Parameters
The GMC Sierra 2500HD has 246 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery voltage SIERRA2500_BAT_VConfirmed
- Service 22
DID 002F - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
0x00 = 0 → = 0 V
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Charge air cooler temperature sensor 1 SIERRA2500_CHARGE_AIR_COOLER_T_SNS_1
- Service 22
DID 30AD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Charge air cooler temperature sensor 1 SIERRA2500_CHG_AIR_COOLER_T_1Confirmed
- Service 22
DID 30AD - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x37 = 55 → = 15 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Charge air cooler temperature sensor 2 SIERRA2500_CHARGE_AIR_COOLER_T_SNS_2
- Service 22
DID 30AE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Charge air cooler temperature sensor 2 SIERRA2500_CHG_AIR_COOLER_T_2Confirmed
- Service 22
DID 30AE - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x2E = 46 → = 6 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Control module voltage SIERRA2500_M_CTRL_MODULE_V
- Service 22
DID 0042 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2001 to 2019. Not supported for 2024.
Ignition 1 voltage SIERRA2500_IGN_1_V
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2001 to 2019. Not supported for 2024.
Climate
Ambient air temperature AATSAE J1979Confirmed
- Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2004, 2022, 2024.
Clocks
Time since engine start SIERRA2500_RUNTM
- Service 22
DID 11A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004.
Control
Steering wheel angle SIERRA2500_STEER_ANGLEConfirmed
- Service 22
DID 4C2D - Module
DA28 → 2AF128 - Every
100 ms - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.896 to 720.8739 °
- Unit
- °
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. Supported for 2004, 2022, 2024.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2025. Supported for 2004, 2022, 2024.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2025. Supported for 2004, 2022, 2024.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. Supported for 2004, 2022, 2024.
Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2025. Supported for 2004, 2022, 2024.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2025. Supported for 2004, 2022, 2024.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2025. Supported for 2004, 2022, 2024.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2004, 2022, 2024.
Engine
1-2 shift error SIERRA2500_1_2_SHIFT_ERROR
- Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
1-2 shift time SIERRA2500_1_2_SHIFT_TIME
- Service 22
DID 1993 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
2-3 shift error SIERRA2500_2_3_SHIFT_ERROR
- Service 22
DID 1998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
2-3 shift time SIERRA2500_2_3_SHIFT_TIME
- Service 22
DID 1994 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
3-4 shift error SIERRA2500_3_4_SHIFT_ERROR
- Service 22
DID 1999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
3-4 shift time SIERRA2500_3_4_SHIFT_TIME
- Service 22
DID 1995 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2024. Supported for 2022, 2025.
Air conditioning high side pressure SIERRA2500_AC_HIGH_SIDE_P
- Service 22
DID 1564 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 515.1 psi
- Unit
- psi
In testing for 2001 to 2019. Not supported for 2024.
Air filter life remaining SIERRA2500_AIR_FLT_LIFEConfirmed
- Service 22
DID 36A7 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
0x5A = 90 → 90 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Air filter life remaining SIERRA2500_AIRFILT_LIFE
- Service 22
DID 36A7 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Air/fuel ratio, commanded SIERRA2500_AIR_FUEL_RAT_CMD
- Service 22
DID 119E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 1 SIERRA2500_BALANCE_RATE_CYL_1
- Service 22
DID 162F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 2 SIERRA2500_BALANCE_RATE_CYL_2
- Service 22
DID 1630 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 3 SIERRA2500_BALANCE_RATE_CYL_3
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 4 SIERRA2500_BALANCE_RATE_CYL_4
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 5 SIERRA2500_BALANCE_RATE_CYL_5
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 6 SIERRA2500_BALANCE_RATE_CYL_6
- Service 22
DID 1634 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 7 SIERRA2500_BALANCE_RATE_CYL_7
- Service 22
DID 1635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Balance rate, cylinder 8 SIERRA2500_BALANCE_RATE_CYL_8
- Service 22
DID 1636 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -512 to 511
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Barometric pressure, V8 SIERRA2500_BAROMETRIC_P_V8
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Boost pressure, actual SIERRA2500_BOOST_P_ACTConfirmed
- Service 22
DID 20E3 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Boost pressure, desired SIERRA2500_BOOST_P_DESConfirmed
- Service 22
DID 328A - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 kPa
- Unit
- kPa
0x2648 = 9800 → = 98 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Boost pressure: actual SIERRA2500_BP_ACT
- Service 22
DID 20E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Boost pressure: desired SIERRA2500_BP_DES
- Service 22
DID 328A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Brake pressure, raw scale SIERRA2500_BPConfirmed
- Service 22
DID 4A7C - Module
DA28 → 2AF128 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -12800 to 12700 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Calculated engine oil pressure SIERRA2500_EOP_CALC
- Service 22
DID 1C1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Calculated engine oil temperature SIERRA2500_EOT_CALC
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2022.
