Haval Jolion HEV

Parameters

The Haval Jolion HEV has 103 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery voltage JOLIONHEV_BMS_PACK_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID E006
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0D1F = 3359 → 335910 = 335.9 V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Accumulated charge, pack, counter 1 JOLIONHEV_BMS_PACK_ACCUMULATED_CHARGE_1Confirmed

  • Service 22DID E15B
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x0000B0D7 = 45271 → 4527110 = 4,527.1 Ah

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Accumulated charge, pack, counter 2 JOLIONHEV_BMS_PACK_ACCUMULATED_CHARGE_2Confirmed

  • Service 22DID E15C
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 Ah
Unit
Ah

0x0000B017 = 45079 → 4507910 = 4,507.9 Ah

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Battery current, bus JOLIONHEV_BMS_BUS_CURRENTConfirmed

  • Service 22DID E0A4
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−1200
Range
-1200 to 11907 A
Unit
A

0x1741 = 5953 → 59535−1200 = -9.4 A

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Battery voltage JOLIONHEV_BATTERY_VOLTAGE

  • Service 22DID 1702
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5100
Range
0 to 31.875 V
Unit
V

In testing for 2021 to 2026.

Cell position, maximum voltage JOLIONHEV_BMS_MAX_CELL_VOLTAGE_POSITIONConfirmed

  • Service 22DID E00A
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
1 to 256
Unit
Number

0x00 = 0 → 0+1 = 1

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell position, minimum voltage JOLIONHEV_BMS_MIN_CELL_VOLTAGE_POSITIONConfirmed

  • Service 22DID E00B
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
1 to 256
Unit
Number

0x0F = 15 → 15+1 = 16

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell state of charge, maximum JOLIONHEV_BMS_MAX_CELL_SOCConfirmed

  • Service 22DID E0F1
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x01F5 = 501 → 50110 = 50.1 %

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell state of charge, minimum JOLIONHEV_BMS_MIN_CELL_SOCConfirmed

  • Service 22DID E0F2
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x01E1 = 481 → 48110 = 48.1 %

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell voltage, maximum JOLIONHEV_BMS_CELL_VOLTAGE_MAXConfirmed

  • Service 22DID E008
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x0E48 = 3656 → 3,656 mV

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell voltage, minimum JOLIONHEV_BMS_CELL_VOLTAGE_MINConfirmed

  • Service 22DID E009
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mV
Unit
mV

0x0E3D = 3645 → 3,645 mV

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Cell voltages, total JOLIONHEV_BMS_TOTAL_CELL_VOLTAGESConfirmed

  • Service 22DID E007
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val+1
Range
1 to 65536 V
Unit
V

0x014F = 335 → 335+1 = 336 V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Coolant inlet temperature, pack JOLIONHEV_BMS_PACK_LOOP_INLET_TConfirmed

  • Service 22DID E0E4
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Discharge current limit, pack JOLIONHEV_BMS_PACK_DISCHARGE_CURRENT_LIMITConfirmed

  • Service 22DID E0C6
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−1200
Range
-1200 to 11907 A
Unit
A

0x1D0C = 7436 → 74365−1200 = 287.2 A

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Discharge power limit, pack, 2 seconds JOLIONHEV_BMS_PACK_2S_DISCHARGE_POWER_LIMITConfirmed

  • Service 22DID E13D
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kW
Unit
kW

0x0199 = 409 → 4095 = 81.8 kW

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Discharge power limit, pack, 10 seconds JOLIONHEV_BMS_PACK_10S_DISCHARGE_POWER_LIMITConfirmed

  • Service 22DID E13E
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kW
Unit
kW

0x012B = 299 → 2995 = 59.8 kW

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

HV battery voltage JOLIONHEV_BMS_PACK_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID E006
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

0x0D1F = 3359 → 335910 = 335.9 V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Module temperature, average JOLIONHEV_BMS_MODULE_T_AVERAGEConfirmed

  • Service 22DID E0A1
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Module temperature, maximum JOLIONHEV_BMS_MODULE_T_MAXIMUMConfirmed

  • Service 22DID E088
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Module temperature, minimum JOLIONHEV_BMS_MODULE_T_MINIMUMConfirmed

  • Service 22DID E089
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x39 = 57 → 57−40 = 17 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Recharge current limit, pack JOLIONHEV_BMS_PACK_RECHARGE_CURRENT_LIMITConfirmed

  • Service 22DID E0C8
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5−1200
Range
-1200 to 11907 A
Unit
A

0x13E1 = 5089 → 50895−1200 = -182.2 A

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Recharge power limit, pack, 2 seconds JOLIONHEV_BMS_PACK_2S_RECHARGE_POWER_LIMITConfirmed

