BMW iX2

Parameters

The BMW iX2 has 380 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Aging factor BMW_HVBAT_IMPEDANCE_ALPHA

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Aging factor BMW_HVBAT_IMPEDANCE_ALPHA

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

In testing for 2024 to 2026.

Battery capacity BMW_BAT_CAP

  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2024 to 2026.

Battery state of charge current BMW_BAT_ST_CHG_CURRENT

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge last-1 BMW_BAT_ST_CHG_LAST_1

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge last-2 BMW_BAT_ST_CHG_LAST_2

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge last-3 BMW_BAT_ST_CHG_LAST_3

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge last-4 BMW_BAT_ST_CHG_LAST_4

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery state of charge last-5 BMW_BAT_ST_CHG_LAST_5

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Battery time in invalid state of charge BMW_BAT_TIME_INVALID_ST

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 0-40% BMW_BAT_TIME_ST_CHG_0_40

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 40-60% BMW_BAT_TIME_ST_CHG_40_60

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 60-70% BMW_BAT_TIME_ST_CHG_60_70

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 70-80% BMW_BAT_TIME_ST_CHG_70_80

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 80-90% BMW_BAT_TIME_ST_CHG_80_90

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery time in state of charge 90-100% BMW_BAT_TIME_ST_CHG_90_100

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2024 to 2026.

Battery voltage BMW_BAT_V

  • Service 22DID E54D
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655 V
Unit
V

In testing for 2024 to 2026.

Battery voltage (battery sensor) BMW_IBS_VOLTAGE

  • Service 22DID 5853
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

Cell capacity, average BMW_HVBAT_C_CAP_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell capacity, max BMW_HVBAT_C_CAP_MAX

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell capacity, min BMW_HVBAT_C_CAP_MIN

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2024 to 2026.

Cell OCV, average BMW_HVBAT_C_OCV_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Cell OCV, max BMW_HVBAT_C_OCV_MAX

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Cell OCV, min BMW_HVBAT_C_OCV_MIN

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Cell resistance factor, average BMW_HVBAT_C_RES_FACTOR_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

In testing for 2024 to 2026.

Cell resistance factor, max BMW_HVBAT_C_RES_FACTOR_MAX

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

In testing for 2024 to 2026.

Cell resistance factor, min BMW_HVBAT_C_RES_FACTOR_MIN

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535
Unit
Number

In testing for 2024 to 2026.

Cell state of charge, average BMW_HVBAT_C_SOC_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2024 to 2026.

Cell state of charge, max BMW_HVBAT_C_SOC_MAX_V2

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2024 to 2026.

Cell state of charge, min BMW_HVBAT_C_SOC_MIN_V2

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 %
Unit
%

In testing for 2024 to 2026.

Cell temperature, average BMW_HVBAT_C_TEMP_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

Cell temperature, max BMW_HVBAT_C_TEMP_MAX

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

Cell temperature, min BMW_HVBAT_C_TEMP_MIN

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

Cell voltage, average BMW_HVBAT_C_V_AVG

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Cell voltage, max BMW_HVBAT_C_V_MAX

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Cell voltage, min BMW_HVBAT_C_V_MIN

  • Service 22DID DFA0
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10000
Range
0 to 6.5535 V
Unit
V

In testing for 2024 to 2026.

Charge port light state BMW_CHG_LED

  • Service 22DID DEF3
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Charging interface ready BMW_CHG_READY

  • Service 22DID DEF2
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

DC charge contactor state BMW_DC_CONTACTOR

  • Service 22DID DEF8
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

DC charge control 1 BMW_DC_CTRL_1

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

DC charge control 2 BMW_DC_CTRL_2

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

DC charge permission BMW_DC_PERMIT

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

DC charge plug connected BMW_DC_PLUG

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

High voltage battery current BMW_HVBAT_CURRENT

  • Service 22DID E561
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×-1100
Range
-327 to 327 A
Unit
A

In testing for 2024 to 2026.

