Dacia Spring

Parameters

The Dacia Spring has 230 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

AC charging power available SPRING_AC_P_AVAIL

  • Service 22DID 300F
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 kW
Unit
kW

In testing for 2021 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

AC charging power available SPRING_AC_P_AVAIL

  • Service 22DID 300F
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val40
Range
0 to 1638.375 kW
Unit
kW

In testing for 2021 to 2026.

AC mains current SPRING_AC_A

  • Service 22DID 300D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 A
Unit
A

In testing for 2021 to 2026.

AC mains phases SPRING_AC_PHASES

  • Service 22DID 300B
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0ONEOne phase
1TWOTwo phase
2THREEThree phase
3NONENot detected

In testing for 2021 to 2026.

AC mains voltage SPRING_AC_V

  • Service 22DID 2B8A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2021 to 2026.

Average voltage of cells SPRING_AVG_V_CELLS

  • Service 22DID 9006
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val69632
Range
-30840 to 30840 V
Unit
V

In testing for 2021 to 2026.

Battery voltage SPRING_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2006
  • Module743 → 763
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 1 SPRING_BUSBAR_V_NO_1

  • Service 22DID 9221
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 2 SPRING_BUSBAR_V_NO_2

  • Service 22DID 9222
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 3 SPRING_BUSBAR_V_NO_3

  • Service 22DID 9223
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 4 SPRING_BUSBAR_V_NO_4

  • Service 22DID 9224
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 5 SPRING_BUSBAR_V_NO_5

  • Service 22DID 9225
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 6 SPRING_BUSBAR_V_NO_6

  • Service 22DID 9226
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 7 SPRING_BUSBAR_V_NO_7

  • Service 22DID 9227
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Busbar voltage no. 8 SPRING_BUSBAR_V_NO_8

  • Service 22DID 9228
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×0.000976563
Range
-32 to 31.99 V
Unit
V

In testing for 2021 to 2026.

Cell overvoltage SPRING_CELLS_OVERVOLTAGE

  • Service 22DID 9216
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2021 to 2026.

Cell with the highest voltage SPRING_CELL_HIGHEST_V

  • Service 22DID 9008
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2021 to 2026.

Cell with the lowest voltage SPRING_CELL_LOWEST_V

  • Service 22DID 900A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val+1
Range
0 to 256
Unit
Number

In testing for 2021 to 2026.

Cells undervoltage SPRING_CELLS_UNDERVOLTAGE

  • Service 22DID 9216
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2021 to 2026.

Charge plug present SPRING_PLUG

Pelican can show this parameter as the plug state.

  • Service 22DID 2B85
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2021 to 2026.

Charge state SPRING_CHG_STATE

  • Service 22DID 2B6D
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0STOPPEDStopped
1TIMER_WAITWaiting for timer
2DONEDone
3CHARGINGBattery
4INTERRUPTEDInterrupted
5POWER_WAITWaiting for power
6FLAP_OPENCharge flap open
8PREPARINGPreparing

In testing for 2021 to 2026.

Charge type SPRING_CHG_TYPE

  • Service 22DID 2B7A
  • ModuleDADA → DA
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNDEFINEDUndefined
1TYPE2Type 2
2TYPE2Type 2
3CHADEMOCHAdeMO
4CCS

In testing for 2021 to 2026.

Complete charge cycles SPRING_CYCLES

  • Service 22DID 9210
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Energy charged, total SPRING_E_CHG

  • Service 22DID 9243
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2021 to 2026.

Energy discharged, total SPRING_E_DISCHG

  • Service 22DID 9245
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2021 to 2026.

Energy regenerated, total SPRING_E_REGEN

  • Service 22DID 9247
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 kWh
Unit
kWh

In testing for 2021 to 2026.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 13 to 14 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode
3Not PSA

Confirmed for 2025. Supported for 2026.

High voltage battery available energy SPRING_HV_E_AVAIL

  • Service 22DID 91C8
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val1000
Range
0 to 16777.215 kWh
Unit
kWh

In testing for 2021 to 2026.

High voltage battery average temperature SPRING_HV_T

  • Service 22DID 9012
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

High voltage battery current SPRING_HV_A

Pelican can show this parameter as the traction battery current.

