Ford Sierra

Parameters

The Ford Sierra has 523 parameters.

How to read a parameter card

12V battery age FORD_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h
  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age FORD_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

12V battery current FORD_VEH_BAT_CURRENT

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

12V battery state of charge FORD_12V_SOC

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

12V battery temperature FORD_12V_T

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

12V battery voltage FORD_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

Aux 12V battery control mode FORD_AUX_12V_BAT_CTRL

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Average battery module voltage FORD_AVG_MODULE_V

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

Battery age FORD_BATT_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1825
Unit
Number

Battery capacity FORD_BAT_CAP

  • Service 22DID 485C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 Ah
Unit
Ah

Battery capacity too low for start/stop FORD_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery current too high for start/stop FORD_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery current, predicted FORD_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

Battery discharge power limit FORD_BAT_DCHG_POWER_LIM

  • Service 22DID 4852
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kW
Unit
kW

Battery pack lifetime charge out, throughput FORD_BAT_PACK_LIFETIME

  • Service 22DID 485D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 Ah
Unit
Ah

Battery percentage, state of charge FORD_BAT_PERCENTAGE_ST

  • Service 22DID 4028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

Battery quiescent current, low range FORD_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

Battery refresh cycle in progress for start/stop FORD_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery state detection status FORD_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Battery state of charge too low for start/stop FORD_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery temperature too low for auto stop FORD_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery voltage FORD_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

Battery voltage FORD_BAT_V_7E0

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

Battery voltage too low for auto restart FORD_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery voltage too low for cold cranking capability FORD_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Battery voltage too low for start/stop FORD_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Charge air cooler temperature FORD_CHG_AIR_COOLER_T

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8
Range
0 to 524280
Unit
Raw value

Charge air temperature FORD_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Charger digital mode FORD_EVSE_DIGITAL_MODE

  • Service 22DID 48B7
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1DC_E_MINUSDC E-
2DC_MINUS_PDC -P
3DC_EPDC EP
4AC_E_MINUSAC E-
5AC_MINUS_PAC -P
6AC_EPAC EP
7RESETReset
8OFFOff
9ESTABLISHEstablish
10FAULTFault

Charger input power available FORD_CHARGER_INPUT_POWER

  • Service 22DID 484E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327 kW
Unit
kW

Charger output voltage FORD_CHARGER_OUTPUT_V

  • Service 22DID 484A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

Charger type FORD_EVSE_TYPE

  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1LEVEL_1Level 1
2LEVEL_2Level 2
3DC
4BASICBasic
5HIGH_LEVELHigh Level
6BASIC_ACBasic AC
7HIGH_LEVEL_ACHigh Level AC
8HIGH_LEVEL_DCHigh Level DC
10NO_COMMNo communication
11FAULTFault
12HANDSHAKE_ENDHandshake end

Charging state FORD_CHRG_STATE

Pelican can show this parameter as the charging state.

  • Service 22DID 484F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1READYReady
2FAULTFault
3WAITWait Check
4PRE_CONDPre-condition
5CHARGINGCharging
6DONEDone
7EXTExternal Charger
8INITInitializing

Commanded generator voltage FORD_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

Contactor voltage negative FORD_CONTACTOR_V_NEG

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 300 V
Unit
V

Contactor voltage negative FORD_CONTACTOR_V_NEGATIVE

  • Service 22DID 4806
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

Contactor voltage positive FORD_CONTACTOR_V_POS

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 300 V
Unit
V

Contactor voltage positive FORD_CONTACTOR_V_POSITIVE

  • Service 22DID 4805
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 V
Unit
V

DC charger status FORD_DC_CHARGER_STAT

  • Service 22DID 489E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

DC charging system contactor voltage FORD_DC_CHG_SYSTEM_V

  • Service 22DID 48AF
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

DC-DC converter FORD_DCDC_ENABLED

  • Service 22DID 483D
  • Module746 → 74E
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

High voltage AC charger coupler temperature FORD_HIGH_V_AC_CHARGER_COUPLER_T

  • Service 22DID D117
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

High voltage AC charger coupler temperature FORD_HIGH_V_AC_CHARGER_T

  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

High voltage battery current FORD_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

High voltage battery intake air temperature FORD_HVBAT_IAT

  • Service 22DID 000F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

High voltage charger current, requested FORD_HIGH_V_CHARGER

  • Service 22DID 4842
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

High voltage charger input power available, raw count FORD_HIGH_V_CHARGER_INPUT

  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

High voltage charger output current measured FORD_HIGH_V_CHARGER_OUTPUT

  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

High voltage charger output reduction temperature FORD_HIGH_V_CHARGER_T

  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

High voltage charger output voltage, raw count FORD_HIGH_V_CHARGER_V

  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

High voltage charger pilot voltage FORD_HIGH_V_CHARGER_PILOT_V

  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

High voltage charger pilot voltage, raw count FORD_HIGH_V_CHARGER_PILOT_V_RAW

  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

High voltage charger status FORD_HIGH_V_CHARGER_STAT

  • Service 22DID 484D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

High voltage charger status FORD_HIGH_V_CHARGER_STAT_7E2

  • Service 22DID 484F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

High voltage charger voltage, requested FORD_HIGH_V_CHARGER_V_REQ

  • Service 22DID 4844
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 V
Unit
V