Cooling fan command SIERRA2500_COOLING_FAN_CMD
- Service 22
DID 3812 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Cooling fan motor command SIERRA2500_COOLING_FAN_MOTOR_CMD
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Diesel particulate filter, average filter inlet temperature during regeneration SIERRA2500_DPF_AVG_FLT_INLET_T_DURING_REGENConfirmed
- Service 22
DID 20F8 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 s
- Unit
- s
0x0190 = 400 → = 0 s
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, calculated flow resistance SIERRA2500_DPF_CALCULATED_FLOW_RESISTANCE_KPA_L_SConfirmed
- Service 22
DID 20F5 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
0x00 = 0 → = 0
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, corrected pressure SIERRA2500_DPF_CORRECTED_PRESConfirmed
- Service 22
DID 34D9 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, engine run time since last regeneration SIERRA2500_DPF_ENGINE_RUN_TIME_SINCE_LAST_REGEN_MINConfirmed
- Service 22
DID 20F3 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8738 min
- Unit
- min
0x0000 = 0 → = 0 min
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, exhaust gas temperature 1 SIERRA2500_DPF_EGT_1Confirmed
- Service 22
DID 303A - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0349 = 841 → = 44.1 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, exhaust gas temperature 2 SIERRA2500_DPF_EGT_2Confirmed
- Service 22
DID 303B - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x02E2 = 738 → = 33.8 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, exhaust gas temperature 3 SIERRA2500_DPF_EGT_3Confirmed
- Service 22
DID 30A9 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x0235 = 565 → = 16.5 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, exhaust gas temperature 4 SIERRA2500_DPF_EGT_4Confirmed
- Service 22
DID 0078 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, exhaust gas temperature 5 SIERRA2500_DPF_EGT_5Confirmed
- Service 22
DID 30AB - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
0x01F2 = 498 → = 9.8 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, number of completed regeneration events SIERRA2500_DPF_NUMBER_OF_COMPLETED_REGENSConfirmed
- Service 22
DID 304B - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0012 = 18 → 18
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, pressure SIERRA2500_DPF_PRESConfirmed
- Service 22
DID 34D8 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
0x0000 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, regeneration reason SIERRA2500_DPF_REGEN_REASONConfirmed
- Service 22
DID 303E - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, regeneration status SIERRA2500_DPF_REGEN_STSConfirmed
- Service 22
DID 3375 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Engine oil absolute pressure SIERRA2500_EOP_ABS
- Service 22
DID 2344 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Engine oil absolute pressure sensor SIERRA2500_EOP_ABS_SENSConfirmed
- Service 22
DID 2344 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
0x15 = 21 → = 84 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine oil life remaining SIERRA2500_ENG_OIL_LIFEConfirmed
- Service 22
DID 4DC0 - Module
DA11 → 2AF111 - Every
30 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine oil life remaining SIERRA2500_EO_LIFE_REMAINING
- Service 22
DID 4DC0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Engine oil pressure SIERRA2500_EOP
- Service 22
DID 2345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Engine oil pressure SIERRA2500_EOP_DA11
- Service 22
DID 1470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Engine oil pressure SIERRA2500_EOP_DA11_2Confirmed
- Service 22
DID 1470 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
0x00 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine oil pressure 2 SIERRA2500_EOP_2
Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.
- Service 22
DID 115C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -21.6 to 131.39 psi
- Unit
- psi
In testing for 2001 to 2019. Not supported for 2024.
