Parameters
The Audi TT has 956 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Accelerator pedal, sensor 1 voltage TT_ACCEL_PEDAL_SENS_1_V
- Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 1998 to 2023.
Accelerator pedal, sensor 2 voltage TT_ACCEL_PEDAL_SENS_2_V
- Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 1998 to 2023.
Aux. hydraulic pump voltage TT_AUX_HYDRAULIC_PMP_V
- Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1998 to 2023.
Battery voltage TT_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, raw voltage TT_BYPASS_VLV_HIGH_P_V
- Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge adjuster output stage TT_HIGH_P_TURBOCHARGER
- Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value TT_CHG_AIR_COOLER_INLET_P_1_1
- Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 1998 to 2023.
Charge air pressure TT_PQ35_CHG_AIR_P
- Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge air pressure actuator position digit.value TT_CHG_AIR_P_ACTUATOR_7E0
- Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Charge air pressure actuator, acknowledgment TT_CHG_AIR_P_ACTUATOR
- Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Charge air pressure, actual value TT_AIR_P_CAC_DS
- Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Charge air pressure, actual value TT_CHG_AIR_P_ACT
- Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 1998 to 2023.
Charge air pressure, specified value TT_CHG_AIR_P_SPEC
- Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Charge air pressure: actual TT_PQ35_CHARGE_AIR_P_ACTUAL
- Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 1998 to 2023.
Charge air pressure: specified TT_PQ35_CHARGE_AIR_P_SPECIFIED
- Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 1998 to 2023.
Charge pressure actuator, actual position TT_CHG_P_ACTUATOR_ACT
- Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure actuator, adaptation for lower stop TT_CHG_P_ACTUATOR_ADPT
- Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge pressure actuator, adaptation for upper stop TT_CHG_P_ACTUATOR_ADPT_HI
- Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge pressure actuator, maximum sensor voltage TT_CHG_P_ACTUATOR_MAX_V
- Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge pressure actuator, specified position TT_CHG_P_ACTUATOR_SPEC
- Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure actuator, specified value TT_CHG_P_ACTUATOR_SPEC_7E0
- Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure before throttle valve, calculated actual value TT_CHG_P_BEFORE_ACT
- Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 1998 to 2023.
Charge pressure control adaptation higher than max. threshold TT_CHG_P_CTRL_ADPT_MAX
- Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control adaptation lower than min. threshold TT_CHG_P_CTRL_ADPT_LO_MIN
- Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control specified value TT_CHG_P_CTRL_SPEC
- Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control valve activation pulse duty factor TT_CHG_P_CTRL_VLV
- Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control valve position, actual value TT_CHG_P_CTRL_VLV_POS_ACT
- Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control valve position, target value TT_CHG_P_CTRL_VLV_POS_TGT
- Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Charge pressure control valve sensor voltage TT_CHG_P_CTRL_VLV_SENS_V
- Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 1998 to 2023.
Charge pressure control valve voltage, position closed TT_CHG_P_CTRL_VLV_V_POS
- Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 1998 to 2023.
Charge pressure control valve voltage, position opened TT_CHG_P_CTRL_VLV_V_POS_OPENED
- Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 1998 to 2023.
Charge pressure regulator, lower threshold adaptation TT_CHG_P_REGULATOR_LO
- Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge pressure regulator, upper threshold adaptation TT_CHG_P_REGULATOR_HI
- Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 1998 to 2023.
Charge pressure sensor, unconditioned voltage TT_CHG_P_SENS_V
- Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Control module voltage TT_VPWR
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 1998 to 2023.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2011, 2013, 2017. Supported for 2010, 2015 to 2016.
Cylinder charge specified value TT_CYL_CHG_SPEC
- Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 1998 to 2023.
Cylinder charge, actual value TT_CYL_CHG_ACT
- Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 1998 to 2023.
DC to DC converter high-voltage side voltage TT_DCDC_HV_V
- Service 22
DID 1587 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 1998 to 2023.
High pressure exhaust gas recirculation actuator, actual unconditioned voltage TT_HIGH_P_EGR_ACTUATOR_ACT_V
- Service 22
DID 11A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 1998 to 2023.
HV battery maximum power TT_HVBAT_PWR_MAX
- Service 22
DID 1502 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262140 W
- Unit
- W
In testing for 1998 to 2023.
HV battery temperature load TT_HVBAT_T_LOAD
- Service 22
DID 1165 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Knock sensor voltage, cylinder 1 TT_KNOCK_SENS_V_CYL_1
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor voltage, cylinder 3 TT_KNOCK_SENS_V_CYL_3_7E0
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor voltage:, cylinder 2 TT_KNOCK_SENS_V_CYL_2
- Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor voltage:, cylinder 3 TT_KNOCK_SENS_V_CYL_3
- Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor voltage:, cylinder 5 TT_KNOCK_SENS_V_CYL_5
- Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor voltage:, cylinder 6 TT_KNOCK_SENS_V_CYL_6
- Service 22
DID 13FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensors average voltage bank 1, variant 2 TT_KNOCK_SENSORS_AVG_V_1_2
- Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Onboard electrical system power TT_AUX_PWR
- Service 22
DID 1077 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262140 W
- Unit
- W
In testing for 1998 to 2023.
Temperature sensor for engine temperature management voltage TT_T_SENS_ENG_T_V
- Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Turbocharger inlet pressure corrected value TT_TURBOCHARGER_INLET_P
- Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Climate
Ambient air temperature TT_AATConfirmed
- Service 22
DID 1014 - Module
714 → 77E - Every
5 s - Testing for 1998 to 2014, 2018 to 2023
Example reply from a 2017 Audi TT.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x8C = 140 → = 20 °C
Confirmed for 2015 to 2017. In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013.
Ambient air temperature TT_AAT_7E0_7E0
- Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Ambient temperature TT_AAT_V2
- Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255 to 255 °C
- Unit
- °C
In testing for 1998 to 2023.
Barometric pressure TT_BARO
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Clocks
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015 to 2016.
Time since engine start TT_RUNTM
How long it's been since the engine started.
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 1998 to 2023.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015 to 2016.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015.
Accelerator pedal release detection threshold voltage TT_APP_REDUCE_V
- Service 22
DID 1029 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 1998 to 2023.
Brake booster low pressure, actual TT_BRAKE_BOOSTER_LOW_P_ACT
- Service 22
DID 1490 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.9937
- Unit
- Raw value
In testing for 1998 to 2023.
Brake booster pressure TT_BRAKE_BOOSTER_P
- Service 22
DID 11CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559
- Unit
- Raw value
In testing for 1998 to 2023.
Brake booster pressure TT_PQ35_BRAKE_BOOSTER_P
- Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1998 to 2023.
Brake booster raw pressure TT_BRAKE_BOOSTER_RAW_P
- Service 22
DID 11D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1998 to 2023.
Brake pedal position TT_BRAKE_PEDAL_POS
- Service 22
DID 105D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Brake pressure TT_BRAKE_P_7E0
- Service 22
DID 195D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Brake system vacuum pump active TT_BRAKE_SYSTEM_VACUUM
- Service 22
DID 395E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Downshift point adaptation voltage TT_DOWNSHIFT_ADAPT_V
- Service 22
DID 1028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 1998 to 2023.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015 to 2016.
Requested brake torque, auxiliary system TT_REQ_BRAKE_TQ
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2015.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2015.
Accelerator pedal position sensor 1 TT_APP_POS1
- Service 22
DID 2061 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 1998 to 2023.
Accelerator pedal position sensor 2 TT_APP_POS2
- Service 22
DID 2062 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 1998 to 2023.
Drivetrain
Driver torque requested #1 TT_ENG_TRQ_REQ_1
- Service 22
DID 29D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Driver torque requested #2 TT_ENG_TRQ_REQ_2
- Service 22
DID 4380 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Distance traveled since diagnostic trouble codes cleared TT_CLR_DIST
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2023.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Distance traveled while mil was activated TT_MIL_DIST
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2023.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Number of warm-ups since diagnostic trouble codes cleared TT_WARM_UPS
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
ECU
Oil thermal wear TT_OIL_THERMAL_WEAR
- Service 22
DID 224B - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2023.
Engine
A/C compressor torque TT_A_C_COMPRESSOR_TORQUE
- Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
A/C refrigerant pressure TT_A_C_REFRIGERANT_PRES
- Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 1998 to 2023.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Adaptation of loss torque TT_ADPT_LOSS_TQ
- Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Adaptation of throttle valve TT_ADPT_THROTTLE_VLV
- Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder1 fast diagnosis TT_ADPT_VAL_CYL1_FAST
- Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder1 slow diagnosis TT_ADPT_VAL_CYL1_SLOW
- Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder2 fast diagnosis TT_ADPT_VAL_CYL2_FAST
- Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder2 slow diagnosis TT_ADPT_VAL_CYL2_SLOW
- Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder3 fast diagnosis TT_ADPT_VAL_CYL3_FAST
- Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder3 slow diagnosis TT_ADPT_VAL_CYL3_SLOW
- Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder4 fast diagnosis TT_ADPT_VAL_CYL4_FAST
- Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptation val.cylinder4 slow diagnosis TT_ADPT_VAL_CYL4_SLOW
- Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 1998 to 2023.
