Daihatsu Hijet

Parameters

The Daihatsu Hijet has 306 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level, volume HIJET_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

0x14 = 20 → 20×5003785 = 2.642008 gal

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

+BM voltage HIJET_BM_V

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2014 to 2026.

Battery current HIJET_BAT_CURRENT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5013107−125
Range
-125 to 124.9 A
Unit
A

In testing for 2014 to 2026.

Battery temperature HIJET_BAT_T

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2014 to 2026.

Battery voltage HIJET_BAT_V

  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2014 to 2026.

Battery voltage HIJET_BATTERY_VOLTAGE_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2014 to 2026.

Charge contactor current HIJET_SCC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Main connector solenoid current HIJET_SMC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Main relay a, solenoid current HIJET_SLA_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Main relay r solenoid current HIJET_SLR_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Output speed sensor voltage HIJET_NOUT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2014 to 2026.

Regenerative braking cooperation HIJET_REGEN_COOPERATION

  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Regenerative operation HIJET_FR_REGEN_OPERATION

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2014 to 2026.

Regenerative request HIJET_FR_REGEN_REQUEST

  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2014 to 2026.

Relay control solenoid current HIJET_SRC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Service contactor solenoid current HIJET_SSC_SOLENOID_CURRENT

  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2026.

Turbine speed sensor voltage HIJET_NT_SENS_V

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 V
Unit
V

In testing for 2014 to 2026.

Climate

Communication with air conditioner HIJET_COMM_WITH_AIR_CONDITIONER

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Communication with HV HIJET_COMMUNICATION_WITH_HV

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Communication with valvematic HIJET_COMM_WITH_VALVEMATIC_COMM

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Control

A/C compressor HIJET_A_C_COMPRESSOR

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 64 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Accelerator sensor voltage, 1 HIJET_ACCEL_SENS_1_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Accelerator sensor voltage, 2 HIJET_ACCEL_SENS_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Anti-lock brake warning light HIJET_ABS_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Brake warning light HIJET_BRAKE_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Buzzer HIJET_BUZZER

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Communication with brake HIJET_COMMUNICATION_WITH_BRAKE

  • Service 21PID 24
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Cruise control live brake cancel HIJET_CRUISE_CONTROL_LIVE_BRAKE_CANCEL_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Electrical load signal 1 HIJET_ELECTRICAL_LOAD_SIGNAL_1

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Electrical load signal 2 HIJET_ELECTRICAL_LOAD_SIGNAL_2

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Electronically controlled brake warning light HIJET_ECB_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Ignition trigger count HIJET_IGNITION_TRIG_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2026.

Key remind sound HIJET_KEY_REMIND_SOUND

  • Service 21PID A1
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Main idle HIJET_MAIN_IDLE_SW

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Neutral position HIJET_NEUTRAL_POSITION_SW_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 53 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Parking brake HIJET_PARKING_BRAKE_SW

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Pattern switch HIJET_PATTERN_SWITCH_PWR_M

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Power steering HIJET_POWER_STEERING_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Reservoir warning HIJET_RESERVOIR_WARNING_SW

  • Service 21PID 1D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Shift SW status, drive HIJET_SHIFT_SW_STATUS_D_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Shift SW status, neutral HIJET_SHIFT_SW_STATUS_N_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Shift SW status, parking HIJET_SHIFT_SW_STATUS_P_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Shift SW status, reverse HIJET_SHIFT_SW_STATUS_R_RANGE

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Slip indicator light HIJET_SLIP_WARN

  • Service 21PID 3D
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Sports mode selection HIJET_SPORTS_MODE_SELECTION_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 32 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Sports shift down HIJET_SPORTS_SHIFT_DOWN_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Sports shift up HIJET_SPORTS_SHIFT_UP_SW

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Starter control HIJET_STARTER_CONTROL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Starter signal HIJET_STARTER_SIGNAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Steering wheel angle HIJET_STEER_ANGLEConfirmed

Positive = counter-clockwise, negative = clockwise.

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 24 to 39 of the reply, 16 bits.

