Ford B-Max

Parameters

The Ford B-Max has 202 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery age BMAX_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

In testing for 2012 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery age BMAX_12V_AGE

  • Service 22DID 4027
  • Module726 → 72E
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×24
Range
0 to 1572840 h
Unit
h

In testing for 2012 to 2017.

12V battery current BMAX_VEH_BAT_CURRENT

  • Service 22DID 402B
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−127
Range
-127 to 128 A
Unit
A

In testing for 2012 to 2017.

12V battery state of charge BMAX_12V_SOC

  • Service 22DID 4028
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

12V battery temperature BMAX_12V_T

  • Service 22DID 4029
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 100 °C
Unit
°C

In testing for 2012 to 2017.

12V battery voltage BMAX_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402A
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
0 to 18.75 V
Unit
V

In testing for 2012 to 2017.

Battery capacity too low for start/stop BMAX_BAT_CAP_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery current too high for start/stop BMAX_BAT_CURRENT_TOO_HIGH

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery current, predicted BMAX_BAT_CURRENT

  • Service 22DID 4209
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val4
Range
-2097152 to 2097151.75 A
Unit
A

In testing for 2012 to 2017.

Battery quiescent current, low range BMAX_BAT_QUIESCENT

  • Service 22DID 4025
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 mA
Unit
mA

In testing for 2012 to 2017.

Battery refresh cycle in progress for start/stop BMAX_BAT_REFRESH_CYCLE

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery state detection status BMAX_BAT_ST_DETECTION

  • Service 22DID 420A
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Battery state of charge too low for start/stop BMAX_BAT_ST_CHG_TOO_LOW

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery temperature too low for auto stop BMAX_BAT_T_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery voltage BMAX_BAT_V

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.9375 V
Unit
V

In testing for 2012 to 2017.

Battery voltage too low for auto restart BMAX_BAT_V_TOO_LOW_AUTO

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery voltage too low for cold cranking capability BMAX_BAT_V_TOO_LOW_COLD

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Battery voltage too low for start/stop BMAX_BAT_V_TOO_LOW_START

  • Service 22DID 41A9
  • Module726 → 72E
  • Every5 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Charge air temperature BMAX_CHG_AIR_T

  • Service 22DID 051C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2017.

Commanded generator voltage BMAX_CMD_GEN_V

  • Service 22DID 0304
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000488
Range
0 to 16 V
Unit
V

In testing for 2012 to 2017.

Normalized cumulative charge when ignition is on BMAX_NORM_CUM_CHG_IGN_ON

  • Service 22DID 401E
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2012 to 2017.

Normalized cumulative discharge from battery with engine off BMAX_NORM_CUM_DCHG_BAT_OFF

  • Service 22DID 4026
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2012 to 2017.

Normalized cumulative discharge from battery with engine on BMAX_NORM_CUM_DCHG_BAT_ON

  • Service 22DID 4021
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5
Unit
Number

In testing for 2012 to 2017.

Second battery current BMAX_VEH_BAT_B_CURRENT

  • Service 22DID 423C
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1024 to 1023.96 A
Unit
A

In testing for 2012 to 2017.

Second battery voltage BMAX_VEH_BAT_B_V

  • Service 22DID 41E8
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val20+6
Range
6 to 18.75 V
Unit
V

In testing for 2012 to 2017.

Climate

A/C compressor pressure BMAX_AC_P

  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×245251845473
Range
0 to 1000 psi
Unit
psi

In testing for 2012 to 2017.

A/C compressor pressure sensor voltage BMAX_AC_P_SENS_V

  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

A/C compressor, state BMAX_AC_STATE

  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

A/C refrigerant pressure BMAX_PCM_A_C_REFRIG_P

  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2012 to 2017.

Ambient temperature sensor voltage BMAX_AAT_V

  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Ambient temperature, alternate BMAX_AAT_ALT

  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2012 to 2017.

Cruise control

Target speed BMAX_CC_TGT_VSS

The speed of the vehicle ahead of you.