Engine oil pressure control solenoid valve command SIERRA2500_EOP_CTRL_SOLENOID_VALVE_CMD
- Service 22
DID 3318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2019. Not supported for 2024.
Engine oil pressure, actual SIERRA2500_EOP_ACTConfirmed
- Service 22
DID 2345 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1020 kPa
- Unit
- kPa
0x00 = 0 → = 0 kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Engine oil temperature SIERRA2500_EOT
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 005C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Engine oil temperature SIERRA2500_EOT_DA11
- Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Engine oil temperature SIERRA2500_EOT_DA11_2Confirmed
- Service 22
DID 005C - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x31 = 49 → = 9 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine oil temperature SIERRA2500_EOT_DA11_3Confirmed
- Service 22
DID 153E - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x00 = 0 → = -40 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024. Supported for 2004, 2022, 2025.
Engine torque SIERRA2500_ENG_TQ
- Service 22
DID 19DE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2001 to 2019. Not supported for 2024.
Engine torque SIERRA2500_ENG_TQ_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 N·m
- Unit
- N·m
In testing for 2001 to 2019. Not supported for 2024.
Evaporative emissions purge SIERRA2500_EVAPORATIVE
- Service 22
DID 1170 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Exhaust gas recirculation duty cycle SIERRA2500_EGR_DUTY
- Service 22
DID 1171 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Exhaust gas recirculation voltage SIERRA2500_EGR_V
- Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 5 V
- Unit
- V
In testing for 2001 to 2019. Not supported for 2024.
Heated oxygen sensor SIERRA2500_HEATED_OXYGEN_SENS
- Service 22
DID 1145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mV
- Unit
- mV
In testing for 2001 to 2019. Not supported for 2024.
Idle air control position SIERRA2500_IDLE_AIR_CTRL_POS
- Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Injector duty cycle bank 1 SIERRA2500_INJECTOR_DUTY_CYCLE_BANK_1
- Service 22
DID 12C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Injector duty cycle bank 2 SIERRA2500_INJECTOR_DUTY_CYCLE_BANK_2
- Service 22
DID 12C4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Injector pulse width, cylinder 1 SIERRA2500_INJ_WIDTH_CYL_1
- Service 22
DID 1193 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Injector pulse width, cylinder 7 SIERRA2500_INJ_WIDTH_CYL_7
- Service 22
DID 1199 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Injector pulse width, cylinder 8 SIERRA2500_INJ_WIDTH_CYL_8
- Service 22
DID 129A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Intake air temperature 2 SIERRA2500_IAT_2
- Service 22
DID 1538 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Knock retard SIERRA2500_KNOCK_RETARD
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 56.1 °
- Unit
- °
In testing for 2001 to 2019. Not supported for 2024.
Knock retard, alternate SIERRA2500_KNOCK_RETARD_ALT
- Service 22
DID 125D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °
- Unit
- °
In testing for 2001 to 2019. Not supported for 2024.
Knock sensor active counter SIERRA2500_KNOCK_SENS_ACTIVE
- Service 22
DID 125E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Last shift time SIERRA2500_LAST_SHIFT_TIME
- Service 22
DID 1992 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 6.375 s
- Unit
- s
In testing for 2001 to 2019. Not supported for 2024.
Mass airflow sensor SIERRA2500_MAF
- Service 22
DID 0010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 2001 to 2019. Not supported for 2024.
