Ford Flex

Parameters

The Ford Flex has 127 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage FLEX_VEH_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7E = 126 → 12620+6 = 12.3 V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery current FLEX_VEH_BAT_CURRENTConfirmed

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

0x64 = 100 → 100−127 = -27 A

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

12V battery voltage FLEX_VEH_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

0x7E = 126 → 12620+6 = 12.3 V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Aux 12V battery control mode FLEX_AUX_12V_BAT_CTRLConfirmed

  • Service 22DID 40D1
  • Module726 → 72E
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Battery age FLEX_BATT_AGEConfirmed

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1825
Unit
Number

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Battery charge FLEX_BATT_SOCConfirmed

  • Service 22DID 4028
  • Module726 → 72E
  • Every10 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x46 = 70 → 70 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Battery temperature FLEX_BATT_TEMPConfirmed

  • Service 22DID 4029
  • Module726 → 72E
  • Every10 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

0x17 = 23 → 23−40 = -17 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Commanded generator voltage FLEX_CMD_GEN_VConfirmed

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

0x6666 = 26214 → 26214×0.000488 = 12.792432 V

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Normalized cumulative charge when ignition is on FLEX_NORM_CUM_CHG_IGN_ONConfirmed

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x04EC = 1260 → 126010 = 126

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Normalized cumulative discharge from battery with engine off FLEX_NORM_CUM_DCHG_BAT_OFFConfirmed

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x0096 = 150 → 15010 = 15

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Normalized cumulative discharge from battery with engine on FLEX_NORM_CUM_DCHG_BAT_ONConfirmed

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

0x006D = 109 → 10910 = 10.9

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Climate

A/C compressor pressure sensor voltage FLEX_AC_P_SENS_VConfirmed

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

A/C compressor, state FLEX_AC_STATEConfirmed

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

0x00 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Ambient temperature, alternate FLEX_AAT_ALTConfirmed

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x2A = 42 → 422−40 = -19 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Control

Brake hydraulic pressure, raw count FLEX_BRK_FL_PConfirmed

  • Service 22DID 2B0D
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Focus parking brake state FLEX_PARKING_BRAKEConfirmed

  • Service 22DID 2B00
  • Module760 → 768
  • Every3 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2013, 2016. Supported for 2011, 2018.

Engine

Absolute load value LOAD_ABSSAE J1979Confirmed

Pelican can show this parameter as the absolute engine load.

  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

Confirmed for 2016. Supported for 2013.

Air conditioning pressure FLEX_AC_P_7E0Confirmed

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

0x00 = 0 → 0×12.156863 = 0 kPa

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2013.

Ambient air temperature FLEX_AAT_7E0Confirmed

  • Service 22DID F446
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x2B = 43 → 43−40 = 3 °C

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2013, 2016. Supported for 2011, 2018.

Catalyst temperature FLEX_CAT_TEMPConfirmed

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

0x0659 = 1625 → 162510−40 = 122.5 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2013, 2016.

Commanded generator duty FLEX_CMD_GEN_DUTYConfirmed

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×0.003052 = 0 %

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Cylinder head temperature FLEX_PCM_CYL_HEAD_T_CORRConfirmed

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

0x0084 = 132 → 13264 = 2.0625 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Distance since DTC clear FLEX_DIST_DTC_CLRConfirmed

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0xFFFF = 65535 → 65,535 km

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Distance with MIL FLEX_MIL_DISTConfirmed

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x0000 = 0 → 0 km

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

DTC counter FLEX_DTC_CNTConfirmed

  • Service 22DID D137
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013, 2016. Supported for 2011, 2018.

Engine load FLEX_ENG_LOAD_PCTConfirmed

Pelican can show this parameter as the engine load.

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Engine load, actual FLEX_ENG_LOAD_ACTConfirmed

Pelican can show this parameter as the engine load.

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

0x0000 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Engine oil temperature FLEX_EOTConfirmed

  • Service 22DID 1310
  • Module7DF
  • Every30 s
  • Testing for 2009 to 2012, 2014 to 2019

Example reply from a 2013 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2013. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2016.

