GMC Sierra 3500HD

Parameters

The GMC Sierra 3500HD has 170 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Vehicle speed SIERRA3500_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 000D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2013, 2015 to 2018

Example reply from a 2014 GMC Sierra 3500HD.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014. In testing for 2007 to 2013, 2015 to 2018. Supported for 2021. Not supported for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Charge air cooler temperature sensor 1 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_1

  • Service 22DID 30AD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Charge air cooler temperature sensor 1 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_1_DA11

  • Service 22DID 30AD
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Charge air cooler temperature sensor 2 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_2

  • Service 22DID 30AE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Charge air cooler temperature sensor 2 SIERRA3500_CHARGE_AIR_COOLER_T_SNS_2_DA11

  • Service 22DID 30AE
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Control module voltage SIERRA3500_M_CTRL_MODULE_V

  • Service 22DID 0042
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2007 to 2019.

Ignition 1 voltage SIERRA3500_IGN_1_V

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2007 to 2019.

Clocks

Time since engine start SIERRA3500_RUNTM

  • Service 22DID 11A1
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2014, 2024. Supported for 2020 to 2021.

Engine

1-2 shift error SIERRA3500_1_2_SHIFT_ERROR

  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

1-2 shift time SIERRA3500_1_2_SHIFT_TIME

  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

2-3 shift error SIERRA3500_2_3_SHIFT_ERROR

  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

2-3 shift time SIERRA3500_2_3_SHIFT_TIME

  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

3-4 shift error SIERRA3500_3_4_SHIFT_ERROR

  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

3-4 shift time SIERRA3500_3_4_SHIFT_TIME

  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

Air conditioning high side pressure SIERRA3500_AC_HIGH_SIDE_P

  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2.02
Range
0 to 515.1 psi
Unit
psi

In testing for 2007 to 2019.

Air filter life remaining SIERRA3500_AIRFILT_LIFE

  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Air/fuel ratio, commanded SIERRA3500_AIR_FUEL_RAT_CMD

  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 1 SIERRA3500_BALANCE_RATE_CYL_1

  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 2 SIERRA3500_BALANCE_RATE_CYL_2

  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 3 SIERRA3500_BALANCE_RATE_CYL_3

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 4 SIERRA3500_BALANCE_RATE_CYL_4

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 5 SIERRA3500_BALANCE_RATE_CYL_5

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 6 SIERRA3500_BALANCE_RATE_CYL_6

  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 7 SIERRA3500_BALANCE_RATE_CYL_7

  • Service 22DID 1635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Balance rate, cylinder 8 SIERRA3500_BALANCE_RATE_CYL_8

  • Service 22DID 1636
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2007 to 2019.

Barometric pressure, V8 SIERRA3500_BAROMETRIC_P_V8

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2007 to 2019.

Boost pressure: actual SIERRA3500_BP_ACT

  • Service 22DID 20E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 2007 to 2019.

Boost pressure: desired SIERRA3500_BP_DES

  • Service 22DID 328A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 2007 to 2019.

Boost pressure: desired SIERRA3500_BP_DES_DA11

  • Service 22DID 328A
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 2020 to 2026.

Calculated engine oil pressure SIERRA3500_EOP_CALC

  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2007 to 2019.

Calculated engine oil temperature SIERRA3500_EOT_CALC

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Cooling fan command SIERRA3500_COOLING_FAN_CMD

  • Service 22DID 3812
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Cooling fan motor command SIERRA3500_COOLING_FAN_MOTOR_CMD

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Diesel particulate filter, average filter inlet temperature during regeneration SIERRA3500_DPF_AVG_FLT_INLET_T_DURING_REGEN

  • Service 22DID 20F8
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 s
Unit
s

In testing for 2020 to 2026.

Diesel particulate filter, average regeneration duration SIERRA3500_DPF_AVG_REGEN_DURATION

  • Service 22DID 20F9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204065535
Range
0 to 2040 s
Unit
s

In testing for 2020 to 2026.