High voltage charger, maximum power FORD_HIGH_V_CHARGER_MAX

  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kW
Unit
kW

High voltage DC charger coupler temperature FORD_HIGH_V_DC_CHARGER_T

  • Service 22DID D00C
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

High voltage DC charger coupler temperature 1 FORD_HIGH_V_DC_CHARGER_T_1

  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

High voltage DC charger coupler temperature 3 FORD_HIGH_V_DC_CHARGER_T_3

  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

High voltage DC charger status FORD_HIGH_V_DC_CHARGER

  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

High voltage DC charger, maximum voltage FORD_HIGH_V_DC_CHARGER_MAX_V

  • Service 22DID 489D
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

High voltage DC charger, maximum, current FORD_HIGH_V_DC_CHARGER_MAX

  • Service 22DID 4899
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

High-voltage battery current FORD_HVB_CURRENT

  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

High-voltage battery voltage, raw count FORD_HVB_V_RAW_CNT

  • Service 22DID 480D
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

HV AC charger coupler temperature FORD_AC_CHG_COUPLER_T

  • Service 22DID 4888
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV AC charger input current FORD_AC_CHG_IN_A

  • Service 22DID 485F
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 A
Unit
A

HV AC charger input frequency FORD_AC_CHG_IN_FREQ

  • Service 22DID 4860
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 90 Hz
Unit
Hz

HV AC charger input voltage FORD_AC_CHG_IN_V

  • Service 22DID 485E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 V
Unit
V

HV battery age FORD_HVBAT_AGE

  • Service 22DID 4810
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×720200
Range
0 to 235926 h
Unit
h

HV battery average module voltage FORD_HVBAT_AVG_MOD_V

  • Service 22DID 4841
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 50 V
Unit
V

HV battery charge FORD_HVBAT_SOC

High resolution state of charge.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4801
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 100 %
Unit
%

HV battery charge current requested FORD_HVBAT_CCR

  • Service 22DID 4842
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 A
Unit
A

HV battery charge power limit FORD_HVBAT_CHG_PWR_LIM

  • Service 22DID 48FB
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 300 kW
Unit
kW

HV battery charge voltage requested FORD_HVBAT_CVR

  • Service 22DID 4844
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 500 V
Unit
V

HV battery charge, displayed FORD_HVBAT_SOC_DISP

The state of charge displayed on the vehicle's dashboard.

Pelican can show this parameter as the state of charge.

  • Service 22DID 4845
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

HV battery charging status FORD_HVBAT_CHG_STATUS

  • Service 22DID 484D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1WAITWait
2READYReady
3CHARGINGCharging
4DONEDone
5FAULTFault

HV battery coolant inlet temperature FORD_BAT_CLT_INLET_T

  • Service 22DID 4846
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

HV battery current FORD_HVBAT_A

Pelican can show this parameter as the traction battery current.

  • Service 22DID 48F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-600 to 600 A
Unit
A

HV battery current high range FORD_HVBAT_CHR_A

  • Service 22DID 4809
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 300 A
Unit
A

HV battery current, alternate FORD_HVBAT_A_ALT

  • Service 22DID 480B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-300 to 300 A
Unit
A

HV battery energy FORD_HVBAT_KWH

  • Service 22DID 4848
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val500
Range
0 to 131.07 kWh
Unit
kWh

HV battery maximum charge current FORD_HVBAT_MAX_CHG_A

  • Service 22DID 48BC
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 A
Unit
A

HV battery minimum module voltage FORD_HVBAT_MIN_MOD_V

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

HV battery modules voltage FORD_HVBAT_MOD_V

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

HV battery state of health FORD_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 490C
  • Module7E4 → 7EC
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

HV battery temperature FORD_HVBAT_T

  • Service 22DID 4800
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

HV battery temperature, average FORD_HVBAT_T_AVG

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

HV battery temperature, maximum FORD_HVBAT_T_MAX

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

HV battery temperature, minimum FORD_HVBAT_T_MIN

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

HV battery thermal operation mode FORD_HVBAT_THERMAL_OP_MODE

  • Service 22DID 48E0
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1EQUALIZEEqualize
2COOLANT_FLOWCoolant flow
3COOLANT_FANCoolant fan
4COOLANT_MODERATECoolant moderate
5COOLANT_MAXCoolant maximum
15HEATHeat

HV battery voltage FORD_HVBAT_V

  • Service 22DID 480D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

HV charger input power available FORD_CHG_PWR_AVAIL

  • Service 22DID 484E
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val200
Range
0 to 327.675 kW
Unit
kW

HV charger maximum power FORD_CHG_MAX_PWR

  • Service 22DID 48C4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 kW
Unit
kW

HV charger output current measured FORD_CHG_OUT_A

  • Service 22DID 4850
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 A
Unit
A

HV charger output reduction temperature FORD_CHG_OUT_REDUCT_T

  • Service 22DID 48A5
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

HV charger output voltage FORD_CHG_OUT_V

  • Service 22DID 484A
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 600 V
Unit
V

HV charger pilot duty cycle FORD_CHG_PILOT_DUTY

  • Service 22DID 4861
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

HV charger pilot voltage FORD_CHG_PILOT_V

  • Service 22DID 48B6
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 15 V
Unit
V

HV charger proximity status FORD_CHG_PROX_STATUS

  • Service 22DID 4862
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ON_S3On S3
2ONOn
310A10 A
413A13 A
516A16 A
620A20 A
7FAULTFault
832A32 A
963A63 A
16DC
17OPENOpen
18SHORTShort
19SHORT_PWRShort to power
20OUT_OF_RANGEOut of range
21OPEN_CIRCUITOpen circuit

HV charger proximity voltage FORD_CHG_PROX_V

  • Service 22DID 48A0
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val50
Range
0 to 5.1 V
Unit
V

HV DC charger coupler temperature 1 FORD_DC_CHG_COUPLER_T1

  • Service 22DID 4897
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV DC charger coupler temperature 3 FORD_DC_CHG_COUPLER_T3

  • Service 22DID 48A4
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

HV DC charger maximum current FORD_HVDC_CHG_MAX_C

  • Service 22DID 4899
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 A
Unit
A

HV DC charger maximum voltage FORD_HVDC_CHG_MAX_V

  • Service 22DID 489D
  • Module6F5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

