Cadillac ELR

Parameters

The Cadillac ELR has 275 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

AC energy from the wall, last or current charge ELR_LAST_CHG_AC_KWH

  • Service 22DID 437D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 kWh
Unit
kWh

In testing for 2014 to 2016.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

AC energy from the wall, last or current charge ELR_LAST_CHG_AC_KWH

  • Service 22DID 437D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.34 kWh
Unit
kWh

In testing for 2014 to 2016.

Battery average cell voltage ELR_BECM_AVG_CELL_V

  • Service 22DID C218
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565536
Range
0 to 4.99 V
Unit
V

In testing for 2014 to 2016.

Battery controller 5V reference voltage ELR_BECM_5V_REFERENCE_V_1

  • Service 22DID 40D3
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×565536+5
Range
0 to 7.49 V
Unit
V

In testing for 2014 to 2016.

Battery coolant temperature ELR_BECM_BAT_ECT

  • Service 22DID 41A4
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery heater duty ELR_HEATER_BAT_PCT

  • Service 22DID 439E
  • Module7E4 → 7EC
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Battery heater power ELR_HEATER_BAT

  • Service 22DID 41B6
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2014 to 2016.

Battery section 1 temperature ELR_BECM_BAT_SECTION_1_T

  • Service 22DID 40D7
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery section 2 temperature ELR_BECM_BAT_SECTION_2_T

  • Service 22DID 40D9
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery section 3 temperature ELR_BECM_BAT_SECTION_3_T

  • Service 22DID 40DB
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery section 4 temperature ELR_BECM_BAT_SECTION_4_T

  • Service 22DID 40DD
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery section 5 temperature ELR_BECM_BAT_SECTION_5_T

  • Service 22DID 40DF
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery section 6 temperature ELR_BECM_BAT_SECTION_6_T

  • Service 22DID 40E1
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Charge air cooler temperature sensor 1 ELR_CHARGE_AIR_COOLER_T_SNS_1

  • Service 22DID 30AD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Charge air cooler temperature sensor 2 ELR_CHARGE_AIR_COOLER_T_SNS_2

  • Service 22DID 30AE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Charger AC current ELR_CHARGE_AC_CURR

  • Service 22DID 4369
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51 A
Unit
A

In testing for 2014 to 2016.

Charger AC voltage ELR_CHARGE_AC_VOLT

  • Service 22DID 4368
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 V
Unit
V

In testing for 2014 to 2016.

Charger HV current ELR_CHARGE_HV_CURR

  • Service 22DID 436C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638.4 to 1638.35 A
Unit
A

In testing for 2014 to 2016.

Charger HV voltage ELR_CHARGE_HV_VOLT

  • Service 22DID 436B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2
Range
0 to 32767.5 V
Unit
V

In testing for 2014 to 2016.

Charging level ELR_CHARGE_LVL

  • Service 22DID 4531
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_CHARGINGNot charging
1AC_1A/C Level 1
2AC_2A/C Level 2
3DC

In testing for 2014 to 2016.

Charging mode ELR_CHARGE_MODE

Pelican can show this parameter as the charging state.

  • Service 22DID 4373
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bit 15 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0NOT_CHARGINGNot charging
1CHARGINGCharging

In testing for 2014 to 2016.

Electric range remaining ELR_EV_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 41A6
  • Module7E4 → 7EC
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023.9843 km
Unit
km

In testing for 2014 to 2016.

High voltage volts ELR_HIGH_V_VOLTS

  • Service 22DID 2429
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 V
Unit
V

In testing for 2014 to 2016.

HV battery capacity ELR_HVBAT_CAP_AH

  • Service 22DID 41A3
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 Ah
Unit
Ah

In testing for 2014 to 2016.

HV battery capacity, 2019 ELR_HVBAT_CAP_AH_2019

  • Service 22DID 45FF
  • Module7E4 → 7EC
  • Every600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2014 to 2016.

HV battery charge ELR_HVBAT_SOC_DISPLAY

Pelican can show this parameter as the state of charge.