Adaptive mode TT_ADAPTIVE_MODE
- Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Air conditioning compressor pressure, linear raw value TT_AC_COMP_P_LINEAR_RAW
- Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 1998 to 2023.
Air conditioning compressor refrigerant pressure TT_AC_COMP_REFRIGERANT_P
- Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 1998 to 2023.
Air conditioning compressor torque TT_AC_COMP_TQ
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Air conditioning compressor torque TT_AC_COMP_TQ_REQ
- Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Air conditioning refrigerant pressure TT_AC_REFRIGERANT_P
- Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 1998 to 2023.
Air filling TT_AIR_FILLING
- Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2015. Supported for 2010.
Air leakage TT_AIR_LEAKAGE
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Air mass meter 1 TT_MQB_AIR_MASS_1
- Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 1998 to 2023.
Air mass, actual value, mg/stroke TT_AIR_MASS_ACT_MG
- Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1998 to 2023.
Air mass, specified value TT_AIR_MASS_SPEC
- Service 22
DID 104C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 1998 to 2023.
Ambient air pressure TT_AMBIENT_AIR_P
- Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 1998 to 2023.
Ambient temperature TT_AAT_7E0
- Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 1998 to 2023.
Ambient temperature TT_AAT_7E0_2
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Analysis, clutch 1, maximum temperature TT_ANALYSIS_CLU_1_MAX_T
- Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1998 to 2023.
Analysis, clutch 2, maximum temperature TT_ANALYSIS_CLU_2_MAX_T
- Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1998 to 2023.
Automatic engine starts counter TT_AUTOMATIC_ENG_STARTS
- Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Automatic transmission fluid temperature TT_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 2104 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1998 to 2023.
Aux. hydraulic pump internal temperature TT_AUX_HYDRAULIC_PMP_T
- Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Aux. hydraulic pump, current TT_AUX_HYDRAULIC_PMP
- Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 1998 to 2023.
Average ignition timing angle delay adjustment TT_AVG_IGN_TIM_ANG
- Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Avg. injection time TT_AVG_INJ_TIME
- Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1717986 ms
- Unit
- ms
In testing for 1998 to 2023.
Avg. injection time TT_AVG_INJ_TIME_7E0
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 ms
- Unit
- ms
In testing for 1998 to 2023.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Basic correction factor:, cylinder 1, filtered TT_BASIC_CORR_FACTOR_1
- Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 1998 to 2023.
Basic correction factor:, cylinder 2, filtered TT_BASIC_CORR_FACTOR_2
- Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 1998 to 2023.
Basic correction factor:, cylinder 3, filtered TT_BASIC_CORR_FACTOR_3
- Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 1998 to 2023.
Basic correction factor:, cylinder 4, filtered TT_BASIC_CORR_FACTOR_4
- Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 1998 to 2023.
Boost pressure actuator, commanded duty TT_BOOST_P_ACTUATOR_CMD
- Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.993 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017.
Boost pressure, actual TT_BOOST_P_ACT
- Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Boost pressure, actual TT_BOOST_P_ACT_7E0
- Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242
- Unit
- Raw value
In testing for 1998 to 2023.
Boost pressure, target TT_BOOST_P_TGT
- Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550
- Unit
- Raw value
In testing for 1998 to 2023.
Boost regulation duty, commanded value TT_BOOST_REGULATION_CMD
- Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Boost regulator feedback TT_BOOST_REGULATOR_FEEDBACK
- Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, activation TT_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, actual value TT_BYPASS_VLV_HIGH_P_ACT
- Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, offset closed TT_BYPASS_VLV_HIGH_P
- Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, offset open TT_BYPASS_VLV_HIGH_P_TURBINE
- Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Bypass valve high pressure turbine inlet, target value TT_BYPASS_VLV_HIGH_P_TGT
- Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2015, 2017. Supported for 2010 to 2011, 2016.
Calculated oil temperature TT_PQ35_CALCULATED_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Camshaft adaptation exhaust bank 1, phase position TT_CAM_ADPT_EXH_BANK_1_PHASE
- Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adaptation intake bank 1, phase position TT_CAM_ADPT_INT_BANK_1_PHASE
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adaptation intake, phase position TT_CAM_ADPT_INT_PHASE
- Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adaptation, counter due to knock TT_CAM_ADPT_CNT_KNOCK
- Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Camshaft adaptation, exhaust bank 1, phase position TT_CAM_ADPT_EXH_BANK_1
- Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adaptation, intake bank 1, phase position TT_CAM_ADPT_INT_BANK_1
- Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adaptation, intake deviation TT_CAM_ADPT_INT_DEV
- Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment intake bank 1, activation % TT_CAM_ADJ_INT_BANK_1
- Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Camshaft adjustment intake test bank 1 TT_CAM_ADJ_INT_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Camshaft adjustment outlet test bank 1 TT_CAM_ADJ_OUTLET_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Camshaft adjustment, exhaust bank 1, actual value TT_CAM_ADJ_EXH_BANK_1_ACT
- Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, exhaust bank 1, specified value TT_CAM_ADJ_EXH_BANK_1_SPEC
- Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, exhaust bank 2, actual value TT_CAM_ADJ_EXH_BANK_2_ACT
- Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, exhaust bank 2, specified value TT_CAM_ADJ_EXH_BANK_2_SPEC
- Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262 to 262 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, exhaust, actual value TT_CAM_ADJ_EXH_ACT
- Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, exhaust, specified value TT_CAM_ADJ_EXH_SPEC
- Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, intake bank 1, actual value TT_CAM_ADJ_INT_BANK_1_ACT
- Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, intake bank 1, specified value TT_CAM_ADJ_INT_BANK_1_SPEC
- Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, intake, actual value TT_CAM_ADJ_INT_ACT
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft adjustment, intake, specified value TT_CAM_ADJ_INT_SPEC
- Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Camshaft position, deviation from the base position TT_CAM_POS_DEV_BASE_POS
- Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 1998 to 2023.
Cat. converter oxygen storage capacity measured TT_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Cat. temperature, bank 1 TT_CAT_T_BANK_1
- Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 1998 to 2023.
Cat. temperature, bank 2 TT_CAT_T_BANK_2
- Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 1998 to 2023.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Catalyst temperature, calculated TT_CAT_T_CALC
- Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 1998 to 2023.
Centrifugal oil temperature TT_PQ35_CENTRIFUGAL_OIL_T
- Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 1998 to 2023.
Chain elongation inlet, mileage at last adaptation TT_CHAIN_ELONGATION_INLET
- Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1998 to 2023.
Chain elongation outlet, mileage at last adaptation TT_CHAIN_ELONGATION
- Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1998 to 2023.
Chain elongation, no of valid initial values, exhaust bank 1 TT_CHAIN_ELONGATION_NO_VALID_1
- Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Chain elongation, no of valid initial values, intake bank 1 TT_CHAIN_ELONGATION_NO_1
- Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Clutch center central plate temperature TT_CLU_CENTER_CENTRAL_T
- Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1998 to 2023.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2017.
Commanded crankshaft torque TT_CMD_CRANK_TQ
- Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015 to 2016.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017. Supported for 2015.
Compression test, cylinder 1 TT_COMPRESSION_TEST_CYL_1
- Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Compression test, cylinder 2 TT_COMPRESSION_TEST_CYL_2
- Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Compression test, cylinder 3 TT_COMPRESSION_TEST_CYL_3
- Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Compression test, cylinder 4 TT_COMPRESSION_TEST_CYL_4
- Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Control module temperature TT_CTRL_MODULE_T
- Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Control module temperature TT_MQB_TCM_ECU_T
- Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1998 to 2023.
Converter loss torque TT_MQB_TCM_CONVERTER_LOSS_TORQUE
- Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Coolant circulation pump, activation TT_CLT_CIRCULATION_PMP_ACTIVATION
- Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant circulation pump, control TT_CLT_CIRCULATION_PMP
- Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant fan 1 activation, $1117 TT_CLT_FAN_1_ACTIVATION_1117
- Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Coolant fan 1, activation TT_CLT_FAN_1_ACTIVATION
- Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant fan 1, activation TT_COOLANT_FAN_1_ACTIVATION
- Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant fan 2, activation TT_CLT_FAN_2_ACTIVATION
- Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant fan, requested by A/C TT_CLT_FAN_REQ_AC
- Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Coolant shut-off valve, closed TT_CLT_SHUT_OFF_VLV
- Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 1998 to 2023.
Coolant temperature at engine outlet, calculated TT_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at engine outlet, calculated TT_ECT_ENG_OUTLET_CALC
- Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at engine start TT_COOLANT_T_AT_ENGINE_START
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at engine start TT_ECT_ENG_START
- Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet TT_COOLANT_T
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet TT_ECT_RADIATOR_OUTLET
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet 2 TT_ECT_RAD_OUT_2
- Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet v.1 TT_ECT_RADIATOR_OUTLET_V_1
- Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet, actual value TT_ECT_RADIATOR_OUTLET_ACT
- Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet, actual value TT_ECT_RADIATOR_OUTLET_ACT_7E0
- Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature at radiator outlet, specified value TT_ECT_RADIATOR_OUTLET_SPEC
- Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature difference between engine and radiator TT_ECT_DIFF_ENG
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature linear TT_ECT_LINEAR
- Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature modeled value TT_COOLANT_T_MODELED_VALUE
- Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature, maximum value TT_ECT_MAX
- Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1998 to 2023.