Formula
val10−3276.8
Range
-3276 to 3276 °
Unit
°

0x6F06 = 28422 → 2842210−3276.8 = -434.6 °

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

TC HIJET_TC_TERMINAL

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Traction control, brake status HIJET_TRC_TRAC__BRAKE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Cruise control

Cruise control speed HIJET_CC_SConfirmed

  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

0x00 = 0 → 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Details

Inspection mode HIJET_INSPECTION_MODE

  • Service 21PID A6
  • Module7B0 → 7B8
  • Every60 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

DTCs

2nd air monitor available? HIJET_2ND_AIR_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

2nd air monitor incomplete? HIJET_2ND_AIR_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

A/C monitor available? HIJET_A_C_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

A/C monitor incomplete? HIJET_A_C_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Catalyst monitor available? HIJET_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Catalyst monitor incomplete? HIJET_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Complete parts monitor available? HIJET_COMPLETE_PARTS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

EGR/VVT monitor available? HIJET_EGR_VVT_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

EGR/VVT monitor incomplete? HIJET_EGR_VVT_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

EVAP monitor available? HIJET_EVAP_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

EVAP monitor_icmpl HIJET_EVAP_MONITOR_ICMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Fuel system monitor available? HIJET_FUEL_SYSTEM_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Heated catalyst monitor available? HIJET_HEATED_CATALYST_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Heated catalyst monitor incomplete? HIJET_HEATED_CATALYST_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

MIL HIJET_MIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

MIL ON run distance HIJET_MILON_RUN_DISTANCE

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2014 to 2026.

Misfire monitor available? HIJET_MISFIRE_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Number of emission DTC HIJET_NUMBER_OF_EMISSION_DTC

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

In testing for 2014 to 2026.

O2S heater monitor available? HIJET_O2S_A_FS_HEATER_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

O2S heater monitor incomplete? HIJET_O2S_A_FS_HEATER_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

O2S monitor available? HIJET_O2S_A_FS_MONITOR_AVAIL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

O2S monitor incomplete? HIJET_O2S_A_FS_MONITOR_INCMPL

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Running time from MIL ON HIJET_RUNNING_TIME_FROM_MIL_ON

  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2014 to 2026.

Electrical

B+ battery voltage HIJET_BATTERY_VOLTAGE_7C0

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1021
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 20 V
Unit
V

In testing for 2014 to 2026.

Engine

A/F heater duty bank 1 sensor 1 HIJET_F_HEATER_DUTY_B1S1

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2014 to 2026.

A/F test results 1, incomplete HIJET_F_TEST_RESULTS_1

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Accessory relay on HIJET_ACC_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Accumulator open HIJET_ACCUMULATOR_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Acoustic control induction system vacuum switching valve on HIJET_ACIS_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Actual engine torque HIJET_ACT_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val−32768
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2014 to 2026.

Actuator power supply on HIJET_ACTUATOR_POWER_SUP_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Air conditioning compressor HIJET_AC_COMP

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Air-fuel equivalence ratio, bank 1 sensor 1 HIJET_AF_LAMBDA_B1S1

Pelican can show this parameter as the O2 lambda.

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2014 to 2026.

Air-fuel sensor current, bank 1 sensor 1 HIJET_AFS_I_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.99 mA
Unit
mA

In testing for 2014 to 2026.

Air-fuel sensor voltage, bank 1 sensor 1 HIJET_AFS_V_B1S1

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×7.9965535
Range
0 to 7.99 V
Unit
V

In testing for 2014 to 2026.

Alt voltage - active test HIJET_ALT_VOL_ACTIVE_TEST

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2014 to 2026.

Alt voltage - non active test HIJET_ALT_VOL_NON_ACTIVE

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2014 to 2026.

Alternator output duty HIJET_ALTERNATOR_OUTPUT

  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2014 to 2026.

Atmospheric pressure HIJET_ATMOSPHERE_PRESSURE

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2026.

Calculated load HIJET_CALCULATED_LOAD_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Catalyst temperature, bank 1 sensor 1 HIJET_CAT_T_B1S1

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2014 to 2026.

Catalyst temperature, bank 1 sensor 2 HIJET_CAT_T_B1S2

  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2014 to 2026.

Catalyst temperature, bank 1 sensor 2, variant 2 HIJET_CAT_T_B1S2_V2

  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2014 to 2026.

Check mode on HIJET_CHECK_MODE_ON

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Closed throttle position switch on HIJET_CLOSED_THROTTLE_POS_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Codes, include history HIJET_CODES_INCLUDE

  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Continuously variable transmission learning complete HIJET_CVT_LEARNED

  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2014 to 2026.

Continuously variable transmission oil pressure HIJET_CVT_OIL_P

  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×40
Range
0 to 10200 kPa
Unit
kPa

In testing for 2014 to 2026.