  • Service 22DID 8334
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

HV battery charge count ELR_HVBAT_CHRG_CNT

  • Service 22DID 43A5
  • Module7E4 → 7EC
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

HV battery charge, raw ELR_HVBAT_SOC_RAW

Pelican can show this parameter as the state of charge.

  • Service 22DID 43AF
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10065535
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

HV battery current ELR_HVBAT_A

Pelican can show this parameter as the traction battery current.

  • Service 22DID 40D4
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×-120
Range
-1638.35 to 1638.4 A
Unit
A

In testing for 2014 to 2016.

HV battery temperature ELR_HVBAT_TEMP

  • Service 22DID 434F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

HV battery voltage ELR_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 432D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.52
Range
0 to 34078.2 V
Unit
V

In testing for 2014 to 2016.

Ignition 1 voltage ELR_IGN_1_V

  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2014 to 2016.

Lifetime charge energy ELR_CHG_LIFETIME

  • Service 22DID 4389
  • Module7E4 → 7EC
  • Every300 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2014 to 2016.

M control module voltage ELR_M_CTRL_MODULE_V

  • Service 22DID 0042
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2014 to 2016.

MG voltage 2 ELR_MG_V_2

  • Service 22DID 1C24
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2014 to 2016.

MG voltage 6 ELR_MG_V_6

  • Service 22DID 4329
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×0.0592111886
Range
0 to 3880 V
Unit
V

In testing for 2014 to 2016.

Motor-generator A voltage ELR_MGA_V

  • Service 22DID 2885
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2014 to 2016.

Motor-generator B voltage ELR_MGB_V

  • Service 22DID 2886
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2014 to 2016.

State of charge raw 2 ELR_ST_CHG_RAW_2

  • Service 22DID 2411
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100
Unit
Number

In testing for 2014 to 2016.