HV DC charger status FORD_DC_CHG_STATUS

  • Service 22DID 489E
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_READYNot ready
1INITInitialize
2READYReady
3WAIT_CHECKWait check
4PRE_CONDITIONPre-condition
5CHARGINGCharging
6DONEDone
8WAITWait
9NOT_CAPABLENot capable
10FAULTFault
11CHARGER_CHECKCharger check

HV negative leakage voltage FORD_NEGATIVE_LEAKAGE_V

  • Service 22DID 4804
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

HV positive leakage voltage FORD_POSITIVE_LEAKAGE_V

  • Service 22DID 4803
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Hybrid battery pack remaining charge FORD_HYBRID_BAT_PACK

  • Service 22DID F45B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

Injection control pressure sensor voltage FORD_ICP_V

  • Service 22DID 16AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

Low voltage converter input current FORD_DCDC_HV_A

  • Service 22DID 483A
  • Module746 → 74E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25 A
Unit
A

Maximum discharge power limit FORD_CHG_POWER_LIM

  • Service 22DID 4815
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25100
Range
0 to 63.75 kW
Unit
kW

Minimum battery module voltage FORD_MIN_MODULE_V

  • Service 22DID 4840
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

Normalized cumulative charge when ignition is on FORD_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

Normalized cumulative discharge from battery with engine off FORD_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

Normalized cumulative discharge from battery with engine on FORD_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

PF differential pressure feedback EGR sensor voltage FORD_PF_DIFF_P_FEEDBACK_V

  • Service 22DID 03E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×9771000000
Range
-32.01 to 32.01 V
Unit
V

Primary motor inverter voltage FORD_PRIMARY_MOTOR_V

  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

Second battery current FORD_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

Second battery voltage FORD_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

SOC variation battery modules FORD_SOC_VARIATION_BAT

  • Service 22DID 483E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 %
Unit
%

Target/desired state of charge FORD_TARGET_SOC

  • Service 22DID 05A1
  • Module7E4 → 7EC
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Temperature range FORD_T_RANGE

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Temperature range average FORD_T_RANGE_AVG

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Temperature range, maximum FORD_T_RANGE_MAX

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Temperature range, minimum FORD_T_RANGE_MIN

  • Service 22DID 4808
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Traction battery voltage, alternate FORD_TRACTION_BAT_V_ALT

  • Service 22DID 490B
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 199 V
Unit
V

Vehicle battery voltage FORD_VEH_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

Voltage variation battery modules FORD_V_VARIATION_BAT

  • Service 22DID 483F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

Climate

A/C compressor current FORD_AC_COMP_A

  • Service 22DID 99AB
  • Module7C7
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10032767
Range
-100 to 100 A
Unit
A

A/C compressor pressure FORD_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

A/C compressor pressure sensor voltage FORD_AC_P_SENS_V

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

A/C compressor, state FORD_AC_STATE

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

A/C refrigerant pressure FORD_PCM_A_C_REFRIG_P

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Ambient temperature sensor voltage FORD_AAT_V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Ambient temperature, alternate FORD_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Coolant heater operation mode FORD_COOLANT_HTR_OP_MODE

  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

Coolant heater power FORD_COOLANT_HTR_PWR

  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 kW
Unit
kW

Exterior temperature FORD_AAT

  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Interior temperature FORD_IAT

  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Control

Anti-lock brake lateral acceleration FORD_ABS_LATERAL_ACCEL

  • Service 22DID 3A51
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g
Unit
g

Anti-lock brake wheel speed 1 FORD_ABS_WHL_SPD_1

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Anti-lock brake wheel speed 2 FORD_ABS_WHL_SPD_2

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Anti-lock brake wheel speed 3 FORD_ABS_WHL_SPD_3

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Anti-lock brake wheel speed 4 FORD_ABS_WHL_SPD_4

  • Service 22DID 3987
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Brake booster pressure FORD_BRAKE_BOOSTER_P

  • Service 22DID 2028
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 kPa
Unit
kPa

Brake hydraulic pressure FORD_BRK_FL_P

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Brake hydraulic pressure, raw count FORD_MAX_BRK_FL_P

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Foot brake FORD_FOOT_BRAKE

  • Service 22DID 3B40
  • Module703 → 70B
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Parking brake state FORD_PARKING_BRAKE

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Steering angle FORD_STEER_ANG

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20−1638.4
Range
-1638 to 1638 °
Unit
°

Steering wheel angle FORD_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 3201
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×6.25
Range
-790 to 790 °
Unit
°

Cruise control

Target speed FORD_CC_TGT_VSS

The speed of the vehicle ahead of you.

  • Service 22DID A224
  • Module764 → 76C
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×3.610
Range
-736 to 736 km/h
Unit
km/h

Doors

Driver door ajar FORD_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Hood ajar? FORD_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Lock status FORD_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

Passenger door ajar? FORD_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Rear left door ajar? FORD_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Rear right door ajar? FORD_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Trunk ajar? FORD_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Drivetrain

Primary motor coil temperature FORD_PRI_MOTOR_COIL_T

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

Primary motor inverter temperature FORD_PRI_MOTOR_INV_T

  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

Primary motor speed FORD_PRI_MOTOR_RPM

  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

Primary motor torque FORD_PRI_MOTOR_TQ

  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

Secondary motor coil temperature FORD_SEC_MOTOR_COIL_T

  • Service 22DID 4820
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

Secondary motor inverter temperature FORD_SEC_MOTOR_INV_T

  • Service 22DID 481E
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

Secondary motor inverter voltage FORD_SEC_MOTOR_INV_V

  • Service 22DID 4823
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-400 to 400 V
Unit
V

Secondary motor speed FORD_SEC_MOTOR_RPM

  • Service 22DID 4821
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

Secondary motor torque FORD_SEC_MOTOR_TQ

  • Service 22DID 481A
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-200 to 200 N·m
Unit
N·m

Engine

Accelerator position FORD_ACC_POS

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

Actual engine percent torque FORD_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

