Parameters
The Haval Jolion HEV has 103 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accumulated charge, pack, counter 1 JOLIONHEV_BMS_PACK_ACCUMULATED_CHARGE_1Confirmed
- Service 22
DID E15B - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x0000B0D7 = 45271 → = 4,527.1 Ah
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Accumulated charge, pack, counter 2 JOLIONHEV_BMS_PACK_ACCUMULATED_CHARGE_2Confirmed
- Service 22
DID E15C - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
0x0000B017 = 45079 → = 4,507.9 Ah
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Battery current, bus JOLIONHEV_BMS_BUS_CURRENTConfirmed
- Service 22
DID E0A4 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1200 to 11907 A
- Unit
- A
0x1741 = 5953 → = -9.4 A
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Battery voltage JOLIONHEV_BATTERY_VOLTAGE
- Service 22
DID 1702 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 31.875 V
- Unit
- V
In testing for 2021 to 2026.
Cell position, maximum voltage JOLIONHEV_BMS_MAX_CELL_VOLTAGE_POSITIONConfirmed
- Service 22
DID E00A - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 1 to 256
- Unit
- Number
0x00 = 0 → = 1
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell position, minimum voltage JOLIONHEV_BMS_MIN_CELL_VOLTAGE_POSITIONConfirmed
- Service 22
DID E00B - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 1 to 256
- Unit
- Number
0x0F = 15 → = 16
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell state of charge, maximum JOLIONHEV_BMS_MAX_CELL_SOCConfirmed
- Service 22
DID E0F1 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x01F5 = 501 → = 50.1 %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell state of charge, minimum JOLIONHEV_BMS_MIN_CELL_SOCConfirmed
- Service 22
DID E0F2 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x01E1 = 481 → = 48.1 %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell voltage, maximum JOLIONHEV_BMS_CELL_VOLTAGE_MAXConfirmed
- Service 22
DID E008 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
0x0E48 = 3656 → 3,656 mV
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell voltage, minimum JOLIONHEV_BMS_CELL_VOLTAGE_MINConfirmed
- Service 22
DID E009 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mV
- Unit
- mV
0x0E3D = 3645 → 3,645 mV
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Cell voltages, total JOLIONHEV_BMS_TOTAL_CELL_VOLTAGESConfirmed
- Service 22
DID E007 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 1 to 65536 V
- Unit
- V
0x014F = 335 → = 336 V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Coolant inlet temperature, pack JOLIONHEV_BMS_PACK_LOOP_INLET_TConfirmed
- Service 22
DID E0E4 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x39 = 57 → = 17 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Discharge current limit, pack JOLIONHEV_BMS_PACK_DISCHARGE_CURRENT_LIMITConfirmed
- Service 22
DID E0C6 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1200 to 11907 A
- Unit
- A
0x1D0C = 7436 → = 287.2 A
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Discharge power limit, pack, 2 seconds JOLIONHEV_BMS_PACK_2S_DISCHARGE_POWER_LIMITConfirmed
- Service 22
DID E13D - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kW
- Unit
- kW
0x0199 = 409 → = 81.8 kW
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Discharge power limit, pack, 10 seconds JOLIONHEV_BMS_PACK_10S_DISCHARGE_POWER_LIMITConfirmed
- Service 22
DID E13E - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kW
- Unit
- kW
0x012B = 299 → = 59.8 kW
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
HV battery voltage JOLIONHEV_BMS_PACK_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID E006 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
0x0D1F = 3359 → = 335.9 V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Module temperature, average JOLIONHEV_BMS_MODULE_T_AVERAGEConfirmed
- Service 22
DID E0A1 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x39 = 57 → = 17 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Module temperature, maximum JOLIONHEV_BMS_MODULE_T_MAXIMUMConfirmed
- Service 22
DID E088 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x3A = 58 → = 18 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Module temperature, minimum JOLIONHEV_BMS_MODULE_T_MINIMUMConfirmed
- Service 22
DID E089 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x39 = 57 → = 17 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Recharge current limit, pack JOLIONHEV_BMS_PACK_RECHARGE_CURRENT_LIMITConfirmed
- Service 22
DID E0C8 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1200 to 11907 A
- Unit
- A
0x13E1 = 5089 → = -182.2 A
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Recharge power limit, pack, 2 seconds JOLIONHEV_BMS_PACK_2S_RECHARGE_POWER_LIMITConfirmed
- Service 22
DID E13F - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kW
- Unit
- kW
0x00CD = 205 → = 41 kW
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Recharge power limit, pack, 10 seconds JOLIONHEV_BMS_PACK_10S_RECHARGE_POWER_LIMITConfirmed
- Service 22
DID E140 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 kW
- Unit
- kW
0x00AD = 173 → = 34.6 kW
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Sleep duration, last JOLIONHEV_BMS_LAST_SLEEP_DURATIONConfirmed
- Service 22
DID E0DD - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 s
- Unit
- s
0x0000055F = 1375 → 1,375 s
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
State of charge JOLIONHEV_BMS_BATT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Service 22
DID E0F4 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x01E9 = 489 → = 48.9 %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
State of energy JOLIONHEV_BMS_PACK_SOEConfirmed
Pelican can show this parameter as the traction battery capacity.
