BMW 2 Series Plug-in Hybrid

Parameters

The BMW 2 Series Plug-in Hybrid has 218 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

HV battery charge S2PHEV_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Battery capacity S2PHEV_BAT_CAP

  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2016 to 2026.

Battery state of charge current S2PHEV_BAT_ST_CHG_CURRENT

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery state of charge last-1 S2PHEV_BAT_ST_CHG_LAST_1

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery state of charge last-2 S2PHEV_BAT_ST_CHG_LAST_2

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery state of charge last-3 S2PHEV_BAT_ST_CHG_LAST_3

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery state of charge last-4 S2PHEV_BAT_ST_CHG_LAST_4

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery state of charge last-5 S2PHEV_BAT_ST_CHG_LAST_5

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Battery time in invalid state of charge S2PHEV_BAT_TIME_INVALID_ST

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 0-40% S2PHEV_BAT_TIME_ST_CHG_0_40

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 40-60% S2PHEV_BAT_TIME_ST_CHG_40_60

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 60-70% S2PHEV_BAT_TIME_ST_CHG_60_70

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 70-80% S2PHEV_BAT_TIME_ST_CHG_70_80

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 80-90% S2PHEV_BAT_TIME_ST_CHG_80_90

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Battery time in state of charge 90-100% S2PHEV_BAT_TIME_ST_CHG_90_100

  • Service 22DID 40AD
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Charge port light state S2PHEV_CHG_LED

  • Service 22DID DEF3
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Charging interface ready S2PHEV_CHG_READY

  • Service 22DID DEF2
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2026.

DC charge contactor state S2PHEV_DC_CONTACTOR

  • Service 22DID DEF8
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

DC charge control 1 S2PHEV_DC_CTRL_1

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

DC charge control 2 S2PHEV_DC_CTRL_2

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

DC charge permission S2PHEV_DC_PERMIT

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2026.

DC charge plug connected S2PHEV_DC_PLUG

  • Service 22DID DEF7
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2026.

HV battery cell temperature, max S2PHEV_HVBAT_CT_MAXConfirmed

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

0x0B95 = 2965 → 2965100 = 29.65 °C

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery cell temperature, min S2PHEV_HVBAT_CT_MINConfirmed

  • Service 22DID DDC0
  • Module6F1 → 607
  • Every30 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.67 to 327.67 °C
Unit
°C

0x0B19 = 2841 → 2841100 = 28.41 °C

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery charge S2PHEV_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery charge S2PHEV_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Service 22DID E5CE
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

0x09BB = 2491 → 2491100 = 24.91 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery charge, max S2PHEV_HVBAT_SOC_MAXConfirmed

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery charge, min S2PHEV_HVBAT_SOC_MINConfirmed

  • Service 22DID DDBC
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 100 %
Unit
%

0x0000 = 0 → 010 = 0 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

HV battery health S2PHEV_HVBAT_SOH_V2Confirmed

Pelican can show this parameter as the state of health.

  • Service 22DID E5C7
  • Module6F1 → 607
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x32 = 50 → 50 %

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Original battery capacity S2PHEV_ORIGINAL_BAT_CAP

  • Service 22DID 40A9
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2016 to 2026.

Climate

A/C compressor operating state S2PHEV_COMP_STATE

  • Service 22DID D8C5
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Ambient air temperature AATSAE J1979Confirmed

  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024.

Ambient air temperature S2PHEV_AATConfirmed

  • Service 22DID D112
  • Module6F1 → 660
  • Every5 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 7 of the reply, 8 bits.

Formula
val2−40
Range
-40 to 87.5 °C
Unit
°C

0x71 = 113 → 1132−40 = 16.5 °C

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Front air distribution, left S2PHEV_AIR_DIST_L

  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Front air distribution, right S2PHEV_AIR_DIST_R

  • Service 22DID D91A
  • Module6F1 → 678
  • Every10 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Clocks

Time since engine start RUNTMSAE J1979Confirmed

Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.

  • Service 01PID 1F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2024.

Control

Brake pressure S2PHEV_BRAKE_P

  • Service 22DID DBE5
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 bar
Unit
bar

In testing for 2016 to 2026.

