Parameters
The BMW 6 Series Gran Coupe has 162 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery capacity SERIES6GC_BAT_CAP
- Service 22
DID 40A9 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2012 to 2018.
Battery state of charge current SERIES6GC_BAT_ST_CHG_CURRENT
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery state of charge last-1 SERIES6GC_BAT_ST_CHG_LAST_1
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery state of charge last-2 SERIES6GC_BAT_ST_CHG_LAST_2
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery state of charge last-3 SERIES6GC_BAT_ST_CHG_LAST_3
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery state of charge last-4 SERIES6GC_BAT_ST_CHG_LAST_4
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery state of charge last-5 SERIES6GC_BAT_ST_CHG_LAST_5
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in invalid state of charge SERIES6GC_BAT_TIME_INVALID_ST
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 0-40% SERIES6GC_BAT_TIME_ST_CHG_0_40
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 40-60% SERIES6GC_BAT_TIME_ST_CHG_40_60
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 60-70% SERIES6GC_BAT_TIME_ST_CHG_60_70
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 70-80% SERIES6GC_BAT_TIME_ST_CHG_70_80
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 80-90% SERIES6GC_BAT_TIME_ST_CHG_80_90
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery time in state of charge 90-100% SERIES6GC_BAT_TIME_ST_CHG_90_100
- Service 22
DID 40AD - Module
6F1 → 612 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 %
- Unit
- %
In testing for 2012 to 2018.
Battery voltage SERIES6GC_BAT_V
- Service 22
DID E54D - Module
6F1 → 607 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 V
- Unit
- V
In testing for 2012 to 2018.
Charge port light state SERIES6GC_CHG_LED
- Service 22
DID DEF3 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Charging interface ready SERIES6GC_CHG_READY
- Service 22
DID DEF2 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2012 to 2018.
DC charge contactor state SERIES6GC_DC_CONTACTOR
- Service 22
DID DEF8 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
DC charge control 1 SERIES6GC_DC_CTRL_1
- Service 22
DID DEF7 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
DC charge control 2 SERIES6GC_DC_CTRL_2
- Service 22
DID DEF7 - Module
6F1 → 614 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
DC charge permission SERIES6GC_DC_PERMIT
- Service 22
DID DEF7 - Module
6F1 → 614 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2012 to 2018.
DC charge plug connected SERIES6GC_DC_PLUG
- Service 22
DID DEF7 - Module
6F1 → 614 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2012 to 2018.
High voltage battery current SERIES6GC_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Service 22
DID E561 - Module
6F1 → 607 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 A
- Unit
- A
In testing for 2012 to 2018.
Original battery capacity SERIES6GC_ORIGINAL_BAT_CAP
- Service 22
DID 40A9 - Module
6F1 → 612 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2012 to 2018.
Climate
A/C compressor operating state SERIES6GC_COMP_STATE
- Service 22
DID D8C5 - Module
6F1 → 678 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Ambient air temperature SERIES6GC_AATConfirmed
- Service 22
DID D112 - Module
6F1 → 660 - Every
5 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 87.5 °C
- Unit
- °C
0x92 = 146 → = 33 °C
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Front air distribution, left SERIES6GC_AIR_DIST_L
- Service 22
DID D91A - Module
6F1 → 678 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Front air distribution, right SERIES6GC_AIR_DIST_R
- Service 22
DID D91A - Module
6F1 → 678 - Every
10 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Control
Brake pressure SERIES6GC_BRAKE_P
- Service 22
DID DBE5 - Module
6F1 → 629 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 bar
- Unit
- bar
In testing for 2012 to 2018.
Brake switch SERIES6GC_BRAKE_SWITCHConfirmed
- Service 22
DID DA28 - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Parking brake applied SERIES6GC_PARK_BRAKE
- Service 22
DID D130 - Module
6F1 → 640 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
Doors
Charge flap closed SERIES6GC_CHG_FLAP_CLOSED
- Service 22
DID DEF1 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2012 to 2018.
Electrical
12V battery current SERIES6GC_12V_A
- Service 22
DID 402B - Module
6F1 → 612 - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -200 to 5042.8 A
- Unit
- A
In testing for 2012 to 2018.
12V battery temperature SERIES6GC_12V_T
- Service 22
DID 402B - Module
6F1 → 612 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2012 to 2018.
12V battery voltage SERIES6GC_12V_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 402B - Module
6F1 → 612 - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 6 to 22.3837 V
- Unit
- V
In testing for 2012 to 2018.