Coolant temperature, minimum value TT_ECT_MIN
- Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1998 to 2023.
Correction factor of oil temperature for engine protection TT_CORR_FACTOR_OIL_T
- Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99
- Unit
- Number
In testing for 1998 to 2023.
Correction values for main pressure adaptation TT_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT
- Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Crankshaft rotation angle when closing the quantity control valve TT_CRANK_ROT_ANG
- Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
CTR_MIS_DC_MMV_CYL_SAE, 0 TT_CTR_MIS_DC_MMV_CYL_0
- Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
CTR_MIS_DC_MMV_CYL_SAE, 1 TT_CTR_MIS_DC_MMV_CYL_1
- Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
CTR_MIS_DC_MMV_CYL_SAE, 2 TT_CTR_MIS_DC_MMV_CYL_2
- Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Current N215 pressure control valve 1 TT_CURRENT_N215_P_CTRL_1
- Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current N216 pressure control valve 2 TT_CURRENT_N216_P_CTRL_2
- Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current N217 pressure control valve 3 TT_CURRENT_N217_P_CTRL_3
- Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current N218 pressure control valve 4 TT_CURRENT_N218_P_CTRL_4
- Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current N233 pressure control valve 5 TT_CURRENT_N233_P_CTRL_5
- Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current solenoid TT_CURRENT_SOLENOID
- Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current type of driver counter TT_CURRENT_TYPE_DRIVER
- Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Cylinder 1 internal torque TT_CYL_1_INTERNAL_TQ
- Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Cylinder 2 internal torque TT_CYL_2_INTERNAL_TQ
- Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Cylinder 3 internal torque TT_CYL_3_INTERNAL_TQ
- Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Cylinder 4 internal torque TT_CYL_4_INTERNAL_TQ
- Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Cylinder block temperature sensor TT_CYL_BLOCK_T_SENS
- Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Cylinder head temperature TT_CYL_HEAD_T
- Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 1998 to 2023.
Desired torque raw TT_DES_TQ_RAW
- Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Diesel particulate filter exhaust gas flow volume TT_MQB_DPF_EXH_VOL
- Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Number
In testing for 1998 to 2023.
Diesel particulate filter surface temperature TT_DPF_SFC_T
- Service 22
DID 1044 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Direct injections counter TT_DIRECT_INJECTIONS
- Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1998 to 2023.
Drive motor current TT_MOTOR_I
- Service 22
DID 147D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 1998 to 2023.
Drive motor speed TT_MOTOR_RPM_ECM
- Service 22
DID 149A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Drive motor torque TT_MOTOR_TQ
- Service 22
DID 147F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -10922.666 to 10922.333 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Driver demand torque TT_MQB_TCM_DRIVER_DEMAND_TORQUE
- Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Driving mode sensor, hall sensor a TT_DRIVING_MODE_SENS
- Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Driving position TT_DRIVING_POS
- Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Driving resistance index TT_DRIVING_RES_INDEX
- Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 1998 to 2023.
Dynamic average of ignition angle delay adjustment TT_DYNAMIC_AVG_IGN_ANG
- Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Ea888b boost pressure control, adaptation value 0 TT_EA888B_BOOST_P_CTRL_0
- Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 1998 to 2023.
Ea888b boost pressure control, adaptation value 1 TT_EA888B_BOOST_P_CTRL_1
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 1998 to 2023.
Ea888b boost pressure control, adaptation value 2 TT_EA888B_BOOST_P_CTRL_2
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 1998 to 2023.
Ea888b boost pressure control, adaptation value 3 TT_EA888B_BOOST_P_CTRL_3
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 1998 to 2023.
Ea888b boost pressure regulator, commanded TT_EA888B_BOOST_P_CMD
- Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Early ignition counter for toque reduction, cylinder 1 TT_EARLY_IGN_CNT_TOQUE_1
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for toque reduction, cylinder 2 TT_EARLY_IGN_CNT_TOQUE_2
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for toque reduction, cylinder 3 TT_EARLY_IGN_CNT_TOQUE_3
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for toque reduction, cylinder 4 TT_EARLY_IGN_CNT_TOQUE_4
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder 1 TT_EARLY_IGN_CNT_CYL_1
- Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder 2 TT_EARLY_IGN_CNT_CYL_2
- Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder 3 TT_EARLY_IGN_CNT_CYL_3
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder 4 TT_EARLY_IGN_CNT_CYL_4
- Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress early ignition, cylinder 1 TT_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress early ignition, cylinder 2 TT_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress early ignition, cylinder 3 TT_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress early ignition, cylinder 4 TT_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress glow ignition, cylinder 1 TT_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_1
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress glow ignition, cylinder 2 TT_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_2
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress glow ignition, cylinder 3 TT_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_3
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, cylinder suppress glow ignition, cylinder 4 TT_EARLY_IGN_CNT_CYL_SUPPRESS_GLOW_4
- Service 22
DID 4E4B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, total, cylinder 1 TT_EARLY_IGN_CNT_TOT_1
- Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, total, cylinder 2 TT_EARLY_IGN_CNT_TOT_2
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, total, cylinder 3 TT_EARLY_IGN_CNT_TOT_3
- Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter, total, cylinder 4 TT_EARLY_IGN_CNT_TOT_4
- Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Effective injection duration TT_EFFECTIVE_INJ_DUR
- Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1998 to 2023.
EGT after catalyst, model bank b TT_EGT_AFTER_CAT_MODEL_B
- Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 1998 to 2023.
Electric additional coolant pump control, high circle TT_ELEC_ADDITIONAL_CLT
- Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine air mass, specified value TT_ENG_AIR_MASS_SPEC
- Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1998 to 2023.
Engine compartment temperature raw value TT_ENG_COMPARTMENT_T
- Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine control module temperature TT_ENG_CTRL_MODULE_T
- Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2013, 2015, 2017. Supported for 2010 to 2011, 2016.
Engine drag torque TT_ENG_DRAG_TQ
- Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine oil level TT_ENG_OIL_LEVEL_7E0
- Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 1998 to 2023.
Engine oil level current value TT_ENG_OIL_LEVEL
- Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine oil pressure TT_EOP
- Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 157 psi
- Unit
- psi
In testing for 1998 to 2023.
Engine oil sump temperature TT_ENG_OIL_SUMP_T
- Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 1998 to 2023.
Engine oil temperature TT_EOTConfirmed
- Service 22
DID 202F - Module
714 → 77E - Every
1 s - Testing for 1998 to 2014, 2018 to 2023
Example reply from a 2017 Audi TT.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 197 °C
- Unit
- °C
0x43 = 67 → = 9 °C
Confirmed for 2015 to 2017. In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013.
Engine oil temperature TT_EOT_7E0
- Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine oil temperature TT_EOT_7E0_7E0
- Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine oil temperature measured value TT_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine oil temperature sensor 2 TT_EOT_SENS_2
- Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine oil temperature, pulse sensor TT_EOT_PULS
- Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine outlet coolant temperature calculated TT_ENG_OUTLET_ECT_CALC
- Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Engine protection, torque limit TT_ENG_PROTECTION_TQ
- Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine radiator fan request TT_ENG_RADIATOR_FAN_REQ
- Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Engine temperature control actuator TT_ENG_T_CTRL_ACTUATOR
- Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine temperature management actuator, after-run stop TT_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Engine temperature management actuator, duty cycle activation TT_ENG_T_MANAGEMENT_ACTUATOR
- Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine temperature management actuator, raw value TT_ENG_T_MANAGEMENT
- Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Engine temperature management actuator, specified value TT_ENG_T_MANAGEMENT_SPEC
- Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Engine temperature management actuator, stop open TT_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Engine torque TT_ENG_TQ
- Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque TT_ENG_TQ_7E0
- Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque TT_ENG_TQ_7E1
- Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque TT_ENGINE_TORQUE
- Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque TT_MQB_TCM_ENGINE_TORQUE
- Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque limitation TT_ENG_TQ_LIM
- Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque limitation TT_MQB_TCM_ENGINE_TORQUE_LIMITATION
- Service 22
DID 100E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Engine torque loss TT_MQB_TCM_ENGINE_TORQUE_LOSS
- Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Excessive temperature protection TT_EXCESSIVE_T
- Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Exhaust camshaft, adaptation bias TT_EXH_CAM_ADPT_BIAS
- Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 1998 to 2023.
Exhaust camshaft, adaptation sensor tolerance TT_EXH_CAM_ADPT_SENS
- Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 1998 to 2023.
Exhaust gas jet volume in particle filter TT_EXH_GAS_JET_VOLUME
- Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700 L
- Unit
- L
In testing for 1998 to 2023.