Mass airflow sensor SIERRA2500_MASS_AIRFLOW_SENSConfirmed
- Service 22
DID 0010 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 g/s
- Unit
- g/s
0x0000 = 0 → = 0 g/s
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfire current, cylinder 7 SIERRA2500_MIS_CURRENT_7
- Service 22
DID 11EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire current, cylinder 8 SIERRA2500_MIS_CURRENT_8
- Service 22
DID 11ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 1 SIERRA2500_MIS_HISTORY_1
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 2 SIERRA2500_MIS_HISTORY_2
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 3 SIERRA2500_MIS_HISTORY_3
- Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 4 SIERRA2500_MIS_HISTORY_4
- Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 5 SIERRA2500_MIS_HISTORY_5
- Service 22
DID 11F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 6 SIERRA2500_MIS_HISTORY_6
- Service 22
DID 11F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 7 SIERRA2500_MIS_HISTORY_7
- Service 22
DID 11FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfire history, cylinder 8 SIERRA2500_MIS_HISTORY_8
- Service 22
DID 11FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires current, cylinder 1 SIERRA2500_MIS_CURRENT_1Confirmed
- Service 22
DID 1206 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 2 SIERRA2500_MIS_CURRENT_2Confirmed
- Service 22
DID 1205 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 3 SIERRA2500_MIS_CURRENT_3Confirmed
- Service 22
DID 1207 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 4 SIERRA2500_MIS_CURRENT_4Confirmed
- Service 22
DID 1208 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 5 SIERRA2500_MIS_CURRENT_5Confirmed
- Service 22
DID 11EA - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 6 SIERRA2500_MIS_CURRENT_6Confirmed
- Service 22
DID 11EB - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 7 SIERRA2500_MIS_CURRENT_7_DA11Confirmed
- Service 22
DID 11EC - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires current, cylinder 8 SIERRA2500_MIS_CURRENT_8_DA11Confirmed
- Service 22
DID 11ED - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Misfires, current, cylinder 1 SIERRA2500_MISFIRES_C1_CUR
- Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires, current, cylinder 2 SIERRA2500_MISFIRES_C2_CUR
- Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires, current, cylinder 3 SIERRA2500_MISFIRES_C3_CUR
- Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires, current, cylinder 4 SIERRA2500_MISFIRES_C4_CUR
- Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires, current, cylinder 5 SIERRA2500_MISFIRES_C5_CUR
- Service 22
DID 11EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Misfires, current, cylinder 6 SIERRA2500_MISFIRES_C6_CUR
- Service 22
DID 11EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Outside air temperature SIERRA2500_AAT
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Particulate matter sensor soot accumulation SIERRA2500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION
- Service 22
DID 3635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Particulate matter sensor soot accumulation SIERRA2500_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION_DA11Confirmed
- Service 22
DID 3635 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Particulate matter sensor temperature SIERRA2500_PARTICULATE_MATTER_SNS_T
- Service 22
DID 3372 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Particulate matter sensor temperature SIERRA2500_PARTICULATE_MATTER_SNS_T_DA11Confirmed
- Service 22
DID 3372 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
0x0190 = 400 → = 40 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Pressure control solenoid current, actual SIERRA2500_P_CTRL_SOLENOID_ACT
- Service 22
DID 199E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2001 to 2019. Not supported for 2024.
Pressure control solenoid current, reference SIERRA2500_P_CTRL_SOLENOID
- Service 22
DID 199F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2001 to 2019. Not supported for 2024.
Remaining oil life SIERRA2500_REMAINING_OIL_LIFE
- Service 22
DID 119F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Total knock retard SIERRA2500_TOTAL_KNOCK_RETARD
- Service 22
DID 12D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 114.75 °
- Unit
- °
In testing for 2001 to 2019. Not supported for 2024.
Total misfire SIERRA2500_TOTAL_MISFIRE
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Transmission fluid temperature SIERRA2500_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 1940 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Transmission fluid temperature, variant 1 SIERRA2500_ATF_T_VAR_1
- Service 22
DID 1940 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Transmission fluid temperature, variant 6 SIERRA2500_ATF_T_VAR_6
- Service 22
DID 280D - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Fuel
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L/h
- Unit
- L/h
Confirmed for 2024 to 2025. Supported for 2004, 2022.