Highest cell state of charge BMW_HVBAT_C_SOC_MAX

  • Service 22DID E5CE
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery cell 1 voltage BMW_HVBAT_CELL_V_01

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 2 voltage BMW_HVBAT_CELL_V_02

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 3 voltage BMW_HVBAT_CELL_V_03

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 4 voltage BMW_HVBAT_CELL_V_04

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 5 voltage BMW_HVBAT_CELL_V_05

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 6 voltage BMW_HVBAT_CELL_V_06

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 7 voltage BMW_HVBAT_CELL_V_07

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 8 voltage BMW_HVBAT_CELL_V_08

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 9 voltage BMW_HVBAT_CELL_V_09

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 10 voltage BMW_HVBAT_CELL_V_10

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 11 voltage BMW_HVBAT_CELL_V_11

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 12 voltage BMW_HVBAT_CELL_V_12

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 13 voltage BMW_HVBAT_CELL_V_13

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 14 voltage BMW_HVBAT_CELL_V_14

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 15 voltage BMW_HVBAT_CELL_V_15

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 16 voltage BMW_HVBAT_CELL_V_16

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 17 voltage BMW_HVBAT_CELL_V_17

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 18 voltage BMW_HVBAT_CELL_V_18

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 19 voltage BMW_HVBAT_CELL_V_19

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 20 voltage BMW_HVBAT_CELL_V_20

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 21 voltage BMW_HVBAT_CELL_V_21

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 22 voltage BMW_HVBAT_CELL_V_22

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 23 voltage BMW_HVBAT_CELL_V_23

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 24 voltage BMW_HVBAT_CELL_V_24

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 25 voltage BMW_HVBAT_CELL_V_25

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 26 voltage BMW_HVBAT_CELL_V_26

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 27 voltage BMW_HVBAT_CELL_V_27

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 28 voltage BMW_HVBAT_CELL_V_28

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 29 voltage BMW_HVBAT_CELL_V_29

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 30 voltage BMW_HVBAT_CELL_V_30

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 31 voltage BMW_HVBAT_CELL_V_31

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 32 voltage BMW_HVBAT_CELL_V_32

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 33 voltage BMW_HVBAT_CELL_V_33

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 34 voltage BMW_HVBAT_CELL_V_34

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 35 voltage BMW_HVBAT_CELL_V_35

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 36 voltage BMW_HVBAT_CELL_V_36

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 37 voltage BMW_HVBAT_CELL_V_37

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 38 voltage BMW_HVBAT_CELL_V_38

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 39 voltage BMW_HVBAT_CELL_V_39

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 40 voltage BMW_HVBAT_CELL_V_40

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 41 voltage BMW_HVBAT_CELL_V_41

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 42 voltage BMW_HVBAT_CELL_V_42

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 43 voltage BMW_HVBAT_CELL_V_43

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 44 voltage BMW_HVBAT_CELL_V_44

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 45 voltage BMW_HVBAT_CELL_V_45

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 46 voltage BMW_HVBAT_CELL_V_46

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 47 voltage BMW_HVBAT_CELL_V_47

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 48 voltage BMW_HVBAT_CELL_V_48

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 49 voltage BMW_HVBAT_CELL_V_49

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 50 voltage BMW_HVBAT_CELL_V_50

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 51 voltage BMW_HVBAT_CELL_V_51

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 52 voltage BMW_HVBAT_CELL_V_52

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 53 voltage BMW_HVBAT_CELL_V_53

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 54 voltage BMW_HVBAT_CELL_V_54

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 55 voltage BMW_HVBAT_CELL_V_55

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 56 voltage BMW_HVBAT_CELL_V_56

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 57 voltage BMW_HVBAT_CELL_V_57

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 58 voltage BMW_HVBAT_CELL_V_58

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 59 voltage BMW_HVBAT_CELL_V_59

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 60 voltage BMW_HVBAT_CELL_V_60

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 61 voltage BMW_HVBAT_CELL_V_61

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 62 voltage BMW_HVBAT_CELL_V_62

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 63 voltage BMW_HVBAT_CELL_V_63

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 64 voltage BMW_HVBAT_CELL_V_64

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 65 voltage BMW_HVBAT_CELL_V_65

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 66 voltage BMW_HVBAT_CELL_V_66

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 67 voltage BMW_HVBAT_CELL_V_67

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 68 voltage BMW_HVBAT_CELL_V_68

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 69 voltage BMW_HVBAT_CELL_V_69

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 70 voltage BMW_HVBAT_CELL_V_70

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 71 voltage BMW_HVBAT_CELL_V_71

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 72 voltage BMW_HVBAT_CELL_V_72

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 73 voltage BMW_HVBAT_CELL_V_73

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 74 voltage BMW_HVBAT_CELL_V_74

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 75 voltage BMW_HVBAT_CELL_V_75

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 76 voltage BMW_HVBAT_CELL_V_76

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 77 voltage BMW_HVBAT_CELL_V_77

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell 78 voltage BMW_HVBAT_CELL_V_78

  • Service 22DID E554
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell temperature, average BMW_HVBAT_CT_AVG

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

HV battery cell temperature, max BMW_HVBAT_CT_MAX

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

HV battery cell temperature, min BMW_HVBAT_CT_MIN

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

HV battery cell voltage, max BMW_HVBAT_CELL_V_MAX_V2

  • Service 22DID E553
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery cell voltage, min BMW_HVBAT_CELL_V_MIN_V2

  • Service 22DID E553
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

In testing for 2024 to 2026.

