Cupra Tavascan

Parameters

The Cupra Tavascan has 258 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage TAVASCAN_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x26C9 = 9929 → 99291000+4 = 13.929 V

Confirmed for 2025. In testing for 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery adapted capacity TAVASCAN_AUX_BAT_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 100 Ah
Unit
Ah

0x2E = 46 → 46 Ah

Confirmed for 2025. In testing for 2024, 2026.

12V battery aging by capacity TAVASCAN_AUX_BAT_AGE_CAPConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x5B = 91 → 91 %

Confirmed for 2025. In testing for 2024, 2026.

12V battery aging by power TAVASCAN_AUX_BAT_AGE_POWConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x58 = 88 → 88 %

Confirmed for 2025. In testing for 2024, 2026.

12V battery current TAVASCAN_AUX_BAT_CConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
-1000000 to 1000000 A
Unit
A

0x00000078 = 120 → 1201000 = 0.12 A

Confirmed for 2025. In testing for 2024, 2026.

12V battery soc TAVASCAN_AUX_BAT_SOCConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x63 = 99 → 99 %

Confirmed for 2025. In testing for 2024, 2026.

12V battery total charge TAVASCAN_AUX_BAT_CHRG_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 96 to 127 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x000007ED = 2029 → 202910 = 202.9 Ah

Confirmed for 2025. In testing for 2024, 2026.

12V battery total discharge TAVASCAN_AUX_BAT_DSCH_TOTConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 128 to 159 of the reply, 32 bits.

Formula
val10
Range
0 to 10000000 Ah
Unit
Ah

0x00000609 = 1545 → 154510 = 154.5 Ah

Confirmed for 2025. In testing for 2024, 2026.

12V battery voltage TAVASCAN_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
0 to 69 V
Unit
V

0x26C9 = 9929 → 99291000+4 = 13.929 V

Confirmed for 2025. In testing for 2024, 2026.

AC charging TAVASCAN_AC_CHARGINGConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2024, 2026.

Average battery consumption TAVASCAN_HVBAT_CSMP_AVG_INTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

0x3D = 61 → 61 A

Confirmed for 2025. In testing for 2024, 2026.

Battery cell soc max, ID TAVASCAN_HVBAT_CELL_SOC_MAX_IDConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

Battery cell soc min, ID TAVASCAN_HVBAT_CELL_SOC_MIN_IDConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

Battery cell soc, maximum TAVASCAN_HVBAT_CELL_SOC_MAXConfirmed

  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Battery cell soc, minimum TAVASCAN_HVBAT_CELL_SOC_MINConfirmed

  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Battery current limit, charging TAVASCAN_HVBAT_I_LIM_CHGConfirmed

  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

Battery current limit, discharging TAVASCAN_HVBAT_I_LIM_DSCHConfirmed

  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

Battery current, DC, alternate TAVASCAN_HVBAT_I_DC_2Confirmed

  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
val100−1500
Range
-1500 to 42948172.95 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

Battery current, motor controller TAVASCAN_HVBAT_I_ENGConfirmed

  • Service 22DID 035E
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

Battery heater current TAVASCAN_HVBAT_PTC_IConfirmed

  • Service 22DID 1620
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

Battery heater temperature, #1 TAVASCAN_HVBAT_PTC_T_1Confirmed

  • Service 22DID 1623
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery heater temperature, #2 TAVASCAN_HVBAT_PTC_T_2Confirmed

  • Service 22DID 1624
  • ModuleFC00 → FE007B
  • Every5 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery heater voltage TAVASCAN_HVBAT_PTC_VConfirmed

  • Service 22DID 1621
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, inlet TAVASCAN_HVBAT_T_INConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, max TAVASCAN_HVBAT_T_MAX_V2Confirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, max sensor ID TAVASCAN_HVBAT_T_MAX_IDConfirmed

  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, min TAVASCAN_HVBAT_T_MINConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, min sensor ID TAVASCAN_HVBAT_T_MIN_IDConfirmed

  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

Battery temperature, outlet TAVASCAN_HVBAT_T_OUTConfirmed

  • Service 22DID 189D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, after main switch TAVASCAN_HVBAT_V_AFTERConfirmed