  • Service 22DID 925D
  • ModuleDADB → DB
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×-132+1020
Range
-1027.97 to 1020 A
Unit
A

In testing for 2021 to 2026.

High voltage battery current SPRING_HV_A_3042

  • Service 22DID 3042
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−16383.75
Range
-16383.75 to 16383.75 A
Unit
A

In testing for 2021 to 2026.

High voltage battery current, vehicle controller SPRING_HV_A_EVC

  • Service 22DID 21CC
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4−500
Range
-500 to 15883.75 A
Unit
A

In testing for 2021 to 2026.

High voltage battery voltage SPRING_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 9005
  • ModuleDADB → DB
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2021 to 2026.

High voltage battery voltage, vehicle controller SPRING_HV_V_EVC

  • Service 22DID 20FE
  • ModuleDADA → DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 V
Unit
V

In testing for 2021 to 2026.

Highest cell voltage level SPRING_HIGHEST_CELL_V_LEVEL

  • Service 22DID 9007
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2021 to 2026.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2025. Supported for 2026.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.98 V
Unit
V

Confirmed for 2025. Supported for 2026.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2025. Supported for 2026.

Lowest cell voltage level SPRING_LOWEST_CELL_V_LEVEL

  • Service 22DID 9009
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2021 to 2026.

Maximum charge power SPRING_CHG_P_MAX

  • Service 22DID 9018
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 2021 to 2026.

Pack temperature 1 SPRING_PACK_T1

  • Service 22DID 9131
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 2 SPRING_PACK_T2

  • Service 22DID 9132
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 3 SPRING_PACK_T3

  • Service 22DID 9133
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 4 SPRING_PACK_T4

  • Service 22DID 9134
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 5 SPRING_PACK_T5

  • Service 22DID 9135
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 6 SPRING_PACK_T6

  • Service 22DID 9136
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 7 SPRING_PACK_T7

  • Service 22DID 9137
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 8 SPRING_PACK_T8

  • Service 22DID 9138
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 9 SPRING_PACK_T9

  • Service 22DID 9139
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 10 SPRING_PACK_T10

  • Service 22DID 913A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 11 SPRING_PACK_T11

  • Service 22DID 913B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

Pack temperature 12 SPRING_PACK_T12

  • Service 22DID 913C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055.9375 °C
Unit
°C

In testing for 2021 to 2026.

State of charge SPRING_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 9002
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2021 to 2026.

State of charge SPRING_SOC_9002

  • Service 22DID 9002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

State of charge, battery controller SPRING_SOC_9001

  • Service 22DID 9001
  • ModuleDADB → DB
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

State of charge, vehicle controller SPRING_SOC_EVC

  • Service 22DID 2002
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 %
Unit
%

In testing for 2021 to 2026.

State of health SPRING_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 9003
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2021 to 2026.

Traction battery input water temperature SPRING_TRACTION_BAT_INPUT_T

  • Service 22DID 91CD
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2021 to 2026.

Traction battery interlock SPRING_TRACTION_BAT_INTERLOCK

  • Service 22DID 91F7
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Traction battery max temperature SPRING_TRACTION_BAT_MAX_T

  • Service 22DID 9014
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2021 to 2026.

Traction battery min. temperature SPRING_TRACTION_BAT_MIN_T

  • Service 22DID 9013
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val16−40
Range
-40 to 4055 °C
Unit
°C

In testing for 2021 to 2026.

Traction battery overcurrent SPRING_TRACTION_BAT_OVERCURRENT

  • Service 22DID 9216
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2021 to 2026.

Traction battery overheating SPRING_TRACTION_BAT

  • Service 22DID 9216
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2021 to 2026.

Traction battery pack State of Health BAT_SOHSAE J1979Confirmed

  • Service 01PID B2
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2026.

Traction battery service plug interlock SPRING_TRACTION_BAT_SERVICE

  • Service 22DID 91F6
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Traction battery total mileage SPRING_TRACTION_BAT_TOT

  • Service 22DID 91CF
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val32+67108864
Range
0 to 134217727 km
Unit
km

In testing for 2021 to 2026.