Engine
Accelerator pedal position SERIES6GC_APP
- Service 22
DID DE9C - Module
6F1 → 612 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 4095 %
- Unit
- %
In testing for 2012 to 2018.
Air conditioning compressor PWM SERIES6GC_AC_COMP_PWM
- Service 22
DID D906 - Module
6F1 → 640 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Air conditioning compressor status SERIES6GC_AC_COMP_STAT
- Service 22
DID D906 - Module
6F1 → 640 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
AT engine torque SERIES6GC_ENG_TQ
- Service 21
PID 08 - Module
6F1 → 618 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2012 to 2018.
Automatic air recirculation SERIES6GC_HVAC_AUC
- Service 22
DID D930 - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
Automatic transmission fluid temperature SERIES6GC_ATF_TEMPConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID DA12 - Module
6F1 → 618 - Every
30 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 65487 °C
- Unit
- °C
0x0068 = 104 → = 56 °C
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Barometric pressure SERIES6GC_BARO
- Service 22
DID 4201 - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255.99 kPa
- Unit
- kPa
In testing for 2012 to 2018.
Boost pressure SERIES6GC_BOOST_P
- Service 22
DID 4205 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.99 kPa
- Unit
- kPa
In testing for 2012 to 2018.
Boost pressure, set point SERIES6GC_BOOST_P_SET
- Service 22
DID 4AB0 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255.99 kPa
- Unit
- kPa
In testing for 2012 to 2018.
Cabin temperature SERIES6GC_CABIN_T
- Service 22
DID D85C - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2012 to 2018.
Catalyst temperature SERIES6GC_CAT_T
- Service 22
DID 582F - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 6280 °C
- Unit
- °C
In testing for 2012 to 2018.
Charge cycle efficiency SERIES6GC_OBC_EFF_CYCLE
- Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Charger 12V supply voltage SERIES6GC_OBC_KL30_V
- Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2018.
Charger AC current, phase 1 SERIES6GC_OBC_AC_I_1
- Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2012 to 2018.
Charger AC current, phase 2 SERIES6GC_OBC_AC_I_2
- Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2012 to 2018.
Charger AC current, phase 3 SERIES6GC_OBC_AC_I_3
- Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 A
- Unit
- A
In testing for 2012 to 2018.
Charger AC voltage, phase 1 SERIES6GC_OBC_AC_V_1
- Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2012 to 2018.
Charger AC voltage, phase 2 SERIES6GC_OBC_AC_V_2
- Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2012 to 2018.
Charger AC voltage, phase 3 SERIES6GC_OBC_AC_V_3
- Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 V
- Unit
- V
In testing for 2012 to 2018.
Charger DC efficiency SERIES6GC_OBC_EFF_DC
- Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Charger grid frequency, phase 1 SERIES6GC_OBC_GRID_HZ
- Service 22
DID DE84 - Module
6F1 → 615 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 63.75 Hz
- Unit
- Hz
In testing for 2012 to 2018.
Charger HV DC current SERIES6GC_OBC_HV_I
- Service 22
DID DE87 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -204 to 6348 A
- Unit
- A
In testing for 2012 to 2018.
Charger HV DC voltage SERIES6GC_OBC_HV_V
- Service 22
DID DE86 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2018.
Charger HV output power SERIES6GC_OBC_PWR
- Service 22
DID DE85 - Module
6F1 → 615 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 W
- Unit
- W
In testing for 2012 to 2018.
Charger power reduction SERIES6GC_OBC_DERATING
- Service 22
DID DE84 - Module
6F1 → 615 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Charging cable current rating SERIES6GC_CHG_CABLE_I
- Service 22
DID DEF5 - Module
6F1 → 614 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2018.
Charging plug state SERIES6GC_CHG_PLUG_ST
- Service 22
DID DEF5 - Module
6F1 → 614 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Climate control off SERIES6GC_HVAC_OFF
- Service 22
DID D92C - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
Consumption, kwh/100km SERIES6GC_CONS_KWH_100KM
- Service 22
DID D12A - Module
6F1 → 660 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2012 to 2018.
Crank torque SERIES6GC_CRANK_TQ
- Service 22
DID 58BA - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2012 to 2018.
DC charging pin cover open SERIES6GC_DC_PIN_COVER
- Service 22
DID DEFA - Module
6F1 → 614 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
Drive electronics processor 0 temperature SERIES6GC_EME_T_MC0
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive electronics processor 2 temperature SERIES6GC_EME_T_MC2
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive inverter gate driver temperature SERIES6GC_INV_T_GATE
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive inverter HV DC current SERIES6GC_EM_INV_I_DC
- Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2012 to 2018.