Coolant temperature HIJET_COOLANT_TEMP_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Cruise control on HIJET_CRUISE_CTRL_ON

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Cylinder number HIJET_CYLINDER_NUMBER

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Destination HIJET_DESTINATION

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Dist battery cable disconnect HIJET_DIST_BATT_CABLE

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2014 to 2026.

Electric fan motor on HIJET_ELEC_FAN_MOTOR_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Engine coolant temperature HIJET_ECT_7C0

Pelican can show this parameter as the engine coolant temperature.

  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2014 to 2026.

Engine independent HIJET_ENG_INDEPENDENT

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Engine independent control HIJET_ENG_INDEPENDENT_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Engine oil temperature HIJET_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Engine run time HIJET_ENGINE_RUN_TIME

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2014 to 2026.

Engine run time, up to 255 sec. only HIJET_ENG_RUN_TIME_UP_255

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2014 to 2026.

Engine speed HIJET_ENGINE_SPEED_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2014 to 2026.

Engine stall control FB flow HIJET_ENG_STALL_CTRL_FB

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×54096−40
Range
-40 to 39.99
Unit
Number

In testing for 2014 to 2026.

Evaporative purge duty HIJET_EVAP_PURGE_DUTY_7E0

  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Evaporative purge flow HIJET_EVAP_PURGE_FLOW

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.99 %
Unit
%

In testing for 2014 to 2026.

Evaporative purge vacuum switching valve on HIJET_EVAP_PURGE_VSV_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Exhaust gas recirculation step position HIJET_EGR_STEP_POSITION

  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Exhaust gas recirculation temperature HIJET_EGR_T

  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5385
Range
0 to 159 °C
Unit
°C

In testing for 2014 to 2026.

Exhaust gas recirculation valve step HIJET_EGR_STEP

  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Fuel cut for engine stop request HIJET_F_C_ENG_STOP_REQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Fuel cut TAU on HIJET_FC_TAU_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

G sensor calibration, complete HIJET_G_SENS_CALIBRATION

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

G sensor learning value HIJET_G_SENS_LEARNING

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val×54096
Range
0 to 79.998 V
Unit
V

In testing for 2014 to 2026.

Hydraulic valve, communication open HIJET_HV_COMM_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Idle control HIJET_IDLE_CTRL

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Idle spark advance control 1 HIJET_IDLE_SPARK_ADVN_CTRL_1

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2014 to 2026.

Idle spark advance control 2 HIJET_IDLE_SPARK_ADVN_CTRL_2

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2014 to 2026.

Idle spark advance control 3 HIJET_IDLE_SPARK_ADVN_CTRL_3

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2014 to 2026.

Idle spark advance control 4 HIJET_IDLE_SPARK_ADVN_CTRL_4

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val16
Range
0 to 15.93 °
Unit
°

In testing for 2014 to 2026.

Idle speed control learning HIJET_IDLE_SPD_CTRL

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Idle speed control learning value, l/s HIJET_IDLE_SPD_CTRL_L_S

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val×0.0012206912
Range
0 to 79.99
Unit
Number

In testing for 2014 to 2026.

IG OFF elapsed time HIJET_IG_OFF_ELAPSED_TIME

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val×10
Range
0 to 655350 min
Unit
min

In testing for 2014 to 2026.

Ignition advance HIJET_SPARKADV_21

  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2014 to 2026.

Ignition timing advance HIJET_IGN_ADVANCE

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2−64
Range
-64 to 63.5 °
Unit
°

In testing for 2014 to 2026.

Immobilizer communication on HIJET_IMMOBILIZER_ON

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Initial engine coolant temperature HIJET_INITIAL_ECT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×531850−40
Range
-40 to 119.3
Unit
Number

In testing for 2014 to 2026.

Initial intake air temperature HIJET_INITIAL_IAT

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×58−40
Range
-40 to 119 °C
Unit
°C

In testing for 2014 to 2026.

Injection duration for cylinder 1 HIJET_INJ_DUR_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2026.

Injection volume per 10 injections, cylinder 1 HIJET_INJ_VOL_CYL_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32000000
Range
0 to 0.002 L
Unit
L

In testing for 2014 to 2026.

Injector pulse width HIJET_INJ_PW

  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1631275
Range
0 to 32.6 ms
Unit
ms

In testing for 2014 to 2026.