Parking brake applied S2PHEV_PARK_BRAKE

  • Service 22DID D130
  • Module6F1 → 640
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Doors

Charge flap closed S2PHEV_CHG_FLAP_CLOSED

  • Service 22DID DEF1
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2026.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024.

Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed

Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.

  • Service 01PID 21
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2024.

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2024.

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2024.

Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed

Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.

  • Service 01PID 30
  • Module7E0 → 7E8
  • Every60 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2024.

Status

A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Catalyst monitoring ready CAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 9 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

EGR system monitoring ready EGR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Misfire monitoring ready MIS_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

Confirmed for 2024.

Support

A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 19 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Catalyst monitoring supported CAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed

Indicates support of spark ignition or compression ignition monitors.

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 12 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0SPARKSpark ignition monitors supported
1COMPRESSIONCompression ignition monitors supported

Confirmed for 2024.

EGR system monitoring supported EGR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Misfire monitoring supported MIS_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 18 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed

  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Electrical

12V battery current S2PHEV_12V_A

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val12.5−200
Range
-200 to 5042.8 A
Unit
A

In testing for 2016 to 2026.

12V battery temperature S2PHEV_12V_T

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 2016 to 2026.

12V battery voltage S2PHEV_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Service 22DID 402B
  • Module6F1 → 612
  • Every10 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val4000+6
Range
6 to 22.3837 V
Unit
V

In testing for 2016 to 2026.

Engine

Accelerator pedal position S2PHEV_APP

  • Service 22DID DE9C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val16
Range
0 to 4095 %
Unit
%

In testing for 2016 to 2026.

Air conditioning compressor PWM S2PHEV_AC_COMP_PWM

  • Service 22DID D906
  • Module6F1 → 640
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Air conditioning compressor status S2PHEV_AC_COMP_STAT

  • Service 22DID D906
  • Module6F1 → 640
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

AT engine torque S2PHEV_ENG_TQ

  • Service 21PID 08
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2016 to 2026.

Automatic air recirculation S2PHEV_HVAC_AUC

  • Service 22DID D930
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Automatic transmission fluid temperature S2PHEV_ATF_T

  • Service 21PID 0A
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−55
Range
-55 to 200 °C
Unit
°C

In testing for 2016 to 2026.

Barometric pressure S2PHEV_BARO

  • Service 22DID 4201
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2016 to 2026.

Boost pressure S2PHEV_BOOST_P

  • Service 22DID 4205
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2016 to 2026.

Boost pressure, set point S2PHEV_BOOST_P_SET

  • Service 22DID 4AB0
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val256
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2016 to 2026.

Cabin temperature S2PHEV_CABIN_T

  • Service 22DID D85C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2026.

Catalyst temperature S2PHEV_CAT_T

  • Service 22DID 582F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10−273.15
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2016 to 2026.

Charge cycle efficiency S2PHEV_OBC_EFF_CYCLE

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Charger 12V supply voltage S2PHEV_OBC_KL30_V

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val10
Range
0 to 25.5 V
Unit
V

In testing for 2016 to 2026.

Charger AC current, phase 1 S2PHEV_OBC_AC_I_1

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2016 to 2026.

Charger AC current, phase 2 S2PHEV_OBC_AC_I_2

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2016 to 2026.

Charger AC current, phase 3 S2PHEV_OBC_AC_I_3

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2016 to 2026.

Charger AC voltage, phase 1 S2PHEV_OBC_AC_V_1

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2016 to 2026.

Charger AC voltage, phase 2 S2PHEV_OBC_AC_V_2

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2016 to 2026.

Charger AC voltage, phase 3 S2PHEV_OBC_AC_V_3

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2016 to 2026.

Charger DC efficiency S2PHEV_OBC_EFF_DC

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Charger grid frequency, phase 1 S2PHEV_OBC_GRID_HZ

  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val4
Range
0 to 63.75 Hz
Unit
Hz

In testing for 2016 to 2026.

Charger HV DC current S2PHEV_OBC_HV_I

  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10−204.7
Range
-204 to 6348 A
Unit
A

In testing for 2016 to 2026.

