4, variant 1 CLARITY_MIS_CNT_4_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #4, variant 3 CLARITY_MIS_CNT_4_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #5, variant 1 CLARITY_MIS_CNT_5_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #5, variant 3 CLARITY_MIS_CNT_5_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #6, variant 1 CLARITY_MIS_CNT_6_VAR_1_PCMConfirmed
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count #6, variant 3 CLARITY_MIS_CNT_6_VAR_3_PCMConfirmed
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Misfire count 1 CLARITY_MIS_CNT_1
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Misfire count 1,, variant 1 CLARITY_MIS_CNT_1_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 1,, variant 2 CLARITY_MIS_CNT_1_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 1,, variant 3 CLARITY_MIS_CNT_1_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 2 CLARITY_MIS_CNT_2
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Misfire count 2,, variant 1 CLARITY_MIS_CNT_2_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 2,, variant 2 CLARITY_MIS_CNT_2_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 2,, variant 3 CLARITY_MIS_CNT_2_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 3 CLARITY_MIS_CNT_3
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Misfire count 3,, variant 1 CLARITY_MIS_CNT_3_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 3,, variant 2 CLARITY_MIS_CNT_3_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 3,, variant 3 CLARITY_MIS_CNT_3_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 4 CLARITY_MIS_CNT_4
- Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022. Not supported for 2018.
Misfire count 4,, variant 1 CLARITY_MIS_CNT_4_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 4,, variant 2 CLARITY_MIS_CNT_4_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 4,, variant 3 CLARITY_MIS_CNT_4_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 5,, variant 1 CLARITY_MIS_CNT_5_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 5,, variant 2 CLARITY_MIS_CNT_5_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 5,, variant 3 CLARITY_MIS_CNT_5_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 6,, variant 1 CLARITY_MIS_CNT_6_VAR_1
- Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 6,, variant 2 CLARITY_MIS_CNT_6_VAR_2
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Misfire count 6,, variant 3 CLARITY_MIS_CNT_6_VAR_3
- Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Motor inverter, current CLARITY_MOTOR_INVERTER_CURRENTConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2021.
Variable timing control duty CLARITY_VARIABLE_TIM_CTRL
- Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Variable timing control duty CLARITY_VTC_DUTY
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Variable valve timing duty CLARITY_VTC_DUTY_PCMConfirmed
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
VTEC valve control CLARITY_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bit 175 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Internal
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2022. Supported for 2018 to 2019, 2021.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018 to 2019. Supported for 2021.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2018 to 2019. Supported for 2021.
Fuel
Air-fuel mixture heater CLARITY_AIR_FUEL_MIXTUREConfirmed
- Service 22
DID 266D - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2018.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2018.
Fuel level CLARITY_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 2008 to 2014, 2016 to 2017, 2020
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2018 to 2019, 2021. In testing for 2008 to 2014, 2016 to 2017, 2020.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018, 2022. Supported for 2019, 2021.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2018, 2022. Supported for 2019, 2021.
Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022. Supported for 2019, 2021.
Fuel/air commanded equivalence ratio CLARITY_FUEL_AIR_RAT_PCMConfirmed
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Fuel/air commanded equivalence ratio CLARITY_FUEL_AIR_RATIO
- Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2018.
Internal
Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed
- Service 01
PID 9F - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Movement
Generator motor speed CLARITY_GENERATOR_MOTOR_SPEEDConfirmed
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Example reply from a 2018 Honda Clarity.
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 16320 rpm
- Unit
- rpm
0x00 = 0 → = 0 rpm
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2018 to 2019, 2021 to 2022.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2018. Supported for 2019, 2021.
Tires
Maintenance, tire rotation CLARITY_MAINT_TIREConfirmed
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Transmission
Automatic transmission fluid temperature CLARITY_ATF_T
- Service 22
DID 2201 - Module
DA1D → 1D - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Supported for 2018. Not supported for 2019, 2021.
Current gear CLARITY_GEAR_1D
- Service 22
DID 2221 - Module
DA1D → 1D - Every
1 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Supported for 2018. Not supported for 2019, 2022.
Current gear var.2 CLARITY_CURRENT_GEAR_VAR_2Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2020
Bits 352 to 359 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018, 2022. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2020.
Current gear var.3 CLARITY_CURRENT_GEAR_VAR_3Confirmed
- Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2020
Bits 368 to 375 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2018, 2022. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2020.
Trips
Odometer CLARITY_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2008 to 2014, 2016 to 2017, 2020 to 2021. Supported for 2018. Not supported for 2019, 2022.
Odometer CLARITY_ODO_PCMConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.
Odometer CLARITY_ODO_V2
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2008 to 2014, 2016 to 2017, 2020, 2022. Not supported for 2018 to 2019, 2021.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2022.
Odometer, variation 3 CLARITY_ODO_V3Confirmed
- Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing for 2008 to 2014, 2016 to 2017, 2019 to 2022
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
Confirmed for 2018. In testing for 2008 to 2014, 2016 to 2017, 2019 to 2022.