Injector pulse width HIJET_INJ_WIDTH

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2014 to 2026.

Input shaft speed HIJET_SPD_NIN

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2014 to 2026.

Intake air temperature HIJET_IAT_21

  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Intake air temperature HIJET_INTAKE_AIR_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Judge time engine ignition HIJET_JUDGE_TIME_ENG_IGN

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2014 to 2026.

Judge time engine output HIJET_JUDGE_TIME_ENG

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2014 to 2026.

Knock adjust HIJET_KNOCK_ADJUST

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2014 to 2026.

Knock adjust HIJET_KNOCK_ADJUST_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2014 to 2026.

Knock correct learn value HIJET_KNOCK_CORRECT_LEARN

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val32−1024
Range
-1024 to 1023 °
Unit
°

In testing for 2014 to 2026.

Knock feedback HIJET_KNOCK_FEEDBACK

  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×204865535−64
Range
-64 to 1984 °
Unit
°

In testing for 2014 to 2026.

Knock feedback HIJET_KNOCK_FEEDBACK_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×204865535−1024
Range
-1024 to 1024 °
Unit
°

In testing for 2014 to 2026.

Long term fuel trim, bank 1 HIJET_LONG_FT_B1

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2014 to 2026.

Long term fuel trim, bank 2 HIJET_LONG_FT_B2

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2014 to 2026.

Long-term fuel trim, bank 1 HIJET_LTFT1_21

  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.7809803922−100
Range
-100 to 99.15 %
Unit
%

In testing for 2014 to 2026.

Manifold absolute pressure HIJET_MAP_7E0

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2026.

Mass air flow HIJET_MAF_21

  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 g/s
Unit
g/s

In testing for 2014 to 2026.

Mass air flow HIJET_MAF_7E0

Pelican can show this parameter as the mass air flow.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2014 to 2026.

Master cylinder open HIJET_MASTER_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Misfire RPM HIJET_MISFIRE_RPM_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2014 to 2026.

Misfire test result, incomplete HIJET_MIS_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Model year HIJET_MODEL_YEAR

  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val+1900
Range
1900 to 2155
Unit
Number

In testing for 2014 to 2026.

O2 heater b1s2_active HIJET_O2_HEATER_B1S2

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

O2 heater current val bank 1 sensor 2 HIJET_O2_HEATER_CURR_VAL

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val13107
Range
0 to 4.999 A
Unit
A

In testing for 2014 to 2026.

Open side malfunction on HIJET_OPEN_SIDE_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Output shaft speed HIJET_SPD_NOUT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2014 to 2026.

OXS1, A/FS2 test result, incomplete HIJET_OXS1_FS2_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Oxygen sensor voltage, bank 1 sensor 1 HIJET_O2S11_V

  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.0049960784
Range
0 to 1.27 V
Unit
V

In testing for 2014 to 2026.

Oxygen sensor voltage, bank 1 sensor 2 HIJET_O2S_B1S2

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val×51000
Range
0 to 1.275 V
Unit
V

In testing for 2014 to 2026.

Purge cut vacuum switching valve duty HIJET_PURGE_CUT_VSV_DUTY

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2014 to 2026.

Racing operation HIJET_RACING_OPERATION

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Request engine run time HIJET_REQ_ENG_RUN_TIME

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 s
Unit
s

In testing for 2014 to 2026.

Request warm-up HIJET_REQ_WARM_UP

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Requested engine torque HIJET_REQ_ENG_TQ

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383
Unit
Number

In testing for 2014 to 2026.

Short term fuel trim, bank 1 HIJET_SHORT_FT_B1

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2014 to 2026.

Short term fuel trim, bank 2 HIJET_SHORT_FT_B2

Pelican can show this parameter as the short term fuel trim.

  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×200256−100
Range
-100 to 99.21 %
Unit
%

In testing for 2014 to 2026.

Starter relay on HIJET_STARTER_RELAY_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Stroke open HIJET_STROKE_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

System guard on HIJET_SYSTEM_GUARD_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Throttle fully close learn HIJET_THROTTLE_FULLY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle idle position on HIJET_THROTTLE_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Throttle motor current HIJET_THROTTLE_MOTOR

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val×564
Range
0 to 19.9 A
Unit
A

In testing for 2014 to 2026.

Throttle motor duty HIJET_THROTTLE_MOTOR_DUTY

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Throttle motor duty, close HIJET_THROTTLE_MOTOR_DUTY_CLOSE

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2014 to 2026.