Charger HV DC voltage S2PHEV_OBC_HV_V

  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 V
Unit
V

In testing for 2016 to 2026.

Charger HV output power S2PHEV_OBC_PWR

  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2016 to 2026.

Charger power reduction S2PHEV_OBC_DERATING

  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Charging cable current rating S2PHEV_CHG_CABLE_I

  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2016 to 2026.

Charging plug state S2PHEV_CHG_PLUG_ST

  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Climate control off S2PHEV_HVAC_OFF

  • Service 22DID D92C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Consumption, kwh/100km S2PHEV_CONS_KWH_100KM

  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553
Unit
Number

In testing for 2016 to 2026.

Coolant temperature S2PHEV_COOLANT

  • Service 22DID 411E
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 200 °C
Unit
°C

In testing for 2016 to 2026.

Crank torque S2PHEV_CRANK_TQ

  • Service 22DID 58BA
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 N·m
Unit
N·m

In testing for 2016 to 2026.

DC charging pin cover open S2PHEV_DC_PIN_COVER

  • Service 22DID DEFA
  • Module6F1 → 614
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Drive electronics processor 0 temperature S2PHEV_EME_T_MC0

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive electronics processor 2 temperature S2PHEV_EME_T_MC2

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive inverter gate driver temperature S2PHEV_INV_T_GATE

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive inverter HV DC current S2PHEV_EM_INV_I_DC

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 A
Unit
A

In testing for 2016 to 2026.

Drive inverter phase u temperature S2PHEV_INV_T_U

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive inverter phase v temperature S2PHEV_INV_T_V

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive inverter phase w temperature S2PHEV_INV_T_W

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive motor excitation current S2PHEV_EM_I_EXC

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2016 to 2026.

Drive motor phase u current S2PHEV_EM_I_U

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2016 to 2026.

Drive motor phase v current S2PHEV_EM_I_V

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2016 to 2026.

Drive motor phase w current S2PHEV_EM_I_W

  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047 A
Unit
A

In testing for 2016 to 2026.

Drive motor speed S2PHEV_EM_RPM

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2−5000
Range
-5000 to 27767 rpm
Unit
rpm

In testing for 2016 to 2026.

Drive motor temperature 1 S2PHEV_EM_T_1

  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive motor temperature 2 S2PHEV_EM_T_2

  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive motor torque, actual S2PHEV_EM_TQ

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2016 to 2026.

Drive motor torque, requested S2PHEV_EM_TQ_TGT

  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2016 to 2026.

Engine load S2PHEV_LOAD

  • Service 22DID 5813
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75
Range
0 to 191.25 %
Unit
%

In testing for 2016 to 2026.

Engine load 2 S2PHEV_LOAD_2

  • Service 22DID 4A4B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Engine load, target S2PHEV_LOAD_TGT

  • Service 22DID 480C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×3128
Range
0 to 1535 %
Unit
%

In testing for 2016 to 2026.

Engine oil temperature S2PHEV_EOT_6F1

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4402
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 °C
Unit
°C

In testing for 2016 to 2026.

Engine oil temperature S2PHEV_EOT_DME

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 °C
Unit
°C

In testing for 2016 to 2026.

Engine oil temperature S2PHEV_OIL_TEMP

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 4506
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 200 °C
Unit
°C

In testing for 2016 to 2026.

Engine oil temperature, alternate S2PHEV_OIL_TEMP_ALT

Pelican can show this parameter as the engine oil temperature.

  • Service 22DID 57C3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 200 °C
Unit
°C

In testing for 2016 to 2026.

Engine temperature S2PHEV_ET_8

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 4300
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×34−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2016 to 2026.

Engine torque S2PHEV_ENG_TQ_6F1

  • Service 22DID 442F
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2016 to 2026.

Exhaust gas calculated temperature S2PHEV_EGT_CALC

  • Service 22DID 4C5B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 1200 °C
Unit
°C

In testing for 2016 to 2026.

Ignition angle S2PHEV_IGN_ANGLE

  • Service 22DID 59FA
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val×0.75
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2026.

Ignition timing, cylinder 1 S2PHEV_IGN_TIMING_1

  • Service 22DID 4A49
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2016 to 2026.