  • Service 22DID E13F
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kW
Unit
kW

0x00CD = 205 → 2055 = 41 kW

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Recharge power limit, pack, 10 seconds JOLIONHEV_BMS_PACK_10S_RECHARGE_POWER_LIMITConfirmed

  • Service 22DID E140
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kW
Unit
kW

0x00AD = 173 → 1735 = 34.6 kW

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Sleep duration, last JOLIONHEV_BMS_LAST_SLEEP_DURATIONConfirmed

  • Service 22DID E0DD
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

0x0000055F = 1375 → 1,375 s

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

State of charge JOLIONHEV_BMS_BATT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID E0F4
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x01E9 = 489 → 48910 = 48.9 %

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

State of energy JOLIONHEV_BMS_PACK_SOEConfirmed

Pelican can show this parameter as the traction battery capacity.

  • Service 22DID E0F6
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 kWh
Unit
kWh

0x0005 = 5 → 510 = 0.5 kWh

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

State of health JOLIONHEV_BMS_PACK_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Service 22DID E0F5
  • Module78B → 7CB
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x62 = 98 → 98 %

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Climate

A/C pressure JOLIONHEV_AC_PRESSURE_HVAC

  • Service 22DID 1469
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×125010000−4096
Range
-4096 to 4095.875 kPa
Unit
kPa

In testing for 2021 to 2026.

A/C pressure, enhanced JOLIONHEV_AC_PRESSURE_HVAC2

  • Service 22DID 210C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×210
Range
-6553.6 to 6553.4 kPa
Unit
kPa

In testing for 2021 to 2026.

Cabin temperature, front JOLIONHEV_HVAC_CABIN_T_FRONTConfirmed

  • Service 22DID A019
  • Module763 → 7A3
  • Every5 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−30
Range
-30 to 655.15 °C
Unit
°C

0x01DB = 475 → 47510−30 = 17.5 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Evaporator temperature, front JOLIONHEV_HVAC_EVAPORATOR_T_FRONTConfirmed

  • Service 22DID A012
  • Module763 → 7A3
  • Every5 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−20
Range
-20 to 655.25 °C
Unit
°C

0x00CD = 205 → 20510−20 = 0.5 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Drivetrain

Engine net torque JOLIONHEV_TRANSMISSION_ENGINE_NET_TORQUE

  • Service 22DID 6915
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−510
Range
-510 to 65025 N·m
Unit
N·m

In testing for 2021 to 2026.

Engine torque JOLIONHEV_TRANSMISSION_ENGINE_TORQUE

  • Service 22DID 6915
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×4
Range
-512 to 508 N·m
Unit
N·m

In testing for 2021 to 2026.

Inverter temperature JOLIONHEV_MCU_TMCU_INVERTOR_TConfirmed

  • Service 22DID 2108
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

0x3A = 58 → 58−40 = 18 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor speed JOLIONHEV_MCU_TMCU_MOTOR_SPEEDConfirmed

  • Service 22DID 2110
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767 rpm
Unit
rpm

0x7F23 = 32547 → 32,547 rpm

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor speed, GMCU JOLIONHEV_MCU_GMCU_MOTOR_SPEEDConfirmed

  • Service 22DID 1110
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
0 to 32767 rpm
Unit
rpm

0x7FF7 = 32759 → 32,759 rpm

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor temperature JOLIONHEV_MCU_TMCU_MOTOR_T_1Confirmed

  • Service 22DID 2109
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor temperature, GMCU JOLIONHEV_MCU_GMCU_MOTOR_T_1Confirmed

  • Service 22DID 1109
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor winding temperature JOLIONHEV_MCU_TMCU_MOTOR_T_2Confirmed

  • Service 22DID 2111
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Motor winding temperature, GMCU JOLIONHEV_MCU_GMCU_MOTOR_T_2Confirmed

  • Service 22DID 1111
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

0x38 = 56 → 56−40 = 16 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Torque maximum, GMCU JOLIONHEV_MCU_GMCU_TORQUE_MAXConfirmed

  • Service 22DID 2304
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

0x0000 = 0 → 0 N·m

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Torque minimum, GMCU JOLIONHEV_MCU_GMCU_TORQUE_MINConfirmed

  • Service 22DID 2305
  • Module787 → 7C7
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val−1023
Range
0 to 64512 N·m
Unit
N·m

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Engine

Boost pressure JOLIONHEV_BOOST_PRESSURE_VALUE

  • Service 22DID 016A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

In testing for 2021 to 2026.