Diesel particulate filter, calculated flow resistance SIERRA3500_DPF_CALCULATED_FLOW_RESISTANCE_KPA_L_S

  • Service 22DID 20F5
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val100
Range
0 to 2.55
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter, corrected pressure SIERRA3500_DPF_CORRECTED_PRES

  • Service 22DID 34D9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
-327.68 to 327.67 kPa
Unit
kPa

In testing for 2020 to 2026.

Diesel particulate filter, engine run time since last regeneration SIERRA3500_DPF_ENGINE_RUN_TIME_SINCE_LAST_REGEN_MIN

  • Service 22DID 20F3
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×860
Range
0 to 8738 min
Unit
min

In testing for 2020 to 2026.

Diesel particulate filter, exhaust gas temperature 1 SIERRA3500_DPF_EGT_1

  • Service 22DID 303A
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter, exhaust gas temperature 2 SIERRA3500_DPF_EGT_2

  • Service 22DID 303B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter, exhaust gas temperature 3 SIERRA3500_DPF_EGT_3

  • Service 22DID 30A9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter, exhaust gas temperature 4 SIERRA3500_DPF_EGT_4

  • Service 22DID 0078
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter, exhaust gas temperature 5 SIERRA3500_DPF_EGT_5

  • Service 22DID 30AB
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2020 to 2026.

Diesel particulate filter, number of completed regeneration events SIERRA3500_DPF_NUMBER_OF_COMPLETED_REGENS

  • Service 22DID 304B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter, pressure sensor SIERRA3500_DPF_PRES_SNS

  • Service 22DID 3035
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Diesel particulate filter, regeneration reason SIERRA3500_DPF_REGEN_REASON

  • Service 22DID 303E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Diesel particulate filter, regeneration status SIERRA3500_DPF_REGEN_STS

  • Service 22DID 3375
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine oil absolute pressure SIERRA3500_EOP_ABS

  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2007 to 2019.

Engine oil life remaining SIERRA3500_EO_LIFE_REMAINING

  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Engine oil pressure SIERRA3500_EOP

  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2007 to 2019.

Engine oil pressure SIERRA3500_EOP_DA11

  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2007 to 2019.

Engine oil pressure SIERRA3500_EOP_DA11_2

  • Service 22DID 1470
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2020 to 2026.

Engine oil pressure 2 SIERRA3500_EOP_2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×35−21.6
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 2007 to 2019.

Engine oil pressure control solenoid valve command SIERRA3500_EOP_CTRL_SOLENOID_VALVE_CMD

  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2007 to 2019.

Engine oil pressure, desired SIERRA3500_EOP_DES

  • Service 22DID 37A7
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 kPa
Unit
kPa

In testing for 2020 to 2026.

Engine oil temperature SIERRA3500_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Engine oil temperature SIERRA3500_EOT_DA11

  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Engine oil temperature SIERRA3500_EOT_DA11_2_2

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Engine torque SIERRA3500_ENG_TQ

  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2007 to 2019.

Engine torque SIERRA3500_ENG_TQ_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 N·m
Unit
N·m

In testing for 2007 to 2019.

Evaporative emissions purge SIERRA3500_EVAPORATIVE

  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Exhaust gas recirculation duty cycle SIERRA3500_EGR_DUTY

  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Exhaust gas recirculation voltage SIERRA3500_EGR_V

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2007 to 2019.

Heated oxygen sensor SIERRA3500_HEATED_OXYGEN_SENS

  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 2007 to 2019.

Idle air control position SIERRA3500_IDLE_AIR_CTRL_POS

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Injector duty cycle bank 1 SIERRA3500_INJECTOR_DUTY_CYCLE_BANK_1

  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 2007 to 2019.

Injector duty cycle bank 2 SIERRA3500_INJECTOR_DUTY_CYCLE_BANK_2

  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 2007 to 2019.