- Service 22
DID E0F6 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kWh
- Unit
- kWh
0x0005 = 5 → = 0.5 kWh
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
State of health JOLIONHEV_BMS_PACK_SOHConfirmed
Pelican can show this parameter as the state of health.
- Service 22
DID E0F5 - Module
78B → 7CB - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x62 = 98 → 98 %
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Climate
A/C pressure JOLIONHEV_AC_PRESSURE_HVAC
- Service 22
DID 1469 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -4096 to 4095.875 kPa
- Unit
- kPa
In testing for 2021 to 2026.
A/C pressure, enhanced JOLIONHEV_AC_PRESSURE_HVAC2
- Service 22
DID 210C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Cabin temperature, front JOLIONHEV_HVAC_CABIN_T_FRONTConfirmed
- Service 22
DID A019 - Module
763 → 7A3 - Every
5 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -30 to 655.15 °C
- Unit
- °C
0x01DB = 475 → = 17.5 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Evaporator temperature, front JOLIONHEV_HVAC_EVAPORATOR_T_FRONTConfirmed
- Service 22
DID A012 - Module
763 → 7A3 - Every
5 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -20 to 655.25 °C
- Unit
- °C
0x00CD = 205 → = 0.5 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Drivetrain
Engine net torque JOLIONHEV_TRANSMISSION_ENGINE_NET_TORQUE
- Service 22
DID 6915 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -510 to 65025 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Engine torque JOLIONHEV_TRANSMISSION_ENGINE_TORQUE
- Service 22
DID 6915 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -512 to 508 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Inverter temperature JOLIONHEV_MCU_TMCU_INVERTOR_TConfirmed
- Service 22
DID 2108 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
0x3A = 58 → = 18 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor speed JOLIONHEV_MCU_TMCU_MOTOR_SPEEDConfirmed
- Service 22
DID 2110 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
0x7F23 = 32547 → 32,547 rpm
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor speed, GMCU JOLIONHEV_MCU_GMCU_MOTOR_SPEEDConfirmed
- Service 22
DID 1110 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 32767 rpm
- Unit
- rpm
0x7FF7 = 32759 → 32,759 rpm
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor temperature JOLIONHEV_MCU_TMCU_MOTOR_T_1Confirmed
- Service 22
DID 2109 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
0x38 = 56 → = 16 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor temperature, GMCU JOLIONHEV_MCU_GMCU_MOTOR_T_1Confirmed
- Service 22
DID 1109 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
0x38 = 56 → = 16 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor winding temperature JOLIONHEV_MCU_TMCU_MOTOR_T_2Confirmed
- Service 22
DID 2111 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
0x38 = 56 → = 16 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Motor winding temperature, GMCU JOLIONHEV_MCU_GMCU_MOTOR_T_2Confirmed
- Service 22
DID 1111 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
0x38 = 56 → = 16 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Torque maximum, GMCU JOLIONHEV_MCU_GMCU_TORQUE_MAXConfirmed
- Service 22
DID 2304 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
0x0000 = 0 → 0 N·m
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Torque minimum, GMCU JOLIONHEV_MCU_GMCU_TORQUE_MINConfirmed
- Service 22
DID 2305 - Module
787 → 7C7 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 64512 N·m
- Unit
- N·m
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Engine
Boost pressure JOLIONHEV_BOOST_PRESSURE_VALUE
- Service 22
DID 016A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Boost pressure, actual JOLIONHEV_BOOST_PRESSURE_ACTUALConfirmed
- Service 22
DID 010F - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x26E0 = 9952 → = 77.75 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Boost pressure, target JOLIONHEV_BOOST_PRESSURE_TARGETConfirmed
- Service 22
DID 0112 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Injection pulse width JOLIONHEV_INJECTION_PULSE_WIDTH
- Service 22
DID 016D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 ms
- Unit
- ms
In testing for 2021 to 2026.