Drive inverter phase u temperature SERIES6GC_INV_T_U
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive inverter phase v temperature SERIES6GC_INV_T_V
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive inverter phase w temperature SERIES6GC_INV_T_W
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive motor excitation current SERIES6GC_EM_I_EXC
- Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2012 to 2018.
Drive motor phase u current SERIES6GC_EM_I_U
- Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2012 to 2018.
Drive motor phase v current SERIES6GC_EM_I_V
- Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2012 to 2018.
Drive motor phase w current SERIES6GC_EM_I_W
- Service 22
DID DE8A - Module
6F1 → 61A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047 A
- Unit
- A
In testing for 2012 to 2018.
Drive motor speed SERIES6GC_EM_RPM
- Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -5000 to 27767 rpm
- Unit
- rpm
In testing for 2012 to 2018.
Drive motor temperature 1 SERIES6GC_EM_T_1
- Service 22
DID DEA6 - Module
6F1 → 61A - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive motor temperature 2 SERIES6GC_EM_T_2
- Service 22
DID DEA6 - Module
6F1 → 61A - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive motor torque, actual SERIES6GC_EM_TQ
- Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 N·m
- Unit
- N·m
In testing for 2012 to 2018.
Drive motor torque, requested SERIES6GC_EM_TQ_TGT
- Service 22
DID DEA7 - Module
6F1 → 61A - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 N·m
- Unit
- N·m
In testing for 2012 to 2018.
Engine load SERIES6GC_LOAD
Pelican can show this parameter as the engine load.
- Service 22
DID 5813 - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 191.25 %
- Unit
- %
In testing for 2012 to 2018.
Engine load 2 SERIES6GC_LOAD_2
- Service 22
DID 4A4B - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2018.
Engine load, target SERIES6GC_LOAD_TGT
- Service 22
DID 480C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1535 %
- Unit
- %
In testing for 2012 to 2018.
Engine oil temperature SERIES6GC_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID DA25 - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 65487 °C
- Unit
- °C
0x008F = 143 → = 95 °C
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Engine oil temperature SERIES6GC_EOT_DME
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 4408 - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2012 to 2018.
Engine torque SERIES6GC_ENG_TQ_6F1
- Service 22
DID 442F - Module
6F1 → 618 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2012 to 2018.
Ignition angle SERIES6GC_IGN_ANGLE
- Service 22
DID 59FA - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2012 to 2018.
Ignition timing, cylinder 1 SERIES6GC_IGN_TIMING_1
- Service 22
DID 4A49 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2012 to 2018.
Ignition timing, cylinder 2 SERIES6GC_IGN_TIMING_2
- Service 22
DID 4A4A - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2012 to 2018.
Ignition timing, cylinder 3 SERIES6GC_IGN_TIMING_3
- Service 22
DID 4A4C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2012 to 2018.
Ignition timing, cylinder 4 SERIES6GC_IGN_TIMING_4
- Service 22
DID 4A4D - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2012 to 2018.
Intake air temperature SERIES6GC_IAT_DME
- Service 22
DID 580F - Module
6F1 → 612 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2012 to 2018.
Intake manifold pressure SERIES6GC_MAP
- Service 22
DID 4A2D - Module
6F1 → 612 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 511.99 kPa
- Unit
- kPa
In testing for 2012 to 2018.
Kickdown SERIES6GC_KICKDOWNConfirmed
- Service 22
DID DA1F - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Lambda SERIES6GC_LAMBDA_6F1
- Service 22
DID 5889 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16
- Unit
- Number
In testing for 2012 to 2018.
Lambda 2 SERIES6GC_LAMBDA_2
- Service 22
DID 582C - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 15.99
- Unit
- Number
In testing for 2012 to 2018.
Oil level SERIES6GC_OIL_LEVEL
- Service 22
DID 442C - Module
6F1 → 612 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
On-board charger board temperature SERIES6GC_OBC_T_BOARD
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Outside temperature, climate control SERIES6GC_IHX_AAT
- Service 22
DID D96B - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16424 to 16343 °C
- Unit
- °C
In testing for 2012 to 2018.
Recirculation SERIES6GC_HVAC_RECIRC
- Service 22
DID D931 - Module
6F1 → 678 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2012 to 2018.
Rev limiter SERIES6GC_REV_LIMIT
- Service 22
DID 4A2E - Module
6F1 → 612 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2012 to 2018.