Exhaust gas temperature TT_EXH_GAS_T
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature - calculated after catalyst TT_EXH_GAS_T_CALC_AFTER
- Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature before catalytic converter TT_EXH_GAS_T_BEFORE
- Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature before the front catalytic converter, model value TT_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 1 TT_EXH_GAS_T_SENS_1
- Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 1 TT_EXH_GAS_T_SENS_1_7E0
- Service 22
DID 166F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 1, bank 2 TT_EXH_GAS_T_SENS_1_2
- Service 22
DID 1670 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 3 TT_EXH_GAS_T_SENS_3
- Service 22
DID 14BE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 3, bank 2 TT_EXH_GAS_T_SENS_3_2
- Service 22
DID 156F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature sensor 4 TT_EXH_GAS_T_SENS_4
- Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust gas temperature, sensor 4, bank 2 TT_EXH_GAS_T_S4_B2
- Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Exhaust temperature before the catalyst, modeled TT_EXH_T_BEFORE_CAT
- Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Generator load normalized value TT_GENERATOR_LOAD_NORMALIZED_VALUE
- Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Generator load signal TT_GEN_LOAD_SIG
- Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Generator load signal TT_GEN_LOAD_SIG_7E0
- Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Generator load signal TT_GENERATOR_LOAD_SIG
- Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Generator performance TT_GENERATOR_PERFORMANCE
- Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 1998 to 2023.
Generator torque request TT_GENERATOR_TORQUE_REQUEST
- Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Heater circulation pump, nominal value TT_HEATER_CIRCULATION
- Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Heater support pump, specified value TT_HEATER_SUPPORT_PMP_SPEC
- Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Height correction TT_HEIGHT_CORR
- Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.9999
- Unit
- Number
In testing for 1998 to 2023.
High pressure control, adaptation TT_HIGH_P_CTRL_ADPT
- Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 1998 to 2023.
High pressure EGR actuator, activation TT_HIGH_P_EGR_ACTUATOR
- Service 22
DID 1334 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
High pressure regulation, adaptation value TT_HIGH_P_REGULATION
- Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
ID of current driving program TT_ID_CURRENT_DRIVING
- Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
IGA_CYL_KNK, 0 TT_IGA_CYL_KNK_0
- Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
IGA_CYL_KNK, 1 TT_IGA_CYL_KNK_1
- Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
IGA_CYL_KNK, 2 TT_IGA_CYL_KNK_2
- Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
IGA_CYL_KNK, 3 TT_IGA_CYL_KNK_3
- Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
IGA_IGC, 0 TT_IGA_IGC_0
- Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 1998 to 2023.
IGA_IGC, 1 TT_IGA_IGC_1
- Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 1998 to 2023.
IGA_IGC, 2 TT_IGA_IGC_2
- Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 1998 to 2023.
IGA_IGC, 3 TT_IGA_IGC_3
- Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 1998 to 2023.
Ignition angle current cylinder, actual value TT_IGN_ANG_CURRENT_CYL_ACT
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -25 to 25 °
- Unit
- °
In testing for 1998 to 2023.
Ignition timing angle retard, cylinder 4 TT_IGNITION_TIMING_ANGLE_RETARD_C4
- Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 1998 to 2023.
Injection amount deviation cylinder 1 TT_INJ_AMOUNT_DEV_CYL_1
- Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 1998 to 2023.
Injection amount deviation cylinder 2 TT_INJ_AMOUNT_DEV_CYL_2
- Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 1998 to 2023.
Injection amount deviation cylinder 2 TT_INJ_AMOUNT_DEV_CYL_2_7E0
- Service 22
DID 1106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Injection amount deviation cylinder 3 TT_INJ_AMOUNT_DEV_CYL_3
- Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 1998 to 2023.
Injection amount deviation cylinder 4 TT_INJ_AMOUNT_DEV_CYL_4
- Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 1998 to 2023.
Injection amount deviation cylinder 5 TT_INJ_AMOUNT_DEV_CYL_5
- Service 22
DID 1107 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Injection quantity deviation, cylinder 2 TT_INJ_QTY_DEV_CYL_2
- Service 22
DID 204A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Injection quantity deviation, cylinder 5 TT_INJ_QTY_DEV_CYL_5
- Service 22
DID 204B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 2, rail pressure calibration point 1 TT_INJ_2_RAIL_P_1
- Service 22
DID 10D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 1998 to 2023.
Injector 2, rail pressure calibration point 2 TT_INJ_2_RAIL_P_2
- Service 22
DID 10DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 1998 to 2023.
Injector 2: rail pressure calibration point 1 TT_INJ_2_RAIL_P_CAL_PT_1_146E
- Service 22
DID 146E - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 2: rail pressure calibration point 2 TT_INJ_2_RAIL_P_CAL_PT_2_1474
- Service 22
DID 1474 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 2: rail pressure calibration point 3 TT_INJ_2_RAIL_P_CAL_PT_3_147A
- Service 22
DID 147A - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 4, rail pressure calibration point 2 TT_INJ_4_RAIL_P_2
- Service 22
DID 10D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 1998 to 2023.
Injector 5, rail pressure calibration point 2 TT_INJ_5_RAIL_P_2
- Service 22
DID 10DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 1998 to 2023.
Injector 5, rail pressure calibration point 3 TT_INJ_5_RAIL_P_3
- Service 22
DID 10E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 1998 to 2023.
Injector 7: rail pressure calibration point 1 TT_INJ_7_RAIL_P_CAL_PT_1
- Service 22
DID 146D - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 7: rail pressure calibration point 2 TT_INJ_7_RAIL_P_CAL_PT_2
- Service 22
DID 1473 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Injector 7: rail pressure calibration point 3 TT_INJ_7_RAIL_P_CAL_PT_3
- Service 22
DID 1479 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 1998 to 2023.
Inlet flaps - actual value TT_INLET_FLAPS_ACT
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Inlet flaps - requested value TT_INLET_FLAPS_REQ
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Intake air temperature TT_IAT_7E0
- Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 1998 to 2023.
Intake air temperature before throttle valve, raw value TT_IAT_BEFORE_THROTTLE
- Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1998 to 2023.
Intake air temperature in intake manifold TT_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1998 to 2023.
Intake air temperature raw value TT_IAT_RAW
- Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Intake camshaft, adaptation bias TT_INT_CAM_ADPT_BIAS
- Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 1998 to 2023.
Intake camshaft, adaptation sensor tolerance TT_INT_CAM_ADPT_SENS
- Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 1998 to 2023.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Intake manifold pressure raw value TT_INT_MANIFOLD_P_RAW
- Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1998 to 2023.
Intake manifold pressure, commanded TT_INT_MANIFOLD_P_CMD
- Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Intake manifold pressure, corrected TT_INT_MANIFOLD_P
- Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Intake manifold runner control, acknowledgment TT_INT_MANIFOLD_RUNNER_CTRL
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Intake manifold runner control, activation TT_INT_MANIFOLD_RUNNER
- Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Intake model air mass flow filtered value TT_INT_MODEL_AIR_MASS
- Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Intake phase deviation, actual value TT_INT_PHASE_DEV_ACT
- Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 1998 to 2023.
Integrated mass of air since engine start TT_INTEGRATED_MASS_AIR
- Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 1998 to 2023.
Integrated mass of air since the first engine start TT_INTEGRATED_MASS_AIR_SINCE
- Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 1998 to 2023.
Kick down TT_MQB_TCM_KICK_DOWN
- Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Kilometers driven since last event on K1 TT_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1
- Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 1998 to 2023.
Kilometers driven since last event on K2 TT_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2
- Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 1998 to 2023.
Knock retard 2 TT_KNOCK_RETARD_2
- Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 1998 to 2023.
Knock retard 4 TT_KNOCK_RETARD_4
- Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 1998 to 2023.
Knock sensor 1 test TT_KNOCK_SENS_1_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Knock sensor 2 test TT_KNOCK_SENS_2_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Knock sensor 3 test TT_KNOCK_SENS_3_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Knock sensor 4 test TT_KNOCK_SENS_4_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Knock sensor, cylinder 1 TT_KNOCK_SENS_CYL_1
- Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor, cylinder 1 TT_KNOCK_SNS_C1_V_MS
- Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 1998 to 2023.
Knock sensor, cylinder 2 TT_KNOCK_SENS_CYL_2
- Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor, cylinder 2 TT_KNOCK_SENS_CYL_2_7E0
- Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3272
- Unit
- Number
In testing for 1998 to 2023.
Knock sensor, cylinder 2 TT_KNOCK_SNS_C2_V_MS
- Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 1998 to 2023.
Knock sensor, cylinder 3 TT_KNOCK_SENS_CYL_3
- Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor, cylinder 3 TT_KNOCK_SNS_C3_V_MS
- Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 1998 to 2023.
Knock sensor, cylinder 4 TT_KNOCK_SENS_CYL_4
- Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1998 to 2023.
Knock sensor, cylinder 4 TT_KNOCK_SNS_C4_V_MS
- Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 1998 to 2023.
Lambda output value TT_LAMBDA_OUTPUT
- Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 1998 to 2023.
Lambda, actual value TT_LAMBDA_ACT
- Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.9999 to 7.9997
- Unit
- Number
In testing for 1998 to 2023.