Ignition timing, cylinder 2 S2PHEV_IGN_TIMING_2

  • Service 22DID 4A4A
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2016 to 2026.

Ignition timing, cylinder 3 S2PHEV_IGN_TIMING_3

  • Service 22DID 4A4C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2016 to 2026.

Ignition timing, cylinder 4 S2PHEV_IGN_TIMING_4

  • Service 22DID 4A4D
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 °
Unit
°

In testing for 2016 to 2026.

Intake air temperature S2PHEV_IAT

  • Service 22DID 4015
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 150 °C
Unit
°C

In testing for 2016 to 2026.

Intake air temperature S2PHEV_IAT_DME

  • Service 22DID 580F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val×0.75−48
Range
-48 to 143.25 °C
Unit
°C

In testing for 2016 to 2026.

Intake manifold pressure S2PHEV_MAP

  • Service 22DID 4A2D
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val128
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2016 to 2026.

Lambda S2PHEV_LAMBDA_6F1

  • Service 22DID 5889
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×1665535
Range
0 to 16
Unit
Number

In testing for 2016 to 2026.

Lambda 1, excess air ratio S2PHEV_LAMBDA

  • Service 22DID 400B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val100
Range
0 to 2
Unit
Number

In testing for 2016 to 2026.

Lambda 2 S2PHEV_LAMBDA_2

  • Service 22DID 582C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4096
Range
0 to 15.99
Unit
Number

In testing for 2016 to 2026.

Oil level S2PHEV_OIL_LEVEL

  • Service 22DID 442C
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

On-board charger board temperature S2PHEV_OBC_T_BOARD

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Outside temperature, climate control S2PHEV_IHX_AAT

  • Service 22DID D96B
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2−40
Range
-16424 to 16343 °C
Unit
°C

In testing for 2016 to 2026.

Recirculation S2PHEV_HVAC_RECIRC

  • Service 22DID D931
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Rev limiter S2PHEV_REV_LIMIT

  • Service 22DID 4A2E
  • Module6F1 → 612
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016 to 2026.

Speed from satellite positioning S2PHEV_GPS_SPD

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2016 to 2026.

Steering torque S2PHEV_STEER_TQ

  • Service 22DID DB99
  • Module6F1 → 630
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-256 to 255 N·m
Unit
N·m

In testing for 2016 to 2026.

Trip computer average consumption S2PHEV_BC_AVG_CONS

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh/100 km
Unit
kWh/100 km

In testing for 2016 to 2026.

Trip computer average speed S2PHEV_BC_AVG_SPD

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val100
Range
0 to 655 km/h
Unit
km/h

In testing for 2016 to 2026.

Trip computer range S2PHEV_BC_RANGE

  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 km
Unit
km

In testing for 2016 to 2026.

Wheel sensor speed 1 S2PHEV_NBT_WHL_SPD_1

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2016 to 2026.

Wheel sensor speed 2 S2PHEV_NBT_WHL_SPD_2

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2016 to 2026.

Wheel sensor speed 3 S2PHEV_NBT_WHL_SPD_3

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2016 to 2026.

Wheel sensor speed 4 S2PHEV_NBT_WHL_SPD_4

  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2016 to 2026.

Fuel

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val5
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2024.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val20
Range
0 to 3276.75 L/h
Unit
L/h

Confirmed for 2024.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Ethanol content, CAN broadcast, live S2PHEV_ETHANOL_CAN

  • Service 22DID 40CB
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val2
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Fuel pressure S2PHEV_FUEL_PRES

  • Service 22DID 5AC3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val×2.6
Range
0 to 170391 bar
Unit
bar

In testing for 2016 to 2026.

Fuel rail pressure S2PHEV_FRP

  • Service 22DID 56D7
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val50
Range
0 to 1310 bar
Unit
bar

In testing for 2016 to 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2024.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFNo status reported: this fuel system is not running or not present, e.g. the engine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
68OL-Drive B1+B2Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2024.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Low side fuel pressure S2PHEV_LOW_SIDE_FUEL_P

  • Service 22DID 58F3
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.53 bar
Unit
bar

In testing for 2016 to 2026.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val50
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2024.