Modules › 01

HV battery module 01 voltage ELR_HVBAT_CMU01_VOLT

  • Service 22DID 4181
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 02

HV battery module 02 voltage ELR_HVBAT_CMU02_VOLT

  • Service 22DID 4182
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 03

HV battery module 03 voltage ELR_HVBAT_CMU03_VOLT

  • Service 22DID 4183
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 04

HV battery module 04 voltage ELR_HVBAT_CMU04_VOLT

  • Service 22DID 4184
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 05

HV battery module 05 voltage ELR_HVBAT_CMU05_VOLT

  • Service 22DID 4185
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 06

HV battery module 06 voltage ELR_HVBAT_CMU06_VOLT

  • Service 22DID 4186
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 07

HV battery module 07 voltage ELR_HVBAT_CMU07_VOLT

  • Service 22DID 4187
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 08

HV battery module 08 voltage ELR_HVBAT_CMU08_VOLT

  • Service 22DID 4188
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 09

HV battery module 09 voltage ELR_HVBAT_CMU09_VOLT

  • Service 22DID 4189
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 10

HV battery module 10 voltage ELR_HVBAT_CMU10_VOLT

  • Service 22DID 418A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 11

HV battery module 11 voltage ELR_HVBAT_CMU11_VOLT

  • Service 22DID 418B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 12

HV battery module 12 voltage ELR_HVBAT_CMU12_VOLT

  • Service 22DID 418C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 13

HV battery module 13 voltage ELR_HVBAT_CMU13_VOLT

  • Service 22DID 418D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 14

HV battery module 14 voltage ELR_HVBAT_CMU14_VOLT

  • Service 22DID 418E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 15

HV battery module 15 voltage ELR_HVBAT_CMU15_VOLT

  • Service 22DID 418F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 16

HV battery module 16 voltage ELR_HVBAT_CMU16_VOLT

  • Service 22DID 4190
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 17

HV battery module 17 voltage ELR_HVBAT_CMU17_VOLT

  • Service 22DID 4191
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 18

HV battery module 18 voltage ELR_HVBAT_CMU18_VOLT

  • Service 22DID 4192
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 19

HV battery module 19 voltage ELR_HVBAT_CMU19_VOLT

  • Service 22DID 4193
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 20

HV battery module 20 voltage ELR_HVBAT_CMU20_VOLT

  • Service 22DID 4194
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 21

HV battery module 21 voltage ELR_HVBAT_CMU21_VOLT

  • Service 22DID 4195
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 22

HV battery module 22 voltage ELR_HVBAT_CMU22_VOLT

  • Service 22DID 4196
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 23

HV battery module 23 voltage ELR_HVBAT_CMU23_VOLT

  • Service 22DID 4197
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 24

HV battery module 24 voltage ELR_HVBAT_CMU24_VOLT

  • Service 22DID 4198
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 25

HV battery module 25 voltage ELR_HVBAT_CMU25_VOLT

  • Service 22DID 4199
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 26

HV battery module 26 voltage ELR_HVBAT_CMU26_VOLT

  • Service 22DID 419A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 27

HV battery module 27 voltage ELR_HVBAT_CMU27_VOLT

  • Service 22DID 419B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 28

HV battery module 28 voltage ELR_HVBAT_CMU28_VOLT

  • Service 22DID 419C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 29

HV battery module 29 voltage ELR_HVBAT_CMU29_VOLT

  • Service 22DID 419D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 30

HV battery module 30 voltage ELR_HVBAT_CMU30_VOLT

  • Service 22DID 419E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 31

HV battery module 31 voltage ELR_HVBAT_CMU31_VOLT

  • Service 22DID 419F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 32

HV battery module 32 voltage ELR_HVBAT_CMU32_VOLT

  • Service 22DID 4200
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 33

HV battery module 33 voltage ELR_HVBAT_CMU33_VOLT

  • Service 22DID 4201
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 34

HV battery module 34 voltage ELR_HVBAT_CMU34_VOLT

  • Service 22DID 4202
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 35

HV battery module 35 voltage ELR_HVBAT_CMU35_VOLT

  • Service 22DID 4203
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 36

HV battery module 36 voltage ELR_HVBAT_CMU36_VOLT

  • Service 22DID 4204
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 37

HV battery module 37 voltage ELR_HVBAT_CMU37_VOLT

  • Service 22DID 4205
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 38

HV battery module 38 voltage ELR_HVBAT_CMU38_VOLT

  • Service 22DID 4206
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 39

HV battery module 39 voltage ELR_HVBAT_CMU39_VOLT

  • Service 22DID 4207
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 40

HV battery module 40 voltage ELR_HVBAT_CMU40_VOLT

  • Service 22DID 4208
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 41

HV battery module 41 voltage ELR_HVBAT_CMU41_VOLT

  • Service 22DID 4209
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 42