  • Service 22DID A224
  • Module764 → 76C
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×3.610
Range
-736 to 736 km/h
Unit
km/h

In testing for 2012 to 2017.

Doors

Driver door ajar BMAX_DRIVER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Hood ajar? BMAX_HOOD_OPEN

  • Service 22DID C154
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Lock status BMAX_CENTRAL_LOCK_STATUS

  • Service 22DID C259
  • Module726 → 72E
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNLOCKEDUnlocked
2LOCKEDLocked

In testing for 2012 to 2017.

Passenger door ajar? BMAX_PASSENGER_DOOR_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Rear left door ajar? BMAX_RLD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Rear right door ajar? BMAX_RRD_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Trunk ajar? BMAX_TRUNK_OPEN

  • Service 22DID C150
  • Module726 → 72E
  • Every3 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2012 to 2017.

Engine

Accelerator position BMAX_ACC_POS

  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Actual engine percent torque BMAX_PCM_ACT_ENG_PCT_TRQ

  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−125
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Air conditioning pressure BMAX_AC_P_7E0

  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.156863
Range
0 to 3100 kPa
Unit
kPa

In testing for 2012 to 2017.

Barometric pressure BMAX_BARO

  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×61516963
Range
8 to 20 psi
Unit
psi

In testing for 2012 to 2017.

Barometric pressure BMAX_BAROMETRIC_P

  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×33863980000
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2012 to 2017.

Barometric pressure sensor voltage BMAX_BARO_V

  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Battery current BMAX_BAT_CURRENT_726

  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−511.7
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2012 to 2017.

Boost BMAX_BOOST

  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2012 to 2017.

Bypass valve BMAX_BPV_OPEN

  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val255
Range
0 to 1
Unit
Number

In testing for 2012 to 2017.

Camshaft position error, exhaust BMAX_VCT_EXH_ERR

  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2012 to 2017.

Camshaft position error, intake BMAX_VCT_INT_ERR

  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-50 to 50 °
Unit
°

In testing for 2012 to 2017.

Camshaft position, exhaust actual BMAX_VCT_EXH_ACT

  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 50 °
Unit
°

In testing for 2012 to 2017.

Camshaft position, exhaust desired BMAX_VCT_EXH_DES

  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2047 to 2047 °
Unit
°

In testing for 2012 to 2017.

Camshaft position, intake actual BMAX_VCT_INT_ACT

  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.93 °
Unit
°

In testing for 2012 to 2017.

Camshaft solenoid duty cycle, exhaust BMAX_VCT_EXH_DUTY

  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Camshaft solenoid duty cycle, intake BMAX_VCT_INT_DUTY

  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Catalyst temperature BMAX_CAT_TEMP

  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2017.

Charge air temperature BMAX_CAT

  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64−40
Range
-40 to 189 °C
Unit
°C

In testing for 2012 to 2017.

Charge air temperature sensor voltage BMAX_CAT_SENS_V

  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Commanded generator duty BMAX_CMD_GEN_DUTY

  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Coolant temperature BMAX_ECT

  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2012 to 2017.

Cylinder 1 misfire count BMAX_MIS_CNT_1

  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 2 misfire count BMAX_MIS_CNT_2

  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 3 misfire count BMAX_MIS_CNT_3

  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 4 misfire count BMAX_MIS_CNT_4

  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 5 misfire count BMAX_MIS_CNT_5

  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 6 misfire count BMAX_MIS_CNT_6

  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 7 misfire count BMAX_MIS_CNT_7

  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder 8 misfire count BMAX_MIS_CNT_8

  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Cylinder head temperature BMAX_CYL_HEAD_T

  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2017.

Cylinder head temperature BMAX_CYL_HEAD_T_7E0

  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2012 to 2017.

Cylinder head temperature BMAX_PCM_CYL_HEAD_T_CORR

  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2012 to 2017.

Cylinder head temperature, alternate BMAX_CYL_HEAD_T_ALT

  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2811000
Range
0 to 18415 °F
Unit
°F

In testing for 2012 to 2017.