  • Service 22DID 1E38
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, before main switch TAVASCAN_HVBAT_V_BEFOREConfirmed

  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×31249978510000000000
Range
0 to 2047.967 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, charging TAVASCAN_HVBAT_V_CHGConfirmed

  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×31249978510000000000
Range
-1023.999 to 1023.967 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, sum of all cells TAVASCAN_HVBAT_V_CELLS_SUMConfirmed

  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val×2441406251000000000
Range
-524288 to 524287.99 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Battery voltage, traction mode TAVASCAN_HVBAT_V_TRACConfirmed

  • Service 22DID 4675
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Charge voltage, max TAVASCAN_MAXIMUM_CHARGE_VConfirmed

  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Charging, rapid? TAVASCAN_RAPID_CHARGE_PORTConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2024, 2026.

Control module temperature TAVASCAN_HVBAT_ECU_TConfirmed

  • Service 22DID 1622
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val−50
Range
-50 to 205 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Current gear TAVASCAN_DRIVE_MODEConfirmed

  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2025. In testing for 2024, 2026.

DC battery voltage TAVASCAN_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

DC-DC converter coolant temperature TAVASCAN_DCDC_T_COOLConfirmed

  • Service 22DID 43B8
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

DC-DC converter, current TAVASCAN_DCDC_IConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 8 to 23 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x0211 = 529 → 529−511 = 18 A

Confirmed for 2025. In testing for 2024, 2026.

DC-DC converter, low voltage TAVASCAN_DCDC_V_LOWConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

0x8C = 140 → 14010 = 14 V

Confirmed for 2025. In testing for 2024, 2026.

DC-DC converter, reserved current TAVASCAN_DCDC_I_RSVConfirmed

  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 24 to 39 of the reply, 16 bits.

Formula
val−511
Range
-511 to 65024 A
Unit
A

0x029B = 667 → 667−511 = 156 A

Confirmed for 2025. In testing for 2024, 2026.

Discharge voltage, min TAVASCAN_MINIMUM_DISCHARGE_VConfirmed

  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

ECall battery charge level TAVASCAN_ECALL_SOCConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x50 = 80 → 80 %

Confirmed for 2025. In testing for 2024, 2026.

Ecall battery charge status TAVASCAN_ECALL_BATTERY_CHARGE_STATUSConfirmed

  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x02 = 2 → 2

Confirmed for 2025. In testing for 2024, 2026.

Estimated electric power reserve TAVASCAN_RANGE_RESERVE_ESTConfirmed

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00A6 = 166 → 166 km

Confirmed for 2025. In testing for 2024, 2026.

Estimated reserve range TAVASCAN_RANGE_EST_CANConfirmed

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

0x00A6 = 166 → 166 km

Confirmed for 2025. In testing for 2024, 2026.

HV auxiliary current total TAVASCAN_HVAUX_IConfirmed

  • Service 22DID 0360
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2025. In testing for 2024, 2026.

HV auxiliary power TAVASCAN_HVAUX_PWRConfirmed

  • Service 22DID 0364
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 kW
Unit
kW

Confirmed for 2025. In testing for 2024, 2026.

HV battery after contacts voltage TAVASCAN_HVBAT_AFTER_CONTACTS_VConfirmed

  • Service 22DID 189B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−1000
Range
-1000 to 31767.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage max, ID TAVASCAN_HVBAT_CELL_V_MAX_IDConfirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage min, ID TAVASCAN_HVBAT_CELL_V_MIN_IDConfirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, maximum TAVASCAN_HVBAT_CELL_V_MAX_V2Confirmed

  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×244110000
Range
0 to 15.997 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, minimum TAVASCAN_HVBAT_CELL_V_MIN_V2Confirmed

  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val×244110000
Range
0 to 15.997 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery energy TAVASCAN_HVBAT_KWHConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638 kWh
Unit
kWh

0x0544 = 1348 → 1348×251000 = 33.7 kWh

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #1 TAVASCAN_HVBAT_MOD_T_1Confirmed

  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #2 TAVASCAN_HVBAT_MOD_T_2Confirmed

  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #3 TAVASCAN_HVBAT_MOD_T_3Confirmed