Launch control counter, variant 1 TT_LAUNCH_CTRL_CNT_VAR_1
- Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Launch control counter, variant 2 TT_LAUNCH_CTRL_CNT_VAR_2
- Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Long term fuel trim at idle, direct injection TT_LONG_TERM_FUEL_TRIM_IDLE
- Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Long term fuel trim at idle, port injection TT_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017.
Long-term adaptation of intake manifold injection TT_LONG_TERM_ADPT_INT
- Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Long-term adaptation of intake manifold injection at idle TT_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Lost torque adaptation A/C + driving mode TT_LOST_TQ_ADPT_AC
- Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Lost torque adaptation driving mode TT_LOST_TQ_ADPT_DRIVING
- Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Low pressure EGR closing TT_LOW_P_EGR_CLOSING
- Service 22
DID 17F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -699 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Lower adapted coupling point K2 from micro-slip path adaptation TT_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT
- Service 22
DID 110A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
M009, desired solenoid out 10 TT_M009_DES_SOLENOID_10
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
M009, desired solenoid out 11 TT_M009_DES_SOLENOID_11
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
M009, desired solenoid out 12 TT_M009_DES_SOLENOID_12
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
M009, desired solenoid out 13 TT_M009_DES_SOLENOID_13
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
M009, desired solenoid out 14 TT_M009_DES_SOLENOID_14
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Main cat oxygen storage capacity age correction factor TT_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 1998 to 2023.
Manifold absolute pressure, raw value TT_MAP_RAW
- Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Manual engine starts counter TT_MANUAL_ENG_STARTS
- Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Mass air flow over throttle valve TT_MAF_OVER_THROTTLE
- Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1998 to 2023.
Mass air flow rate TT_MAF_RATE
- Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047
- Unit
- Raw value
In testing for 1998 to 2023.
Mass air flow through throttle TT_MAF_THROUGH_THROTTLE
- Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Mass air flow, commanded TT_MAF_CMD
- Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Mass flow through throttle valve TT_MASS_FLOW_THROUGH
- Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 1998 to 2023.
Max permissible engine torque TT_MAX_PERMISSIBLE_ENG
- Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Maximum ECU temperature TT_MAX_ECU_T
- Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 1998 to 2023.
Maximum filling correction factor from knock control TT_MAX_FILLING_CORR
- Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96
- Unit
- Number
In testing for 1998 to 2023.
Maximum oil level for the service interval TT_MAX_OIL_LEVEL
- Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 1998 to 2023.
Mean engine air mass TT_MEAN_ENG_AIR_MASS
- Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1998 to 2023.
Mean injection quantity TT_MEAN_INJ_QTY
- Service 22
DID 2097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1998 to 2023.
Mean injection quantity TT_MEAN_INJ_QUANTITY
- Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1998 to 2023.
Mileage with ECU installed TT_MILEAGE_ECU
- Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 1998 to 2023.
Minimum oil level for the service interval TT_MIN_OIL_LEVEL
- Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 1998 to 2023.
Misfires counter:, cylinder 1 TT_MIS_CNT_1
- Service 22
DID 147E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires counter:, cylinder 2 TT_MIS_CNT_2
- Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires counter:, cylinder 3 TT_MIS_CNT_3
- Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires counter:, cylinder 5 TT_MIS_CNT_5
- Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires counter:, cylinder 6 TT_MIS_CNT_6
- Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions 2 TT_MIS_PER_1000_2_7E0_7E0
- Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions 4 TT_MIS_PER_1000_REVOLUTIONS_4_7E0
- Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 1, port injection TT_MIS_PER_1000_1
- Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 2 TT_MIS_PER_1000_2_7E0
- Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 2, port injection TT_MIS_PER_1000_2
- Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 3 TT_MIS_PER_1000_3_7E0
- Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 3, port injection TT_MIS_PER_1000_3
- Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 revolutions, cylinder 4, port injection TT_MIS_PER_1000_4
- Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires total TT_MIS_TOT
- Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 1 TT_MIS_1
- Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 1 TT_MISFIRES_C1_7E0
- Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 2 TT_MIS_2
- Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 2 TT_MISFIRES_C2
- Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 3 TT_MIS_3
- Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 3 TT_MISFIRES_C3_7E0
- Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 4 TT_MIS_4
- Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires, cylinder 4 TT_MISFIRES_C4
- Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Mixture adaptation factor at partial load TT_MIXTURE_ADPT_FACTOR
- Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
N_32 TT_N_32
- Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 1998 to 2023.
NL_PRE, 0 TT_NL_PRE_0
- Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 1998 to 2023.
NL_PRE, 1 TT_NL_PRE_1
- Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 1998 to 2023.
NL_PRE, 2 TT_NL_PRE_2
- Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 1998 to 2023.
NL_PRE, 3 TT_NL_PRE_3
- Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 1998 to 2023.
Number of injections TT_NUM_INJECTIONS
- Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Number of times the permitted centrifugal oil temperature has been exceeded TT_NUM_TIMES_PERMITTED_T
- Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Number of warnings due to increased centrifugal oil temperature TT_NUM_WARN_HI_CENTRIF_T
- Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil ash limit TT_OIL_ASH_LIM
- Service 22
DID 1793 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Oil ash residue TT_OIL_ASH_RESIDUE
- Service 22
DID 208A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1310
- Unit
- Raw value
In testing for 1998 to 2023.
Oil fill level TT_PQ35_OIL_FILL_LEVEL
- Service 22
DID 2006 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
In testing for 1998 to 2023.
Oil level method 1 TT_OIL_LEVEL_METHOD_1
- Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 1998 to 2023.
Oil level method 2 TT_OIL_LEVEL_METHOD_2
- Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 1998 to 2023.
Oil level method 3 TT_OIL_LEVEL_METHOD_3
- Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 1998 to 2023.
Oil level test method 1 TT_OIL_LEVEL_TEST_1
- Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Oil level test method 2 TT_OIL_LEVEL_TEST_2
- Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Oil level test method 3 TT_OIL_LEVEL_TEST_3
- Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Oil level, average dynamic value TT_OIL_LEVEL_AVG
- Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 1998 to 2023.
Oil level, last valid dynamic value TT_OIL_LEVEL_LAST_VALID
- Service 22
DID 10F3 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 1998 to 2023.
Oil level, static measured TT_OIL_LEVEL_STATIC
- Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 1998 to 2023.
Oil level, static measurement TT_OIL_LEVEL_STATIC_7E0
- Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 1998 to 2023.
Oil p TT_OIL_P
- Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Oil pressure actual current TT_MQB_TCM_EOP_ACTUAL_I
- Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 1998 to 2023.
Oil pressure control valve activation pulse duty factor TT_OIL_P_CTRL_VLV
- Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Oil pressure control valve, activation pulse duty factor TT_OIL_P_CTRL_VLV_ACTIVATION
- Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Oil pressure sensor raw value TT_OIL_P_SENS_RAW
- Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure sensor-piston cooling nozzle switch, status TT_OIL_P_SENS_PISTON
- Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure sensor, raw value TT_OIL_P_SENS_RAW_7E0
- Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure switch activation, high pressure TT_OIL_P_SWITCH_P
- Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure switch for high pressure, closed TT_OIL_P_SWITCH_HIGH_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Oil pressure switch for low pressure, closed TT_OIL_P_SWITCH_LOW_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2023.
Oil pressure switch for piston-cooling jets, closed TT_OIL_P_SWITCH_PISTON
- Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure switch valve activation TT_OIL_P_SWITCH_VLV
- Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure target TT_OIL_P_TGT
- Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Oil pressure target TT_OIL_P_TGT_7E0
- Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Oil pressure valve for piston cooling nozzles, control switch button ratio TT_OIL_P_VLV_PISTON
- Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Oil pressure valve switch, control TT_OIL_P_VLV_SWITCH
- Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Oil pressure, actual value TT_OIL_P_ACT_7E0
- Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Oil pressure, actual value TT_OIL_P_ACT_7E0_2
- Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Oil pressure, actual value TT_OIL_P_ACT_7E0_2_7E0
- Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Oil temperature TT_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Oil warning threshold TT_OIL_WARN_THR
- Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 1998 to 2023.
Open cam shaft angle at quantity control valve TT_OPEN_CAM_SHFT_ANG
- Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1998 to 2023.
Outside temperature TT_OUTSIDE_T
- Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 1998 to 2023.
Oxygen control, adaptation value at part. load TT_OXYGEN_CTRL_ADPT
- Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Oxygen sensor 1 bank 1 ceramic temperature TT_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 1998 to 2023.
Particle sensor, time in op.mode measurement TT_PARTICLE_SENS_TIME
- Service 22
DID 46D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 s
- Unit
- s
In testing for 1998 to 2023.
Pilot injection 1, activation start TT_PRE_INJ_1_ACTIVATION
- Service 22
DID 12C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 1998 to 2023.
Pilot injection 2, activation start TT_PRE_INJ_2_ACTIVATION
- Service 22
DID 12C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 1998 to 2023.
Pilot injection 3 start TT_PRE_INJ_3_START
- Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 1998 to 2023.
Pilot injection 3, activation duration TT_PRE_INJ_3_ACTIVATION
- Service 22
DID 121A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 1998 to 2023.
Pilot injection 3, activation start TT_PRE_INJ_3_ACTIVATION_START
- Service 22
DID 121D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655 to 655 °
- Unit
- °
In testing for 1998 to 2023.