Engine RPM RPMSAE J1979Confirmed

Pelican can show this parameter as the engine speed.

  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2016. Supported for 2011, 2013, 2018.

Engine run time FLEX_ERTConfirmed

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2009 to 2012, 2014 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

0x00 = 0 → 0 s

Confirmed for 2013, 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019.

Engine run time FLEX_RUN_TIMEConfirmed

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

0x0000 = 0 → 0 s

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Engine speed FLEX_RPMConfirmed

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every100 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

0x0000 = 0 → 04 = 0 rpm

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Evaporative purge FLEX_EVAP_PURGE_CMDConfirmed

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×10032768 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Fuel trim, long term FLEX_LTFTConfirmed

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every500 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x74 = 116 → 116×100128−100 = -9.375 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Fuel trim, short term FLEX_STFTConfirmed

Pelican can show this parameter as the short term fuel trim.

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

0x5B = 91 → 91×100128−100 = -28.90625 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Generator control FLEX_GEN_CTRLConfirmed

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

0x1BA0 = 7072 → 7072×0.003052 = 21.583744 %

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Generator current FLEX_GEN_CURRENTConfirmed

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

0x092B = 2347 → 2347×78150000 = 36.66014 A

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Glow plug, commanded status FLEX_GLOW_PLUG_CMD_STATConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−4
Range
-4 to 251
Unit
Number

0x00 = 0 → 0−4 = -4

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Grill shutter duty cycle FLEX_GRILL_SHUT_DCConfirmed

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Grill shutter position FLEX_GRILL_SHUTTER_POSConfirmed

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Ignition correction, cylinder 1 FLEX_IGN_CORR_CYL1Confirmed

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Ignition timing, cylinder 1 FLEX_IGN_TIM_CYL1Confirmed

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

0x0000 = 0 → 04 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Injector control module cam and crank sync FLEX_FICM_SYNC

  • Service 22DID 09CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2009 to 2015, 2017 to 2019. Not supported for 2016.

Intake temperature fault FLEX_IAT_FAULTConfirmed

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x00 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Intake temperature sensor voltage FLEX_IAT_SENS_VConfirmed

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Intake temperature, alternate FLEX_IAT_ALT2Confirmed

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x1E = 30 → 30−40 = -10 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Knock sensor, 1 FLEX_KS1_RAWConfirmed

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Knock sensor, 2 FLEX_KS2_RAWConfirmed

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Low oil pressure switch FLEX_LOW_OIL_P_SWITCHConfirmed

  • Service 22DID 0416
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Manifold pressure FLEX_MAPConfirmed

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 1 FLEX_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 2 FLEX_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 3 FLEX_PCM_MISF_ACCEL_CYL3_NORMConfirmed

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 4 FLEX_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 5 FLEX_PCM_MISF_ACCEL_CYL5_NORMConfirmed

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire acceleration, cylinder 6 FLEX_PCM_MISF_ACCEL_CYL6_NORMConfirmed

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

0x00 = 0 → 064 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Misfire events, latest cycle FLEX_PCM_MISF_EVENTS_LATEST_CYCConfirmed

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

0x00000000 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Navigation altitude FLEX_SYNC_GPS_ALTITUDEConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00AD = 173 → 173

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Navigation heading FLEX_SYNC_GPS_HEADINGConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

0x00CA = 202 → 202 °

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Oil life remaining FLEX_PCM_ENG_OIL_LIFE_REMConfirmed

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x14 = 20 → 20 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013. Supported for 2011, 2016, 2018.