Knock counter JOLIONHEV_KNOCK_COUNTER
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Knock retard JOLIONHEV_KNOCK_RETARD
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 22.491 °
- Unit
- °
In testing for 2021 to 2026.
Knock retard, cylinder 1 JOLIONHEV_KNOCK_RETARD_CYL_1Confirmed
- Service 22
DID 0170 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 2 JOLIONHEV_KNOCK_RETARD_CYL_2Confirmed
- Service 22
DID 0171 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 3 JOLIONHEV_KNOCK_RETARD_CYL_3Confirmed
- Service 22
DID 0172 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock retard, cylinder 4 JOLIONHEV_KNOCK_RETARD_CYL_4Confirmed
- Service 22
DID 0173 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
0x00 = 0 → = 0 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 1 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_1Confirmed
- Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 2 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_2Confirmed
- Service 22
DID 0175 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 3 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_3Confirmed
- Service 22
DID 0176 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Knock sensor voltage, cylinder 4 JOLIONHEV_KNOCK_SENSOR_VOLTAGE_CYL_4Confirmed
- Service 22
DID 0177 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfire current, total JOLIONHEV_MISFIRE_CURRENT_TOTAL
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 65280
- Unit
- Number
In testing for 2021 to 2026.
Oil pressure JOLIONHEV_OIL_PRESSURE
- Service 22
DID FD19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1023.984375 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Oil temperature JOLIONHEV_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1602 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Oil temperature JOLIONHEV_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 0107 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
0x0B3A = 2874 → = -205.792062 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet pressure JOLIONHEV_TURBOCHARGER_INLET_PRESSUREConfirmed
- Service 22
DID 0113 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.9921875 kPa
- Unit
- kPa
0x26F2 = 9970 → = 77.890625 kPa
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Turbocharger inlet temperature JOLIONHEV_TURBOCHARGER_INLET_TConfirmed
- Service 22
DID 0114 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793795 °C
- Unit
- °C
0x3000 = 12288 → = 14.843856 °C
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Valve timing opening, intake, actual JOLIONHEV_INTAKE_VVT_ACTUALConfirmed
- Service 22
DID 0152 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511.1808 to 511.1652 °
- Unit
- °
0x060B = 1547 → = 24.1332 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Valve timing opening, intake, target JOLIONHEV_INTAKE_VVT_TARGETConfirmed
- Service 22
DID 0154 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255.5 to 255.5 °
- Unit
- °
0x0611 = 1553 → = 12.1134 °
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Variable clutch pressure control, min oil temperature JOLIONHEV_OT_VCPC_MIN
- Service 22
DID 1603 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Misfires
Misfire current cylinder 1 JOLIONHEV_MISFIRE_CURRENT_CYL_1
- Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 2 JOLIONHEV_MISFIRE_CURRENT_CYL_2
- Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 3 JOLIONHEV_MISFIRE_CURRENT_CYL_3
- Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire current cylinder 4 JOLIONHEV_MISFIRE_CURRENT_CYL_4
- Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 1 JOLIONHEV_MISFIRE_HISTORY_CYL_1
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 2 JOLIONHEV_MISFIRE_HISTORY_CYL_2
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 3 JOLIONHEV_MISFIRE_HISTORY_CYL_3
- Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire history cylinder 4 JOLIONHEV_MISFIRE_HISTORY_CYL_4
- Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfires, cylinder 1 JOLIONHEV_MISFIRES_CYL_1Confirmed
- Service 22
DID 0180 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 2 JOLIONHEV_MISFIRES_CYL_2Confirmed
- Service 22
DID 0183 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 3 JOLIONHEV_MISFIRES_CYL_3Confirmed
- Service 22
DID 0181 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, cylinder 4 JOLIONHEV_MISFIRES_CYL_4Confirmed
- Service 22
DID 0182 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Misfires, total count JOLIONHEV_MISFIRES_TOTALConfirmed
- Service 22
DID 017F - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0000 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Fuel
Fuel flow JOLIONHEV_FUEL_FLOW
- Service 22
DID 0111 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 281.2473846 L
- Unit
- L
In testing for 2021 to 2026.