Cylinder head temperature, sensor 2 BMAX_PCM_CYL_HEAD_T_SENS_2_RAW

  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

In testing for 2012 to 2017.

Distance since DTC clear BMAX_DIST_DTC_CLR

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012 to 2017.

Distance with MIL BMAX_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012 to 2017.

Engine load BMAX_ENG_LOAD_PCT

  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Engine load, actual BMAX_ENG_LOAD_ACT

  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100255
Range
0 to 25700 %
Unit
%

In testing for 2012 to 2017.

Engine oil temperature BMAX_EOT

  • Service 22DID 1310
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−40
Range
-40 to 615 °C
Unit
°C

In testing for 2012 to 2017.

Engine reference torque BMAX_PCM_ENG_REFERENCE_TRQ

  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2012 to 2017.

Engine run time BMAX_ERT

  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2012 to 2017.

Engine speed BMAX_RPM

  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2012 to 2017.

Evaporative pressure sensor, raw count BMAX_EVAP_RAW

  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Evaporative purge BMAX_EVAP_PURGE_CMD

  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Exhaust gas recirculation BMAX_EGR

  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Exhaust gas recirculation duty cycle BMAX_EGR_DUTY

  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Exhaust gas temperature 1 BMAX_EXH_GAS_T_1

  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2012 to 2017.

Exhaust gas temperature 2 BMAX_EXH_GAS_T_2

  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5
Range
0 to 1275 °C
Unit
°C

In testing for 2012 to 2017.

Fuel pressure sensor voltage, low BMAX_LPFP_SENS_V

  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Fuel pressure, low actual BMAX_LPFP_ACT

  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10000137892
Range
0 to 200 psi
Unit
psi

In testing for 2012 to 2017.

Fuel pressure, low desired BMAX_LPFP_DES

  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4351000
Range
0 to 110 psi
Unit
psi

In testing for 2012 to 2017.

Fuel pump duty cycle, low pressure BMAX_LPFP_DUTY

  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×258192
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Fuel pump pulse width, bank 2 BMAX_FUEL_PMP_WIDTH_BANK_2

  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107
Unit
Number

In testing for 2012 to 2017.

Fuel rail pressure, desired BMAX_HPFP_DES

  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 kPa
Unit
kPa

In testing for 2012 to 2017.

Fuel rail sensor voltage, high pressure BMAX_HPFP_V

  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Fuel trim, long term BMAX_LTFT

  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2012 to 2017.

Fuel trim, short term BMAX_STFT

  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

In testing for 2012 to 2017.

Generator control BMAX_GEN_CTRL

  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.003052
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Generator current BMAX_GEN_CURRENT

  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×78150000
Range
-511.8361 to 511.8205 A
Unit
A

In testing for 2012 to 2017.

Grill shutter duty cycle BMAX_GRILL_SHUT_DC

  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Grill shutter position BMAX_GRILL_SHUTTER_POS

  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Ignition correction, cylinder 1 BMAX_IGN_CORR_CYL1

  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2012 to 2017.

Ignition timing, cylinder 1 BMAX_IGN_TIM_CYL1

  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-80 to 80 °
Unit
°

In testing for 2012 to 2017.

In car temperature BMAX_CAR_T

  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8
Range
0 to 31.875 °C
Unit
°C

In testing for 2012 to 2017.

Injection mode BMAX_INJ_MODE

  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 7
Unit
Number

In testing for 2012 to 2017.

Injector impulse width BMAX_INJ_IMPULSE_WIDTH

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000022
Range
0 to 0.05 s
Unit
s

In testing for 2012 to 2017.

Intake air temperature 2 BMAX_IAT_2

  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×59−17.777778
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2012 to 2017.

Intake temperature fault BMAX_IAT_FAULT

  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Intake temperature sensor voltage BMAX_IAT_SENS_V

  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51023
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Intake temperature, alternate BMAX_IAT_ALT2

  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2017.