Speed from satellite positioning SERIES6GC_GPS_SPD
- Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Steering torque SERIES6GC_STEER_TQ
- Service 22
DID DB99 - Module
6F1 → 630 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255 N·m
- Unit
- N·m
In testing for 2012 to 2018.
Trip computer average consumption SERIES6GC_BC_AVG_CONS
- Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh/100 km
- Unit
- kWh/100 km
In testing for 2012 to 2018.
Trip computer average speed SERIES6GC_BC_AVG_SPD
- Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Trip computer range SERIES6GC_BC_RANGE
- Service 22
DID D129 - Module
6F1 → 660 - Every
30 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km
- Unit
- km
In testing for 2012 to 2018.
Wheel sensor speed 1 SERIES6GC_NBT_WHL_SPD_1
- Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Wheel sensor speed 2 SERIES6GC_NBT_WHL_SPD_2
- Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Wheel sensor speed 3 SERIES6GC_NBT_WHL_SPD_3
- Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Wheel sensor speed 4 SERIES6GC_NBT_WHL_SPD_4
- Service 22
DID D030 - Module
6F1 → 663 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Fuel
Fuel rail pressure SERIES6GC_FRP
- Service 22
DID 56D7 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310 bar
- Unit
- bar
In testing for 2012 to 2018.
Low side fuel pressure SERIES6GC_LOW_SIDE_FUEL_P
- Service 22
DID 58F3 - Module
6F1 → 612 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2012 to 2018.
Movement
AT turbine speed SERIES6GC_TURBINE_SPD
- Service 21
PID 05 - Module
6F1 → 618 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2012 to 2018.
Front left wheel speed SERIES6GC_FL_SPDConfirmed
- Service 22
DID DBE4 - Module
6F1 → 629 - Every
250 ms - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Front right wheel speed SERIES6GC_FR_SPDConfirmed
- Service 22
DID DBE4 - Module
6F1 → 629 - Every
250 ms - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Rear left wheel speed SERIES6GC_RL_SPDConfirmed
- Service 22
DID DBE4 - Module
6F1 → 629 - Every
250 ms - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Rear right wheel speed SERIES6GC_RR_SPDConfirmed
- Service 22
DID DBE4 - Module
6F1 → 629 - Every
250 ms - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Vehicle speed SERIES6GC_VSSConfirmed
Speedometer vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID D107 - Module
6F1 → 660 - Every
250 ms - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Tires
Average wheel speed SERIES6GC_AVG_WHEELS_SPD
- Service 21
PID 07 - Module
6F1 → 618 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Front left tire pressure SERIES6GC_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 6.3 bar
- Unit
- bar
In testing for 2012 to 2018.
Front left tire pressure, set point SERIES6GC_TP_SET_FL
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2012 to 2018.
Front left tire sensor battery life, months SERIES6GC_TPMS_BAT_FL
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2018.
Front left tire sensor position SERIES6GC_TPMS_POS_FL
0 front left, 1 front right, 2 rear left, 3 rear right
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Front left tire temperature SERIES6GC_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2012 to 2018.
Front right tire pressure SERIES6GC_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 6.3 bar
- Unit
- bar
In testing for 2012 to 2018.
Front right tire pressure, set point SERIES6GC_TP_SET_FR
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2012 to 2018.
Front right tire sensor battery life, months SERIES6GC_TPMS_BAT_FR
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2018.
Front right tire sensor position SERIES6GC_TPMS_POS_FR
0 front left, 1 front right, 2 rear left, 3 rear right
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Front right tire temperature SERIES6GC_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2012 to 2018.
Rear left tire pressure SERIES6GC_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 6.3 bar
- Unit
- bar
In testing for 2012 to 2018.
Rear left tire pressure, set point SERIES6GC_TP_SET_RL
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2012 to 2018.
Rear left tire sensor battery life, months SERIES6GC_TPMS_BAT_RL
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2018.
Rear left tire sensor position SERIES6GC_TPMS_POS_RL
0 front left, 1 front right, 2 rear left, 3 rear right
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Rear left tire temperature SERIES6GC_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2012 to 2018.
Rear right tire pressure SERIES6GC_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 6.3 bar
- Unit
- bar
In testing for 2012 to 2018.
Rear right tire pressure, set point SERIES6GC_TP_SET_RR
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2012 to 2018.
Rear right tire sensor battery life, months SERIES6GC_TPMS_BAT_RR
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2018.
Rear right tire sensor position SERIES6GC_TPMS_POS_RR
0 front left, 1 front right, 2 rear left, 3 rear right
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2018.