Ethanol content of fuel SIERRA2500_ETHANOL_CONTENT_FUEL
- Service 22
DID 0052 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Fuel consumption rate SIERRA2500_FUEL_CONS_RATEConfirmed
- Service 22
DID 005E - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel consumption rate SIERRA2500_FUEL_RATE
- Service 22
DID 005E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 L
- Unit
- L
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 1 SIERRA2500_FUEL_INJ_CYL_1Confirmed
- Service 22
DID 20AC - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 1 SIERRA2500_FUEL_INJECTION_C1
- Service 22
DID 20AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 2 SIERRA2500_FUEL_INJ_CYL_2Confirmed
- Service 22
DID 20AD - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 2 SIERRA2500_FUEL_INJECTION_C2
- Service 22
DID 1194 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 3 SIERRA2500_FUEL_INJ_CYL_3Confirmed
- Service 22
DID 20AE - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 3 SIERRA2500_FUEL_INJECTION_C3
- Service 22
DID 1195 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 4 SIERRA2500_FUEL_INJ_CYL_4Confirmed
- Service 22
DID 20AF - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 4 SIERRA2500_FUEL_INJECTION_C4
- Service 22
DID 1196 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 5 SIERRA2500_FUEL_INJ_CYL_5Confirmed
- Service 22
DID 20B0 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 5 SIERRA2500_FUEL_INJECTION_C5
- Service 22
DID 1197 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 6 SIERRA2500_FUEL_INJ_CYL_6Confirmed
- Service 22
DID 20B1 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.55 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 6 SIERRA2500_FUEL_INJECTION_C6
- Service 22
DID 1198 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel injection, cylinder 8 SIERRA2500_FUEL_INJ_CYL_8Confirmed
- Service 22
DID 20B3 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 ms
- Unit
- ms
0x0000 = 0 → = 0 ms
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Fuel injection, cylinder 8 SIERRA2500_FUEL_INJECTION_C8
- Service 22
DID 20B3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 2001 to 2019. Not supported for 2024.
Fuel remaining SIERRA2500_FLI
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 002F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2001 to 2019. Not supported for 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2004, 2022, 2025.
Fuel tank pressure SIERRA2500_FUEL_TANK_P
- Service 22
DID F432 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96 psi
- Unit
- psi
In testing for 2001 to 2019. Not supported for 2024.
Fuel temperature SIERRA2500_FUEL_T
- Service 22
DID 3218 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127.5 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Fuel temperature SIERRA2500_FUEL_T_DA11Confirmed
- Service 22
DID 3218 - Module
DA11 → 2AF111 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 °C
- Unit
- °C
0x30 = 48 → = 24 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Total fuel consumption rate SIERRA2500_TOT_FUEL_CONS_RATEConfirmed
- Service 22
DID 009D - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310 g/s
- Unit
- g/s
0x0000 = 0 → = 0 g/s
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Total fuel consumption rate SIERRA2500_TOTAL_FUEL_CONSUMPTION_RATE
- Service 22
DID 009D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 g/s
- Unit
- g/s
In testing for 2001 to 2019. Not supported for 2024.
Movement
Desired idle speed SIERRA2500_DES_IDLE_SPD
- Service 22
DID 1192 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 3187.5 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Torque converter clutch slip speed SIERRA2500_TC_SLIP_VSS
- Service 22
DID 1991 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Torque converter clutch slip speed SIERRA2500_TQ_CONV_CLU_SLIP_SPD
- Service 22
DID 1991 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095.875 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Torque converter clutch slip speed SIERRA2500_TQ_CONV_CLU_SLIP_SPD_DA18Confirmed
- Service 22
DID 1991 - Module
DA18 → 2AF118 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -4096 to 4095 rpm
- Unit
- rpm
0x0000 = 0 → = 0 rpm
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Vehicle speed SIERRA2500_VSS
Pelican can show this parameter as the speed.
- Service 22
DID 000D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004, 2024 to 2025.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024. Supported for 2004, 2022, 2025.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2025. Supported for 2004, 2022, 2024.
Orientation
Lateral acceleration SIERRA2500_LAT_GConfirmed
- Service 22
DID 4C2F - Module
DA28 → 2AF128 - Every
100 ms - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -52 to 52 g
- Unit
- g
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Longitudinal acceleration SIERRA2500_LNG_GConfirmed
- Service 22
DID 4C30 - Module
DA28 → 2AF128 - Every
100 ms - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -52 to 52 g
- Unit
- g
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Tires
Front left tire pressure SIERRA2500_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 5005 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Front left tire sensor ID SIERRA2500_TID_FL
- Service 22
DID 4005 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2001 to 2019. Not supported for 2024.
Front left wheel speed SIERRA2500_FL_WHL_SPDConfirmed
- Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Front right tire pressure SIERRA2500_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 5006 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Front right tire pressure SIERRA2500_TP_FR_DA40Confirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 5006 - Module
DA40 → 40 - Every
15 s - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Front right tire sensor ID SIERRA2500_TID_FR
- Service 22
DID 4006 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2001 to 2019. Not supported for 2024.