Boost pressure, actual JOLIONHEV_BOOST_PRESSURE_ACTUALConfirmed

  • Service 22DID 010F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x26E0 = 9952 → 9952128 = 77.75 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Boost pressure, target JOLIONHEV_BOOST_PRESSURE_TARGETConfirmed

  • Service 22DID 0112
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x0000 = 0 → 0128 = 0 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Injection pulse width JOLIONHEV_INJECTION_PULSE_WIDTH

  • Service 22DID 016D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 ms
Unit
ms

In testing for 2021 to 2026.

Knock counter JOLIONHEV_KNOCK_COUNTER

  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Knock retard JOLIONHEV_KNOCK_RETARD

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×8.82100
Range
0 to 22.491 °
Unit
°

In testing for 2021 to 2026.

Knock retard, cylinder 1 JOLIONHEV_KNOCK_RETARD_CYL_1Confirmed

  • Service 22DID 0170
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×34 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 2 JOLIONHEV_KNOCK_RETARD_CYL_2Confirmed

  • Service 22DID 0171
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×34 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 3 JOLIONHEV_KNOCK_RETARD_CYL_3Confirmed

  • Service 22DID 0172
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×34 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock retard, cylinder 4 JOLIONHEV_KNOCK_RETARD_CYL_4Confirmed

  • Service 22DID 0173
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×34
Range
-96 to 95.25 °
Unit
°

0x00 = 0 → 0×34 = 0 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 1 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_1Confirmed

  • Service 22DID 0174
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 2 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_2Confirmed

  • Service 22DID 0175
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 3 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_3Confirmed

  • Service 22DID 0176
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Knock sensor voltage, cylinder 4 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_4Confirmed

  • Service 22DID 0177
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfire current, total JOLIONHEV_MISFIRE_CURRENT_TOTAL

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256
Range
0 to 65280
Unit
Number

In testing for 2021 to 2026.

Oil pressure JOLIONHEV_OIL_PRESSURE

  • Service 22DID FD19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×156.2510000
Range
0 to 1023.984375 kPa
Unit
kPa

In testing for 2021 to 2026.

Oil temperature JOLIONHEV_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1602
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Oil temperature JOLIONHEV_OIL_TConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 0107
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023437−273.15
Range
-273.15 to 1262.793795 °C
Unit
°C

0x0B3A = 2874 → 2874×0.023437−273.15 = -205.792062 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet pressure JOLIONHEV_TURBOCHARGER_INLET_PRESSUREConfirmed

  • Service 22DID 0113
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.9921875 kPa
Unit
kPa

0x26F2 = 9970 → 9970128 = 77.890625 kPa

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Turbocharger inlet temperature JOLIONHEV_TURBOCHARGER_INLET_TConfirmed

  • Service 22DID 0114
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.023437−273.15
Range
-273.15 to 1262.793795 °C
Unit
°C

0x3000 = 12288 → 12288×0.023437−273.15 = 14.843856 °C

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Valve timing opening, intake, actual JOLIONHEV_INTAKE_VVT_ACTUALConfirmed

  • Service 22DID 0152
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15610000
Range
-511.1808 to 511.1652 °
Unit
°

0x060B = 1547 → 1547×15610000 = 24.1332 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Valve timing opening, intake, target JOLIONHEV_INTAKE_VVT_TARGETConfirmed

  • Service 22DID 0154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×7810000
Range
-255.5 to 255.5 °
Unit
°

0x0611 = 1553 → 1553×7810000 = 12.1134 °

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Variable clutch pressure control, min oil temperature JOLIONHEV_OT_VCPC_MIN

  • Service 22DID 1603
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2026.

Misfires

Misfire current cylinder 1 JOLIONHEV_MISFIRE_CURRENT_CYL_1

  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 2 JOLIONHEV_MISFIRE_CURRENT_CYL_2

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 3 JOLIONHEV_MISFIRE_CURRENT_CYL_3

  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire current cylinder 4 JOLIONHEV_MISFIRE_CURRENT_CYL_4

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 1 JOLIONHEV_MISFIRE_HISTORY_CYL_1

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 2 JOLIONHEV_MISFIRE_HISTORY_CYL_2

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 3 JOLIONHEV_MISFIRE_HISTORY_CYL_3

  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfire history cylinder 4 JOLIONHEV_MISFIRE_HISTORY_CYL_4

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Misfires, cylinder 1 JOLIONHEV_MISFIRES_CYL_1Confirmed

  • Service 22DID 0180
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 2 JOLIONHEV_MISFIRES_CYL_2Confirmed

  • Service 22DID 0183
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 3 JOLIONHEV_MISFIRES_CYL_3Confirmed

  • Service 22DID 0181
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, cylinder 4 JOLIONHEV_MISFIRES_CYL_4Confirmed

  • Service 22DID 0182
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Misfires, total count JOLIONHEV_MISFIRES_TOTALConfirmed

  • Service 22DID 017F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Fuel

Fuel flow JOLIONHEV_FUEL_FLOW

  • Service 22DID 0111
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.00429156
Range
0 to 281.2473846 L
Unit
L

In testing for 2021 to 2026.

