Haval Jolion

Parameters

The Haval Jolion has 69 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level, liters JOLION_FUEL_LEVEL_LITERSConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 0106
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

0x0046 = 70 → 7010 = 7 L

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery voltage JOLION_BATTERY_VOLTAGE

  • Service 22DID 1702
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5100
Range
0 to 31.875 V
Unit
V

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Climate

A/C pressure JOLION_AC_PRESSURE_HVAC

  • Service 22DID 1469
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×125010000−4096
Range
-4096 to 4095.875 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

A/C pressure, enhanced JOLION_AC_PRESSURE_HVAC2Confirmed

  • Service 22DID 210C
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×210
Range
-6553.6 to 6553.4 kPa
Unit
kPa

0x0000 = 0 → 0×210 = 0 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Drivetrain

Engine net torque JOLION_TRANSMISSION_ENGINE_NET_TORQUE

  • Service 22DID 6915
  • Module7E1
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−510
Range
-510 to 65025 N·m
Unit
N·m

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Engine torque JOLION_TRANSMISSION_ENGINE_TORQUE

  • Service 22DID 6915
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×4
Range
-512 to 508 N·m
Unit
N·m

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Engine

Boost pressure JOLION_BOOST_PRESSURE_VALUEConfirmed

  • Service 22DID 016A
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x0000 = 0 → 0128 = 0 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Boost pressure, actual JOLION_BP_ACTUALConfirmed

  • Service 22DID 010F
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x26B8 = 9912 → 9912128 = 77.4375 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Boost pressure, target JOLION_BP_TARGETConfirmed

  • Service 22DID 0112
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x0000 = 0 → 0128 = 0 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Injection pulse width JOLION_INJECTION_PULSE_WIDTHConfirmed

  • Service 22DID 016D
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 ms
Unit
ms

0x00000000 = 0 → 01000 = 0 ms

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock counter JOLION_KNOCK_COUNTER

  • Service 22DID 11A0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Knock retard JOLION_KNOCK_RETARD

  • Service 22DID 11A6
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8.82100
Range
0 to 22.491 °
Unit
°

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Knock retard cylinder 1 JOLION_INJECTION_KNOCK_RETARD_CYL_1Confirmed

  • Service 22DID 0170
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×0.75 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard cylinder 2 JOLION_INJECTION_KNOCK_RETARD_CYL_2Confirmed

  • Service 22DID 0171
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×0.75 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard cylinder 3 JOLION_INJECTION_KNOCK_RETARD_CYL_3Confirmed

  • Service 22DID 0172
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×0.75 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard cylinder 4 JOLION_INJECTION_KNOCK_RETARD_CYL_4Confirmed

  • Service 22DID 0173
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×0.75 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor reference voltage cylinder 1 JOLION_KNOCK_SENSOR_REFERENCE_CYL_1Confirmed

  • Service 22DID 0174
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00007625
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor reference voltage cylinder 2 JOLION_KNOCK_SENSOR_REFERENCE_CYL_2Confirmed

  • Service 22DID 0175
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00007625
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor reference voltage cylinder 3 JOLION_KNOCK_SENSOR_REFERENCE_CYL_3Confirmed

  • Service 22DID 0176
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00007625
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor reference voltage cylinder 4 JOLION_KNOCK_SENSOR_REFERENCE_CYL_4Confirmed

  • Service 22DID 0177
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00007625
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfire current, total JOLION_MISFIRE_CURRENT_TOTAL

  • Service 22DID 1200
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256
Range
0 to 65280
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Oil pressure JOLION_OIL_PRESSURE

  • Service 22DID FD19
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×156.2510000
Range
0 to 1023.984375 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Oil temperature JOLION_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1602
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Oil temperature, model JOLION_OIL_TConfirmed

  • Service 22DID 0107
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280.35 °C
Unit
°C

0x0B59 = 2905 → 290510−273.15 = 17.35 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet pressure, model JOLION_PRESSURE_BEFORE_TURBOCHARGERConfirmed

  • Service 22DID 0113
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x26D1 = 9937 → 9937128 = 77.632813 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet temperature, model JOLION_AIR_T_BEFORE_TURBOCHARGERConfirmed

  • Service 22DID 0114
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023437−273.15
Range
-273.15 to 1262.793795 °C
Unit
°C

0x56C8 = 22216 → 22216×0.023437−273.15 = 247.526392 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Variable clutch pressure control, min oil temperature JOLION_OT_VCPC_MIN

  • Service 22DID 1603
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires

Misfire current cylinder 1 JOLION_MISFIRE_CURRENT_CYL_1

  • Service 22DID 1206
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire current cylinder 2 JOLION_MISFIRE_CURRENT_CYL_2

  • Service 22DID 1205
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire current cylinder 3 JOLION_MISFIRE_CURRENT_CYL_3

  • Service 22DID 1207
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire current cylinder 4 JOLION_MISFIRE_CURRENT_CYL_4

  • Service 22DID 1208
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire history cylinder 1 JOLION_MISFIRE_HISTORY_CYL_1

  • Service 22DID 1201
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire history cylinder 2 JOLION_MISFIRE_HISTORY_CYL_2