Actuator cam position corrected FORD_ACTUATOR_CAM_POS

  • Service 22DID 017C
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °
Unit
°

Actuator duty cycle output, commanded FORD_ACTUATOR_DUTY_OUTPUT_CMD

  • Service 22DID 017F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×1953500000
Range
-127 to 127 %
Unit
%

Air conditioning pressure FORD_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

Alternator 2 monitor FORD_ALTERNATOR_2_MON

  • Service 22DID 0455
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

Alternator current output FORD_ALTERNATOR_CURRENT

  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 A
Unit
A

Ambient air temperature FORD_AAT_7E0

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Barometric pressure FORD_BARO

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

Barometric pressure FORD_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

Barometric pressure sensor voltage FORD_BARO_V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Battery current FORD_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

Boost FORD_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

Bypass valve FORD_BPV_OPEN

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

Calculated soot in oil FORD_CALC_SOOT_OIL

  • Service 22DID 0508
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 7 of the reply.

Formula
val×8
Range
0 to 8
Unit
Off or on

Camshaft position error, exhaust FORD_VCT_EXH_ERR

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

Camshaft position error, intake FORD_VCT_INT_ERR

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

Camshaft position, exhaust actual FORD_VCT_EXH_ACT

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

Camshaft position, exhaust desired FORD_VCT_EXH_DES

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

Camshaft position, intake actual FORD_VCT_INT_ACT

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

Camshaft solenoid duty cycle, exhaust FORD_VCT_EXH_DUTY

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

Camshaft solenoid duty cycle, intake FORD_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

Catalyst temperature FORD_CAT_TEMP

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

Charge air temperature FORD_CAT

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

Charge air temperature 2 FORD_CHG_AIR_T_2

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

Charge air temperature sensor voltage FORD_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Charging inhibit - requested FORD_CHG_INHIBIT_REQ

  • Service 22DID 4878
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Charging station connection, raw count FORD_EVSE_CHG_RAW_CNT

  • Service 22DID 4851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Commanded generator duty FORD_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

Coolant heater power FORD_CLT_HEATER_POWER

  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 kW
Unit
kW

Coolant temperature FORD_ECT

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Current gear FORD_GEAR_V2

The automatic transmission gear. Numbers aren't yet mapped to named gears.

  • Service 22DID 1E12
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Cylinder 1 misfire count FORD_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 2 misfire count FORD_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 3 misfire count FORD_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 4 misfire count FORD_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 5 misfire count FORD_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 6 misfire count FORD_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 7 misfire count FORD_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder 8 misfire count FORD_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Cylinder head temperature FORD_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Cylinder head temperature FORD_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

Cylinder head temperature FORD_CYL_HEAD_T_7E0_2

  • Service 22DID F405
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Cylinder head temperature FORD_PCM_CYL_HEAD_T_CORR

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Cylinder head temperature, alternate FORD_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

Cylinder head temperature, sensor 2 FORD_PCM_CYL_HEAD_T_SENS_2_RAW

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Diesel exhaust fluid level FORD_DEF_LEVEL

  • Service 22DID 0487
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 L
Unit
L

Diesel particulate filter delta pressure FORD_DPF_DELTA_P

  • Service 22DID 116C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×7.928974
Range
0 to 519625 kPa
Unit
kPa

Diesel particulate filter regen status FORD_DPF_REGEN_STAT

  • Service 22DID 0966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val128
Range
0 to 1.99
Unit
Number

Diesel particulate filter regeneration status FORD_DPF_REGEN_STAT_F48B

  • Service 22DID F48B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

Diesel particulate filter soot level FORD_DPF_SOOT_LEVEL_C974

  • Service 22DID C974
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+8.192
Range
0 to 73.72
Unit
Number

Diesel particulate filter soot level percentage FORD_DPF_SOOT_LEVEL

  • Service 22DID 042C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0871944108−57.142857
Range
-57.14 to 5657 %
Unit
%

Diesel particulate filter soot load, variant 2 FORD_DPF_SOOT_LOAD

  • Service 22DID 0579
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

Distance since DTC clear FORD_DIST_DTC_CLR

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance since last complete DPF regeneration FORD_DIST_SINCE_COMPLETE_FD8A

  • Service 22DID FD8A
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.009977908
Range
0 to 653 km
Unit
km

Distance with MIL FORD_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

DTC counter FORD_DTC_CNT

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Engine load FORD_ENG_LOAD_PCT

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Engine load, actual FORD_ENG_LOAD_ACT

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Engine oil pressure FORD_EOP

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Engine oil pressure - desired FORD_EOP_DES

  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

Engine oil temperature FORD_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

Engine oil temperature FORD_EOT_7DF

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine oil temperature FORD_EOT_V2

  • Service 22DID 1310
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Engine oil temperature, alternate FORD_EOT_F45C

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID F45C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine oil temperature, variant 2 FORD_EOT_VAR_2

  • Service 22DID 1313
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Engine reference torque FORD_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Engine run time FORD_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

Engine run time FORD_RUN_TIME

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Engine speed FORD_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

EV supply equipment type detected FORD_EV_SUP_EQUIPMENT

  • Service 22DID 4851
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Evaporative pressure sensor, raw count FORD_EVAP_RAW

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Evaporative purge FORD_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

Exhaust back pressure FORD_EXH_BACK_P

  • Service 22DID 1445
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×29800
Range
0 to 2375 psi
Unit
psi

Exhaust gas recirculation FORD_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Exhaust gas recirculation cooler inlet temperature FORD_EGR_COOLER_INLET_T

  • Service 22DID 0569
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

Exhaust gas recirculation cooler outlet temperature FORD_EGR_COOLER_OUTLET_T

  • Service 22DID 055D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×391250
Range
-1022 to 1022 °C
Unit
°C

Exhaust gas recirculation duty cycle FORD_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Exhaust gas recirculation inlet temperature FORD_EGR_INLET_T