Injector pulse width, cylinder 1 SIERRA3500_INJ_WIDTH_CYL_1

  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Injector pulse width, cylinder 7 SIERRA3500_INJ_WIDTH_CYL_7

  • Service 22DID 1199
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Injector pulse width, cylinder 8 SIERRA3500_INJ_WIDTH_CYL_8

  • Service 22DID 129A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Intake air temperature 2 SIERRA3500_IAT_2

  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Knock retard SIERRA3500_KNOCK_RETARD

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×22100
Range
0 to 56.1 °
Unit
°

In testing for 2007 to 2019.

Knock retard, alternate SIERRA3500_KNOCK_RETARD_ALT

  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2007 to 2019.

Knock sensor active counter SIERRA3500_KNOCK_SENS_ACTIVE

  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Last shift time SIERRA3500_LAST_SHIFT_TIME

  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2007 to 2019.

Mass airflow sensor SIERRA3500_MAF

  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2007 to 2019.

Misfire current, cylinder 7 SIERRA3500_MIS_CURRENT_7

  • Service 22DID 11EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfire current, cylinder 8 SIERRA3500_MIS_CURRENT_8

  • Service 22DID 11ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 1 SIERRA3500_MIS_HISTORY_1

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 2 SIERRA3500_MIS_HISTORY_2

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 3 SIERRA3500_MIS_HISTORY_3

  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 4 SIERRA3500_MIS_HISTORY_4

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 5 SIERRA3500_MIS_HISTORY_5

  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 6 SIERRA3500_MIS_HISTORY_6

  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 7 SIERRA3500_MIS_HISTORY_7

  • Service 22DID 11FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfire history, cylinder 8 SIERRA3500_MIS_HISTORY_8

  • Service 22DID 11FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 1 SIERRA3500_MISFIRES_C1_CUR

  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 2 SIERRA3500_MISFIRES_C2_CUR

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 3 SIERRA3500_MISFIRES_C3_CUR

  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 4 SIERRA3500_MISFIRES_C4_CUR

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 5 SIERRA3500_MISFIRES_C5_CUR

  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 6 SIERRA3500_MISFIRES_C6_CUR

  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Misfires, current, cylinder 7 SIERRA3500_MISFIRES_C7_CUR

  • Service 22DID 11EC
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Misfires, current, cylinder 8 SIERRA3500_MISFIRES_C8_CUR

  • Service 22DID 11ED
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Outside air temperature SIERRA3500_AAT

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Particulate matter sensor soot accumulation SIERRA3500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION

  • Service 22DID 3635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Particulate matter sensor soot accumulation SIERRA3500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION_DA11

  • Service 22DID 3635
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Particulate matter sensor temperature SIERRA3500_PARTICULATE_MATTER_SNS_T

  • Service 22DID 3372
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 °C
Unit
°C

In testing for 2007 to 2019.

Particulate matter sensor temperature SIERRA3500_PARTICULATE_MATTER_SNS_T_DA11

  • Service 22DID 3372
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 °C
Unit
°C

In testing for 2020 to 2026.

Pressure control solenoid current, actual SIERRA3500_P_CTRL_SOLENOID_ACT

  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2019.

Pressure control solenoid current, reference SIERRA3500_P_CTRL_SOLENOID

  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2007 to 2019.

Remaining oil life SIERRA3500_REMAINING_OIL_LIFE

  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2007 to 2019.

Total knock retard SIERRA3500_TOTAL_KNOCK_RETARD

  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45100
Range
0 to 114.75 °
Unit
°

In testing for 2007 to 2019.

Total misfire SIERRA3500_TOTAL_MISFIRE

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Transmission fluid temperature SIERRA3500_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Transmission fluid temperature, variant 1 SIERRA3500_ATF_T_VAR_1

  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Transmission fluid temperature, variant 6 SIERRA3500_ATF_T_VAR_6

  • Service 22DID 280D
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Fuel

Ethanol content of fuel SIERRA3500_ETHANOL_CONTENT_FUEL

  • Service 22DID 0052
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Fuel consumption rate SIERRA3500_FUEL_RATE

  • Service 22DID 005E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50010000
Range
0 to 3276.75 L
Unit
L

In testing for 2007 to 2019.