HV battery module 42 voltage ELR_HVBAT_CMU42_VOLT

  • Service 22DID 420A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 43

HV battery module 43 voltage ELR_HVBAT_CMU43_VOLT

  • Service 22DID 420B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 44

HV battery module 44 voltage ELR_HVBAT_CMU44_VOLT

  • Service 22DID 420C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 45

HV battery module 45 voltage ELR_HVBAT_CMU45_VOLT

  • Service 22DID 420D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 46

HV battery module 46 voltage ELR_HVBAT_CMU46_VOLT

  • Service 22DID 420E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 47

HV battery module 47 voltage ELR_HVBAT_CMU47_VOLT

  • Service 22DID 420F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 48

HV battery module 48 voltage ELR_HVBAT_CMU48_VOLT

  • Service 22DID 4210
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 49

HV battery module 49 voltage ELR_HVBAT_CMU49_VOLT

  • Service 22DID 4211
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 50

HV battery module 50 voltage ELR_HVBAT_CMU50_VOLT

  • Service 22DID 4212
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 51

HV battery module 51 voltage ELR_HVBAT_CMU51_VOLT

  • Service 22DID 4213
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 52

HV battery module 52 voltage ELR_HVBAT_CMU52_VOLT

  • Service 22DID 4214
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 53

HV battery module 53 voltage ELR_HVBAT_CMU53_VOLT

  • Service 22DID 4215
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 54

HV battery module 54 voltage ELR_HVBAT_CMU54_VOLT

  • Service 22DID 4216
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 55

HV battery module 55 voltage ELR_HVBAT_CMU55_VOLT

  • Service 22DID 4217
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 56

HV battery module 56 voltage ELR_HVBAT_CMU56_VOLT

  • Service 22DID 4218
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 57

HV battery module 57 voltage ELR_HVBAT_CMU57_VOLT

  • Service 22DID 4219
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 58

HV battery module 58 voltage ELR_HVBAT_CMU58_VOLT

  • Service 22DID 421A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 59

HV battery module 59 voltage ELR_HVBAT_CMU59_VOLT

  • Service 22DID 421B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 60

HV battery module 60 voltage ELR_HVBAT_CMU60_VOLT

  • Service 22DID 421C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 61

HV battery module 61 voltage ELR_HVBAT_CMU61_VOLT

  • Service 22DID 421D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 62

HV battery module 62 voltage ELR_HVBAT_CMU62_VOLT

  • Service 22DID 421E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 63

HV battery module 63 voltage ELR_HVBAT_CMU63_VOLT

  • Service 22DID 421F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 64

HV battery module 64 voltage ELR_HVBAT_CMU64_VOLT

  • Service 22DID 4220
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 65

HV battery module 65 voltage ELR_HVBAT_CMU65_VOLT

  • Service 22DID 4221
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 66

HV battery module 66 voltage ELR_HVBAT_CMU66_VOLT

  • Service 22DID 4222
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 67

HV battery module 67 voltage ELR_HVBAT_CMU67_VOLT

  • Service 22DID 4223
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 68

HV battery module 68 voltage ELR_HVBAT_CMU68_VOLT

  • Service 22DID 4224
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 69

HV battery module 69 voltage ELR_HVBAT_CMU69_VOLT

  • Service 22DID 4225
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 70

HV battery module 70 voltage ELR_HVBAT_CMU70_VOLT

  • Service 22DID 4226
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 71

HV battery module 71 voltage ELR_HVBAT_CMU71_VOLT

  • Service 22DID 4227
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 72

HV battery module 72 voltage ELR_HVBAT_CMU72_VOLT

  • Service 22DID 4228
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 73

HV battery module 73 voltage ELR_HVBAT_CMU73_VOLT

  • Service 22DID 4229
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 74

HV battery module 74 voltage ELR_HVBAT_CMU74_VOLT

  • Service 22DID 422A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 75

HV battery module 75 voltage ELR_HVBAT_CMU75_VOLT

  • Service 22DID 422B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 76

HV battery module 76 voltage ELR_HVBAT_CMU76_VOLT

  • Service 22DID 422C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 77

HV battery module 77 voltage ELR_HVBAT_CMU77_VOLT

  • Service 22DID 422D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 78

HV battery module 78 voltage ELR_HVBAT_CMU78_VOLT

  • Service 22DID 422E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 79

HV battery module 79 voltage ELR_HVBAT_CMU79_VOLT

  • Service 22DID 422F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 80

HV battery module 80 voltage ELR_HVBAT_CMU80_VOLT

  • Service 22DID 4230
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 81

HV battery module 81 voltage ELR_HVBAT_CMU81_VOLT

  • Service 22DID 4231
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 82

HV battery module 82 voltage ELR_HVBAT_CMU82_VOLT

  • Service 22DID 4232
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 83

HV battery module 83 voltage ELR_HVBAT_CMU83_VOLT