Knock counter, cylinder 1 BMAX_PCM_CYL_1_KNK_COMB_PERF_CNT

  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock counter, cylinder 2 BMAX_PCM_CYL_2_KNK_COMB_PERF_CNT

  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock counter, cylinder 3 BMAX_PCM_CYL_3_KNK_COMB_PERF_CNT

  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock counter, cylinder 4 BMAX_PCM_CYL_4_KNK_COMB_PERF_CNT

  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock counter, cylinder 5 BMAX_PCM_CYL_5_KNK_COMB_PERF_CNT

  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock counter, cylinder 6 BMAX_PCM_CYL_6_KNK_COMB_PERF_CNT

  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Knock sensor, 1 BMAX_KS1_RAW

  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Knock sensor, 2 BMAX_KS2_RAW

  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Lambda correction BMAX_CL_LC

  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8192
Range
-4 to 3.9
Unit
Number

In testing for 2012 to 2017.

Lambda, commanded BMAX_CL

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.9999
Unit
Number

In testing for 2012 to 2017.

Manifold absolute pressure, high resolution BMAX_MAP_HIRES

  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 kPa
Unit
kPa

In testing for 2012 to 2017.

Manifold pressure BMAX_MAP

  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1000068947
Range
0 to 36 psi
Unit
psi

In testing for 2012 to 2017.

Manifold pressure sensor voltage BMAX_MAP_V

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Manifold temperature BMAX_MCT

  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 148.889 °C
Unit
°C

In testing for 2012 to 2017.

Misfire acceleration, cylinder 1 BMAX_PCM_MISF_ACCEL_CYL1_NORM

  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire acceleration, cylinder 2 BMAX_PCM_MISF_ACCEL_CYL2_NORM

  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire acceleration, cylinder 3 BMAX_PCM_MISF_ACCEL_CYL3_NORM

  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire acceleration, cylinder 4 BMAX_PCM_MISF_ACCEL_CYL4_NORM

  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire acceleration, cylinder 5 BMAX_PCM_MISF_ACCEL_CYL5_NORM

  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire acceleration, cylinder 6 BMAX_PCM_MISF_ACCEL_CYL6_NORM

  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val64
Range
-2 to 1.98
Unit
Number

In testing for 2012 to 2017.

Misfire events, latest cycle BMAX_PCM_MISF_EVENTS_LATEST_CYC

  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2012 to 2017.

O2 sensor voltage, rear BMAX_RO2_V

  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 1 V
Unit
V

In testing for 2012 to 2017.

Octane adjustment BMAX_OAR

  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16384
Range
0 to 1
Unit
Number

In testing for 2012 to 2017.

Oil life remaining BMAX_PCM_ENG_OIL_LIFE_REM

  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Oil pressure BMAX_PCM_ENG_EOP_RAW

  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 2012 to 2017.

Sump oil temperature measured BMAX_SUMP_OIL_T_MEAS

  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2017.

Throttle angle, actual BMAX_ETC_ANG_ACT

  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2012 to 2017.

Throttle angle, desired BMAX_ETC_ANG_DES

  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.99 °
Unit
°

In testing for 2012 to 2017.

Throttle control trim angle, learned BMAX_ETC_TRIM_LRN

  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val512
Range
-64 to 63.9 °
Unit
°

In testing for 2012 to 2017.

Throttle inlet pressure BMAX_TIP_ABS

  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 60 psi
Unit
psi

In testing for 2012 to 2017.

Throttle inlet pressure sensor voltage BMAX_TIP_V

  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×51024
Range
0 to 5 V
Unit
V

In testing for 2012 to 2017.

Throttle inlet pressure, desired BMAX_TIP_DES_ABS

  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3733441
Range
0 to 72.5 psi
Unit
psi

In testing for 2012 to 2017.

Time since last oil change BMAX_TIME_SINCE_OIL

  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20013107
Range
0 to 1000
Unit
Raw value

In testing for 2012 to 2017.

Torque converter slip BMAX_TQ_CONV_SLIP

  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.638538424
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2012 to 2017.

Torque into torque converter BMAX_TQ_INTO_TQ_CONV

  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1.35581795
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2012 to 2017.