Fuel injection, cylinder 1 SIERRA3500_FUEL_INJECTION_C1

  • Service 22DID 20AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 1 SIERRA3500_FUEL_INJECTION_C1_DA11

  • Service 22DID 20AC
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 2 SIERRA3500_FUEL_INJ_CYL_2

  • Service 22DID 20AD
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 2 SIERRA3500_FUEL_INJECTION_C2

  • Service 22DID 1194
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 2 SIERRA3500_FUEL_INJECTION_C2_DA11

  • Service 22DID 1194
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 3 SIERRA3500_FUEL_INJ_CYL_3

  • Service 22DID 20AE
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 3 SIERRA3500_FUEL_INJECTION_C3

  • Service 22DID 1195
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 3 SIERRA3500_FUEL_INJECTION_C3_DA11

  • Service 22DID 1195
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 4 SIERRA3500_FUEL_INJ_CYL_4

  • Service 22DID 20AF
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 4 SIERRA3500_FUEL_INJECTION_C4

  • Service 22DID 1196
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 4 SIERRA3500_FUEL_INJECTION_C4_DA11

  • Service 22DID 1196
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 5 SIERRA3500_FUEL_INJ_CYL_5

  • Service 22DID 20B0
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 5 SIERRA3500_FUEL_INJECTION_C5

  • Service 22DID 1197
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 5 SIERRA3500_FUEL_INJECTION_C5_DA11

  • Service 22DID 1197
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 6 SIERRA3500_FUEL_INJ_CYL_6

  • Service 22DID 20B1
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.55 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 6 SIERRA3500_FUEL_INJECTION_C6

  • Service 22DID 1198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 6 SIERRA3500_FUEL_INJECTION_C6_DA11

  • Service 22DID 1198
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 7 SIERRA3500_FUEL_INJECTION_C7

  • Service 22DID 1199
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2020 to 2026.

Fuel injection, cylinder 8 SIERRA3500_FUEL_INJECTION_C8

  • Service 22DID 20B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2007 to 2019.

Fuel injection, cylinder 8 SIERRA3500_FUEL_INJECTION_C8_DA11

  • Service 22DID 20B3
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2020 to 2026.

Fuel remaining SIERRA3500_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2007 to 2019.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2024. Supported for 2020 to 2021.

Fuel tank pressure SIERRA3500_FUEL_TANK_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val33333.33333
Range
0 to 1.96 psi
Unit
psi

In testing for 2007 to 2019.

Fuel temperature SIERRA3500_FUEL_T

  • Service 22DID 3218
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 2007 to 2019.

Fuel temperature SIERRA3500_FUEL_T_DA11

  • Service 22DID 3218
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 2020 to 2026.

Total fuel consumption rate SIERRA3500_TOTAL_FUEL_CONSUMPTION_RATE

  • Service 22DID 009D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2007 to 2019.

Total fuel consumption rate SIERRA3500_TOTAL_FUEL_CONSUMPTION_RATE_DA11

  • Service 22DID 009D
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2020 to 2026.

Movement

Desired idle speed SIERRA3500_DES_IDLE_SPD

  • Service 22DID 1192
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5
Range
0 to 3187.5 rpm
Unit
rpm

In testing for 2007 to 2019.

Torque converter clutch slip speed SIERRA3500_TC_SLIP_VSS

  • Service 22DID 1991
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2007 to 2019.

Torque converter clutch slip speed SIERRA3500_TC_SLIP_VSS_DA18

  • Service 22DID 1991
  • ModuleDA18 → 2AF118
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2020 to 2026.