Front right wheel speed SIERRA2500_FR_WHL_SPDConfirmed
- Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Left front tire pressure SIERRA2500_TP_FL_7E0
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 248E - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004, 2024 to 2025.
Left rear tire pressure SIERRA2500_TP_RL_7E0
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 2491 - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004, 2024 to 2025.
Rear left tire pressure SIERRA2500_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 5008 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Rear left tire sensor ID SIERRA2500_TID_RL
- Service 22
DID 4008 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2001 to 2019. Not supported for 2024.
Rear left wheel speed SIERRA2500_RL_WHL_SPDConfirmed
- Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Rear right tire pressure SIERRA2500_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 5007 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 2001 to 2019. Not supported for 2024.
Rear right tire pressure SIERRA2500_TP_RR_DA40Confirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 5007 - Module
DA40 → 40 - Every
15 s - Testing for 2001 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Rear right tire sensor ID SIERRA2500_TID_RR
- Service 22
DID 4007 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 2001 to 2019. Not supported for 2024.
Rear right wheel speed SIERRA2500_RR_WHL_SPDConfirmed
- Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Right front tire pressure SIERRA2500_TP_FR_7E0
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 248F - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004, 2024 to 2025.
Right rear tire pressure SIERRA2500_TP_RR_7E0
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 2490 - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2001 to 2003, 2005 to 2019. Not supported for 2004, 2024 to 2025.
Transmission
Clutch slip, AT C1, ring SIERRA2500_CLU_SLIP_C1_RING
- Service 22
DID 2851 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Clutch slip, AT C3, ring SIERRA2500_CLU_SLIP_C3_RING
- Service 22
DID 19D4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Current gear SIERRA2500_CURRENT_GEAR
- Service 22
DID 1B30 - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -3 to 252
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Current gear SIERRA2500_CURRENT_GEAR_7E0
- Service 22
DID 199A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Current gear SIERRA2500_CURRENT_GEAR_DA18Confirmed
- Service 22
DID 1B30 - Module
DA18 → 2AF118 - Every
250 ms - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -3 to 252
- Unit
- Number
0x01 = 1 → = -2
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Current gear, variant 2 SIERRA2500_CURRENT_GEAR_VAR_2
- Service 22
DID 199A - Module
7E2 → 7EA - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Current gear, variant 3 SIERRA2500_CURRENT_GEAR_VAR_3
- Service 22
DID 3201 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2001 to 2019. Not supported for 2024.
Transmission fluid temperature SIERRA2500_ATF_T_DA18Confirmed
- Service 22
DID 1940 - Module
DA18 → 2AF118 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x38 = 56 → = 16 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Transmission fluid temperature filtered SIERRA2500_ATF_T_FILTEREDConfirmed
- Service 22
DID 295A - Module
DA18 → 2AF118 - Every
5 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x37 = 55 → = 15 °C
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Transmission fluid temperature, filtered SIERRA2500_TF_T_FLTED
- Service 22
DID 295A - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2001 to 2019. Not supported for 2024.
Transmission input shaft speed, 2 SIERRA2500_TRANS_ISS
- Service 22
DID 1941 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2001 to 2019. Not supported for 2024.
Trips
Diesel particulate filter, average distance between regeneration events SIERRA2500_DPF_AVG_DIST_BETWEEN_REGENSConfirmed
- Service 22
DID 20F7 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Diesel particulate filter, distance since last regeneration SIERRA2500_DPF_DIST_SINCE_LAST_REGENConfirmed
- Service 22
DID 3039 - Module
DA11 → 2AF111 - Every
1 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2024.
Odometer SIERRA2500_ODOConfirmed
- Service 22
DID 448F - Module
DA1A → 2AF11A - Every
30 s - Testing for 2001 to 2023, 2025 to 2026
Example reply from a 2024 GMC Sierra 2500HD.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 67108863 km
- Unit
- km
0x00339637 = 3380791 → = 52,824.85938 km
Confirmed for 2024. In testing for 2020 to 2023, 2025 to 2026.