Traction battery, current SPRING_TRACTION_BAT_CURRENT

  • Service 22DID 9284
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×-11000
Range
-2147483 to 2147483 A
Unit
A

In testing for 2021 to 2026.

Cells

Cell 1 voltage SPRING_CELL_V1

  • Service 22DID 9021
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 2 voltage SPRING_CELL_V2

  • Service 22DID 9022
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 3 voltage SPRING_CELL_V3

  • Service 22DID 9023
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 4 voltage SPRING_CELL_V4

  • Service 22DID 9024
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 5 voltage SPRING_CELL_V5

  • Service 22DID 9025
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 6 voltage SPRING_CELL_V6

  • Service 22DID 9026
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 7 voltage SPRING_CELL_V7

  • Service 22DID 9027
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 8 voltage SPRING_CELL_V8

  • Service 22DID 9028
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 9 voltage SPRING_CELL_V9

  • Service 22DID 9029
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 10 voltage SPRING_CELL_V10

  • Service 22DID 902A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 11 voltage SPRING_CELL_V11

  • Service 22DID 902B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 12 voltage SPRING_CELL_V12

  • Service 22DID 902C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 13 voltage SPRING_CELL_V13

  • Service 22DID 902D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 14 voltage SPRING_CELL_V14

  • Service 22DID 902E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 15 voltage SPRING_CELL_V15

  • Service 22DID 902F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 16 voltage SPRING_CELL_V16

  • Service 22DID 9030
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 17 voltage SPRING_CELL_V17

  • Service 22DID 9031
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 18 voltage SPRING_CELL_V18

  • Service 22DID 9032
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 19 voltage SPRING_CELL_V19

  • Service 22DID 9033
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 20 voltage SPRING_CELL_V20

  • Service 22DID 9034
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 21 voltage SPRING_CELL_V21

  • Service 22DID 9035
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 22 voltage SPRING_CELL_V22

  • Service 22DID 9036
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 23 voltage SPRING_CELL_V23

  • Service 22DID 9037
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 24 voltage SPRING_CELL_V24

  • Service 22DID 9038
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 25 voltage SPRING_CELL_V25

  • Service 22DID 9039
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 26 voltage SPRING_CELL_V26

  • Service 22DID 903A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 27 voltage SPRING_CELL_V27

  • Service 22DID 903B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 28 voltage SPRING_CELL_V28

  • Service 22DID 903C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 29 voltage SPRING_CELL_V29

  • Service 22DID 903D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 30 voltage SPRING_CELL_V30

  • Service 22DID 903E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 31 voltage SPRING_CELL_V31

  • Service 22DID 903F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 32 voltage SPRING_CELL_V32

  • Service 22DID 9041
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 33 voltage SPRING_CELL_V33

  • Service 22DID 9042
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 34 voltage SPRING_CELL_V34

  • Service 22DID 9043
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 35 voltage SPRING_CELL_V35

  • Service 22DID 9044
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 36 voltage SPRING_CELL_V36

  • Service 22DID 9045
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 37 voltage SPRING_CELL_V37

  • Service 22DID 9046
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 38 voltage SPRING_CELL_V38

  • Service 22DID 9047
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 39 voltage SPRING_CELL_V39

  • Service 22DID 9048
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 40 voltage SPRING_CELL_V40

  • Service 22DID 9049
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 41 voltage SPRING_CELL_V41

  • Service 22DID 904A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 42 voltage SPRING_CELL_V42

  • Service 22DID 904B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 43 voltage SPRING_CELL_V43

  • Service 22DID 904C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 44 voltage SPRING_CELL_V44

  • Service 22DID 904D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 45 voltage SPRING_CELL_V45

  • Service 22DID 904E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 46 voltage SPRING_CELL_V46

  • Service 22DID 904F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 47 voltage SPRING_CELL_V47

  • Service 22DID 9050
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 48 voltage SPRING_CELL_V48

  • Service 22DID 9051
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 49 voltage SPRING_CELL_V49

  • Service 22DID 9052
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 50 voltage SPRING_CELL_V50

  • Service 22DID 9053
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 51 voltage SPRING_CELL_V51

  • Service 22DID 9054
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 52 voltage SPRING_CELL_V52