HV battery charge BMW_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery charge BMW_HVBAT_SOC_6F1

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery charge BMW_HVBAT_SOC_V2

Pelican can show this parameter as the state of charge.

  • Service 22DID E5CE
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery charge, max BMW_HVBAT_SOC_MAX

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery charge, min BMW_HVBAT_SOC_MIN

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery current BMW_HVBAT_C

Pelican can show this parameter as the traction battery current.

  • Service 22DID DD69
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-10000 to 10000 A
Unit
A

In testing for 2024 to 2026.

HV battery current BMW_HVBAT_CURR

  • Service 22DID DD69
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val100
Range
-10000 to 10000 A
Unit
A

In testing for 2024 to 2026.

HV battery energy capacity BMW_HVBAT_E_CAP

Pelican can show this parameter as the traction battery capacity.

  • Service 22DID E5C7
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100−50
Range
0 to 605.35 kWh
Unit
kWh

In testing for 2024 to 2026.

HV battery energy stored BMW_HVBAT_E_STORED

  • Service 22DID E5C7
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100−50
Range
0 to 605.35 kWh
Unit
kWh

In testing for 2024 to 2026.

HV battery health BMW_HVBAT_SOH

Pelican can show this parameter as the state of health.

  • Service 22DID 6335
  • Module6F1 → 607
  • Every3600 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery health BMW_HVBAT_SOH_V2

Pelican can show this parameter as the state of health.

  • Service 22DID E5C7
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

HV battery temperature BMW_HVBAT_T

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

In testing for 2024 to 2026.

HV battery voltage BMW_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID E54D
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2024 to 2026.

HV battery voltage BMW_HVBAT_VOLT

  • Service 22DID DD68
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2024 to 2026.

HV voltage, second reading BMW_HVBAT_V_2

  • Service 22DID E54A
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2024 to 2026.

HV voltage, third reading BMW_HVBAT_V_3

  • Service 22DID E54B
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 V
Unit
V

In testing for 2024 to 2026.

Is charger connected BMW_HVBAT_CHG_CON

Pelican can show this parameter as the plug state.

  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2024 to 2026.

Is charging BMW_HVBAT_CHG_CON_EXT

Pelican can show this parameter as the charging state.

  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2024 to 2026.

Lowest cell state of charge BMW_HVBAT_C_SOC_MIN

  • Service 22DID E5CE
  • Module6F1 → 607
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Minimum state of charge BMW_HVBAT_HVPM_MIN_SOC

  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Number of cells BMW_HVBAT_C_CNT

  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Number of cells per module BMW_HVBAT_C_CNT_MOD

  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Number of modules BMW_HVBAT_MOD_CNT

  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Number of temperature sensors per module BMW_HVBAT_MOD_T_CNT

  • Service 22DID DF71
  • Module6F1 → 607
  • Every86400 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Original battery capacity BMW_ORIGINAL_BAT_CAP

  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2024 to 2026.

Ready to drive BMW_HVBAT_CHG_RDY

  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2024 to 2026.

State of charge, power module BMW_HVBAT_HVPM_SOC

Battery level reading from the high voltage power module

  • Service 22DID DE00
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Climate

A/C compressor operating state BMW_COMP_STATE

  • Service 22DID D8C5
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Ambient air temperature BMW_AAT

  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2024 to 2026.

Ambient air temperature BMW_AAT_V2

  • Service 22DID D112
  • Module6F1 → 663
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

In testing for 2024 to 2026.

Front air distribution, left BMW_AIR_DIST_L

  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Front air distribution, right BMW_AIR_DIST_R

  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Control

Brake pressure BMW_BRAKE_P

  • Service 22DID DBE5
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 bar
Unit
bar

In testing for 2024 to 2026.

Brake switch BMW_BRAKE_SWITCH

  • Service 22DID DA28
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2024 to 2026.

Parking brake applied BMW_PARK_BRAKE

  • Service 22DID D130
  • Module6F1 → 640
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Doors

Charge flap closed BMW_CHG_FLAP_CLOSED

  • Service 22DID DEF1
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2024 to 2026.