Fuel level JOLIONHEV_FUEL_LEVEL_INPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Fuel level, liters JOLIONHEV_FUEL_LEVEL_LITERS

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 0106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 L
Unit
L

In testing for 2021 to 2026.

Fuel level, output JOLIONHEV_FUEL_LEVEL_OUTPUT

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 12C5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

Movement

Transmission electric pump speed JOLIONHEV_TRANSMISSION_ELECTRIC_PUMP_SPEED

  • Service 22DID 6A1A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission even axis speed JOLIONHEV_TRANSMISSION_EVEN_AXIS_SPEED

  • Service 22DID 6903
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission input shaft speed JOLIONHEV_TRANSMISSION_INPUT_SHAFT_SPEED

  • Service 22DID 690D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission odd axis speed JOLIONHEV_TRANSMISSION_ODD_AXIS_SPEED

  • Service 22DID 6902
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

In testing for 2021 to 2026.

Transmission

Clutch 1 pressure JOLIONHEV_TRANSMISSION_CLUTCH_1_PRESSURE

  • Service 22DID 690B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−200
Range
-200 to 6353.5 kPa
Unit
kPa

In testing for 2021 to 2026.

Clutch 1 torque JOLIONHEV_TRANSMISSION_CLUTCH_1_TORQUE

  • Service 22DID 6932
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch 2 pressure JOLIONHEV_TRANSMISSION_CLUTCH_2_PRESSURE

  • Service 22DID 690C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−200
Range
-200 to 6353.5 kPa
Unit
kPa

In testing for 2021 to 2026.

Clutch 2 torque JOLIONHEV_TRANSMISSION_CLUTCH_2_TORQUE

  • Service 22DID 6933
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16
Range
0 to 4080 N·m
Unit
N·m

In testing for 2021 to 2026.

Clutch temperature JOLIONHEV_TRANSMISSION_CLUTCH_TEMP

  • Service 22DID 6934
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−55
Range
-55 to 965 °C
Unit
°C

In testing for 2021 to 2026.

Clutch temperature v2 JOLIONHEV_TRANSMISSION_CLUTCH_TEMP_V1

  • Service 22DID 6A0A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4−55
Range
-55 to 965 °C
Unit
°C

In testing for 2021 to 2026.

Current gear JOLIONHEV_TRANSMISSION_CURRENT_GEAR

  • Service 22DID 6925
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Even clutch actual pressure JOLIONHEV_TRANSMISSION_EVEN_CLUTCH_ACTUAL_PRESSURE

  • Service 22DID 690C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val−2000
Range
-2000 to 63535 kPa
Unit
kPa

In testing for 2021 to 2026.

Even clutch requested pressure JOLIONHEV_TRANSMISSION_EVEN_CLUTCH_REQUESTED_PRESSURE

  • Service 22DID 69BD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2021 to 2026.

Gear position JOLIONHEV_GEARConfirmed

  • Service 22DID 0132
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2023, 2025 to 2026

Example reply from a 2024 Haval Jolion HEV.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.

Odd clutch actual pressure JOLIONHEV_TRANSMISSION_ODD_CLUTCH_ACTUAL_PRESSURE

  • Service 22DID 690B
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val−2000
Range
-2000 to 63535 kPa
Unit
kPa

In testing for 2021 to 2026.

Odd clutch requested pressure JOLIONHEV_TRANSMISSION_ODD_CLUTCH_REQUESTED_PRESSURE

  • Service 22DID 69BC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2021 to 2026.

Target gear JOLIONHEV_TRANSMISSION_TARGET_GEAR

  • Service 22DID 6926
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Transmission fluid temperature JOLIONHEV_TFT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID D126
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2021 to 2026.

Transmission temperature, pan JOLIONHEV_TFT_PAN

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 6A0A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val−55
Range
-55 to 65480 °C
Unit
°C

In testing for 2021 to 2026.

Trips

Odometer, engine JOLIONHEV_ODO_ENG

Pelican can show this parameter as the odometer.

  • Service 22DID 121E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2026.

Transmission odometer JOLIONHEV_ODO_TRANS

Pelican can show this parameter as the odometer.

  • Service 22DID 6901
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 km
Unit
km

In testing for 2021 to 2026.

Vehicle odometer JOLIONHEV_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID 00A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2021 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.