  • Service 22DID 4233
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 84

HV battery module 84 voltage ELR_HVBAT_CMU84_VOLT

  • Service 22DID 4234
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 85

HV battery module 85 voltage ELR_HVBAT_CMU85_VOLT

  • Service 22DID 4235
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 86

HV battery module 86 voltage ELR_HVBAT_CMU86_VOLT

  • Service 22DID 4236
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 87

HV battery module 87 voltage ELR_HVBAT_CMU87_VOLT

  • Service 22DID 4237
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 88

HV battery module 88 voltage ELR_HVBAT_CMU88_VOLT

  • Service 22DID 4238
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 89

HV battery module 89 voltage ELR_HVBAT_CMU89_VOLT

  • Service 22DID 4239
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 90

HV battery module 90 voltage ELR_HVBAT_CMU90_VOLT

  • Service 22DID 423A
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 91

HV battery module 91 voltage ELR_HVBAT_CMU91_VOLT

  • Service 22DID 423B
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 92

HV battery module 92 voltage ELR_HVBAT_CMU92_VOLT

  • Service 22DID 423C
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 93

HV battery module 93 voltage ELR_HVBAT_CMU93_VOLT

  • Service 22DID 423D
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 94

HV battery module 94 voltage ELR_HVBAT_CMU94_VOLT

  • Service 22DID 423E
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 95

HV battery module 95 voltage ELR_HVBAT_CMU95_VOLT

  • Service 22DID 423F
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Modules › 96

HV battery module 96 voltage ELR_HVBAT_CMU96_VOLT

  • Service 22DID 4240
  • Module7E7 → 7EF
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×565535
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

Clocks

Time since engine start ELR_RUNTM

  • Service 22DID 11A1
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2014 to 2016.

Control

Brake torque ELR_BRAKE_TQ

  • Service 22DID 242C
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 N·m
Unit
N·m

In testing for 2014 to 2016.

Front left wheel speed ELR_FL_WHL_SPD

  • Service 22DID 4051
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016.

Front right wheel speed ELR_FR_WHL_SPD

  • Service 22DID 4052
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016.

Rear left wheel speed ELR_RL_WHL_SPD

  • Service 22DID 4054
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016.

Rear right wheel speed ELR_RR_WHL_SPD

  • Service 22DID 4053
  • Module760 → 768
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016.

Drivetrain

Motor-generator A temperature ELR_MGA_T

  • Service 22DID 28CB
  • Module257 → 657
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Motor-generator B temperature ELR_MGB_T

  • Service 22DID 368F
  • Module258 → 658
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Electrical

Power electronics coolant temperature ELR_PEM_T

  • Service 22DID 1C43
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Engine

1-2 shift error ELR_1_2_SHIFT_ERROR

  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

1-2 shift time ELR_1_2_SHIFT_TIME

  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

2-3 shift error ELR_2_3_SHIFT_ERROR

  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

2-3 shift time ELR_2_3_SHIFT_TIME

  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

3-4 shift error ELR_3_4_SHIFT_ERROR

  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

3-4 shift time ELR_3_4_SHIFT_TIME

  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

A/C low side pressure ELR_AC_LOW_SIDE

  • Service 22DID 1563
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2016.

Air conditioning high side pressure ELR_AC_HIGH_SIDE_P

  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2.02
Range
0 to 515.1 psi
Unit
psi

In testing for 2014 to 2016.

Air filter life remaining ELR_AIRFILT_LIFE

  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Air temperature 1 ELR_AIR_T_1

  • Service 22DID 801E
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2014 to 2016.

Air temperature 2 ELR_AIR_T_2

  • Service 22DID 801F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2014 to 2016.

Air/fuel ratio, commanded ELR_AIR_FUEL_RAT_CMD

  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 1 ELR_BALANCE_RATE_CYL_1

  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 2 ELR_BALANCE_RATE_CYL_2

  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 3 ELR_BALANCE_RATE_CYL_3

  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 4 ELR_BALANCE_RATE_CYL_4

  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 5 ELR_BALANCE_RATE_CYL_5

  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 6 ELR_BALANCE_RATE_CYL_6

  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 7 ELR_BALANCE_RATE_CYL_7

  • Service 22DID 1635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Balance rate, cylinder 8 ELR_BALANCE_RATE_CYL_8

  • Service 22DID 1636
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64−512
Range
-512 to 511
Unit
Number

In testing for 2014 to 2016.

Barometric pressure, V6 ELR_BAROMETRIC_P_V6

  • Service 22DID 1251
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2016.

Barometric pressure, V8 ELR_BAROMETRIC_P_V8

  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2014 to 2016.