  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #4 TAVASCAN_HVBAT_MOD_T_4Confirmed

  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #17 TAVASCAN_HVBAT_MOD_T_17Confirmed

  • Service 22DID 7425
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #18 TAVASCAN_HVBAT_MOD_T_18Confirmed

  • Service 22DID 7426
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #19 TAVASCAN_HVBAT_MOD_T_19Confirmed

  • Service 22DID 7427
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #20 TAVASCAN_HVBAT_MOD_T_20Confirmed

  • Service 22DID 7428
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #21 TAVASCAN_HVBAT_MOD_T_21Confirmed

  • Service 22DID 7429
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #22 TAVASCAN_HVBAT_MOD_T_22Confirmed

  • Service 22DID 742A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #23 TAVASCAN_HVBAT_MOD_T_23Confirmed

  • Service 22DID 742B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #24 TAVASCAN_HVBAT_MOD_T_24Confirmed

  • Service 22DID 742C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery, max energy TAVASCAN_HVBAT_CAPConfirmed

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×501000
Range
0 to 3276.75 kWh
Unit
kWh

0x060B = 1547 → 1547×501000 = 77.35 kWh

Confirmed for 2025. In testing for 2024, 2026.

HV battery: circulation pump flow TAVASCAN_CIRC_PUMP_FLOWConfirmed

  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×10
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Start/stop battery resistance TAVASCAN_SSB_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×210
Range
0 to 51 mΩ
Unit
mΩ

0x00 = 0 → 0×210 = 0 mΩ

Confirmed for 2025. In testing for 2024, 2026.

State of charge TAVASCAN_SOC_FC00Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 3DEF
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

State of charge TAVASCAN_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100250
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Temperature, 12V battery TAVASCAN_AUX_BAT_TConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 64 to 71 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x33 = 51 → 51−40 = 11 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, 12V battery sensor TAVASCAN_AUX_BAT_T_SConfirmed

  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 72 to 79 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x34 = 52 → 52−40 = 12 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, battery TAVASCAN_BATTERY_TConfirmed

  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Cells

HV battery cell voltage, #1 TAVASCAN_HVBAT_CELL_V_001Confirmed

  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #2 TAVASCAN_HVBAT_CELL_V_002Confirmed

  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #3 TAVASCAN_HVBAT_CELL_V_003Confirmed

  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #4 TAVASCAN_HVBAT_CELL_V_004Confirmed

  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #5 TAVASCAN_HVBAT_CELL_V_005Confirmed

  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #6 TAVASCAN_HVBAT_CELL_V_006Confirmed

  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #7 TAVASCAN_HVBAT_CELL_V_007Confirmed

  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #8 TAVASCAN_HVBAT_CELL_V_008Confirmed

  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #9 TAVASCAN_HVBAT_CELL_V_009Confirmed

  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #10 TAVASCAN_HVBAT_CELL_V_010Confirmed

  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #11 TAVASCAN_HVBAT_CELL_V_011Confirmed

  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #12 TAVASCAN_HVBAT_CELL_V_012Confirmed

  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #13 TAVASCAN_HVBAT_CELL_V_013Confirmed

  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #14 TAVASCAN_HVBAT_CELL_V_014Confirmed

  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #15 TAVASCAN_HVBAT_CELL_V_015Confirmed

  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #16 TAVASCAN_HVBAT_CELL_V_016Confirmed

  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #17 TAVASCAN_HVBAT_CELL_V_017Confirmed

  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #18 TAVASCAN_HVBAT_CELL_V_018Confirmed

  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #19 TAVASCAN_HVBAT_CELL_V_019Confirmed

  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #20 TAVASCAN_HVBAT_CELL_V_020Confirmed

  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #21 TAVASCAN_HVBAT_CELL_V_021Confirmed

  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #22 TAVASCAN_HVBAT_CELL_V_022Confirmed

  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #23 TAVASCAN_HVBAT_CELL_V_023Confirmed

  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #24 TAVASCAN_HVBAT_CELL_V_024Confirmed

  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #25 TAVASCAN_HVBAT_CELL_V_025Confirmed

  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #26 TAVASCAN_HVBAT_CELL_V_026Confirmed

  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #27 TAVASCAN_HVBAT_CELL_V_027Confirmed