Piston cooling nozzles, control TT_PISTON_COOLING
- Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Piston-cooling jets, activation TT_PISTON_COOLING_JETS
- Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Port injection injections counter TT_PORT_INJ_INJECTIONS
- Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1998 to 2023.
Post injection 1 TT_POST_INJ_1
- Service 22
DID 081A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Post injection 1 TT_POST_INJ_1_7E0
- Service 22
DID 205D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1998 to 2023.
Post injection 2 TT_POST_INJ_2
- Service 22
DID 080C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Post injection 2 TT_POST_INJ_2_7E0_7E0
- Service 22
DID 205F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1998 to 2023.
Post injection 3 TT_POST_INJ_3
- Service 22
DID 081B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 1998 to 2023.
Post injection 3 TT_POST_INJ_3_7E0
- Service 22
DID 20C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1998 to 2023.
Post-injection 1 duration TT_PQ35_POST_INJ_1_DURATION
- Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 1998 to 2023.
Post-injection 2, activation duration TT_POST_INJ_2_7E0
- Service 22
DID 121B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1 to 13.1 ms
- Unit
- ms
In testing for 1998 to 2023.
Pressure before throttle valve - actual value TT_P_BEFORE_THROTTLE_ACT
- Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 1998 to 2023.
Pressure before throttle valve - sensor measured TT_P_BEFORE_THROTTLE
- Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 1998 to 2023.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 TT_PSN_EDGE_REL_AD_CAM_1
- Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 1998 to 2023.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 TT_PSN_EDGE_REL_AD_CAM_2
- Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 1998 to 2023.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 TT_PSN_EDGE_REL_AD_CAM_SAVE_1
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 1998 to 2023.
Radiator fan 1, commanded duty TT_RADIATOR_FAN_1_CMD
- Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Radiator fan 2, commanded duty TT_RADIATOR_FAN_2_CMD
- Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 1998 to 2023.
Rated drive torque TT_RATED_DRIVE_TQ
- Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Reached maximum temperature TT_PQ35_REACHED_MAXIMUM_T
- Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1998 to 2023.
Rear cat converter temperature, main catalytic converter model value TT_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 1998 to 2023.
Reducing agent tank volume, act. value filtered TT_REDUCING_AGENT_TANK_ACT
- Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 L
- Unit
- L
In testing for 1998 to 2023.
Relative load value TT_REL_LOAD
- Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 1998 to 2023.
Relay for reserve coolant pump status TT_RELAY_RESERVE_CLT
- Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Requested torque, amount for auxiliary units TT_REQ_TQ_AMOUNT
- Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Reserve torque TT_RESERVE_TQ
- Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Result of crankcase ventilation test, fail TT_RESULT_CRANKCASE_VENTILATION_TEST
- Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Result of crankcase ventilation test, successful TT_RESULT_CRANKCASE
- Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Route data, active TT_ROUTE_DATA_ACTIVE
- Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Secondary air injection sensor 1 TT_SECONDARY_AIR_INJ_1
- Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1998 to 2023.
SEG_AD_MMV_ER_H, 0 TT_SEG_AD_MMV_ER_H_0
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_H, 2 TT_SEG_AD_MMV_ER_H_2
- Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_H, 3 TT_SEG_AD_MMV_ER_H_3
- Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_L, 0 TT_SEG_AD_MMV_ER_L_0
- Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_L, 2 TT_SEG_AD_MMV_ER_L_2
- Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_L, 3 TT_SEG_AD_MMV_ER_L_3
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_MID, 0 TT_SEG_AD_MMV_ER_MID_0
- Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_MID, 1 TT_SEG_AD_MMV_ER_MID_1
- Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER_MID, 2 TT_SEG_AD_MMV_ER_MID_2
- Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER, 1 TT_SEG_AD_MMV_ER_1
- Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER, 2 TT_SEG_AD_MMV_ER_2
- Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
SEG_AD_MMV_ER, 3 TT_SEG_AD_MMV_ER_3
- Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 1998 to 2023.
Sensor for particle filter differential pressure, raw value TT_SENS_PARTICLE_FLT_P
- Service 22
DID 39E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Service limit TT_SERVICE_LIM
- Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1998 to 2023.
Service limit TT_SERVICE_LIM_7E0
- Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1998 to 2023.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2010 to 2011, 2015 to 2016.
Spark efficiency deviation at idle, maximum TT_SPARK_EFFICIENCY_DEV_MAX
- Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Spark efficiency deviation at part load, maximum TT_SPARK_EFFICIENCY_DEV_PART_MAX
- Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Stop signal switch TT_MQB_TCM_STOP_SIGNAL_SWITCH
- Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Sum of misfires counter TT_SUM_MIS_CNT
- Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Tank fill level diagnostic reference value TT_TANK_FILL_LEVEL
- Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 1998 to 2023.
TCO_1_ST TT_TCO_1_ST
- Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
TCO_1_SYS TT_TCO_1_SYS
- Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Temperature at air conditioner heat exchanger output TT_T_AC_HEAT_EXCHANGER
- Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
Temperature sensor for engine temperature management TT_T_SENS_ENG_T
- Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Temperature sensor for engine temperature management, target value TT_T_SENS_ENG_T_TGT
- Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Test of catalytic converter status, canceled TT_TEST_CATALYTIC_CONV_STAT
- Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Test of catalytic converter, measured value TT_TEST_CATALYTIC_CONV
- Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Number
In testing for 1998 to 2023.
Thermostat, actual TT_THERMOSTAT_ACT
- Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Thermostat, commanded TT_THERMOSTAT_CMD
- Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Throttle regulator nominal value TT_THROTTLE_REGULATOR
- Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
TI_1_MPI, 0 TT_TI_1_MPI_0
- Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_1_MPI, 1 TT_TI_1_MPI_1
- Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_1_MPI, 2 TT_TI_1_MPI_2
- Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_1_MPI, 3 TT_TI_1_MPI_3
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_1, 1 TT_TI_MES4_PLS_1_1
- Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_1, 2 TT_TI_MES4_PLS_1_2
- Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_1, 3 TT_TI_MES4_PLS_1_3
- Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_2, 0 TT_TI_MES4_PLS_2_0
- Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_2, 1 TT_TI_MES4_PLS_2_1
- Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_2, 2 TT_TI_MES4_PLS_2_2
- Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_2, 3 TT_TI_MES4_PLS_2_3
- Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_3, 0 TT_TI_MES4_PLS_3_0
- Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_3, 1 TT_TI_MES4_PLS_3_1
- Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_3, 2 TT_TI_MES4_PLS_3_2
- Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
TI_MES4_PLS_3, 3 TT_TI_MES4_PLS_3_3
- Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 1998 to 2023.
Time in after-run TT_TIME_AFTERRUN
- Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 1998 to 2023.
Time since reset TT_TIME_SINCE_RESET
- Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 1998 to 2023.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017. Supported for 2010 to 2011, 2013, 2015 to 2016.
Timing angle retardation cylinder 1 TT_PQ35_TIMING_ANGLE_RETARDATION_CYL_1
- Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
Timing angle retardation cylinder 2 TT_PQ35_TIMING_ANGLE_RETARDATION_CYL_2
- Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
Timing angle retardation cylinder 3 TT_PQ35_TIMING_ANGLE_RETARDATION_CYL_3
- Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
Timing angle retardation cylinder 4 TT_PQ35_TIMING_ANGLE_RETARDATION_CYL_4
- Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation after chain replacement, exhaust bank 1 TT_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation after chain replacement, intake bank 1 TT_TIM_DEV_AFTER_CHAIN_1
- Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation after other repairs, intake bank 1 TT_TIM_DEV_AFTER_OTHER_1
- Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation after other repairs, intake bank 1 TT_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation current value exhaust bank 1 TT_TIM_DEV_CURRENT_EXH_1
- Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Timing deviation current value intake bank 1 TT_TIM_DEV_CURRENT_INT_1
- Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 1998 to 2023.
Torque converter: torque loss TT_TORQUE_CONVERTER_TORQUE_LOSS
- Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque factor TT_TQ_FACTOR
- Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Torque increase request from ESP TT_TQ_INCREASE_REQ_ESP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque limitation TT_TORQUE_LIMITATION
- Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque limitation TT_TQ_LIM
- Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque limitation TT_TQ_LIM_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque limitation, clutch protection TT_TQ_LIM_CLU
- Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque loss adaptation TT_TQ_LOSS_ADPT
- Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque loss adaptation at idle TT_TQ_LOSS_ADPT_IDLE
- Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque loss adaptation, A/C compressor TT_TQ_LOSS_ADPT_AC_COMP_7E0
- Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque reduction request from ESP TT_TQ_REDUCTION_REQ_ESP
- Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque request, sum of auxiliary aggregate TT_TQ_REQ_SUM_AUXILIARY
- Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque transmitting function, ratio TT_TQ_TRANSMITTING
- Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 1998 to 2023.
Total mass of gasoline and ethyl alcohol in oil TT_TOT_MASS_GASOLINE
- Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 1998 to 2023.
Transmission drag torque TT_TCM_DRAG_TQ
- Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Transmission fluid temperature, calculated TT_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1998 to 2023.