Torque into torque converter BMAX_TQ_INTO_TQ_CONV_7E0

  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2012 to 2017.

Torque request BMAX_TRQ_CTRL_REQ

  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Total misfire count BMAX_TOT_MIS_CNT

  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2017.

Transfer case fluid temperature BMAX_TRANSFER_CASE_FLUID_T

  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2012 to 2017.

Transmission fluid temperature, variant 1 BMAX_ATF_T_VAR_1

  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val8
Range
0 to 8191 °F
Unit
°F

In testing for 2012 to 2017.

Transmission fluid temperature, variant 2 BMAX_ATF_T_VAR_2

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1674
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2012 to 2017.

Transmission fluid temperature, variant 5 BMAX_ATF_T_VAR_5

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E3F
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2012 to 2017.

Transmission fluid temperature, variant 6 BMAX_ATF_T_VAR_6

  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2012 to 2017.

Transmission oil temperature BMAX_TOT_7E0

  • Service 22DID 1E1C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-500 to 500 °C
Unit
°C

In testing for 2012 to 2017.

Turbo boost BMAX_TURBO_BOOST

  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2012 to 2017.

Turbo inlet pressure BMAX_TURBO_INLET_P

  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2012 to 2017.

Warm-ups since DTC clear BMAX_WARMUP_CLR

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2017.

Wastegate control BMAX_WASTEGATE_CTRL

  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×76350000
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Wastegate duty cycle BMAX_WGDC

  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10032768
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Fuel

Air/fuel ratio BMAX_AIR_FUEL_RAT

  • Service 22DID F434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000446787
Range
0 to 29.2801
Unit
Number

In testing for 2012 to 2017.

Engine fuel rate BMAX_ENG_FUEL_RATE

  • Service 22DID F45E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L
Unit
L

In testing for 2012 to 2017.

Fuel injection impulse width BMAX_FUEL_INJ_IMPULSE

  • Service 22DID 168B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val125000
Range
0 to 0.1 s
Unit
s

In testing for 2012 to 2017.

Fuel level BMAX_FLI_16C1

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0030518509
Range
0 to 200 %
Unit
%

In testing for 2012 to 2017.

Fuel level BMAX_FLI_7E0

Pelican can show this parameter as the fuel tank level.

  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Fuel pump duty cycle BMAX_FUEL_PMP_DUTY

  • Service 22DID 1672
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2532
Range
0 to 199.2187 %
Unit
%

In testing for 2012 to 2017.

Fuel tank level BMAX_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 6185
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Fuel tank pressure BMAX_FUEL_TANK_P

  • Service 22DID 1639
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val6.901311249
Range
0 to 9496.0214 psi
Unit
psi

In testing for 2012 to 2017.

Fuel temperature BMAX_FUEL_T

  • Service 22DID 0522
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2017.

Lights

Exterior lighting state BMAX_EXTERIOR_LIGHT_STATE

  • Service 22DID 407E
  • Module726 → 72E
  • Every1 s
  • Testing

Bit 0 of the reply.

Unit
Named states
States
Raw valueState
00
2161

In testing for 2012 to 2017.

High beam status BMAX_HIGH_BEAM

  • Service 22DID 7151
  • Module726 → 72E
  • Every4 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 2
Unit
Off or on

In testing for 2012 to 2017.

Movement

Accelerator pedal position BMAX_ACCEL_PEDAL_POS

  • Service 22DID 09D4
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 %
Unit
%

In testing for 2012 to 2017.

Fan speed sensor BMAX_FAN_SPD_SENS

  • Service 22DID 099F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2012 to 2017.

Fan speed, desired BMAX_FAN_SPD_DES

  • Service 22DID 03B9
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×4013107
Range
0 to 100 %
Unit
%

In testing for 2012 to 2017.

Vehicle speed BMAX_VSS

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2012 to 2017.

Vehicle speed, high resolution BMAX_VSS_HD

  • Service 22DID 1505
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 200 km/h
Unit
km/h

In testing for 2012 to 2017.