Driver door open BMW_DOOR_DRIVER

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Hood open BMW_HOOD

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Locked BMW_CENTRAL_LOCK

Overall lock state of the vehicle

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Passenger door open BMW_DOOR_PASSENGER

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Rear driver door open BMW_DOOR_DRIVER_REAR

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Rear passenger door open BMW_DOOR_PASSENGER_REAR

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Trunk open BMW_TRUNK

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Electrical

12V battery current BMW_12V_A

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val12.5−200
Range
-200 to 5042.8 A
Unit
A

In testing for 2024 to 2026.

12V battery temperature BMW_12V_T

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2024 to 2026.

12V battery voltage BMW_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val4000+6
Range
6 to 22.3837 V
Unit
V

In testing for 2024 to 2026.

Engine

Accelerator pedal position BMW_APP

  • Service 22DID DE9C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2024 to 2026.

Air conditioning compressor PWM BMW_AC_COMP_PWM

  • Service 22DID D906
  • Module6F1 → 640
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Air conditioning compressor status BMW_AC_COMP_STAT

  • Service 22DID D906
  • Module6F1 → 640
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

AT engine torque BMW_ENG_TQ

  • Service 21PID 08
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2024 to 2026.

Automatic air recirculation BMW_HVAC_AUC

  • Service 22DID D930
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Automatic transmission fluid temperature BMW_ATF_T

  • Service 21PID 0A
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Automatic transmission fluid temperature BMW_ATF_TEMP

Pelican can show this parameter as the transmission fluid temperature.

  • Service 22DID DA12
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−48
Range
-48 to 250 °C
Unit
°C

In testing for 2024 to 2026.

Barometric pressure BMW_BARO

  • Service 22DID 4201
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2024 to 2026.

Boost pressure BMW_BOOST_P

  • Service 22DID 4205
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2024 to 2026.

Boost pressure, set point BMW_BOOST_P_SET

  • Service 22DID 4AB0
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2024 to 2026.

Cabin temperature BMW_CABIN_T

  • Service 22DID D85C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Catalyst temperature BMW_CAT_T

  • Service 22DID 582F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Charge cycle efficiency BMW_OBC_EFF_CYCLE

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Charger 12V supply voltage BMW_OBC_KL30_V

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2024 to 2026.

Charger AC current, phase 1 BMW_OBC_AC_I_1

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2024 to 2026.

Charger AC current, phase 2 BMW_OBC_AC_I_2

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2024 to 2026.

Charger AC current, phase 3 BMW_OBC_AC_I_3

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2024 to 2026.

Charger AC voltage, phase 1 BMW_OBC_AC_V_1

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2024 to 2026.

Charger AC voltage, phase 2 BMW_OBC_AC_V_2

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2024 to 2026.

Charger AC voltage, phase 3 BMW_OBC_AC_V_3

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2024 to 2026.

Charger DC efficiency BMW_OBC_EFF_DC

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Charger grid frequency, phase 1 BMW_OBC_GRID_HZ

  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 Hz
Unit
Hz

In testing for 2024 to 2026.

Charger HV DC current BMW_OBC_HV_I

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−204.7
Range
-204 to 6348 A
Unit
A

In testing for 2024 to 2026.

Charger HV DC voltage BMW_OBC_HV_V

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2024 to 2026.

Charger HV output power BMW_OBC_PWR

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2024 to 2026.

Charger power reduction BMW_OBC_DERATING

  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Charging cable current rating BMW_CHG_CABLE_I

  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2024 to 2026.

Charging current the pilot signal allows BMW_CHG_PILOT_I

  • Service 22DID DEF6
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2024 to 2026.

Charging pilot duty cycle BMW_CHG_PILOT_DUTY

  • Service 22DID DEF6
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Charging pilot signal active BMW_CHG_PILOT_ACT

  • Service 22DID DEF6
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Charging plug state BMW_CHG_PLUG_ST

  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Climate control off BMW_HVAC_OFF

  • Service 22DID D92C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Consumption, kwh/100km BMW_CONS_KWH_100KM

  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2024 to 2026.

Coolant temperature BMW_COOLANT

  • Service 22DID 411E
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Crank torque BMW_CRANK_TQ

  • Service 22DID 58BA
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 2024 to 2026.

Current calibration angle BMW_CURRENT_CALIBRATION

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val64
Range
0 to 1023 °
Unit
°

In testing for 2024 to 2026.

DC charging pin cover open BMW_DC_PIN_COVER

  • Service 22DID DEFA
  • Module6F1 → 614
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Drive electronics processor 0 temperature BMW_EME_T_MC0

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive electronics processor 2 temperature BMW_EME_T_MC2

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive inverter gate driver temperature BMW_INV_T_GATE

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive inverter HV DC current BMW_EM_INV_I_DC

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2024 to 2026.