  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #28 TAVASCAN_HVBAT_CELL_V_028Confirmed

  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #29 TAVASCAN_HVBAT_CELL_V_029Confirmed

  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #30 TAVASCAN_HVBAT_CELL_V_030Confirmed

  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #31 TAVASCAN_HVBAT_CELL_V_031Confirmed

  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #32 TAVASCAN_HVBAT_CELL_V_032Confirmed

  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #33 TAVASCAN_HVBAT_CELL_V_033Confirmed

  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #34 TAVASCAN_HVBAT_CELL_V_034Confirmed

  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #35 TAVASCAN_HVBAT_CELL_V_035Confirmed

  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #36 TAVASCAN_HVBAT_CELL_V_036Confirmed

  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #37 TAVASCAN_HVBAT_CELL_V_037Confirmed

  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #38 TAVASCAN_HVBAT_CELL_V_038Confirmed

  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #39 TAVASCAN_HVBAT_CELL_V_039Confirmed

  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #40 TAVASCAN_HVBAT_CELL_V_040Confirmed

  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #41 TAVASCAN_HVBAT_CELL_V_041Confirmed

  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #42 TAVASCAN_HVBAT_CELL_V_042Confirmed

  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #43 TAVASCAN_HVBAT_CELL_V_043Confirmed

  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #44 TAVASCAN_HVBAT_CELL_V_044Confirmed

  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #45 TAVASCAN_HVBAT_CELL_V_045Confirmed

  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #46 TAVASCAN_HVBAT_CELL_V_046Confirmed

  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #47 TAVASCAN_HVBAT_CELL_V_047Confirmed

  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #48 TAVASCAN_HVBAT_CELL_V_048Confirmed

  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #49 TAVASCAN_HVBAT_CELL_V_049Confirmed

  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #50 TAVASCAN_HVBAT_CELL_V_050Confirmed

  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #51 TAVASCAN_HVBAT_CELL_V_051Confirmed

  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #52 TAVASCAN_HVBAT_CELL_V_052Confirmed

  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #53 TAVASCAN_HVBAT_CELL_V_053Confirmed

  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #54 TAVASCAN_HVBAT_CELL_V_054Confirmed

  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #55 TAVASCAN_HVBAT_CELL_V_055Confirmed

  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #56 TAVASCAN_HVBAT_CELL_V_056Confirmed

  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #57 TAVASCAN_HVBAT_CELL_V_057Confirmed

  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #58 TAVASCAN_HVBAT_CELL_V_058Confirmed

  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #59 TAVASCAN_HVBAT_CELL_V_059Confirmed

  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #60 TAVASCAN_HVBAT_CELL_V_060Confirmed

  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #61 TAVASCAN_HVBAT_CELL_V_061Confirmed

  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #62 TAVASCAN_HVBAT_CELL_V_062Confirmed

  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #63 TAVASCAN_HVBAT_CELL_V_063Confirmed

  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #64 TAVASCAN_HVBAT_CELL_V_064Confirmed

  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #65 TAVASCAN_HVBAT_CELL_V_065Confirmed

  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #66 TAVASCAN_HVBAT_CELL_V_066Confirmed

  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #67 TAVASCAN_HVBAT_CELL_V_067Confirmed

  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #68 TAVASCAN_HVBAT_CELL_V_068Confirmed

  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #69 TAVASCAN_HVBAT_CELL_V_069Confirmed

  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #70 TAVASCAN_HVBAT_CELL_V_070Confirmed

  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #71 TAVASCAN_HVBAT_CELL_V_071Confirmed

  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #72 TAVASCAN_HVBAT_CELL_V_072Confirmed

  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #73 TAVASCAN_HVBAT_CELL_V_073Confirmed

  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #74 TAVASCAN_HVBAT_CELL_V_074Confirmed

  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #75 TAVASCAN_HVBAT_CELL_V_075Confirmed

  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #76 TAVASCAN_HVBAT_CELL_V_076Confirmed

  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #77 TAVASCAN_HVBAT_CELL_V_077Confirmed

  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #78 TAVASCAN_HVBAT_CELL_V_078Confirmed

  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #79 TAVASCAN_HVBAT_CELL_V_079Confirmed