Internal

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Movement

AT turbine speed S2PHEV_TURBINE_SPD

  • Service 21PID 05
  • Module6F1 → 618
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2016 to 2026.

Front left wheel speed S2PHEV_FL_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Front right wheel speed S2PHEV_FR_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Rear left wheel speed S2PHEV_RL_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Rear right wheel speed S2PHEV_RR_SPDConfirmed

  • Service 22DID DBE4
  • Module6F1 → 629
  • Every250 ms
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327.68 to 327.67 km/h
Unit
km/h

0x0000 = 0 → 0100 = 0 km/h

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Vehicle speed S2PHEV_VSSConfirmed

Speedometer vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID D107
  • Module6F1 → 660
  • Every250 ms
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

0x0000 = 0 → 010 = 0 km/h

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2024.

OBD

OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed

  • Service 01PID 1C
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1OBD IIOBD II (California ARB)
2OBDOBD (Federal EPA)
3OBD & OBD II
4OBD I
5NO OBDNot OBD compliant
6EOBD
7EOBD & OBD II
8EOBD & OBD
9EOBD, OBD, OBD II
10JOBD
11JOBD & OBD II
12JOBD & EOBD
13JOBD, EOBD, OBD II
14EURO IV B1Heavy duty vehicles (EURO IV) B1
15EURO V B2Heavy duty vehicles (EURO V) B2
16EURO CHeavy duty vehicles (EURO EEC) C (gas engines)
17EMDEngine manufacturer diagnostics (EMD)
18EMD+Engine Manufacturer Diagnostics Enhanced (EMD+)
19HD OBD-CHeavy Duty On-Board Diagnostics (Child/Partial)
20HD OBDHeavy Duty On-Board Diagnostics
21WWH OBDWorld Wide Harmonized OBD
23HD EOBD-IHeavy Duty Euro OBD Stage I without NOx Control
24HD EOBD-I NHeavy Duty Euro OBD Stage I with NOx Control
25HD EOBD-IIHeavy Duty Euro OBD Stage II without NOx Control
26HD EOBD-II NHeavy Duty Euro OBD Stage II with NOx Control
27HD-ZEVHeavy Duty ZEV
28OBDBr-1Brazil OBD Phase 1
29OBDBr-2Brazil OBD Phase 2 and Phase 2+
30KOBDKorean OBD
31IOBD-I-BS4India BS4 OBD I
32IOBD-II-BS4India BS4 OBD II
33HD EOBD-VIEuro VI
34OBD, OBD II and HD OBD
35OBDBr-3Brazil OBD Phase 3
36MC EOBD-IMotorcycle, Euro OBD-I
37MC EOBD-IIMotorcycle, Euro OBD-II
38MC COBD-IMotorcycle, China OBD-I
39MC TOBD-IMotorcycle, Taiwan OBD-I
40MC JOBD-IMotorcycle, Japan OBD-I
41CN-OBD-6China Nationwide Stage 6
42OBDBr-P7Brazil OBD Phase 7
43CN-HDOBD-VIChina Heavy Duty VI
44IOBD-I-BS6India BS6 OBD I
45IOBD-II-BS6India BS6 OBD II
46IHDOBD-BSVIIndia BSVI HD OBD
47OBDBr-P8Brazil OBD Phase 8
48HD-JOBD-IIJapan Heavy Duty OBD-II
49HD-KOBD-IIKorea Heavy Duty OBD-II
50CN-OROBD-IVChina Off-Road IV OBD
51CARB ACC-IILight Duty ZEV, ACC-II
52MC JOBD-IIMotorcycle, Japan OBD-II
53MC CARB OBDMotorcycle, California (CARB) OBD
54MC EPA OBDMotorcycle, Federal (EPA) OBD
55MC CARB & EPA OBDMotorcycle, 50-State (CARB & EPA) OBD
56HD ZEV CARB ZEPHeavy Duty ZEV, CARB ZEP
57CARB ACC-II & EPA TIER4Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22)
58EPA TIER4Light Duty ZEV, EPA Tier 4 (GTR 22)
59EPA HDEPA HD OBD

Confirmed for 2024.

Tires

Front left tire pressure S2PHEV_TP_FL

Pelican can show this parameter as the front left tire pressure.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2016 to 2026.