Drive inverter phase u temperature BMW_INV_T_U

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive inverter phase v temperature BMW_INV_T_V

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive inverter phase w temperature BMW_INV_T_W

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor excitation current BMW_EM_I_EXC

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2024 to 2026.

Drive motor phase u current BMW_EM_I_U

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2024 to 2026.

Drive motor phase v current BMW_EM_I_V

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2024 to 2026.

Drive motor phase w current BMW_EM_I_W

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2024 to 2026.

Drive motor speed BMW_EM_RPM

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−5000
Range
-5000 to 27767 rpm
Unit
rpm

In testing for 2024 to 2026.

Drive motor temperature 1 BMW_EM_T_1

  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor temperature 2 BMW_EM_T_2

  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor torque, actual BMW_EM_TQ

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2024 to 2026.

Drive motor torque, requested BMW_EM_TQ_TGT

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2024 to 2026.

Emission-relevant misfires, all cylinders BMW_MISFIRE_CNT_TOTAL

  • Service 22DID 58DB
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Engine coolant temperature BMW_ECT_DME

  • Service 22DID 5805
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Engine load BMW_LOAD

  • Service 22DID 5813
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 %
Unit
%

In testing for 2024 to 2026.

Engine load 2 BMW_LOAD_2

  • Service 22DID 4A4B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Engine load, target BMW_LOAD_TGT

  • Service 22DID 480C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3128
Range
0 to 1535 %
Unit
%

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT

  • Service 22DID DA25
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val−48
Range
-500 to 500 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT_6F1

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4402
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT_8

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4402
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−60
Range
-60 to 195 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT_DME

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT_DME_K

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_EOT_DME_K10

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 382.2 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_OIL_TEMP

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4506
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature BMW_OIL_TEMP_16

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4506
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature (engine computer) BMW_EOT_DME_V2

  • Service 22DID 5822
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−48
Range
-48 to 207 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature sensor, raw BMW_OIL_TEMP_RAW

  • Service 22DID 4506
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Engine oil temperature, alternate BMW_OIL_TEMP_ALT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 57C3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Engine temperature BMW_ET

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 4300
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Engine temperature BMW_ET_8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 4300
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2024 to 2026.

Engine torque BMW_ENG_TQ_6F1

  • Service 22DID 442F
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2024 to 2026.

Exhaust gas calculated temperature BMW_EGT_CALC

  • Service 22DID 4C5B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 1200 °C
Unit
°C

In testing for 2024 to 2026.

Front axle target torque BMW_FRONT_AXLE_TGT_TQ

  • Service 22DID DB32
  • Module6F1 → 619
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 N·m
Unit
N·m

In testing for 2024 to 2026.

Front axle, actual torque BMW_FRONT_AXLE_ACT_TQ

  • Service 22DID DB32
  • Module6F1 → 619
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8192 to 8191 N·m
Unit
N·m

In testing for 2024 to 2026.

Highest cell voltage BMW_HVBAT_CELL_V_MAX

  • Service 22DID DDBF
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2024 to 2026.

Ignition angle BMW_IGN_ANGLE

  • Service 22DID 59FA
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2024 to 2026.

Ignition timing, cylinder 1 BMW_IGN_TIMING_1

  • Service 22DID 4A49
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2024 to 2026.

Ignition timing, cylinder 2 BMW_IGN_TIMING_2

  • Service 22DID 4A4A
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2024 to 2026.

Ignition timing, cylinder 3 BMW_IGN_TIMING_3

  • Service 22DID 4A4C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2024 to 2026.

Ignition timing, cylinder 4 BMW_IGN_TIMING_4

  • Service 22DID 4A4D
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2024 to 2026.

Intake air temperature BMW_IAT

  • Service 22DID 4015
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 150 °C
Unit
°C

In testing for 2024 to 2026.

Intake air temperature BMW_IAT_DME

  • Service 22DID 580F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2024 to 2026.

Intake manifold pressure BMW_MAP

  • Service 22DID 4A2D
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2024 to 2026.

Kickdown BMW_KICKDOWN

  • Service 22DID DA1F
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2024 to 2026.

Lambda BMW_LAMBDA_6F1_V2

  • Service 22DID 5889
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2024 to 2026.

Lambda 1, excess air ratio BMW_LAMBDA

  • Service 22DID 400B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val100
Range
0 to 2
Unit
Number

In testing for 2024 to 2026.