Throttle motor duty, open HIJET_THROTTLE_MOTOR_DUTY_OPEN

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2014 to 2026.

Throttle position HIJET_THROTTLE_21

  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Throttle position command HIJET_THROTTLE_POS_COMMAND

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle position, number 1 HIJET_THROTTLE_POS_NUMBER_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle position, number 2 HIJET_THROTTLE_POS_NUMBER_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle require position HIJET_THROTTLE_REQUIRE_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle sensor open position 1 HIJET_THROTTLE_SENS_OPEN_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle sensor open position 2 HIJET_THROTTLE_SENS_OPEN_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Throttle sensor position HIJET_THROTTLE_SENSOR_POSITION

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Throttle sensor voltage, 1 HIJET_THROTTLE_SENSOR_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Throttle sensor voltage, 2 HIJET_THROTTLE_SENSOR_2_VOLT

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2026.

Time since DTCs cleared HIJET_TIME_SINCE_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 min
Unit
min

In testing for 2014 to 2026.

Total fuel trim, bank 1 HIJET_TOT_FT_1

  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100256−50
Range
-50 to 49.6 %
Unit
%

In testing for 2014 to 2026.

Transmission output shaft speed HIJET_TRANS_OUT_RPM

  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2014 to 2026.

Turbine speed HIJET_SPD_NT

  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 rpm
Unit
rpm

In testing for 2014 to 2026.

Valvematic current angle HIJET_VALVEMATIC_CURRENT

  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2014 to 2026.

Valvematic, target angle HIJET_VALVEMATIC_TGT_ANG

  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×5512
Range
0 to 639.9 °
Unit
°

In testing for 2014 to 2026.

Variable valve timing aim angle 1 HIJET_VARIABLE_VLV_TIM_AIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1333218450
Range
0 to 399 %
Unit
%

In testing for 2014 to 2026.

Variable valve timing change angle 1 HIJET_VARIABLE_VLV_TIM_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×0.0097642481
Range
0 to 639 °
Unit
°

In testing for 2014 to 2026.

Variable valve timing control status 1 on HIJET_VARIABLE_VLV_TIM_1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Variable valve timing oil control valve duty 1 HIJET_VARIABLE_VLV_TIM_OIL_1

  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×0.0061020829
Range
0 to 399 %
Unit
%

In testing for 2014 to 2026.

Variable valve timing oil temperature HIJET_VVTOT

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Vehicle speed HIJET_VSS_21

  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2026.

Vehicle speed sensor test result, incomplete HIJET_SPD_TEST_RESULT

  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Warm-up cycles since DTCs cleared HIJET_WARMUP_CYCLES_DTC_CLEARED

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Misfires

All cylinders misfire count HIJET_ALL_CYLINDERS_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Cylinder #1 misfire count HIJET_CYL1_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Cylinder #2 misfire count HIJET_CYL2_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Cylinder #3 misfire count HIJET_CYL3_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Cylinder #4 misfire count HIJET_CYL4_MISFIRE_CNT

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Misfire load HIJET_MISFIRE_LOAD_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×4256
Range
0 to 3.98
Unit
Number

In testing for 2014 to 2026.

Misfire margin HIJET_MISFIRE_MARGIN_7E0

  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 %
Unit
%

In testing for 2014 to 2026.

Fluids

Distance since oil change HIJET_OIL_CHANGE_ODO

  • Service 21PID 41
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×251460015625
Range
0 to 41038.272 km
Unit
km

In testing for 2014 to 2026.

Fuel

Fuel cut HIJET_FUEL_CUT

  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Fuel cut HIJET_FUEL_CUT_7E0

  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 121 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Fuel cut time HIJET_FUEL_CUT_TIME

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×537512
Range
0 to 68734.9511
Unit
Number

In testing for 2014 to 2026.

Fuel injection timing HIJET_FUEL_INJ_TIM

  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×16125
Range
0 to 32.64 ms
Unit
ms

In testing for 2014 to 2026.

Fuel level HIJET_FUEL_LEVEL

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 1022
  • Module7C0 → 7C8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 L
Unit
L

In testing for 2014 to 2026.

Fuel level, volume HIJET_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Service 21PID 29
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×5003785
Range
0 to 21 gal
Unit
gal

0x14 = 20 → 20×5003785 = 2.642008 gal

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Fuel pump/speed status on HIJET_FUEL_PMP_SPD_STAT_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Target air-fuel equivalence ratio HIJET_LAMBDA_TARGET

  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1.9965535
Range
0 to 1.99
Unit
Number

In testing for 2014 to 2026.