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

Exhaust gas recirculation open FORD_EGR_OPEN

  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

Exhaust gas recirculation temperature FORD_EGR_T_7E0

  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Exhaust gas recirculation temperature FORD_EGR_T_7E0_7E0

  • Service 22DID F46B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

Exhaust gas recirculation temperature a FORD_EGR_T

  • Service 22DID 115F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×950−40
Range
-40 to 11756 °F
Unit
°F

Exhaust gas recirculation throttle position signal FORD_EGR_THROTTLE_POS_SIG

  • Service 22DID 096C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

Exhaust gas recirculation valve position measured FORD_EGR_VLV_POS_MEAS

  • Service 22DID 09FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

Exhaust gas recirculation valve position, desired FORD_EGR_VLV_POS_DES

  • Service 22DID 09D2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

Exhaust gas temperature 1 FORD_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

Exhaust gas temperature 2 FORD_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

Exhaust gas temperature after oxidation catalyst, before particulate filter FORD_EGT_PRE_DPF

  • Service 22DID 0992
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

Exhaust gas temperature after particulate filter FORD_EGT_POST_DPF

  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

Exhaust gas temperature after turbo, before oxidation catalyst FORD_EGT_PRE_DOC

  • Service 22DID 0991
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val−40
Range
-40 to 1500 °C
Unit
°C

Exhaust gas temperature, bank 1 FORD_EGT_B1

  • Service 22DID F478
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513 °C
Unit
°C

Forward sensing module automatic alignment offset FORD_FSM_AUTOMATIC

  • Service 22DID A220
  • Module764 → 76C
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

Fuel pressure sensor voltage, low FORD_LPFP_SENS_V

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Fuel pressure, low actual FORD_LPFP_ACT

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

Fuel pressure, low desired FORD_LPFP_DES

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

Fuel pump duty cycle, low pressure FORD_LPFP_DUTY

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

Fuel pump pulse width, bank 1 FORD_FUEL_PMP_WIDTH_BANK_1

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

Fuel pump pulse width, bank 2 FORD_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

Fuel rail pressure, desired FORD_HPFP_DES

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

Fuel rail sensor voltage, high pressure FORD_HPFP_V

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Fuel trim, long term FORD_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Fuel trim, short term FORD_STFT

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Generator coil temperature FORD_GEN_COIL_T

  • Service 22DID 4972
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×180+320
Range
0 to 11796620 °F
Unit
°F

Generator coil temperature FORD_GEN_COIL_T_7E6

  • Service 22DID 4820
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95
Range
-58982 to 58980 °C
Unit
°C

Generator control FORD_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

Generator current FORD_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

Glow plug, commanded status FORD_GLOW_PLUG_CMD_STAT

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

Grill shutter duty cycle FORD_GRILL_SHUT_DC

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Grill shutter position FORD_GRILL_SHUTTER_POS

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

High voltage current FORD_HIGH_V_CURRENT

  • Service 22DID 480B
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

High voltage leakage resistance bus negative FORD_HIGH_V_LEAKAGE_RES

  • Service 22DID 4812
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

High voltage leakage resistance bus overall, raw count FORD_HIGH_V_LEAKAGE_RES_BUS_V2

  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

High voltage leakage resistance bus positive FORD_HIGH_V_LEAKAGE_RES_BUS

  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

High voltage leakage resistance bus positive, raw count FORD_HIGH_V_LEAKAGE_RES_BUS_POSITIVE

  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Hydraulic pump motor current FORD_HYDRAULIC_PMP_MOTOR

  • Service 22DID D00F
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

Ignition correction, cylinder 1 FORD_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

Ignition timing, cylinder 1 FORD_IGN_TIM_CYL1

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

In car temperature FORD_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

Injection control pressure FORD_INJ_CTRL_P

  • Service 22DID 1446
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×57100
Range
0 to 37354 psi
Unit
psi

Injection mode FORD_INJ_MODE

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

Injection pressure regulator duty cycle FORD_IPR_DUTY

  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2564
Range
0 to 99.6 %
Unit
%

Injector control module cam and crank sync FORD_FICM_SYNC

  • Service 22DID 09CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

Injector control module logic power FORD_FICM_LOGIC_POWER

  • Service 22DID 09CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

Injector control module main power FORD_FICM_MAIN_POWER

  • Service 22DID 09D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255 V
Unit
V

Injector impulse width FORD_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

Intake air temperature 1 FORD_IAT_1

  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

Intake air temperature 2 FORD_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

Intake temperature fault FORD_IAT_FAULT

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Intake temperature sensor voltage FORD_IAT_SENS_V

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Intake temperature, alternate FORD_IAT_ALT2

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Knock counter, cylinder 1 FORD_PCM_CYL_1_KNK_COMB_PERF_CNT

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock counter, cylinder 2 FORD_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock counter, cylinder 3 FORD_PCM_CYL_3_KNK_COMB_PERF_CNT

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock counter, cylinder 4 FORD_PCM_CYL_4_KNK_COMB_PERF_CNT

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock counter, cylinder 5 FORD_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock counter, cylinder 6 FORD_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Knock sensor, 1 FORD_KS1_RAW

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Knock sensor, 2 FORD_KS2_RAW

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Lambda correction FORD_CL_LC

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

Lambda, commanded FORD_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

Leakage resistance bus overall FORD_LEAKAGE_RES_BUS

  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kΩ
Unit
kΩ

Low oil pressure switch FORD_LOW_OIL_P_SWITCH

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Low voltage converter current, high side FORD_LVB_DCDC_HV_CURRENT

  • Service 22DID 483A
  • Module746 → 74E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 A
Unit
A

Low voltage converter current, low side FORD_LVB_DCDC_LV_CURRENT

  • Service 22DID 4836
  • Module746 → 74E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

Manifold absolute pressure, high resolution FORD_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