  • Service 22DID 1202
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire history cylinder 3 JOLION_MISFIRE_HISTORY_CYL_3

  • Service 22DID 1203
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfire history cylinder 4 JOLION_MISFIRE_HISTORY_CYL_4

  • Service 22DID 1204
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires cylinder 1 JOLION_MISFIRES_CYL_1Confirmed

  • Service 22DID 0180
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires cylinder 2 JOLION_MISFIRES_CYL_2Confirmed

  • Service 22DID 0183
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires cylinder 3 JOLION_MISFIRES_CYL_3Confirmed

  • Service 22DID 0181
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires cylinder 4 JOLION_MISFIRES_CYL_4Confirmed

  • Service 22DID 0182
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires total JOLION_MISFIRES_TOTALConfirmed

  • Service 22DID 017F
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Fuel

Fuel flow JOLION_FUEL_FLOWConfirmed

  • Service 22DID 0111
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00429156
Range
0 to 281.2473846 L
Unit
L

0x0000 = 0 → 0×0.00429156 = 0 L

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Fuel level JOLION_FUEL_LEVEL_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Fuel level, liters JOLION_FUEL_LEVEL_LITERSConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 0106
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

0x0046 = 70 → 7010 = 7 L

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Fuel level, output JOLION_FUEL_LEVEL_OUTPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 12C5
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Movement

Front left wheel speed JOLION_FRONT_LEFT_VSSConfirmed

  • Service 22DID 6303
  • Module782 → 7C2
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 3686.34375 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Front right wheel speed JOLION_FRONT_RIGHT_VSSConfirmed

  • Service 22DID 6303
  • Module782 → 7C2
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 3686.34375 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Rear left wheel speed JOLION_REAR_LEFT_VSSConfirmed

  • Service 22DID 6303
  • Module782 → 7C2
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 3686.34375 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Rear right wheel speed JOLION_REAR_RIGHT_VSSConfirmed

  • Service 22DID 6303
  • Module782 → 7C2
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 48 to 63 of the reply, 16 bits.

Formula
val×0.05625
Range
0 to 3686.34375 km/h
Unit
km/h

0x0000 = 0 → 0×0.05625 = 0 km/h

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Transmission electric pump speed JOLION_TRANSMISSION_ELECTRIC_PUMP_SPEED

  • Service 22DID 6A1A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission even axis speed JOLION_TRANSMISSION_EVEN_AXIS_SPEED

  • Service 22DID 6903
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission input shaft speed JOLION_TRANSMISSION_INPUT_SHAFT_SPEED

  • Service 22DID 690D
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission odd axis speed JOLION_TRANSMISSION_ODD_AXIS_SPEED

  • Service 22DID 6902
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission

Clutch 1 pressure JOLION_TRANSMISSION_CLUTCH_1_PRESSURE

  • Service 22DID 690B
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−200
Range
-200 to 6353.5 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Clutch 1 torque JOLION_TRANSMISSION_CLUTCH_1_TORQUE

  • Service 22DID 6932
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 N·m
Unit
N·m

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Clutch 2 pressure JOLION_TRANSMISSION_CLUTCH_2_PRESSURE

  • Service 22DID 690C
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−200
Range
-200 to 6353.5 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Clutch 2 torque JOLION_TRANSMISSION_CLUTCH_2_TORQUE

  • Service 22DID 6933
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 N·m
Unit
N·m

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Clutch temperature JOLION_TRANSMISSION_CLUTCH_TEMP

  • Service 22DID 6934
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−55
Range
-55 to 965 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Clutch temperature v2 JOLION_TRANSMISSION_CLUTCH_TEMP_V1

  • Service 22DID 6A0A
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−55
Range
-55 to 965 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Current gear JOLION_GEARConfirmed

  • Service 22DID 0132
  • Module7E0
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Current gear JOLION_TRANSMISSION_CURRENT_GEAR

  • Service 22DID 6925
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Even clutch actual pressure JOLION_TRANSMISSION_EVEN_CLUTCH_ACTUAL_PRESSURE

  • Service 22DID 690C
  • Module7E1
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val−2000
Range
-2000 to 63535 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Even clutch requested pressure JOLION_TRANSMISSION_EVEN_CLUTCH_REQUESTED_PRESSURE

  • Service 22DID 69BD
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Odd clutch actual pressure JOLION_TRANSMISSION_ODD_CLUTCH_ACTUAL_PRESSURE

  • Service 22DID 690B
  • Module7E1
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val−2000
Range
-2000 to 63535 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Odd clutch requested pressure JOLION_TRANSMISSION_ODD_CLUTCH_REQUESTED_PRESSURE

  • Service 22DID 69BC
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Target gear JOLION_TRANSMISSION_TARGET_GEAR

  • Service 22DID 6926
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature JOLION_TFT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D126
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission temperature, pan JOLION_TFT_PAN

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 6A0A
  • Module7E1
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−55
Range
-55 to 65480 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Trips

Odometer, engine JOLION_ODO_ENG

Pelican can show this parameter as the odometer.

  • Service 22DID 121E
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission odometer JOLION_ODO_TRANS

Pelican can show this parameter as the odometer.

  • Service 22DID 6901
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Vehicle odometer JOLION_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 00A6
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.