Steering angle from the body module, actual value FLEX_BCM_STEER_ANG_ACTConfirmed

  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−780
Range
-780 to 5773 °
Unit
°

0x1DE2 = 7650 → 765010−780 = -15 °

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Steering shaft torque FLEX_STEER_SHFT_TQConfirmed

  • Service 22DID 330C
  • Module730 → 738
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10−12.7
Range
-12.7 to 12.8 N·m
Unit
N·m

0x70 = 112 → 11210−12.7 = -1.5 N·m

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Throttle angle, actual FLEX_ETC_ANG_ACTConfirmed

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Throttle angle, desired FLEX_ETC_ANG_DESConfirmed

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

0x0000 = 0 → 0512 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Torque request FLEX_TRQ_CTRL_REQConfirmed

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x00 = 0 → 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Transmission oil temperature FLEX_TOTConfirmed

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

0x0003 = 3 → 316 = 0.1875 °C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Warm-ups since DTC clear FLEX_WARMUP_CLRConfirmed

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every60 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0xFF = 255 → 255

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Yaw rate signal FLEX_YAW_RATE_SIGConfirmed

  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val5
Range
-6553 to 6553
Unit
Raw value

0x0000 = 0 → 05 = 0

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2016. Supported for 2018.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2016. Supported for 2018.

FLEX

Barometric pressure FLEX_BAROConfirmed

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0362553791
Range
8 to 20 psi
Unit
psi

0x0182 = 386 → 386×0.0362553791 = 13.994576 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Commanded lambda FLEX_CLConfirmed

The ratio of of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0000305176
Range
0 to 1.99
Unit
Number

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Engine coolant temperature FLEX_ECTConfirmed

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-40 to 148.889 °C
Unit
°C

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Octane adjust ratio FLEX_OARConfirmed

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
-1 to 1
Unit
Number

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_AAT

Ambient air temperature sensor voltage FLEX_AAT_VConfirmed

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0048875855
Range
0 to 5 V
Unit
V

0x01AA = 426 → 426×0.0048875855 = 2.082111 V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_AC

Air conditioning compressor pressure FLEX_AC_PConfirmed

  • Service 22DID 0393
  • Module7E0
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.2900754962
Range
0 to 1000 psi
Unit
psi

0x007B = 123 → 123×0.2900754962 = 35.679286 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_ACC

Accelerator pedal position FLEX_ACC_POSConfirmed

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x00 = 0 → 02 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_CL

Closed loop lambda correction FLEX_CL_LCConfirmed

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.99
Unit
Number

0x0000 = 0 → 08192 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_ETC_TRIM

Electronic throttle control learned trim angle FLEX_ETC_TRIM_LEARNEDConfirmed

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_EVAP

Evaporative vapor pressure sensor voltage FLEX_EVAP_VConfirmed

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

0x05BA = 1466 → 14661000 = 1.466 V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_LPFP

Low pressure fuel pump commanded duty cycle FLEX_LPFP_DUTYConfirmed

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

0x2C8C = 11404 → 11404×0.0030517578 = 34.802246 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_MAP

Manifold absolute pressure sensor voltage FLEX_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_RO2

Rear O2 voltage FLEX_RO2_VConfirmed

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

0x0000 = 0 → 01024 = 0 V

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_VCT_EXH

Variable cam timing exhaust cam desired FLEX_VCT_EXH_DESConfirmed

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing exhaust camshaft actual FLEX_VCT_EXH_ACTConfirmed

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing exhaust camshaft error FLEX_VCT_EXH_ERRConfirmed

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing exhaust camshaft solenoid duty cycle FLEX_VCT_EXH_DUTYConfirmed

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×0.0030517578 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

FLEX_VCT_INT

Variable cam timing intake cam desired FLEX_VCT_INT_DESConfirmed

  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing intake camshaft actual FLEX_VCT_INT_ACTConfirmed

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing intake camshaft error FLEX_VCT_INT_ERRConfirmed

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

0x0000 = 0 → 016 = 0 °

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Variable cam timing intake camshaft solenoid duty cycle FLEX_VCT_INT_DUTYConfirmed

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030517578
Range
0 to 100 %
Unit
%

0x0000 = 0 → 0×0.0030517578 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Fuel

Air/fuel ratio FLEX_AIR_FUEL_RATConfirmed

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

0x709B = 28827 → 28827×0.000446787 = 12.879529

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Fuel level FLEX_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×100255 = 0 %

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Movement

Front left wheel speed FLEX_FL_VSSConfirmed

  • Service 22DID 2B07
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Front right wheel speed FLEX_FR_VSSConfirmed

  • Service 22DID 2B06
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Lateral acceleration FLEX_LAT_GConfirmed

  • Service 22DID 2B11
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-1 to 1
Unit
Number

0x0000 = 0 → 050 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Lateral angle, raw count FLEX_LAT_ANGConfirmed

  • Service 22DID 2B0C
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

0x0000 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Navigation speed FLEX_SYNC_GPS_SPDConfirmed

  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 88 to 103 of the reply, 16 bits.