Battery temperature 2416 ELR_BATT_T_2416

  • Service 22DID 2416
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Battery temperature 2417 ELR_BATT_T_2417

  • Service 22DID 2417
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Boost pressure: actual ELR_BP_ACT

  • Service 22DID 20E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 2014 to 2016.

Boost pressure: desired ELR_BP_DES

  • Service 22DID 328A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 kPa
Unit
kPa

In testing for 2014 to 2016.

Calculated engine oil pressure ELR_EOP_CALC

  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2014 to 2016.

Calculated engine oil temperature ELR_EOT_CALC

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Charging limit ? ELR_CHG_LIM

  • Service 22DID 41B7
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 W
Unit
W

In testing for 2014 to 2016.

Cooling fan command ELR_COOLING_FAN_CMD

  • Service 22DID 3812
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Cooling fan motor command ELR_COOLING_FAN_MOTOR_CMD

  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Engine oil absolute pressure ELR_EOP_ABS

  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2014 to 2016.

Engine oil life remaining ELR_EO_LIFE_REMAINING

  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Engine oil pressure ELR_EOP

  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2014 to 2016.

Engine oil pressure ELR_EOP_DA11

  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×400100
Range
0 to 1020 kPa
Unit
kPa

In testing for 2014 to 2016.

Engine oil pressure 2 ELR_EOP_2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×35−21.6
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 2014 to 2016.

Engine oil pressure control solenoid valve command ELR_EOP_CTRL_SOLENOID_VALVE_CMD

  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2014 to 2016.

Engine oil temperature ELR_EOT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Engine oil temperature ELR_EOT_DA11

  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
0 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Engine torque ELR_ENG_TQ

  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2014 to 2016.

Engine torque ELR_ENG_TQ_7E0

  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 N·m
Unit
N·m

In testing for 2014 to 2016.

EV trip this drive cycle ELR_EV_TRIP_THIS_DRIVE

  • Service 22DID 2487
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 km
Unit
km

In testing for 2014 to 2016.

Evaporative emissions purge ELR_EVAPORATIVE

  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Exhaust gas recirculation duty cycle ELR_EGR_DUTY

  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.55
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Exhaust gas recirculation voltage ELR_EGR_V

  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val51
Range
0 to 5 V
Unit
V

In testing for 2014 to 2016.

H2 electronics temperature ELR_H2_ELECTRONICS_T

  • Service 22DID 1C43
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Heated oxygen sensor ELR_HEATED_OXYGEN_SENS

  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 2014 to 2016.

Heater - cabin ELR_HEATER_CABIN

  • Service 22DID 41B4
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 W
Unit
W

In testing for 2014 to 2016.

High voltage current ELR_HIGH_V_CURRENT

  • Service 22DID 2414
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val20
Range
-1638 to 1638 A
Unit
A

In testing for 2014 to 2016.

High voltage current HD ELR_HIGH_V_CURRENT_HD

  • Service 22DID 4356
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×-5003333
Range
-4915 to 4915 A
Unit
A

In testing for 2014 to 2016.

Idle air control position ELR_IDLE_AIR_CTRL_POS

  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Injector duty cycle bank 1 ELR_INJECTOR_DUTY_CYCLE_BANK_1

  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 2014 to 2016.

Injector duty cycle bank 2 ELR_INJECTOR_DUTY_CYCLE_BANK_2

  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×15010000
Range
0 to 983.025 ms
Unit
ms

In testing for 2014 to 2016.

Injector pulse width, cylinder 1 ELR_INJ_WIDTH_CYL_1

  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Injector pulse width, cylinder 7 ELR_INJ_WIDTH_CYL_7

  • Service 22DID 1199
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Injector pulse width, cylinder 8 ELR_INJ_WIDTH_CYL_8

  • Service 22DID 129A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val65.535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Intake air temperature 2 ELR_IAT_2

  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Knock retard ELR_KNOCK_RETARD

  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×22100
Range
0 to 56.1 °
Unit
°

In testing for 2014 to 2016.

Knock retard, alternate ELR_KNOCK_RETARD_ALT

  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 2014 to 2016.