Transmission fluid temperature, modeled maximum reached TT_ATF_T_MODELED_MAX_REACHED
- Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1998 to 2023.
Transmission torque losses TT_TCM_TQ_LOSSES
- Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Turbine actuator 1 bank 1 activation TT_PQ35_TURB_ACT_1_B1
- Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Turbine actuator 1 bank 1: activation TT_ACT
- Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2017.
Upper adapted coupling point K1 from macro slip path adaptation TT_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Upper adapted coupling point K2 from macro slip path adaptation TT_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Valve lift system, result of last switch, intake TT_VLV_LIFT_SYSTEM
- Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Valve lift system, valve lift, exhaust TT_VLV_LIFT_SYSTEM_VLV_LIFT
- Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Valve lift system, valve lift, intake TT_VLV_LIFT_SYSTEM_VLV
- Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Valve timing, the difference between the, actual and the set angle TT_VLV_TIM_DIFF_ACT_SET
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 1998 to 2023.
Variable valve timing, intake, bank 1, regulation TT_VARIABLE_VLV_TIM_INT_1
- Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Variable valve timing, intake, bank 1, switch on TT_VARIABLE_VLV_TIM_INT_1_ON
- Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Wear index %, 0=new engine TT_WEAR_INDEX_0_NEW_ENG
- Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Internal
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2017.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013, 2015, 2017. Supported for 2016.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2013, 2015, 2017. Supported for 2016.
Fuel
Activation of fuel pump electronics TT_ACTIVATION_FUEL_PMP
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Counter of fuel entry in oil TT_CNT_FUEL_ENTRY_OIL
- Service 22
DID 399F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Error counter bad fuel TT_ERROR_CNT_BAD_FUEL
- Service 22
DID 44BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1998 to 2023.
Fuel consumption TT_FUEL_CONS
- Service 22
DID 113F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 1998 to 2023.
Fuel consumption - actual drive cycle TT_FUEL_CONS_ACT_DRIVE
- Service 22
DID 1519 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 1998 to 2023.
Fuel consumption per driving cycle TT_FUEL_CONS_PER
- Service 22
DID 51D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 1998 to 2023.
Fuel flow TT_FUEL_FLOW
- Service 22
DID 10A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 L
- Unit
- L
In testing for 1998 to 2023.
Fuel high pressure, actual value TT_FUEL_HIGH_P_ACT
- Service 22
DID 2027 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 1998 to 2023.
Fuel high pressure, control deviation TT_FUEL_HIGH_P_CTRL_DEV
- Service 22
DID 20BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 bar
- Unit
- bar
In testing for 1998 to 2023.
Fuel high pressure, specified value TT_FUEL_HIGH_P_SPEC
- Service 22
DID 293B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 1998 to 2023.
Fuel injector time deviation, cylinder 1 TT_FUEL_INJ_TIME_DEV_1
- Service 22
DID 2000 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel injector time deviation, cylinder 2 TT_FUEL_INJ_TIME_DEV_2
- Service 22
DID 207B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel injector time deviation, cylinder 2 TT_FUEL_INJ_TIME_DEV_CYL_2
- Service 22
DID 21C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel injector time deviation, cylinder 3 TT_FUEL_INJ_TIME_DEV_3
- Service 22
DID 2100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel injector time deviation, cylinder 4 TT_FUEL_INJ_TIME_DEV_4
- Service 22
DID 2101 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel level TT_FLI_7E0
- Service 22
DID 1008 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 1998 to 2023.
Fuel level input % TT_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Fuel low pressure, actual value TT_FUEL_LOW_P_ACT
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1998 to 2023.
Fuel low pressure, specified value TT_FUEL_LOW_P_SPEC
- Service 22
DID 2932 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 1998 to 2023.
Fuel mass request, integral controller TT_FUEL_MASS_REQ_I_CTL
- Service 22
DID 130D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel mass request, proportional controller TT_FUEL_MASS_REQ_P_CTL
- Service 22
DID 1312 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel metering valve TT_FUEL_METERING_VLV
- Service 22
DID 209A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Fuel mix correction coefficient TT_FUEL_MIX_CORR
- Service 22
DID 1710 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to -73.1003
- Unit
- Number
In testing for 1998 to 2023.
Fuel part from EVAP system TT_FUEL_PART_EVAP
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -0.9996 to 0.9918
- Unit
- Number
In testing for 1998 to 2023.
Fuel pressure regulator valve: specified value rail pressure TT_SPEC_VALUE_RAIL_P
- Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 1998 to 2023.
Fuel pressure, low actual TT_FUEL_P_LOW_ACT
- Service 22
DID 1AB8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Fuel pump adaptation TT_FUEL_PMP_ADPT
- Service 22
DID 11C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Fuel pump specified value TT_FUEL_PMP_SPEC
- Service 22
DID 1109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Fuel pump, commanded duty TT_FUEL_PMP_CMD_DUTY
- Service 22
DID 11A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.998 %
- Unit
- %
In testing for 1998 to 2023.
Fuel rate TT_FUEL_RATE
- Service 22
DID 204C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 1998 to 2023.
Fuel rate difference, injector/sensor TT_FUEL_RATE_DIFF_INJ
- Service 22
DID 180A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127.9983 to 127.9944 L
- Unit
- L
In testing for 1998 to 2023.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2011, 2013. Supported for 2010, 2015 to 2017.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | No status reported: this fuel system is not running or not present, e.g. the engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
68 | OL-Drive B1+B2 | Open loop due to driving conditions on bank 1 and bank 2 (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2011, 2013. Supported for 2010, 2015 to 2017.
Fuel tank fill level TT_FUEL_TANK_FILL_LEVEL
- Service 22
DID 24FC - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 1998 to 2023.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2015, 2017. Supported for 2016.
Fuel temperature TT_FUEL_T
- Service 22
DID 128A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 1998 to 2023.
Fuel temperature TT_FUEL_T_7E0
- Service 22
DID 203E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1998 to 2023.
Fuel temperature TT_FUEL_T_7E0_2
- Service 22
DID 111C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1998 to 2023.
High fuel pressure control deviation TT_HIGH_FUEL_P_CONTROL_DEVIATION
- Service 22
DID 121F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 1998 to 2023.
High fuel pressure, actual TT_HIGH_FUEL_P_ACT
- Service 22
DID 159F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 1998 to 2023.
High fuel pressure, actual value TT_HIGH_FUEL_P_ACT_7E0
- Service 22
DID 4460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 1998 to 2023.
High fuel pressure, commanded TT_HIGH_FUEL_P_CMD
- Service 22
DID 11D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 1998 to 2023.
High fuel pressure, regulation error TT_HIGH_FUEL_P
- Service 22
DID 11D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 1998 to 2023.
High fuel pressure, target TT_HIGH_FUEL_P_TGT
- Service 22
DID 111B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 1998 to 2023.
Long term fuel trim at idle TT_LONG_TERM_FUEL_TRIM_7E0
- Service 22
DID 110E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 %
- Unit
- %
In testing for 1998 to 2023.
Long term fuel trim at idle TT_LONG_TERM_FUEL_TRIM_IDLE_7E0
- Service 22
DID 4381 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 1998 to 2023.
Long term fuel trim bank 1 TT_LONG_TERM_FUEL_TRIM_1
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 1998 to 2023.
Long term fuel trim direct injection at load TT_LONG_TERM_FUEL_TRIM
- Service 22
DID 1779 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 1998 to 2023.
Long term fuel trim port injection at load TT_LONG_TERM_FUEL_TRIM_PORT
- Service 22
DID 177B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 1998 to 2023.
Low fuel pressure, actual TT_LOW_FUEL_P_ACT
- Service 22
DID 11C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Low fuel pressure, commanded TT_LOW_FUEL_P_CMD
- Service 22
DID 11CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 1998 to 2023.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual TT_RAT_EVAPORATED_FUEL_ACT
- Service 22
DID 1711 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.9915
- Unit
- Number
In testing for 1998 to 2023.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum TT_RAT_EVAPORATED_FUEL_MAX
- Service 22
DID 1712 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.992
- Unit
- Number
In testing for 1998 to 2023.
Short term fuel trim bank 1 TT_SHORT_TERM_FUEL_TRIM_1
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 1998 to 2023.
Movement
Acceleration TT_ACCEL
- Service 22
DID 2116 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Acceleration TT_ACCEL_7E0
- Service 22
DID 10CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Acceleration TT_ACCELERATION
- Service 22
DID 1187 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Acceleration TT_ACCELERATION_29BIT
- Service 22
DID 12B0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Acceleration or deceleration mode TT_ACCEL_DECCELERATION
- Service 22
DID 2118 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Accelerator pedal limit TT_PQ35_LIM_ACCEL_PED
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Accelerator pedal position TT_ACCEL_PEDAL_POS
- Service 22
DID 3804 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Accelerator pedal position TT_ACCEL_PEDAL_POS_7E1
- Service 22
DID F449 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Accelerator pedal position 1 TT_ACCEL_PEDAL_POS_1
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Accelerator pedal position 2 TT_ACCEL_PEDAL_POS_2
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Accelerator pedal torque limit TT_ACCEL_PEDAL_TQ_LIM
- Service 22
DID 1059 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Aux. hydraulic pump RPM TT_AUX_HYDRAULIC_PMP_RPM
- Service 22
DID 70D6 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Camshaft speed TT_CAM_SPD
- Service 22
DID 1092 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Camshaft speed TT_CAMSHAFT_VSS
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Compressor speed TT_COMP_SPD
- Service 22
DID 46E1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Crankshaft speed TT_CRANKSHAFT_VSS
Pelican can show this parameter as the engine speed.