  • Service 22DID 9055
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 53 voltage SPRING_CELL_V53

  • Service 22DID 9056
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 54 voltage SPRING_CELL_V54

  • Service 22DID 9057
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 55 voltage SPRING_CELL_V55

  • Service 22DID 9058
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 56 voltage SPRING_CELL_V56

  • Service 22DID 9059
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 57 voltage SPRING_CELL_V57

  • Service 22DID 905A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 58 voltage SPRING_CELL_V58

  • Service 22DID 905B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 59 voltage SPRING_CELL_V59

  • Service 22DID 905C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 60 voltage SPRING_CELL_V60

  • Service 22DID 905D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 61 voltage SPRING_CELL_V61

  • Service 22DID 905E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 62 voltage SPRING_CELL_V62

  • Service 22DID 905F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 63 voltage SPRING_CELL_V63

  • Service 22DID 9061
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 64 voltage SPRING_CELL_V64

  • Service 22DID 9062
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 65 voltage SPRING_CELL_V65

  • Service 22DID 9063
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 66 voltage SPRING_CELL_V66

  • Service 22DID 9064
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 67 voltage SPRING_CELL_V67

  • Service 22DID 9065
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 68 voltage SPRING_CELL_V68

  • Service 22DID 9066
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 69 voltage SPRING_CELL_V69

  • Service 22DID 9067
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 70 voltage SPRING_CELL_V70

  • Service 22DID 9068
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 71 voltage SPRING_CELL_V71

  • Service 22DID 9069
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 72 voltage SPRING_CELL_V72

  • Service 22DID 906A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 73 voltage SPRING_CELL_V73

  • Service 22DID 906B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 74 voltage SPRING_CELL_V74

  • Service 22DID 906C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 75 voltage SPRING_CELL_V75

  • Service 22DID 906D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 76 voltage SPRING_CELL_V76

  • Service 22DID 906E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 77 voltage SPRING_CELL_V77

  • Service 22DID 906F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 78 voltage SPRING_CELL_V78

  • Service 22DID 9070
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 79 voltage SPRING_CELL_V79

  • Service 22DID 9071
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 80 voltage SPRING_CELL_V80

  • Service 22DID 9072
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 81 voltage SPRING_CELL_V81

  • Service 22DID 9073
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 82 voltage SPRING_CELL_V82

  • Service 22DID 9074
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 83 voltage SPRING_CELL_V83

  • Service 22DID 9075
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 84 voltage SPRING_CELL_V84

  • Service 22DID 9076
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 85 voltage SPRING_CELL_V85

  • Service 22DID 9077
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 86 voltage SPRING_CELL_V86

  • Service 22DID 9078
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 87 voltage SPRING_CELL_V87

  • Service 22DID 9079
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 88 voltage SPRING_CELL_V88

  • Service 22DID 907A
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 89 voltage SPRING_CELL_V89

  • Service 22DID 907B
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 90 voltage SPRING_CELL_V90

  • Service 22DID 907C
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 91 voltage SPRING_CELL_V91

  • Service 22DID 907D
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 92 voltage SPRING_CELL_V92

  • Service 22DID 907E
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 93 voltage SPRING_CELL_V93

  • Service 22DID 907F
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 94 voltage SPRING_CELL_V94

  • Service 22DID 9081
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 95 voltage SPRING_CELL_V95

  • Service 22DID 9082
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Cell 96 voltage SPRING_CELL_V96

  • Service 22DID 9083
  • ModuleDADB → DB
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 V
Unit
V

In testing for 2021 to 2026.

Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2026.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2026.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2026.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. Supported for 2026.

Climate

A/C compressor discharge temperature SPRING_COMP_DIS_T

  • Service 22DID 440C
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−30
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2021 to 2026.

A/C compressor mode SPRING_COMP_MODE

  • Service 22DID 4402
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1ACA/C
2DEICEDe-ice
4HEAT_PUMPHeat pump
6DEMISTDemisting
7IDLEIdle

In testing for 2021 to 2026.

A/C compressor power SPRING_COMP_PWR

  • Service 22DID 4436
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 W
Unit
W

In testing for 2021 to 2026.