Lambda 1, excess air ratio BMW_LAMBDA_6F1

Pelican can show this parameter as the O2 lambda.

  • Service 22DID 400B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val100
Range
0 to 2
Unit
Number

In testing for 2024 to 2026.

Lambda 2 BMW_LAMBDA_2

  • Service 22DID 582C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2024 to 2026.

Lowest cell voltage BMW_HVBAT_CELL_V_MIN

  • Service 22DID DDBF
  • Module6F1 → 607
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 V
Unit
V

In testing for 2024 to 2026.

Misfire count, cylinder 1 BMW_MISFIRE_CNT_1

  • Service 22DID 4B23
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Misfire counter 2 BMW_MISFIRE_CNT_4B24

  • Service 22DID 4B24
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Misfire counter 3 BMW_MISFIRE_CNT_4B25

  • Service 22DID 4B25
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Misfire counter 4 BMW_MISFIRE_CNT_4B30

  • Service 22DID 4B30
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Misfire counter 5 BMW_MISFIRE_CNT_4B31

  • Service 22DID 4B31
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Misfire counter 6 BMW_MISFIRE_CNT_4B32

  • Service 22DID 4B32
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Oil level BMW_OIL_LEVEL

  • Service 22DID 442C
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

On-board charger board temperature BMW_OBC_T_BOARD

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Outside temperature, climate control BMW_IHX_AAT

  • Service 22DID D96B
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2−40
Range
-16424 to 16343 °C
Unit
°C

In testing for 2024 to 2026.

Ready to charge BMW_CHG_READY_V2

  • Service 22DID DEF6
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Recirculation BMW_HVAC_RECIRC

  • Service 22DID D931
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Rev limiter BMW_REV_LIMIT

  • Service 22DID 4A2E
  • Module6F1 → 612
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2024 to 2026.

Sixth word, raw BMW_D030_RAW_6

Reads about half the knots word on 2016 and 2017; reads 21 to 6411 on 2012 with every wheel speed 0

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Speed from satellite positioning BMW_GPS_SPD

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2024 to 2026.

Steering torque BMW_STEER_TQ

  • Service 22DID DB99
  • Module6F1 → 630
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 N·m
Unit
N·m

In testing for 2024 to 2026.

Time in d BMW_TIME_D

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Time in m BMW_TIME_M

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Time in s BMW_TIME_S

  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Trip average consumption since reset BMW_RBC_AVG_CONS

  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh/100 km
Unit
kWh/100 km

In testing for 2024 to 2026.

Trip average speed since reset BMW_RBC_AVG_SPD

  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2024 to 2026.

Trip computer average consumption BMW_BC_AVG_CONS

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh/100 km
Unit
kWh/100 km

In testing for 2024 to 2026.

Trip computer average speed BMW_BC_AVG_SPD

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2024 to 2026.

Trip computer range BMW_BC_RANGE

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2024 to 2026.

Trip distance since reset BMW_RBC_DIST

  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2024 to 2026.

Variable geometry turbocharger calibration angle BMW_VGT_CAL_ANGLE

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×156.2510000
Range
0 to 1000 °
Unit
°

In testing for 2024 to 2026.

Wheel sensor speed 1 BMW_NBT_WHL_SPD_1

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2024 to 2026.

Wheel sensor speed 2 BMW_NBT_WHL_SPD_2

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2024 to 2026.

Wheel sensor speed 3 BMW_NBT_WHL_SPD_3

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2024 to 2026.

Wheel sensor speed 4 BMW_NBT_WHL_SPD_4

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2024 to 2026.

Yaw rate BMW_YAW_RATE

  • Service 21PID 04
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×0.4100
Range
-131.072 to 131.068 m/s²
Unit
m/s²

In testing for 2024 to 2026.

Fluids

Distance since last oil change BMW_OIL_CHANGE_DIST

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every30 s
  • Testing

Bits 304 to 335 of the reply, 32 bits.

Formula
val
Range
0 to 1000000 km
Unit
km

In testing for 2024 to 2026.

Fuel

Ethanol content, CAN broadcast, live BMW_ETHANOL_CAN

  • Service 22DID 40CB
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Fuel pressure BMW_FUEL_PRES

  • Service 22DID 5AC3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2.6
Range
0 to 170391 bar
Unit
bar

In testing for 2024 to 2026.

Fuel rail pressure BMW_FRP

  • Service 22DID 56D7
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 bar
Unit
bar

In testing for 2024 to 2026.

Low side fuel pressure BMW_LOW_SIDE_FUEL_P

  • Service 22DID 58F3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2024 to 2026.