Rear right tire temperature SERIES6GC_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2012 to 2018.
Tire sensor reception, front left SERIES6GC_TPMS_RX_FL
- Service 22
DID DC98 - Module
6F1 → 629 - Every
15 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Tire sensor reception, front right SERIES6GC_TPMS_RX_FR
- Service 22
DID DC99 - Module
6F1 → 629 - Every
15 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Tire sensor reception, rear left SERIES6GC_TPMS_RX_RL
- Service 22
DID DC9A - Module
6F1 → 629 - Every
15 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Tire sensor reception, rear right SERIES6GC_TPMS_RX_RR
- Service 22
DID DC9B - Module
6F1 → 629 - Every
15 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2018.
Transmission
Clutch lock-up speed SERIES6GC_CLU_LOCK_UP
- Service 21
PID 0B - Module
6F1 → 618 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2012 to 2018.
Current gear SERIES6GC_GEAR_V2Confirmed
- Service 22
DID D031 - Module
6F1 → 663 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 254
- Unit
- Number
0x01 = 1 → 1
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
DC/DC converter board temperature SERIES6GC_DCDC_T_BOARD
- Service 22
DID DE8C - Module
6F1 → 61A - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2012 to 2018.
Drive mode SERIES6GC_GEARConfirmed
- Service 22
DID DA2E - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
0x05 = 5 → SPORT
| Raw value | State | Meaning |
|---|---|---|
3 | DRIVE | Drive |
5 | SPORT | Sport |
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Shift gear SERIES6GC_GEAR_SHIFTConfirmed
- Service 22
DID DA2E - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → PARK
| Raw value | State | Meaning |
|---|---|---|
0 | PARK | Park |
1 | REVERSE | Reverse |
2 | NEUTRAL | Neutral |
3 | DRIVE | Drive |
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Torque converter lockup SERIES6GC_TQ_CNVRT_LOCKUPConfirmed
- Service 22
DID DA22 - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
0x00 = 0 → OPEN
| Raw value | State | Meaning |
|---|---|---|
0 | OPEN | Open |
1 | CONTROL_LOW | Controlled low |
2 | CONTROL_HIGH | Controlled high |
3 | CLOSED_LOW | Closed low |
4 | CLOSED_HIGH | Closed high |
8 | TRANSITION_OPEN | Transition to open |
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Torque converter speed SERIES6GC_TQ_CNVRT_RPMConfirmed
- Service 22
DID DA2A - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x01F4 = 500 → 500 rpm
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Transmission output shaft speed SERIES6GC_TRANS_SHAFT_RPMConfirmed
- Service 22
DID DA2A - Module
6F1 → 618 - Every
1 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
0x0000 = 0 → 0 rpm
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Trips
Engine operating hours SERIES6GC_ENG_HOURS
- Service 22
DID 558F - Module
6F1 → 612 - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 2147483647 h
- Unit
- h
In testing for 2012 to 2018.
Odometer SERIES6GC_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID D10D - Module
6F1 → 660 - Every
5 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
0x0002F6C2 = 194242 → 194,242 km
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Odometer variant SERIES6GC_ODO_2
Pelican can show this parameter as the odometer.
- Service 22
DID 1700 - Module
6F1 → 640 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000000 km
- Unit
- km
In testing for 2012 to 2014, 2016 to 2018. Not supported for 2015.
Odometer, alternative SERIES6GC_ODO_ALTConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID D10D - Module
6F1 → 660 - Every
5 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
0x0002F6C2 = 194242 → 194,242 km
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Odometer, engine computer SERIES6GC_ODO_DME
Pelican can show this parameter as the odometer.
- Service 22
DID 558E - Module
6F1 → 612 - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2012 to 2018.
Odometer, low resolution SERIES6GC_ODO_LOWRESConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID DA23 - Module
6F1 → 618 - Every
15 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000000 km
- Unit
- km
0x00005ED7 = 24279 → = 194,232 km
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Time in drive SERIES6GC_TIME_DConfirmed
- Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Time in manual SERIES6GC_TIME_MConfirmed
- Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x64 = 100 → 100
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.
Time in sport SERIES6GC_TIME_SConfirmed
- Service 22
DID DA37 - Module
6F1 → 618 - Every
30 s - Testing for 2012 to 2014, 2016 to 2018
Example reply from a 2015 BMW 6 Series Gran Coupe.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xC9 = 201 → 201
Confirmed for 2015. In testing for 2012 to 2014, 2016 to 2018.