Manifold air temperature FORD_MANIFOLD_AIR_T

  • Service 22DID 16E0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

Manifold pressure FORD_MAP

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

Manifold pressure sensor voltage FORD_MAP_V

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Manifold temperature FORD_MCT

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

Mass airflow sensor frequency FORD_MASS_AIRFLOW_SENS

  • Service 22DID 033D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 Hz
Unit
Hz

Misfire acceleration, cylinder 1 FORD_PCM_MISF_ACCEL_CYL1_NORM

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire acceleration, cylinder 2 FORD_PCM_MISF_ACCEL_CYL2_NORM

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire acceleration, cylinder 3 FORD_PCM_MISF_ACCEL_CYL3_NORM

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire acceleration, cylinder 4 FORD_PCM_MISF_ACCEL_CYL4_NORM

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire acceleration, cylinder 5 FORD_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire acceleration, cylinder 6 FORD_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

Misfire events, latest cycle FORD_PCM_MISF_EVENTS_LATEST_CYC

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

Misfire monitor status FORD_MIS_MON_STAT

  • Service 22DID 03C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Motor coil temperature FORD_MOTOR_COIL_T

  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×95+32
Range
-58950 to 59012 °F
Unit
°F

Motor electronic coolant temperature II FORD_MOTOR_ELECTRONIC_ECT

  • Service 22DID 4983
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−39.8
Range
-39.8 to 419 °F
Unit
°F

Motor electronics coolant temperature FORD_MOTOR_ELECTRONICS

  • Service 22DID 4832
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95+32
Range
0 to 491 °F
Unit
°F

Navigation altitude FORD_SYNC_GPS_ALTITUDE

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Navigation heading FORD_SYNC_GPS_HEADING

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

O2 sensor voltage, rear FORD_RO2_V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

Octane adjustment FORD_OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

Oil life remaining FORD_PCM_ENG_OIL_LIFE_REM

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Oil pressure FORD_PCM_ENG_EOP_RAW

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Outdoor temperature, BCM FORD_OUTDOOR_T_BCM

  • Service 22DID DD05
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Outside temperature FORD_OUTSIDE_T

  • Service 22DID DD05
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

Power transfer unit sump temperature FORD_POWER_TRANSFER_UNIT_T

  • Service 22DID 0184
  • Module703 → 70B
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 °C
Unit
°C

Power transfer unit, requested torque FORD_POWER_TRANSFER_UNIT_REQ_TQ

  • Service 22DID 0182
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Power transfer unit, requested torque capacity inferred FORD_POWER_TRANSFER_UNIT_REQ_TQ_CAP

  • Service 22DID 0185
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Secondary motor torque, commanded FORD_SECONDARY_MOTOR_TQ_CMD

  • Service 22DID 4819
  • Module7E7 → 7EF
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

Shift gear FORD_GEAR_SHFT_V2

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Steering angle from the body module, actual value FORD_BCM_STEER_ANG_ACT

  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−780
Range
-780 to 5773 °
Unit
°

Steering shaft torque FORD_STEER_SHFT_TQ

  • Service 22DID 330C
  • Module730
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

Sump oil temperature measured FORD_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Temperature inside car FORD_T_INSIDE_CAR

  • Service 22DID DD04
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×95−40
Range
-40 to 419 °F
Unit
°F

Throttle angle, actual FORD_ETC_ANG_ACT

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Throttle angle, desired FORD_ETC_ANG_DES

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Throttle control trim angle, learned FORD_ETC_TRIM_LRN

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

Throttle inlet pressure FORD_TIP_ABS

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

Throttle inlet pressure sensor voltage FORD_TIP_V

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

Throttle inlet pressure, desired FORD_TIP_DES_ABS

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

Time since last oil change FORD_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

Torque converter slip FORD_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

Torque into torque converter FORD_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

Torque into torque converter FORD_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

Torque request FORD_TRQ_CTRL_REQ

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Total misfire count FORD_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Transfer case fluid temperature FORD_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

Transmission fluid temperature, variant 1 FORD_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

Transmission fluid temperature, variant 2 FORD_ATF_T_VAR_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

Transmission fluid temperature, variant 5 FORD_ATF_T_VAR_5

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

Transmission fluid temperature, variant 6 FORD_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

Transmission oil temperature FORD_TOT_7E0

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

Turbo boost FORD_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Turbo inlet pressure FORD_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

Variable geometry turbo duty cycle FORD_VGT_DUTY

  • Service 22DID 096D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032767
Range
0 to 200 %
Unit
%

Warm-ups since DTC clear FORD_WARMUP_CLR

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Wastegate control FORD_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

Wastegate duty cycle FORD_WGDC

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

Yaw rate signal FORD_YAW_RATE_SIG

  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

FORD

Accelerator Pedal Position FORD_[ECU] Accelerator pedal position

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.5
Range
0 to 100 %
Unit
%

Air conditioning compressor pressure FORD_[ECU] AC Pressure

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.2900754962
Range
-100 to 1000 psi
Unit
psi

Ambient air temperature sensor voltage FORD_[ECU] AAT Sensor V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

Barometric pressure FORD_[ECU] Baro

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0362553791
Range
8 to 20 psi
Unit
psi

Barometric pressure sensor voltage FORD_[ECU] Baro Sensor V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

Closed loop lambda correction FORD_[ECU] CL Lambda Corr

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.99
Unit
Number

Commanded lambda FORD_[ECU] Commanded lambda

The ratio of of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000305176
Range
0 to 5
Unit
Number

Engine coolant temperature FORD_[ECU] ECT

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-40 to 148.889 °C
Unit
°C

High pressure fuel pressure desired FORD_[ECU] HPFP Desired

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.450377397
Range
0 to 3500 psi
Unit
psi