Torque converter clutch slip speed SIERRA3500_TQ_CONV_CLU_SLIP_SPD

  • Service 22DID 1991
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2007 to 2019.

Vehicle speed SIERRA3500_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID 000D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2007 to 2013, 2015 to 2018

Example reply from a 2014 GMC Sierra 3500HD.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2014. In testing for 2007 to 2013, 2015 to 2018. Supported for 2021. Not supported for 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024. Supported for 2014, 2020 to 2021.

Tires

Front left tire pressure SIERRA3500_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 5005
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2007 to 2019.

Front left tire pressure SIERRA3500_TP_FL_DA40

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 5005
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2026.

Front left tire sensor ID SIERRA3500_TID_FL

  • Service 22DID 4005
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2007 to 2019.

Front left tire sensor ID SIERRA3500_TID_FL_DA40

  • Service 22DID 4005
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Front right tire pressure SIERRA3500_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 5006
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2007 to 2019.

Front right tire pressure SIERRA3500_TP_FR_DA40

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 5006
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2026.

Front right tire sensor ID SIERRA3500_TID_FR

  • Service 22DID 4006
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2007 to 2019.

Front right tire sensor ID SIERRA3500_TID_FR_DA40

  • Service 22DID 4006
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Rear left tire pressure SIERRA3500_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 5008
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2007 to 2019.

Rear left tire pressure SIERRA3500_TP_RL_DA40

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 5008
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2026.

Rear left tire sensor ID SIERRA3500_TID_RL

  • Service 22DID 4008
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2007 to 2019.

Rear left tire sensor ID SIERRA3500_TID_RL_DA40

  • Service 22DID 4008
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Rear right tire pressure SIERRA3500_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 5007
  • Module241 → 641
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2007 to 2019.

Rear right tire pressure SIERRA3500_TP_RR_DA40

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 5007
  • ModuleDA40 → 40
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2020 to 2026.

Rear right tire sensor ID SIERRA3500_TID_RR

  • Service 22DID 4007
  • Module241 → 641
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2007 to 2019.

Rear right tire sensor ID SIERRA3500_TID_RR_DA40

  • Service 22DID 4007
  • ModuleDA40 → 40
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Hexadecimal

In testing for 2020 to 2026.

Transmission

Clutch slip, AT C1, ring SIERRA3500_CLU_SLIP_C1_RING

  • Service 22DID 2851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2007 to 2019.

Clutch slip, AT C3, ring SIERRA3500_CLU_SLIP_C3_RING

  • Service 22DID 19D4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2007 to 2019.

Current gear SIERRA3500_CURRENT_GEAR

  • Service 22DID 1B30
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−3
Range
-3 to 252
Unit
Number

In testing for 2007 to 2019.

Current gear SIERRA3500_CURRENT_GEAR_7E0

  • Service 22DID 199A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Current gear, variant 2 SIERRA3500_CURRENT_GEAR_VAR_2

  • Service 22DID 199A
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Current gear, variant 3 SIERRA3500_CURRENT_GEAR_VAR_3

  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2007 to 2019.

Transmission fluid temperature, filtered SIERRA3500_TF_T_FLTED

  • Service 22DID 295A
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2007 to 2019.

Transmission fluid temperature, filtered SIERRA3500_TF_T_FLTED_DA18

  • Service 22DID 295A
  • ModuleDA18 → 2AF118
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Transmission input shaft speed, 2 SIERRA3500_TRANS_ISS

  • Service 22DID 1941
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2007 to 2019.

Trips

Diesel particulate filter, average distance between regeneration events SIERRA3500_DPF_AVG_DIST_BETWEEN_REGENS

  • Service 22DID 20F7
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Diesel particulate filter, distance since last regeneration SIERRA3500_DPF_DIST_SINCE_LAST_REGEN

  • Service 22DID 3039
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Odometer ODOSAE J1979Confirmed

Pelican can show this parameter as the odometer.

  • Service 01PID A6
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.