  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #80 TAVASCAN_HVBAT_CELL_V_080Confirmed

  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #81 TAVASCAN_HVBAT_CELL_V_081Confirmed

  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #82 TAVASCAN_HVBAT_CELL_V_082Confirmed

  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #83 TAVASCAN_HVBAT_CELL_V_083Confirmed

  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #84 TAVASCAN_HVBAT_CELL_V_084Confirmed

  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #85 TAVASCAN_HVBAT_CELL_V_085Confirmed

  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #86 TAVASCAN_HVBAT_CELL_V_086Confirmed

  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #87 TAVASCAN_HVBAT_CELL_V_087Confirmed

  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #88 TAVASCAN_HVBAT_CELL_V_088Confirmed

  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #89 TAVASCAN_HVBAT_CELL_V_089Confirmed

  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #90 TAVASCAN_HVBAT_CELL_V_090Confirmed

  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #91 TAVASCAN_HVBAT_CELL_V_091Confirmed

  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #92 TAVASCAN_HVBAT_CELL_V_092Confirmed

  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #93 TAVASCAN_HVBAT_CELL_V_093Confirmed

  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #94 TAVASCAN_HVBAT_CELL_V_094Confirmed

  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #95 TAVASCAN_HVBAT_CELL_V_095Confirmed

  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #96 TAVASCAN_HVBAT_CELL_V_096Confirmed

  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #97 TAVASCAN_HVBAT_CELL_V_097Confirmed

  • Service 22DID 1EA0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #98 TAVASCAN_HVBAT_CELL_V_098Confirmed

  • Service 22DID 1EA1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #99 TAVASCAN_HVBAT_CELL_V_099Confirmed

  • Service 22DID 1EA2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #100 TAVASCAN_HVBAT_CELL_V_100Confirmed

  • Service 22DID 1EA3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #101 TAVASCAN_HVBAT_CELL_V_101Confirmed

  • Service 22DID 1EA4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #102 TAVASCAN_HVBAT_CELL_V_102Confirmed

  • Service 22DID 1EA5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #103 TAVASCAN_HVBAT_CELL_V_103Confirmed

  • Service 22DID 1EA6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #104 TAVASCAN_HVBAT_CELL_V_104Confirmed

  • Service 22DID 1EA7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #105 TAVASCAN_HVBAT_CELL_V_105Confirmed

  • Service 22DID 1EA8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #106 TAVASCAN_HVBAT_CELL_V_106Confirmed

  • Service 22DID 1EA9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #107 TAVASCAN_HVBAT_CELL_V_107Confirmed

  • Service 22DID 1EAA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

HV battery cell voltage, #108 TAVASCAN_HVBAT_CELL_V_108Confirmed

  • Service 22DID 1EAB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+1
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2024, 2026.

Modules

HV battery module temperature, #5 TAVASCAN_HVBAT_MOD_T_5Confirmed

  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #6 TAVASCAN_HVBAT_MOD_T_6Confirmed

  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #7 TAVASCAN_HVBAT_MOD_T_7Confirmed

  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #8 TAVASCAN_HVBAT_MOD_T_8Confirmed

  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #9 TAVASCAN_HVBAT_MOD_T_9Confirmed

  • Service 22DID 1EB6
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #10 TAVASCAN_HVBAT_MOD_T_10Confirmed

  • Service 22DID 1EB7
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #11 TAVASCAN_HVBAT_MOD_T_11Confirmed

  • Service 22DID 1EB8
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #12 TAVASCAN_HVBAT_MOD_T_12Confirmed

  • Service 22DID 1EB9
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #13 TAVASCAN_HVBAT_MOD_T_13Confirmed

  • Service 22DID 1EBA
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #14 TAVASCAN_HVBAT_MOD_T_14Confirmed

  • Service 22DID 1EBB
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #15 TAVASCAN_HVBAT_MOD_T_15Confirmed

  • Service 22DID 1EBC
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

HV battery module temperature, #16 TAVASCAN_HVBAT_MOD_T_16Confirmed

  • Service 22DID 1EBD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val8−40
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2024, 2026.