High pressure fuel rail sensor voltage FORD_[ECU] HPFP sensor voltage

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

Low pressure fuel pump commanded duty cycle FORD_[ECU] LPFP duty cycle

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

Manifold absolute pressure sensor voltage FORD_[ECU] MAP voltage

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0009765625
Range
0 to 5 V
Unit
V

Octane adjust ratio FORD_[ECU] OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
-1 to 1
Unit
Number

Rear O2 voltage FORD_[ECU] Rear O2 V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0009765625
Range
0 to 1 V
Unit
V

Throttle inlet pressure absolute FORD_[ECU] TIP actual abs

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0011064263
Range
0 to 60 psi
Unit
psi

Throttle inlet pressure sensor voltage FORD_[ECU] TIP sensor voltage

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048828125
Range
0 to 5 V
Unit
V

VCT exhaust cam desired FORD_[ECU] VCT Exh Des

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
0 to 50 °
Unit
°

VCT exhaust camshaft actual FORD_[ECU] VCT exhaust actual

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

VCT exhaust camshaft error FORD_[ECU] VCT exhaust error

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

VCT exhaust camshaft solenoid duty cycle FORD_[ECU] VCT exhaust duty cycle

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

VCT intake cam desired FORD_[ECU] VCT Int Des

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 40 °
Unit
°

VCT intake camshaft actual FORD_[ECU] VCT intake actual

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

VCT intake camshaft solenoid duty cycle FORD_[ECU] VCT intake duty cycle

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

FORD_ETC_TRIM

Electronic throttle control learned trim angle FORD_ETC_TRIM_LEARNED

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-63.9 to 64 °
Unit
°

FORD_EVAP

Evaporative vapor pressure sensor voltage FORD_EVAP_V

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

FORD_VCT_INT

Variable camshaft timing intake cam desired FORD_VCT_INT_DES

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

Fuel

Air/fuel ratio FORD_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

Cylinder 1 fuel balance correction FORD_CYL_1_FUEL_BALANCE

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 1 fuel quantity FORD_CYL_1_FUEL_QTY

  • Service 22DID 04AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 2 fuel balance correction FORD_CYL_2_FUEL_BALANCE

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 2 fuel quantity FORD_CYL_2_FUEL_QTY

  • Service 22DID 04AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 3 fuel balance correction FORD_CYL_3_FUEL_BALANCE

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 3 fuel quantity FORD_CYL_3_FUEL_QTY

  • Service 22DID 04AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 4 fuel balance correction FORD_CYL_4_FUEL_BALANCE

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 4 fuel quantity FORD_CYL_4_FUEL_QTY

  • Service 22DID 04AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 5 fuel balance correction FORD_CYL_5_FUEL_BALANCE

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 5 fuel quantity FORD_CYL_5_FUEL_QTY

  • Service 22DID 04AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 6 fuel balance correction FORD_CYL_6_FUEL_BALANCE

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 6 fuel quantity FORD_CYL_6_FUEL_QTY

  • Service 22DID 04AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 7 fuel balance correction FORD_CYL_7_FUEL_BALANCE

  • Service 22DID 04A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 7 fuel quantity FORD_CYL_7_FUEL_QTY

  • Service 22DID 04B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 8 fuel balance correction FORD_CYL_8_FUEL_BALANCE

  • Service 22DID 04A5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Cylinder 8 fuel quantity FORD_CYL_8_FUEL_QTY

  • Service 22DID 04B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits. The value is signed.

Formula
val128000
Range
-65.53 to 65.53
Unit
Number

Dilution of oil with fuel FORD_DILUTION_OIL_FUEL

  • Service 22DID 054C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

Engine fuel rate FORD_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

Fuel correction, cylinder 1 FORD_FUEL_CORR_CYL_1

  • Service 22DID 098A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel correction, cylinder 2 FORD_FUEL_CORR_CYL_2

  • Service 22DID 098B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel correction, cylinder 3 FORD_FUEL_CORR_CYL_3

  • Service 22DID 098C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel correction, cylinder 4 FORD_FUEL_CORR_CYL_4

  • Service 22DID 098D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel correction, cylinder 5 FORD_FUEL_CORR_CYL_5

  • Service 22DID 11D3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel correction, cylinder 6 FORD_FUEL_CORR_CYL_6

  • Service 22DID 048F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383
Unit
Raw value

Fuel injection impulse width FORD_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

Fuel level FORD_FLI_16C1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

Fuel level FORD_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel level (alternative) FORD_FLI_V2

  • Service 22DID F42F
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Fuel pulse width FORD_FUEL_WIDTH

  • Service 22DID 1410
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125
Range
0 to 524 ms
Unit
ms

Fuel pump duty cycle FORD_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

Fuel rail pressure control FORD_FUEL_RAIL_P_CTRL

  • Service 22DID 03C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

Fuel tank level FORD_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Fuel tank pressure FORD_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

Fuel temperature FORD_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Fuel temperature a FORD_FUEL_T_7E0

  • Service 22DID 0429
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Low side fuel rail pressure FORD_LOW_SIDE_FUEL_RAIL_P

  • Service 22DID 064E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767 kPa
Unit
kPa

Mass fuel, desired FORD_MASS_FUEL_DES

  • Service 22DID 1412
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

Volume fuel, desired FORD_VOLUME_FUEL_DES

  • Service 22DID 1411
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095
Unit
Number

Lights

Exterior lighting state FORD_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

High beam status FORD_HIGH_BEAM

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

Movement

Accelerator pedal position FORD_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

Actual output shaft speed FORD_ACT_OUTPUT_SHFT_SPD

  • Service 22DID 1E1B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

Actual turbine shaft speed FORD_ACT_TURBINE_SHFT_SPD

  • Service 22DID 1E13
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 rpm
Unit
rpm

Coolant pump a control speed, commanded FORD_CLT_PMP_CTRL_SPD_CMD

  • Service 22DID 011A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Coolant pump b control speed, commanded FORD_CLT_PMP_B_CTRL_SPD_CMD