Tires

Front left tire pressure BMAX_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 2813
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Front right tire pressure BMAX_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 2814
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear left outer tire pressure BMAX_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2816
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Rear right outer tire pressure BMAX_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2815
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 150 psi
Unit
psi

Tire pressure warning indicator BMAX_TPMS_WARN

  • Service 22DID 61A5
  • Module720 → 728
  • Every30 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2017.

Transmission

Axle gear ratio, measured BMAX_AXLE_GEAR_RATIO_MEAS

  • Service 22DID 1E16
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 10
Unit
Number

In testing for 2012 to 2017.

Converter speed ratio BMAX_CONV_SPD_RAT

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×582
Range
0 to 3996.0365
Unit
Number

In testing for 2012 to 2017.

Current gear BMAX_GEAR

The automatic transmission gear.

  • Service 22DID 1E12
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear
88Eighth gear
99Ninth gear
1010Tenth gear

In testing for 2012 to 2017.

Gear ratio, commanded BMAX_PCM_CMD_TRANS_GEAR_RATIO

  • Service 22DID 1E19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2012 to 2017.

Gear, engaged BMAX_GEAR_ENG

  • Service 22DID 1E1F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2012 to 2017.

Gear, shift BMAX_GEAR_SHFT

  • Service 22DID 1E23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
10MANUALManual
46DRIVEDrive
50NEUTRALNeutral
60REVERSEReverse
70PARKPark

In testing for 2012 to 2017.

Torque converter line pressure BMAX_TQ_CONV_LINE_P

  • Service 22DID 11C0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1723695000
Range
0 to 8790.819 kPa
Unit
kPa

In testing for 2012 to 2017.

Torque into torque converter, variant 2 BMAX_TQ_INTO_TQ_CONV_VAR_2

  • Service 22DID 163A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.2711635897
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2012 to 2017.

Transmission gear BMAX_TRANS_GEAR

  • Service 22DID 11B3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2012 to 2017.

Transmission gear BMAX_TRANS_GEAR_7E1

  • Service 22DID 11B3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5
Unit
Number

In testing for 2012 to 2017.

Transmission gear ratio BMAX_TRANS_GEAR_RAT

  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×15.7480315
Range
0 to 4015.748
Unit
Number

In testing for 2012 to 2017.

Transmission odometer BMAX_TRANS_ODO

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2012 to 2017.

Transmission output shaft speed BMAX_TRANS_OUTPUT_SHFT

  • Service 22DID 11B5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 rpm
Unit
rpm

In testing for 2012 to 2017.

Transmission pressure, commanded BMAX_PCM_CMD_TRANS_MAIN_LINE_P

  • Service 22DID 1E1A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×2
Range
-65536 to 65534 kPa
Unit
kPa

In testing for 2012 to 2017.

Transmission temperature BMAX_TT

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1E1C
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-300 to 300 °C
Unit
°C

In testing for 2012 to 2017.

Trips

Distance since last oil change BMAX_DIST_SINCE_OIL

  • Service 22DID 0542
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012 to 2017.

Distance to empty, calculated BMAX_DTE

Pelican can show this parameter as the fuel range.

  • Service 22DID 4194
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2012 to 2017.

Distance to empty, displayed BMAX_DTE_DISP

Pelican can show this parameter as the fuel range.

  • Service 22DID 4195
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2012 to 2017.

Odometer BMAX_ODO

  • Service 22DID 404C
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2012 to 2017.

Odometer BMAX_ODO_720

  • Service 22DID 6180
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2012 to 2017.

Odometer BMAX_ODO_7E0

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2012 to 2017.

Odometer, instrument panel BMAX_ODO_726

Pelican can show this parameter as the odometer.

  • Service 22DID DD01
  • Module726 → 72E
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2012 to 2017.

Trip distance BMAX_ODO_TRIP

  • Service 22DID DD01
  • Module720 → 728
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val10
Range
0 to 1677721 km
Unit
km

In testing for 2012 to 2017.

Vehicle odometer BMAX_PCM_VEH_ODO

  • Service 22DID F4A6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729.5 km
Unit
km

In testing for 2012 to 2017.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.