Fuel level JOLIONHEV_FUEL_LEVEL_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 002F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Fuel level, liters JOLIONHEV_FUEL_LEVEL_LITERS
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 0106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2021 to 2026.
Fuel level, output JOLIONHEV_FUEL_LEVEL_OUTPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 12C5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Movement
Transmission electric pump speed JOLIONHEV_TRANSMISSION_ELECTRIC_PUMP_SPEED
- Service 22
DID 6A1A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Transmission even axis speed JOLIONHEV_TRANSMISSION_EVEN_AXIS_SPEED
- Service 22
DID 6903 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Transmission input shaft speed JOLIONHEV_TRANSMISSION_INPUT_SHAFT_SPEED
- Service 22
DID 690D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Transmission odd axis speed JOLIONHEV_TRANSMISSION_ODD_AXIS_SPEED
- Service 22
DID 6902 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2021 to 2026.
Transmission
Clutch 1 pressure JOLIONHEV_TRANSMISSION_CLUTCH_1_PRESSURE
- Service 22
DID 690B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 6353.5 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Clutch 1 torque JOLIONHEV_TRANSMISSION_CLUTCH_1_TORQUE
- Service 22
DID 6932 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4080 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Clutch 2 pressure JOLIONHEV_TRANSMISSION_CLUTCH_2_PRESSURE
- Service 22
DID 690C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 6353.5 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Clutch 2 torque JOLIONHEV_TRANSMISSION_CLUTCH_2_TORQUE
- Service 22
DID 6933 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 4080 N·m
- Unit
- N·m
In testing for 2021 to 2026.
Clutch temperature JOLIONHEV_TRANSMISSION_CLUTCH_TEMP
- Service 22
DID 6934 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 965 °C
- Unit
- °C
In testing for 2021 to 2026.
Clutch temperature v2 JOLIONHEV_TRANSMISSION_CLUTCH_TEMP_V1
- Service 22
DID 6A0A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 965 °C
- Unit
- °C
In testing for 2021 to 2026.
Current gear JOLIONHEV_TRANSMISSION_CURRENT_GEAR
- Service 22
DID 6925 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Even clutch actual pressure JOLIONHEV_TRANSMISSION_EVEN_CLUTCH_ACTUAL_PRESSURE
- Service 22
DID 690C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -2000 to 63535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Even clutch requested pressure JOLIONHEV_TRANSMISSION_EVEN_CLUTCH_REQUESTED_PRESSURE
- Service 22
DID 69BD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Gear position JOLIONHEV_GEARConfirmed
- Service 22
DID 0132 - Module
7E0 → 7E8 - Every
1 s - Testing for 2021 to 2023, 2025 to 2026
Example reply from a 2024 Haval Jolion HEV.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 2021 to 2023, 2025 to 2026.
Odd clutch actual pressure JOLIONHEV_TRANSMISSION_ODD_CLUTCH_ACTUAL_PRESSURE
- Service 22
DID 690B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -2000 to 63535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Odd clutch requested pressure JOLIONHEV_TRANSMISSION_ODD_CLUTCH_REQUESTED_PRESSURE
- Service 22
DID 69BC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Target gear JOLIONHEV_TRANSMISSION_TARGET_GEAR
- Service 22
DID 6926 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Transmission fluid temperature JOLIONHEV_TFT
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID D126 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission temperature, pan JOLIONHEV_TFT_PAN
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 6A0A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -55 to 65480 °C
- Unit
- °C
In testing for 2021 to 2026.
Trips
Odometer, engine JOLIONHEV_ODO_ENG
Pelican can show this parameter as the odometer.
- Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2026.
Transmission odometer JOLIONHEV_ODO_TRANS
Pelican can show this parameter as the odometer.
- Service 22
DID 6901 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2026.
Vehicle odometer JOLIONHEV_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 00A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2021 to 2026.