Front left tire pressure, set point S2PHEV_TP_SET_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2016 to 2026.

Front left tire sensor battery life, months S2PHEV_TPMS_BAT_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Front left tire sensor position S2PHEV_TPMS_POS_FL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Front left tire temperature S2PHEV_TT_FL

Pelican can show this parameter as the front left tire temperature.

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2026.

Front right tire pressure S2PHEV_TP_FR

Pelican can show this parameter as the front right tire pressure.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2016 to 2026.

Front right tire pressure, set point S2PHEV_TP_SET_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2016 to 2026.

Front right tire sensor battery life, months S2PHEV_TPMS_BAT_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Front right tire sensor position S2PHEV_TPMS_POS_FR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Front right tire temperature S2PHEV_TT_FR

Pelican can show this parameter as the front right tire temperature.

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2026.

Rear left tire pressure S2PHEV_TP_RL

Pelican can show this parameter as the rear left tire pressure.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2016 to 2026.

Rear left tire pressure, set point S2PHEV_TP_SET_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2016 to 2026.

Rear left tire sensor battery life, months S2PHEV_TPMS_BAT_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Rear left tire sensor position S2PHEV_TPMS_POS_RL

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Rear left tire temperature S2PHEV_TT_RL

Pelican can show this parameter as the rear left tire temperature.

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2026.

Rear right tire pressure S2PHEV_TP_RR

Pelican can show this parameter as the rear right tire pressure.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 6.3 bar
Unit
bar

In testing for 2016 to 2026.

Rear right tire pressure, set point S2PHEV_TP_SET_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val1000
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2016 to 2026.

Rear right tire sensor battery life, months S2PHEV_TPMS_BAT_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Rear right tire sensor position S2PHEV_TPMS_POS_RR

0 front left, 1 front right, 2 rear left, 3 rear right

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Rear right tire temperature S2PHEV_TT_RR

Pelican can show this parameter as the rear right tire temperature.

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2016 to 2026.

Tire sensor reception, front left S2PHEV_TPMS_RX_FL

  • Service 22DID DC98
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Tire sensor reception, front right S2PHEV_TPMS_RX_FR

  • Service 22DID DC99
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Tire sensor reception, rear left S2PHEV_TPMS_RX_RL

  • Service 22DID DC9A
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Tire sensor reception, rear right S2PHEV_TPMS_RX_RR

  • Service 22DID DC9B
  • Module6F1 → 629
  • Every15 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2016 to 2026.

Transmission

DC/DC converter board temperature S2PHEV_DCDC_T_BOARD

  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
val×392500
Range
-511 to 511 °C
Unit
°C

In testing for 2016 to 2026.

Drive mode S2PHEV_GEAR

  • Service 22DID DA2E
  • Module6F1 → 618
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
3DRIVEDrive
5SPORTSport

In testing for 2016 to 2023, 2025 to 2026. Supported for 2024.

Shift gear S2PHEV_GEAR_SHIFTConfirmed

  • Service 22DID DA2E
  • Module6F1 → 618
  • Every1 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states

0x00 = 0 → PARK

States
Raw valueStateMeaning
0PARKPark
1REVERSEReverse
2NEUTRALNeutral
3DRIVEDrive

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Trips

Engine operating hours S2PHEV_ENG_HOURS

  • Service 22DID 558F
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val2
Range
0 to 2147483647 h
Unit
h

In testing for 2016 to 2026.

Odometer S2PHEV_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00006D96 = 28054 → 28,054 km

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Odometer, alternative S2PHEV_ODO_ALTConfirmed

Pelican can show this parameter as the odometer.

  • Service 22DID D10D
  • Module6F1 → 660
  • Every5 s
  • Testing for 2016 to 2023, 2025 to 2026

Example reply from a 2024 BMW 2 Series Plug-in Hybrid.

Bits 32 to 63 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

0x00006D96 = 28054 → 28,054 km

Confirmed for 2024. In testing for 2016 to 2023, 2025 to 2026.

Odometer, engine computer S2PHEV_ODO_DME

  • Service 22DID 558E
  • Module6F1 → 612
  • Every60 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2016 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.