Climate

A/C compressor power, actual TAVASCAN_AC_COMPRESSOR_PWR_ACTConfirmed

  • Service 22DID 0800
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

Confirmed for 2025. In testing for 2024, 2026.

A/C refrigerant pressure, sensor 1 TAVASCAN_AC_REFRIG_P_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val×8810000
Range
0 to 576.708 bar
Unit
bar

0x0274 = 628 → 628×8810000 = 5.5264 bar

Confirmed for 2025. In testing for 2024, 2026.

A/C refrigerant temperature, sensor 1 TAVASCAN_AC_REFRIG_T_SENS1Confirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

0x7E9A = 32410 → 32410×10100−40 = 3,201 °C

Confirmed for 2025. In testing for 2024, 2026.

A/C refrigerant temperature, sensor 1 interior TAVASCAN_AC_REFRIG_T_SENS1_INTConfirmed

  • Service 22DID 4EEF
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 32 to 47 of the reply, 16 bits.

Formula
val×10100−40
Range
-40 to 6513.5 °C
Unit
°C

0x7E9A = 32410 → 32410×10100−40 = 3,201 °C

Confirmed for 2025. In testing for 2024, 2026.

Air pollution level TAVASCAN_AIR_POLUTIONConfirmed

0 means clean air.

  • Service 22DID 26ED
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val10
Range
-12.7 to 12.7
Unit
Number

0x00 = 0 → 010 = 0

Confirmed for 2025. In testing for 2024, 2026.

CO2 content interior TAVASCAN_CO2_CONTENT_INTERIORConfirmed

  • Service 22DID 42DB
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500
Unit
Number

0x04 = 4 → 4×100 = 400

Confirmed for 2025. In testing for 2024, 2026.

Humidity, inside TAVASCAN_HVAC_INSIDE_HUMConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 32 to 39 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x7E = 126 → 1262 = 63 %

Confirmed for 2025. In testing for 2024, 2026.

Outside humidity TAVASCAN_HVAC_OUTSIDE_HUM

  • Service 22DID 27C3
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2024, 2026. Not supported for 2025.

Outside temperature TAVASCAN_AAT_V2Confirmed

  • Service 22DID 2609
  • Module746 → 7B0
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x6B = 107 → 1072−50 = 3.5 °C

Confirmed for 2025. In testing for 2024, 2026.

Radiator fan actual duty TAVASCAN_RAD_FAN_ACT_DUTYConfirmed

  • Service 22DID 2606
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×25
Range
0 to 100 %
Unit
%

0x00 = 0 → 0×25 = 0 %

Confirmed for 2025. In testing for 2024, 2026.

Recirculation flap stop, fresh air TAVASCAN_RECIRC_FLAP_STOP_FRESHConfirmed

  • Service 22DID 2620
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x00AA = 170 → 170

Confirmed for 2025. In testing for 2024, 2026.

Recirculation flap stop, recirculated air TAVASCAN_RECIRC_FLAP_STOP_RECIRCConfirmed

  • Service 22DID 2621
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x035F = 863 → 863

Confirmed for 2025. In testing for 2024, 2026.

Recirculation flap, actual TAVASCAN_RECIRC_FLAP_ACT_PCTConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x76 = 118 → 1182 = 59 %

Confirmed for 2025. In testing for 2024, 2026.

Recirculation flap, actual steps TAVASCAN_RECIRC_FLAP_ACT_STEPSConfirmed

  • Service 22DID 261E
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0243 = 579 → 579

Confirmed for 2025. In testing for 2024, 2026.

Recirculation flap, commanded steps TAVASCAN_RECIRC_FLAP_CMD_STEPSConfirmed

  • Service 22DID 261F
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0212 = 530 → 530

Confirmed for 2025. In testing for 2024, 2026.

Refrigerant pressure TAVASCAN_REFRIG_PConfirmed

  • Service 22DID 2605
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 bar
Unit
bar

0xFF = 255 → 2555 = 51 bar

Confirmed for 2025. In testing for 2024, 2026.

Windshield, temperature TAVASCAN_WNDSHLD_TEMPConfirmed

  • Service 22DID 27C4
  • Module746 → 7B0
  • Every30 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.576−38.8
Range
-38.8 to 108.08 °C
Unit
°C

0x6A = 106 → 106×0.576−38.8 = 22.256 °C

Confirmed for 2025. In testing for 2024, 2026.