Movement

AT turbine speed BMW_TURBINE_SPD

  • Service 21PID 05
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2024 to 2026.

Engine oil pressure BMW_EOP

  • Service 22DID 586F
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2024 to 2026.

Front left wheel speed BMW_FL_SPD

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

In testing for 2024 to 2026.

Front right wheel speed BMW_FR_SPD

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

In testing for 2024 to 2026.

Lateral acceleration BMW_LATERAL_ACCELERATION

  • Service 21PID 04
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val×0.4100
Range
-131.072 to 131.068 m/s²
Unit
m/s²

In testing for 2024 to 2026.

Longitudinal acceleration BMW_LONGITUDINAL_ACCELERATION

  • Service 21PID 04
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×0.4100
Range
-131.072 to 131.068 m/s²
Unit
m/s²

In testing for 2024 to 2026.

Rear left wheel speed BMW_RL_SPD

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

In testing for 2024 to 2026.

Rear right wheel speed BMW_RR_SPD

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

In testing for 2024 to 2026.

Vehicle speed BMW_VSS

Speedometer vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID D107
  • Module6F1 → 660
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Vehicle speed BMW_VSS_V2

Speedometer vehicle speed

Pelican can show this parameter as the speed.

  • Service 22DID D107
  • Module6F1 → 663
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Vehicle speed BMW_VSS2

High resolution vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID 4AB1
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Vehicle speed, instrument cluster BMW_VSS_INSTR

Instrument cluster vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID D240
  • Module6F1 → 60D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1000 km/h
Unit
km/h

In testing for 2024 to 2026.

Tires

Average wheel speed BMW_AVG_WHEELS_SPD

  • Service 21PID 07
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2
Range
0 to 510 km/h
Unit
km/h

In testing for 2024 to 2026.

Front axle, actual torque BMW_AXLE_FRONT_ACTUAL_TORQUE

  • Service 22DID DB32
  • Module6F1 → 619
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8000 to 8000 N·m
Unit
N·m

In testing for 2024 to 2026.

Front axle, set point torque BMW_AXLE_FRONT_SETPOINT_TORQUE

  • Service 22DID DB32
  • Module6F1 → 619
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val4
Range
-8000 to 8000 N·m
Unit
N·m

In testing for 2024 to 2026.

Front left tire pressure BMW_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2024 to 2026.

Front left tire pressure BMW_TP_FL_F30

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Front left tire pressure, set point BMW_TP_SET_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Front left tire sensor battery life, months BMW_TPMS_BAT_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Front left tire sensor position BMW_TPMS_POS_FL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Front left tire temperature BMW_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Front left tire temperature BMW_TT_FL_F30

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Front left wheel speed, service 21 BMW_FL_VSS_21

  • Service 21PID 01
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Front right tire pressure BMW_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2024 to 2026.

Front right tire pressure BMW_TP_FR_F30

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Front right tire pressure, set point BMW_TP_SET_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Front right tire sensor battery life, months BMW_TPMS_BAT_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Front right tire sensor position BMW_TPMS_POS_FR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Front right tire temperature BMW_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Front right tire temperature BMW_TT_FR_F30

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Front right wheel speed, service 21 BMW_FR_VSS_21

  • Service 21PID 01
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Rear left tire pressure BMW_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2024 to 2026.

Rear left tire pressure BMW_TP_RL_F30

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Rear left tire pressure, set point BMW_TP_SET_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Rear left tire sensor battery life, months BMW_TPMS_BAT_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Rear left tire sensor position BMW_TPMS_POS_RL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Rear left tire temperature BMW_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Rear left tire temperature BMW_TT_RL_F30

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Rear left wheel speed, service 21 BMW_RL_VSS_21

  • Service 21PID 01
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Rear right tire pressure BMW_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2024 to 2026.

Rear right tire pressure BMW_TP_RR_F30

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Rear right tire pressure, set point BMW_TP_SET_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Rear right tire sensor battery life, months BMW_TPMS_BAT_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Rear right tire sensor position BMW_TPMS_POS_RR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Rear right tire temperature BMW_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Rear right tire temperature BMW_TT_RR_F30

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

Rear right wheel speed, service 21 BMW_RR_VSS_21

  • Service 21PID 01
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Steering wheel angle BMW_STEERING_WHEEL_ANGLE

  • Service 21PID 04
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×12.5100
Range
-4096 to 4095.875 °
Unit
°

In testing for 2024 to 2026.