Knock sensor active counter ELR_KNOCK_SENS_ACTIVE

  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Last shift time ELR_LAST_SHIFT_TIME

  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val40
Range
0 to 6.375 s
Unit
s

In testing for 2014 to 2016.

Mass airflow sensor ELR_MAF

  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×10010000
Range
0 to 655.35 g/s
Unit
g/s

In testing for 2014 to 2016.

Misfire current, cylinder 7 ELR_MIS_CURRENT_7

  • Service 22DID 11EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfire current, cylinder 8 ELR_MIS_CURRENT_8

  • Service 22DID 11ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 1 ELR_MIS_HISTORY_1

  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 2 ELR_MIS_HISTORY_2

  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 3 ELR_MIS_HISTORY_3

  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 4 ELR_MIS_HISTORY_4

  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 5 ELR_MIS_HISTORY_5

  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 6 ELR_MIS_HISTORY_6

  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 7 ELR_MIS_HISTORY_7

  • Service 22DID 11FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfire history, cylinder 8 ELR_MIS_HISTORY_8

  • Service 22DID 11FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 1 ELR_MISFIRES_C1_CUR

  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 2 ELR_MISFIRES_C2_CUR

  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 3 ELR_MISFIRES_C3_CUR

  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 4 ELR_MISFIRES_C4_CUR

  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 5 ELR_MISFIRES_C5_CUR

  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Misfires, current, cylinder 6 ELR_MISFIRES_C6_CUR

  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Motor-generator A current ELR_MGA_CURRENT

  • Service 22DID 2883
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2014 to 2016.

Motor-generator B current ELR_MGB_CURRENT

  • Service 22DID 2884
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2014 to 2016.

Outside air temperature ELR_AAT

  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Particulate matter sensor soot accumulation ELR_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION

  • Service 22DID 3635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×10010000
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Particulate matter sensor temperature ELR_PARTICULATE_MATTER_SNS_T

  • Service 22DID 3372
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100010000
Range
0 to 6553.5 °C
Unit
°C

In testing for 2014 to 2016.

Pressure control solenoid current, actual ELR_P_CTRL_SOLENOID_ACT

  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2016.

Pressure control solenoid current, reference ELR_P_CTRL_SOLENOID

  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2014 to 2016.

Remaining oil life ELR_REMAINING_OIL_LIFE

  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2014 to 2016.

Total knock retard ELR_TOTAL_KNOCK_RETARD

  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×45100
Range
0 to 114.75 °
Unit
°

In testing for 2014 to 2016.

Total misfire ELR_TOTAL_MISFIRE

  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Transmission fluid temperature ELR_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID 1940
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 1 ELR_ATF_T_VAR_1

  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 3 ELR_ATF_T_VAR_3

  • Service 22DID 1940
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 5 ELR_ATF_T_VAR_5

  • Service 22DID 1940
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 6 ELR_ATF_T_VAR_6

  • Service 22DID 280D
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 7 ELR_ATF_T_VAR_7

  • Service 22DID 280D
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission fluid temperature, variant 8 ELR_ATF_T_VAR_8

  • Service 22DID 280D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Vent temperature ELR_VENT_T

  • Service 22DID 82B2
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val8−10
Range
-10 to 21.87 °C
Unit
°C

In testing for 2014 to 2016.

Fuel

Ethanol content of fuel ELR_ETHANOL_CONTENT_FUEL

  • Service 22DID 0052
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Fuel consumption rate ELR_FUEL_RATE

  • Service 22DID 005E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×50010000
Range
0 to 3276.75 L
Unit
L

In testing for 2014 to 2016.

Fuel injection, cylinder 1 ELR_FUEL_INJECTION_C1

  • Service 22DID 20AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 2 ELR_FUEL_INJECTION_C2

  • Service 22DID 1194
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 3 ELR_FUEL_INJECTION_C3

  • Service 22DID 1195
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 4 ELR_FUEL_INJECTION_C4

  • Service 22DID 1196
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 5 ELR_FUEL_INJECTION_C5

  • Service 22DID 1197
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 6 ELR_FUEL_INJECTION_C6

  • Service 22DID 1198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×100065535
Range
0 to 1000 ms
Unit
ms

In testing for 2014 to 2016.