Control

Brake booster pressure TAVASCAN_BRAKE_BOOSTER_P_V2Confirmed

  • Service 22DID 2005
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2025. In testing for 2024, 2026.

Steering wheel angle TAVASCAN_STEER_ANGLE_V2Confirmed

  • Service 22DID 0346
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °
Unit
°

Confirmed for 2025. In testing for 2024, 2026.

Drivetrain

Motor speed TAVASCAN_MOTOR_RPMConfirmed

  • Service 22DID 3DF8
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 rpm
Unit
rpm

Confirmed for 2025. In testing for 2024, 2026.

Motor torque difference, front to rear TAVASCAN_MOTOR_TRQ_DIFFConfirmed

  • Service 22DID 0343
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

Confirmed for 2025. In testing for 2024, 2026.

Motor torque rated, front TAVASCAN_MOTOR_TRQ_RATED_FRONTConfirmed

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

Confirmed for 2025. In testing for 2024, 2026.

Motor torque rated, rear TAVASCAN_MOTOR_TRQ_RATED_REAR

  • Service 22DID 0344
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383.5 N·m
Unit
N·m

In testing for 2024, 2026. Supported for 2025.

Motor torque, front TAVASCAN_MOTOR_TRQ_FRONTConfirmed

  • Service 22DID 0335
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Confirmed for 2025. In testing for 2024, 2026.

Motor torque, rear TAVASCAN_MOTOR_TRQ_REARConfirmed

  • Service 22DID 033B
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

Confirmed for 2025. In testing for 2024, 2026.

Torque, calculated from measured currents TAVASCAN_CALC_FROM_MEAS_IS

  • Service 22DID 0308
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 N·m
Unit
N·m

In testing for 2024, 2026. Not supported for 2025.

Engine

A/C compressor load TAVASCAN_CLIMATE_A_C_COMP_LOADConfirmed

  • Service 22DID 2604
  • Module746 → 7B0
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 N·m
Unit
N·m

0x00 = 0 → 010 = 0 N·m

Confirmed for 2025. In testing for 2024, 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2024.

Coolant circulation pump duty TAVASCAN_COOLANT_CIRC_PUMP_DUTYConfirmed

  • Service 22DID 276D
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Electric motor non-vehicle power limitation TAVASCAN_HV_EM_NV_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 24 to 31 of the reply, 8 bits.

Formula
val×50
Range
0 to 12750 W
Unit
W

0xB1 = 177 → 177×50 = 8,850 W

Confirmed for 2025. In testing for 2024, 2026.

Electric motor power limitation TAVASCAN_HV_EM_PWR_LIMITATIONConfirmed

  • Service 22DID 15D1
  • Module710 → 77A
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 8 to 23 of the reply, 16 bits.

Formula
val×50
Range
0 to 3276750 W
Unit
W

0x0101 = 257 → 257×50 = 12,850 W

Confirmed for 2025. In testing for 2024, 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. Supported for 2024.

Front left temperature flap actual TAVASCAN_FRONT_LEFT_T_FLAP_ACTConfirmed

  • Service 22DID 2622
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x1C = 28 → 282 = 14 %

Confirmed for 2025. In testing for 2024, 2026.

Front right temperature flap actual TAVASCAN_FRONT_RIGHT_T_FLAP_ACTConfirmed

  • Service 22DID 2626
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

0x3F = 63 → 632 = 31.5 %

Confirmed for 2025. In testing for 2024, 2026.

Outside temperature, from cabin sensor TAVASCAN_AAT_CABINConfirmed

  • Service 22DID 260A
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−50
Range
-50 to 77.5 °C
Unit
°C

0x6A = 106 → 1062−50 = 3 °C

Confirmed for 2025. In testing for 2024, 2026.

Radiator fan commanded duty TAVASCAN_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

0x00 = 0 → 02.5 = 0 %

Confirmed for 2025. In testing for 2024, 2026.

Radiator fan duty TAVASCAN_RADIATOR_FAN_DUTYConfirmed

  • Service 22DID 2055
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2024, 2026.