Tire sensor reception code, raw, front left BMW_TPMS_RX_FL_F48

0 while the sensor reports; 146-159 on replies with no pressure or temperature. Not a percentage.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Tire sensor reception code, raw, front right BMW_TPMS_RX_FR_F48

0 while the sensor reports; 146-159 on replies with no pressure or temperature. Not a percentage.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Tire sensor reception code, raw, rear left BMW_TPMS_RX_RL_F48

0 while the sensor reports; 146-159 on replies with no pressure or temperature. Not a percentage.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Tire sensor reception code, raw, rear right BMW_TPMS_RX_RR_F48

0 while the sensor reports; 146-159 on replies with no pressure or temperature. Not a percentage.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Tire sensor reception, front left BMW_TPMS_RX_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Tire sensor reception, front right BMW_TPMS_RX_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Tire sensor reception, rear left BMW_TPMS_RX_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Tire sensor reception, rear right BMW_TPMS_RX_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Transmission

Clutch lock-up speed BMW_CLU_LOCK_UP

  • Service 21PID 0B
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2024 to 2026.

Current gear BMW_GEAR_V2

  • Service 22DID D031
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

DC/DC converter board temperature BMW_DCDC_T_BOARD

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Drive mode BMW_GEAR

  • Service 22DID DA2E
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
3DRIVEDrive
5SPORTSport

In testing for 2024 to 2026.

Shift gear BMW_GEAR_SHIFT

  • Service 22DID DA2E
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0PARKPark
1REVERSEReverse
2NEUTRALNeutral
3DRIVEDrive

In testing for 2024 to 2026.

Torque converter lockup BMW_TQ_CNVRT_LOCKUP

  • Service 22DID DA22
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OPENOpen
1CONTROL_LOWControlled low
2CONTROL_HIGHControlled high
3CLOSED_LOWClosed low
4CLOSED_HIGHClosed high
8TRANSITION_OPENTransition to open

In testing for 2024 to 2026.

Torque converter speed BMW_TQ_CNVRT_RPM

  • Service 22DID DA2A
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2024 to 2026.

Transmission output shaft speed BMW_TRANS_SHAFT_RPM

  • Service 22DID DA2A
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2024 to 2026.

Trips

Auxiliary power consumption BMW_AUX_PWR

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 kW
Unit
kW

In testing for 2024 to 2026.

Current electric range BMW_RANGE_E_CUR

Current estimated electric range

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2024 to 2026.

Current fuel range BMW_RANGE_F_CUR

Requires range extender.

Pelican can show this parameter as the fuel range.

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2024 to 2026.

Distance since last oil change BMW_DIST_SINCE_OIL

  • Service 22DID DFE7
  • Module6F1 → 619
  • Every30 s
  • Testing

Bits 304 to 335 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2024 to 2026.

Electric consumption / 100km BMW_RANGE_E_USE

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 kWh
Unit
kWh

In testing for 2024 to 2026.

Engine operating hours BMW_ENG_HOURS

  • Service 22DID 558F
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2
Range
0 to 2147483647 h
Unit
h

In testing for 2024 to 2026.

Estimated range remaining BMW_RANGE

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2024 to 2026.

Estimated range remaining in comfort mode BMW_RANGE_COMF

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2024 to 2026.

Estimated range remaining in economy mode BMW_RANGE_ECO

Pelican can show this parameter as the electric range.

  • Service 22DID 420C
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2024 to 2026.

Maximum electric range BMW_RANGE_E_MAX

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2024 to 2026.

Maximum fuel range BMW_RANGE_F_MAX

Requires range extender.

  • Service 22DID D111
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 km
Unit
km

In testing for 2024 to 2026.

Odometer BMW_ODO

  • Service 22DID DA23
  • Module6F1 → 618
  • Every15 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×8
Range
0 to 1000000 km
Unit
km

In testing for 2024 to 2026.

Odometer BMW_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2024 to 2026.

Odometer variant BMW_ODO_2

Pelican can show this parameter as the odometer.

  • Service 22DID 1700
  • Module6F1 → 640
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000000 km
Unit
km

In testing for 2024 to 2026.

Odometer, alternative BMW_ODO_ALT

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2024 to 2026.

Odometer, engine computer BMW_ODO_DME

  • Service 22DID 558E
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2024 to 2026.

Odometer, low resolution BMW_ODO_LOWRES

Pelican can show this parameter as the odometer.

  • Service 22DID DA23
  • Module6F1 → 618
  • Every15 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val×8
Range
0 to 1000000 km
Unit
km

In testing for 2024 to 2026.

Windows

Rear window open BMW_REAR_WINDOW

  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.