Lights

Check engine SW HIJET_CHECK_ENGINE_LIGHT

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Hazard switch history HIJET_HAZARD_SWITCH_HISTORY

  • Service 21PID BC
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0INCOMPLETEIncomplete
1COMPLETEComplete

In testing for 2014 to 2026.

Oil pressure switch HIJET_EOP_LIGHT

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 35 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

P-seatbelt buckle SW HIJET_P_SEATBELT_BUCKLE_LIGHT

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rheostat HIJET_RHEOSTAT

Higher values are brighter

  • Service 21PID 68
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Stop light HIJET_STOP_LIGHT_SW

  • Service 21PID 1F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Stop light HIJET_STOP_LIGHT_SWITCH

  • Service 21PID 25
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Stop light relay HIJET_STOP_LIGHT_RELAY

  • Service 21PID 3C
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Tail cancel SW HIJET_TAIL_CANCEL_LIGHT

  • Service 21PID 12
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Movement

Accelerator fully close learn 1 HIJET_ACCEL_FULLY_CLOSE_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2014 to 2026.

Accelerator fully close learn 2 HIJET_ACCEL_FULLY_CLOSE_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val×125256
Range
0 to 124.5 °
Unit
°

In testing for 2014 to 2026.

Accelerator idle position on HIJET_ACCEL_IDLE_POS_ON

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 148 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Accelerator position HIJET_ACCEL_POS

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val×254096
Range
0 to 399.9 %
Unit
%

In testing for 2014 to 2026.

Accelerator sensor out, number 1 HIJET_ACCEL_SENS_OUT_1

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Accelerator sensor out, number 2 HIJET_ACCEL_SENS_OUT_2

  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×5256
Range
0 to 4.98 V
Unit
V

In testing for 2014 to 2026.

Average engine speed of all cylinders HIJET_AV_RPM_ALL_CYL

Pelican can show this parameter as the engine speed.

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Cruise control speed HIJET_CRUISE_CTRL_SPD

  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2026.

Engine speed of cylinder 1 HIJET_RPM_CYL_1

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Engine speed of cylinder 2 HIJET_RPM_CYL_2

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Engine speed of cylinder 3 HIJET_RPM_CYL_3

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Engine speed of cylinder 4 HIJET_RPM_CYL_4

  • Service 21PID 54
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Front left wheel acceleration HIJET_FL_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Front left wheel speed HIJET_TIRE_FL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Front left wheel speed? HIJET_FL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Front right wheel acceleration HIJET_FR_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Front right wheel speed HIJET_TIRE_FR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Front right wheel speed? HIJET_FR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

High voltage, target engine speed HIJET_HIGH_V_TGT_RPM

  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val×25
Range
0 to 6375 rpm
Unit
rpm

In testing for 2014 to 2026.

Minimum engine speed HIJET_MIN_RPM

  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val×2532
Range
0 to 51199 rpm
Unit
rpm

In testing for 2014 to 2026.

Rear left wheel acceleration HIJET_RL_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Rear left wheel speed HIJET_TIRE_RL_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Rear left wheel speed? HIJET_RL_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Rear right wheel acceleration HIJET_RR_WHEEL_ACCELERATION

  • Service 21PID 42
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val×1.56906
Range
-200.83 to 199.27 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Rear right wheel speed HIJET_TIRE_RR_SPDConfirmed

  • Service 21PID 03
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 16 to 23 of the reply, 8 bits.

Formula
val×256200
Range
0 to 326.4 km/h
Unit
km/h

0x00 = 0 → 0×256200 = 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Rear right wheel speed? HIJET_RR_WHEEL_SPEED_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Speed HIJET_VSS_7C0

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7C0 → 7C8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2026.

Vehicle speed HIJET_VEHICLE_SPEED_7E0

Pelican can show this parameter as the speed.

  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2026.

Vehicle speed HIJET_VSSConfirmed

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 21PID 21
  • Module7B0 → 7B8
  • Every200 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×1.35
Range
0 to 323.85 km/h
Unit
km/h

0x00 = 0 → 0×1.35 = 0 km/h

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Orientation

Deceleration HIJET_DECEL

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Deceleration 2 HIJET_DECEL_2

  • Service 21PID 05
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val×36.36255−18.18
Range
-18.18 to 18.18 m/s²
Unit
m/s²

In testing for 2014 to 2026.