Temperature, evaporator output TAVASCAN_HVAC_EVAP_TConfirmed

  • Service 22DID 2612
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x0190 = 400 → 40010 = 40 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, front left deflector TAVASCAN_FRONT_LEFT_DEFL_TConfirmed

  • Service 22DID 260C
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x6C = 108 → 108×0.333 = 35.964 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, front right deflector TAVASCAN_FRONT_RIGHT_DEFL_TConfirmed

  • Service 22DID 260D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x62 = 98 → 98×0.333 = 32.634 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, interior TAVASCAN_HVAC_IATConfirmed

  • Service 22DID 2613
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

0x00F1 = 241 → 24110 = 24.1 °C

Confirmed for 2025. In testing for 2024, 2026.

Temperature, rear deflector TAVASCAN_REAR_DEFL_TConfirmed

  • Service 22DID 263D
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.333
Range
0 to 84.915 °C
Unit
°C

0x72 = 114 → 114×0.333 = 37.962 °C

Confirmed for 2025. In testing for 2024, 2026.

GPS

Satellites, tracked TAVASCAN_GPS_SATS_TRACKEDConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x10 = 16 → 16

Confirmed for 2025. In testing for 2024, 2026.

Satellites, visible TAVASCAN_GPS_SATS_VISIBLEConfirmed

  • Service 22DID 2431
  • Module767 → 7D1
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

0x04 = 4 → 4

Confirmed for 2025. In testing for 2024, 2026.

Movement

A/C compressor, speed TAVASCAN_A_C_CMPR_SPEEDConfirmed

  • Service 22DID 2603
  • Module746 → 7B0
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100
Range
0 to 25500 rpm
Unit
rpm

0x00 = 0 → 0×100 = 0 rpm

Confirmed for 2025. In testing for 2024, 2026.

Acceleration TAVASCAN_ACCEL_V3Confirmed

  • Service 22DID 4539
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 m/s²
Unit
m/s²

Confirmed for 2025. In testing for 2024, 2026.

Motor RPM TAVASCAN_ELDRIVE_MOTOR_RPMConfirmed

  • Service 22DID F40C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2025. In testing for 2024, 2026.

Vehicle speed TAVASCAN_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. In testing for 2024, 2026.

Stats

Crashes, driver side TAVASCAN_CRASH_DRVRConfirmed

  • Service 22DID 2354
  • Module715 → 77F
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2024, 2026.

Crashes, front TAVASCAN_CRASH_FRONTConfirmed

  • Service 22DID 2353
  • Module715 → 77F
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2024, 2026.

Crashes, passenger side TAVASCAN_CRASH_PASSConfirmed

  • Service 22DID 2355
  • Module715 → 77F
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2024, 2026.

Crashes, rear TAVASCAN_CRASH_REARConfirmed

  • Service 22DID 2356
  • Module715 → 77F
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2024, 2026.

Rollovers TAVASCAN_ROLLOVERConfirmed

  • Service 22DID 2357
  • Module715 → 77F
  • Every1 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

0x00 = 0 → 0

Confirmed for 2025. In testing for 2024, 2026.

Trips

Average consumption, category 0 TAVASCAN_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x008E = 142 → 14210 = 14.2 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 1 TAVASCAN_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0088 = 136 → 13610 = 13.6 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 2 TAVASCAN_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0080 = 128 → 12810 = 12.8 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 3 TAVASCAN_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x009A = 154 → 15410 = 15.4 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 4 TAVASCAN_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x009F = 159 → 15910 = 15.9 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 5 TAVASCAN_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00E6 = 230 → 23010 = 23 kWh

Confirmed for 2025. In testing for 2024, 2026.

Average consumption, category 6 TAVASCAN_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2025. In testing for 2024, 2026.

Odometer TAVASCAN_ENG_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID 295A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2024, 2026

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 200000 km
Unit
km

Confirmed for 2025. In testing for 2024, 2026.

Odometer, BMS TAVASCAN_BMS_ODO

  • Service 22DID 02BD
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2024, 2026. Not supported for 2025.

Range remaining, displayed TAVASCAN_RANGEConfirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2024, 2026

Example reply from a 2025 Cupra Tavascan.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x00A6 = 166 → 166 mi

Confirmed for 2025. In testing for 2024, 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.