Fuel injection, cylinder 8 ELR_FUEL_INJECTION_C8

  • Service 22DID 20B3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1010000
Range
0 to 65.535 ms
Unit
ms

In testing for 2014 to 2016.

Fuel remaining ELR_FLI

Pelican can show this parameter as the fuel tank level.

  • Service 22DID 002F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2014 to 2016.

Fuel tank pressure ELR_FUEL_TANK_P

  • Service 22DID F432
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val33333.33333
Range
0 to 1.96 psi
Unit
psi

In testing for 2014 to 2016.

Fuel temperature ELR_FUEL_T

  • Service 22DID 3218
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×50100
Range
0 to 127.5 °C
Unit
°C

In testing for 2014 to 2016.

Total fuel consumption rate ELR_TOTAL_FUEL_CONSUMPTION_RATE

  • Service 22DID 009D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×20010000
Range
0 to 1310.7 g/s
Unit
g/s

In testing for 2014 to 2016.

Movement

AT output shaft speed ELR_OUTPUT_SHFT_SPD_7E1

  • Service 22DID 1942
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2014 to 2016.

Battery coolant pump speed ELR_BATT_CLT_PMP_RPM

  • Service 22DID 41B2
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2014 to 2016.

Desired idle speed ELR_DES_IDLE_SPD

  • Service 22DID 1192
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×12.5
Range
0 to 3187.5 rpm
Unit
rpm

In testing for 2014 to 2016.

Output shaft speed ELR_OUTPUT_SHFT_SPD

  • Service 22DID 1942
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 rpm
Unit
rpm

In testing for 2014 to 2016.

Torque converter clutch slip speed ELR_TC_SLIP_VSS

  • Service 22DID 1991
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×125010000
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2014 to 2016.

Torque converter clutch slip speed ELR_TQ_CONV_CLU_SLIP_SPD

  • Service 22DID 1991
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val8
Range
-4096 to 4095.875 rpm
Unit
rpm

In testing for 2014 to 2016.

Vehicle speed ELR_VSS

Pelican can show this parameter as the speed.

  • Service 22DID 000D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2014 to 2016.

Tires

Left front tire pressure ELR_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID 248E
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2014 to 2016.

Left rear tire pressure ELR_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID 2491
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2014 to 2016.

Right front tire pressure ELR_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID 248F
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2014 to 2016.

Right rear tire pressure ELR_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID 2490
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2014 to 2016.

Transmission

Clutch slip, AT C1, ring ELR_CLU_SLIP_C1_RING

  • Service 22DID 2851
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2014 to 2016.

Clutch slip, AT C3, ring ELR_CLU_SLIP_C3_RING

  • Service 22DID 19D4
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2014 to 2016.

Current gear ELR_CURRENT_GEAR

  • Service 22DID 1B30
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−3
Range
-3 to 252
Unit
Number

In testing for 2014 to 2016.

Current gear ELR_CURRENT_GEAR_7E0

  • Service 22DID 199A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Current gear, variant 2 ELR_CURRENT_GEAR_VAR_2

  • Service 22DID 199A
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Current gear, variant 3 ELR_CURRENT_GEAR_VAR_3

  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Gear ratio ELR_GEAR_RAT

  • Service 22DID 19A1
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Gear, AT position ELR_GEAR_POS

  • Service 22DID 2889
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2016.

Transmission fluid temperature, filtered ELR_TF_T_FLTED

  • Service 22DID 295A
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2014 to 2016.

Transmission input shaft speed ELR_TRANS_INPUT_SHFT_SPD

  • Service 22DID 1941
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 rpm
Unit
rpm

In testing for 2014 to 2016.

Transmission input shaft speed, 2 ELR_TRANS_ISS

  • Service 22DID 1941
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 rpm
Unit
rpm

In testing for 2014 to 2016.

Transmission pressure ELR_TRANS_P

  • Service 22DID 2862
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2014 to 2016.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.