A/C compressor pressure SPRING_COMP_P

  • Service 22DID 4369
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 bar
Unit
bar

In testing for 2021 to 2026.

A/C compressor speed SPRING_COMP_RPM

  • Service 22DID 43D8
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

A/C compressor speed request SPRING_COMP_RPM_REQ

  • Service 22DID 4404
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

A/C compressor suction temperature SPRING_COMP_SUC_T

  • Service 22DID 440D
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−30
Range
-30 to 32737.5 °C
Unit
°C

In testing for 2021 to 2026.

Ambient air temperature SPRING_AAT

  • Service 22DID 2218
  • ModuleDADA → DA
  • Every20 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273
Range
-273 to 6280.5 °C
Unit
°C

In testing for 2021 to 2026.

Cabin temperature SPRING_CABIN_T

  • Service 22DID 4009
  • Module744 → 764
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10−40
Range
-3316.8 to 3236.7 °C
Unit
°C

In testing for 2021 to 2026.

Electric heater request SPRING_PTC_REQ

  • Service 22DID 4341
  • Module744 → 764
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

In testing for 2021 to 2026.

Evaporator temperature SPRING_EVAP_T

  • Service 22DID 400A
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2021 to 2026.

Evaporator temperature set point SPRING_EVAP_T_SET

  • Service 22DID 4368
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2021 to 2026.

Heating condenser temperature SPRING_COND_T

  • Service 22DID 4429
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2021 to 2026.

Heating condenser temperature set point SPRING_COND_T_SET

  • Service 22DID 43A5
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512−40
Range
-40 to 87.998 °C
Unit
°C

In testing for 2021 to 2026.

Heating temperature SPRING_HEAT_T

  • Service 22DID 43A4
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256−40
Range
-40 to 215.996 °C
Unit
°C

In testing for 2021 to 2026.

Doors

Front left door open SPRING_FL_DOOR

  • Service 22DID 6026
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Front right door open SPRING_FR_DOOR

  • Service 22DID 6027
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Rear left door open SPRING_RL_DOOR

  • Service 22DID 61B2
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Rear right door open SPRING_RR_DOOR

  • Service 22DID 61B3
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Tailgate open SPRING_TAILGATE

  • Service 22DID 609B
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Vehicle locked SPRING_LOCKED

  • Service 22DID 8004
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Drivetrain

Inverter high voltage SPRING_INV_HV_V

  • Service 22DID 2004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32
Range
0 to 2047.9687 V
Unit
V

In testing for 2021 to 2026.

Inverter high voltage current SPRING_INV_HV_A

  • Service 22DID 7049
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2021 to 2026.

Inverter state SPRING_INV_STATE

  • Service 22DID 21CF
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
1OFFOff
2ONOn
3DISCHARGINGDischarging
4ALTERNATORAlternator mode
5SLEEP_READYReady to sleep

In testing for 2021 to 2026.

Inverter temperature SPRING_INV_T

  • Service 22DID 700C
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2021 to 2026.

Motor speed SPRING_MOTOR_RPM

  • Service 22DID 3064
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2021 to 2026.

Rotor current sensor 1 SPRING_ROTOR_A1

  • Service 22DID 7003
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 A
Unit
A

In testing for 2021 to 2026.

Rotor current sensor 2 SPRING_ROTOR_A2

  • Service 22DID 7004
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1024
Range
0 to 63.999 A
Unit
A

In testing for 2021 to 2026.

Rotor reference resistance SPRING_ROTOR_R

  • Service 22DID 7050
  • ModuleDADF → DF
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val512
Range
0 to 127.998 Ω
Unit
Ω

In testing for 2021 to 2026.

Rotor temperature, estimated SPRING_ROTOR_T

  • Service 22DID 7088
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−40
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2021 to 2026.

Rotor temperature, raw SPRING_ROTOR_T_RAW

  • Service 22DID 7038
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128−40
Range
-40 to 471.9921 °C
Unit
°C

In testing for 2021 to 2026.

Stator current, phase U SPRING_STATOR_A_U

  • Service 22DID 7007
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2021 to 2026.

Stator current, phase V SPRING_STATOR_A_V

  • Service 22DID 7008
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2021 to 2026.