Formula
val×185
Range
0 to 235926 km/h
Unit
km/h

0x000B = 11 → 11×185 = 39.6 km/h

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Rear left wheel speed FLEX_RL_VSSConfirmed

  • Service 22DID 2B09
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Rear right wheel speed FLEX_RR_VSSConfirmed

  • Service 22DID 2B08
  • Module760 → 768
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Vehicle speed FLEX_VSSConfirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2013, 2016. Supported for 2011, 2018.

Vehicle speed, high resolution FLEX_VSS_HDConfirmed

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

0x0000 = 0 → 0128 = 0 km/h

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2016. Supported for 2011, 2013, 2018.

Tires

Front left tire pressure FLEX_TP_FLConfirmed

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x0296 = 662 → 66220 = 33.1 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Front right tire pressure FLEX_TP_FRConfirmed

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276 psi
Unit
psi

0x0296 = 662 → 66220 = 33.1 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Rear left inner tire pressure FLEX_TP_RLIConfirmed

  • Service 22DID 2818
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Rear left tire pressure FLEX_TP_RLConfirmed

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x029C = 668 → 66820 = 33.4 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Rear right inner tire pressure FLEX_TP_RRIConfirmed

  • Service 22DID 2817
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Rear right tire pressure FLEX_TP_RRConfirmed

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 255 psi
Unit
psi

0x0292 = 658 → 65820 = 32.9 psi

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Tire pressure warning indicator FLEX_TPMS_WARNConfirmed

  • Service 22DID 61A5
  • Module720 → 728
  • Every30 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

0b0 = 0 → 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Tire temperature FLEX_TYRE_TConfirmed

  • Service 22DID 280B
  • Module726 → 72E
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x00 = 0 → 0−40 = -40 °C

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Transmission

All-wheel drive clutch diagnostic signal FLEX_AWD_CLU_DIAGNOSTICConfirmed

  • Service 22DID 1E62
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x95 = 149 → 149×2051 = 58.431373 %

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

All-wheel drive clutch, commanded control signal FLEX_AWD_CLU_CMD_CTRL_SIGConfirmed

  • Service 22DID 1E63
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

0x68 = 104 → 104×2051 = 40.784314 %

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.

Axle gear ratio, measured FLEX_AXLE_GEAR_RATIO_MEASConfirmed

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Current gear FLEX_GEARConfirmed

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x01 = 1 → 1

States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Gear ratio, commanded FLEX_PCM_CMD_TRANS_GEAR_RATIOConfirmed

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

0x0000 = 0 → 0×1665535 = 0

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Shift gear FLEX_GEAR_SHFTConfirmed

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x2E = 46 → DRIVE

States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Transmission pressure, commanded FLEX_PCM_CMD_TRANS_MAIN_LINE_PConfirmed

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

0x00C4 = 196 → 196×2 = 392 kPa

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Trips

Odometer FLEX_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x03CC90 = 248976 → 248,976 km

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Odometer, instrument panel FLEX_ODO_V3Confirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 404C
  • Module720 → 728
  • Every5 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

0x25FDA1 = 2489761 → 248976110 = 248,976.1 km

Confirmed for 2016. In testing for 2009 to 2012, 2014 to 2015, 2017 to 2019. Not supported for 2013.

Odometer, power steering module FLEX_ODO_PSCMConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module730 → 738
  • Every30 s
  • Testing for 2009 to 2015, 2017 to 2019

Example reply from a 2016 Ford Flex.

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

0x04195F = 268639 → 268,639 km

Confirmed for 2016. In testing for 2009 to 2015, 2017 to 2019.