  • Service 22DID 0117
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Fan speed demanded FORD_FAN_SPD_DEMANDED

  • Service 22DID 0701
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

Fan speed indicated FORD_FAN_SPD_INDICATED

  • Service 22DID 0702
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

Fan speed sensor FORD_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Fan speed, desired FORD_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

Front left wheel speed FORD_FL_VSS

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

Front right wheel speed FORD_FR_VSS

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

Lateral acceleration FORD_LAT_G

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

Lateral angle FORD_LAT_ANG

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

Navigation speed FORD_SYNC_GPS_SPD

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

Power transfer unit input shaft speed FORD_POWER_TRANSFER_UNIT

  • Service 22DID 017E
  • Module703 → 70B
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 rpm
Unit
rpm

Rear left wheel speed FORD_RL_VSS

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

Rear right wheel speed FORD_RR_VSS

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

Traction motor speed FORD_TRACTION_MOTOR_SPD

  • Service 22DID 496A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 rpm
Unit
rpm

Vehicle speed FORD_VSS

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Vehicle speed, high resolution FORD_VSS_HD

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

Tires

4 wheel drive engaged FORD_4_WHL_DRIVE_ENGAGED

  • Service 22DID A211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

Front left tire pressure FORD_MAX_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Front left tire pressure FORD_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Front right tire pressure FORD_MAX_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Front right tire pressure FORD_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear left inner tire pressure FORD_TP_RLI

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear left inner tire pressure slot FORD_TP_RLI_RAW

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Rear left outer tire pressure FORD_MAX_TP_RLO

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear left outer tire pressure FORD_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear left outer tire pressure FORD_TP_RLO

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

Rear right inner tire pressure FORD_TP_RRI

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear right inner tire pressure slot FORD_TP_RRI_RAW

A rear inner tire position, which this car does not have. Raw count; dual-wheel trucks read it at 1/20 psi.

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Rear right outer tire pressure FORD_MAX_TP_RRO

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear right outer tire pressure FORD_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear right outer tire pressure FORD_TP_RRO

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

Tire pressure warning indicator FORD_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every30 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Tire temperature FORD_TYRE_T

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Transmission

Actual torque converter slip FORD_ACT_TQ_CONV_SLIP

  • Service 22DID 1E14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

All-wheel drive clutch diagnostic signal FORD_AWD_CLU_DIAGNOSTIC

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

All-wheel drive clutch, commanded control signal FORD_AWD_CLU_CMD_CTRL_SIG

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

Axle gear ratio, measured FORD_AXLE_GEAR_RATIO_MEAS

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

Converter speed ratio FORD_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

Current gear FORD_GEAR

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

Current gear, transmission module FORD_GEAR_7DF

The automatic transmission gear, as the transmission module reports it.

  • Service 22DID 1E12
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Desired torque converter slip FORD_DES_TQ_CONV_SLIP

  • Service 22DID 1E35
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

Gear FORD_GEAR_7E1

  • Service 22DID 1E1F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047
Unit
Number

Gear commanded FORD_GEAR_CMD

  • Service 22DID 1E12
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNKNOWNUnknown
20L
40D
50N
60R
70P
255FAULTFault

Gear ratio, commanded FORD_PCM_CMD_TRANS_GEAR_RATIO

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

Gear, engaged FORD_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

Gear, shift FORD_GEAR_SHFT

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Measured current of clutch a actuator FORD_MEAS_CURRENT_CLU

  • Service 22DID 1E9E
  • Module703 → 70B
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 A
Unit
A

Shift gear FORD_GEAR_SHFT_V2_7DF

Selected range. Neutral, reverse and park are mapped; the code driving reports (43) is not yet.

  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Torque converter line pressure FORD_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

Torque into torque converter, variant 2 FORD_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

Transmission fluid fluid quality FORD_TRANS_FLUID_FLUID

  • Service 22DID 180F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Transmission gear FORD_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

Transmission gear FORD_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

Transmission gear ratio FORD_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

Transmission odometer FORD_TRANS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Transmission oil temperature FORD_TOT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-40 to 255 °C
Unit
°C

Transmission oil temperature FORD_TOT_V2

  • Service 22DID 1E1C
  • Module7DF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 255 °C
Unit
°C

Transmission output shaft speed FORD_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

Transmission pressure, commanded FORD_PCM_CMD_TRANS_MAIN_LINE_P

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

Transmission temperature FORD_TT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-300 to 300 °C
Unit
°C

Trips

Battery current, high range FORD_CURRENT_HIGH_RANGE

  • Service 22DID 4809
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 A
Unit
A

Distance since last complete regeneration FORD_DIST_SINCE_COMPLETE

  • Service 22DID 0434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val×625
Range
0 to 4026531 mi
Unit
mi

Distance since last oil change FORD_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Distance to empty, calculated FORD_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

Distance to empty, displayed FORD_DTE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

HV battery current, low range FORD_HVB_CURRENT_LOW

  • Service 22DID 480A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-655 to 655 A
Unit
A

Odometer FORD_BECM_ODO

  • Service 22DID 6182
  • Module7E4 → 7EC
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×12815625
Range
0 to 536
Unit
Number

Odometer FORD_MAX_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer FORD_ODO

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

Odometer FORD_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

Odometer FORD_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, battery control module FORD_ODO_BCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, brake module FORD_ABS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module760 → 768
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, forward sensing module FORD_ODO_FSM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module764 → 76C
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, instrument panel FORD_MAX_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, instrument panel FORD_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Odometer, instrument panel FORD_ODO_V3

Pelican can show this parameter as the odometer.

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

Odometer, power steering module FORD_ODO_PSCM

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module730 → 738
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

Total distance, lifetime FORD_TOT_DIST_LIFETIME

  • Service 22DID F817
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 km
Unit
km

Trip distance FORD_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

Vehicle odometer FORD_PCM_VEH_ODO

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.