Stator current, phase W SPRING_STATOR_A_W

  • Service 22DID 7009
  • ModuleDADF → DF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val32−500
Range
-500 to 1547.9687 A
Unit
A

In testing for 2021 to 2026.

Stator temperature 1 SPRING_STATOR_T1

  • Service 22DID 700F
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2021 to 2026.

Stator temperature 2 SPRING_STATOR_T2

  • Service 22DID 7010
  • ModuleDADF → DF
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val512−40
Range
-40 to 32727.998 °C
Unit
°C

In testing for 2021 to 2026.

Electrical

12V battery voltage SPRING_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2005
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2021 to 2026.

Engine

Absolute time since first ignition SPRING_ABS_TIME_SINCE_FIRST

  • Service 22DID 9261
  • ModuleDADB → DB
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2021 to 2026.

Computer power supply SPRING_COMPUTER_POWER_SUP

  • Service 22DID 9011
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.000976563
Range
0 to 63.99 V
Unit
V

In testing for 2021 to 2026.

Fan unit SPRING_FAN_UNIT

  • Service 22DID 91EF
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2021 to 2026.

Fan unit feed SPRING_FAN_UNIT_FEED

  • Service 22DID 925A
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×4
Range
0 to 1020 Hz
Unit
Hz

In testing for 2021 to 2026.

Fault finding version SPRING_FAULT_FINDING

  • Service 22DID F1A0
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Ignition relay on SPRING_IGN

  • Service 22DID 60C6
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Module with, minimum temperature SPRING_MODULE_MIN_T

  • Service 22DID 9242
  • ModuleDADB → DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Motor-driven fan unit request SPRING_MOTOR_DRIVEN_FAN

  • Service 22DID 91C9
  • ModuleDADB → DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2021 to 2026.

Lights

Low beams on SPRING_LOW_BEAM

  • Service 22DID 4186
  • Module745 → 765
  • Every3 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2026.

Movement

Fan speed SPRING_FAN_SPD

  • Service 22DID 912E
  • ModuleDADB → DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×32
Range
0 to 8160 rpm
Unit
rpm

In testing for 2021 to 2026.

Fan speed SPRING_FAN_SPD_DADB

  • Service 22DID 91F0
  • ModuleDADB → DB
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2026.

Vehicle speed SPRING_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 2003
  • ModuleDADA → DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 km/h
Unit
km/h

In testing for 2021 to 2026.

Tires

Front left tire pressure SPRING_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 6300
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2021 to 2026.

Front left tire pressure alert SPRING_TP_FL_ALERT

  • Service 22DID 4109
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2021 to 2026.

Front left tire temperature SPRING_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID 6310
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2021 to 2026.

Front right tire pressure SPRING_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 6301
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2021 to 2026.

Front right tire pressure alert SPRING_TP_FR_ALERT

  • Service 22DID 410A
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2021 to 2026.

Front right tire temperature SPRING_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID 6311
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2021 to 2026.

Rear left tire pressure SPRING_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 6302
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2021 to 2026.

Rear left tire pressure alert SPRING_TP_RL_ALERT

  • Service 22DID 410B
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2021 to 2026.

Rear left tire temperature SPRING_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID 6312
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2021 to 2026.

Rear right tire pressure SPRING_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 6303
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×34
Range
0 to 767.25 kPa
Unit
kPa

In testing for 2021 to 2026.

Rear right tire pressure alert SPRING_TP_RR_ALERT

  • Service 22DID 410C
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1ALERTAlert
2WARNINGWarning
3ALERTAlert
4WARNINGWarning
5ALERTAlert
6WARNINGWarning
7ALERTAlert

In testing for 2021 to 2026.

Rear right tire temperature SPRING_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID 6313
  • Module745 → 765
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−30
Range
-30 to 97 °C
Unit
°C

In testing for 2021 to 2026.

Trips

Odometer SPRING_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 0207
  • Module743
  • Every30 s
  • Testing for 2021 to 2022

Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2023 to 2026. In testing for 2021 to 2022.

Odometer SPRING_ODO_EVC

Pelican can show this parameter as the odometer.

  • Service 22DID 2006
  • ModuleDADA → DA
  • Every10 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2021 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.