Deceleration open HIJET_DECELERATION_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Lateral g HIJET_LAT_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Longitudinal g HIJET_LNG_GConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.5 to 2.5 g
Unit
g

0x00 = 0 → 050 = 0 g

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Yaw rate value, degrees/sec HIJET_YAW_RATEConfirmed

  • Service 21PID 47
  • Module7B0 → 7B8
  • Every250 ms
  • Testing for 2014 to 2022, 2024 to 2026

Example reply from a 2023 Daihatsu Hijet.

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127 °
Unit
°

0x74 = 116 → 116−128 = -12 °

Confirmed for 2023. In testing for 2014 to 2022, 2024 to 2026.

Yaw rate, error? HIJET_YAW_RATE_OPEN_ERROR

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Yaw rate, sensor 1 HIJET_YAW_1

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2014 to 2026.

Yaw rate, sensor 2 HIJET_YAW_2

  • Service 21PID 06
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2014 to 2026.

Zero point of deceleration HIJET_ZP_DEC

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2014 to 2026.

Zero point of deceleration 2 HIJET_ZP_DEC2

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits. The value is signed.

Formula
val50
Range
-2.56 to 2.54 g
Unit
g

In testing for 2014 to 2026.

Zero point of yaw rate HIJET_ZERO_POINT_OF_YAW_RATE

  • Service 21PID A1
  • Module7B0 → 7B8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2014 to 2026.

Zero point of yaw rate, degrees/sec HIJET_ZP_YAW

  • Service 21PID 46
  • Module7B0 → 7B8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val−128
Range
-128 to 127
Unit
Number

In testing for 2014 to 2026.

Seatbelts

Reverse beep HIJET_REVERSE_BEEP

  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2014 to 2026.

Seat belt beep, driver HIJET_SEAT_BELT_BEEP_DRIVER

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Seat belt beep, passenger HIJET_SEAT_BELT_BEEP_PASSENGER

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Seat belt beep, reminder HIJET_SEAT_BELT_BEEP_REMINDER

  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Tires

Brake assist status HIJET_BA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Front left wheel ABS status HIJET_FL_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Front left wheel vehicle stability control status HIJET_FL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Front right wheel ABS status HIJET_FR_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Front right wheel cylinder open HIJET_FR_WHEEL_CYLINDER_OPEN

  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2014 to 2026.

Front right wheel vehicle stability control status HIJET_FR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Predictive brake assist status HIJET_PBA_CTRL_STATUS

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear left wheel ABS status HIJET_RL_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear left wheel EBS status HIJET_RL_WHEEL_EBD_CTRL

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear left wheel vehicle stability control status HIJET_RL_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear right wheel ABS status HIJET_RR_WHEEL_ABS_CTRL

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear right wheel EBS status HIJET_RR_WHEEL_EBD_CTRL

Electronic brakeforce distribution

  • Service 21PID 5F
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Rear right wheel vehicle stability control status HIJET_RR_WHEEL_VSC_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Traction control, engine status HIJET_TRC_TRAC__ENGINE_CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Traction control, status HIJET_TRC_TRAC__CTRL

  • Service 21PID 5A
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2026.

Wheel cylinder pressure HIJET_WHEEL_CYLINDER_PRESSURE

  • Service 21PID 07
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2014 to 2026.

Transmission

Current gear HIJET_GEAR_V2

  • Service 21PID DA
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2026.

Torque converter and TE1 on HIJET_TQ_CONV_TE1_ON

  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Transmission fluid temperature, variant 5 HIJET_ATF_T_V_5

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2014 to 2026.

Transmission fluid temperature, variant 8 HIJET_ATF_T_V_8

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2014 to 2026.

Transmission fluid temperature, variant 14 HIJET_ATF_T_V_14

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2014 to 2026.

Transmission fluid temperature, variant 21 HIJET_ATF_T_V_21

  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2026.

Transmission oil pressure calibration, complete HIJET_TRANS_OIL_PRESS

  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2014 to 2026.

Trips

Odometer HIJET_ODO

Pelican can show this parameter as the odometer.

  • Service 21PID 28
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2014 to 2026.

Previous trip distance HIJET_PREV_TRIP_DST

  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km
Unit
km

In testing for 2014 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.