- Service 22
DID 16F3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Crankshaft speed, RPM TT_CRANK_SPD_RPM
- Service 22
DID 206E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Engine RPM TT_RPM
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Engine RPM at idle required TT_ENGINE_RPM_AT_IDLE_REQUIRED
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Front left wheel speed TT_FL_VSS
- Service 22
DID 1800 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Front left wheel speed TT_TIRE_FL_SPD_V3
- Service 22
DID 1002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Front right wheel speed TT_FR_VSS
- Service 22
DID 1801 - Module
713 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Front right wheel speed TT_TIRE_FR_SPD_V3
- Service 22
DID 1001 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Idle speed specified rpm TT_IDLE_SPD_SPEC_RPM
- Service 22
DID 4056 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Injection speed injector 0 TT_INJ_SPD_INJ_0
- Service 22
DID 10A4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Injection speed injector 1 TT_INJ_SPD_INJ_1
- Service 22
DID 10A5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Injection speed injector 2 TT_INJ_SPD_INJ_2
- Service 22
DID 10A6 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Injection speed injector 3 TT_INJ_SPD_INJ_3
- Service 22
DID 10A8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Input shaft speed 1 TT_INPUT_SHFT_SPD_1
- Service 22
DID 70E0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Input shaft speed 2 TT_INPUT_SHFT_SPD_2
- Service 22
DID 70E1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Lateral acceleration TT_LATERAL_ACCEL
- Service 22
DID 1644 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Longitudinal acceleration TT_LONGITUDINAL_ACCEL
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Longitudinal acceleration, raw TT_LONGTITUDINAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
Misfires per 1000 rpm, all cylinders TT_MIS_PER_1000_RPM_ALL
- Service 22
DID 148B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 rpm:, cylinder 1 TT_MIS_PER_1000_RPM_1
- Service 22
DID 1484 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 rpm:, cylinder 3 TT_MIS_PER_1000_RPM_3
- Service 22
DID 1486 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 rpm:, cylinder 4 TT_MIS_PER_1000_RPM_4
- Service 22
DID 1485 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 rpm:, cylinder 5 TT_MIS_PER_1000_RPM_5
- Service 22
DID 1489 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires per 1000 rpm:, cylinder 6 TT_MIS_PER_1000_RPM_6
- Service 22
DID 1487 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires/1000 rpm, cylinder 1 TT_MISFIRES_1000_RPM_C1
- Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires/1000 rpm, cylinder 2 TT_MISFIRES_1000_RPM_C2
- Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires/1000 rpm, cylinder 3 TT_MISFIRES_1000_RPM_C3
- Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Misfires/1000 rpm, cylinder 4 TT_MISFIRES_1000_RPM_C4
- Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Mixture adaptation factor at idle speed TT_MIXTURE_ADPT_FACTOR_IDLE
- Service 22
DID 3997 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Rear left wheel speed TT_RL_VSS
- Service 22
DID 1802 - Module
713 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Rear left wheel speed TT_TIRE_RL_SPD_V3
- Service 22
DID 1004 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Rear right wheel speed TT_RR_VSS
- Service 22
DID 1803 - Module
713 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Rear right wheel speed TT_TIRE_RR_SPD_V3
- Service 22
DID 1003 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Reducing agent pump, differential speed calculated TT_REDUCING_AGENT_PMP
- Service 22
DID 18CC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Specified idle RPM TT_MQB_DQ250_SPECIFIED_IDLE_RPM
- Service 22
DID 3871 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Speed output TT_MQB_DQ250_SPD_OUTPUT
- Service 22
DID 1009 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Transmission input speed TT_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A
- Service 22
DID 380A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Transmission output speed TT_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B
- Service 22
DID 380B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Vehicle lateral acceleration, raw value TT_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 g
- Unit
- g
In testing for 1998 to 2023.
Vehicle speed TT_VSS
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Vehicle speed TT_VSS_7E1
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2011, 2013, 2015, 2017. Supported for 2010, 2016.
Vehicle speed ESP TT_VSS_ESP
- Service 22
DID 1005 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Vehicle speed from transmission TT_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION
Pelican can show this parameter as the speed.
- Service 22
DID 100A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Vehicle speed, HR TT_VSS_HR
- Service 22
DID 2106 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 1998 to 2023.
Yaw acceleration, raw value TT_YAW_ACCEL_RAW
- Service 22
DID 15D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 1998 to 2023.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2011, 2017. Supported for 2010, 2013, 2015 to 2016.
Tires
Tire #1 position TT_TID_1
- Service 22
DID 18A0 - Module
70B - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | FL | Front left |
1 | FR | Front right |
2 | RL | Rear left |
3 | RR | Rear right |
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #1 pressure TT_TP_1
- Service 22
DID 18A0 - Module
70B - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #2 position TT_TID_2
- Service 22
DID 18A1 - Module
70B - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | FL | Front left |
1 | FR | Front right |
2 | RL | Rear left |
3 | RR | Rear right |
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #2 pressure TT_TP_2
- Service 22
DID 18A1 - Module
70B - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #3 position TT_TID_3
- Service 22
DID 18A2 - Module
70B - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | FL | Front left |
1 | FR | Front right |
2 | RL | Rear left |
3 | RR | Rear right |
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #3 pressure TT_TP_3
- Service 22
DID 18A2 - Module
70B - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #4 position TT_TID_4
- Service 22
DID 18A3 - Module
70B - Every
15 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | FL | Front left |
1 | FR | Front right |
2 | RL | Rear left |
3 | RR | Rear right |
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Tire #4 pressure TT_TP_4
- Service 22
DID 18A3 - Module
70B - Every
15 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Transmission
Actual position of gear positioner a TT_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A
- Service 22
DID 3852 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 1998 to 2023.
Actual position of gear positioner b TT_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B
- Service 22
DID 385A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 1998 to 2023.
Actual position of gear positioner c TT_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C
- Service 22
DID 3862 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 1998 to 2023.
Actual position of gear positioner d TT_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D
- Service 22
DID 386A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 1998 to 2023.
Adaptation counter PF lockup clutch TT_ADPT_CNT_PF_LOCKUP
- Service 22
DID 1103 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, clutch a TT_ADPT_CNT_CLU
- Service 22
DID 7085 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, clutch b TT_ADPT_CNT_CLU_B
- Service 22
DID 7089 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, clutch c TT_ADPT_CNT_CLU_C
- Service 22
DID 708D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, clutch d TT_ADPT_CNT_CLU_D
- Service 22
DID 7091 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, clutch e TT_ADPT_CNT_CLU_E
- Service 22
DID 7095 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, fast fill time, clutch a TT_ADPT_CNT_FAST_FILL
- Service 22
DID 7087 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, fast fill time, clutch b TT_ADPT_CNT_FAST_FILL_B
- Service 22
DID 708B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, fast fill time, clutch c TT_ADPT_CNT_FAST_FILL_C
- Service 22
DID 708F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, fast fill time, clutch d TT_ADPT_CNT_FAST_FILL_D
- Service 22
DID 7093 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, fast fill time, clutch e TT_ADPT_CNT_FAST_FILL_E
- Service 22
DID 7097 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Adaptation counter, torque converter lockup clutch TT_ADPT_CNT_TSF_LOCKUP
- Service 22
DID 1101 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Adaptation fill time, torque converter lockup clutch TT_ADPT_INFLATION_TIME
- Service 22
DID 1100 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 1998 to 2023.
Adaptation inflation current PF lockup clutch TT_ADPT_INFLATION
- Service 22
DID 1102 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch 1 actual pressure TT_PQ35_CLUTCH_1_ACTUAL_P
- Service 22
DID 38EB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 1 actual pressure raw value TT_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE
- Service 22
DID 10F9 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 1 failed adaptations counter TT_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER
- Service 22
DID 10CC - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Clutch 1 lower adaptation point TT_CLU_1_LO_ADPT_POINT
- Service 22
DID 1120 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 1 nominal pressure TT_CLU_1_NOMINAL_P
- Service 22
DID 125C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 1 successful adaptations counter TT_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10C9 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Clutch 1 upper adaptation point TT_CLU_1_HI_ADPT_POINT
- Service 22
DID 1124 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 1 valve current: actual TT_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL
- Service 22
DID 3835 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch 1 valve current: specified TT_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED
- Service 22
DID 3834 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch 2 actual pressure TT_PQ35_CLUTCH_2_ACTUAL_P
- Service 22
DID 38EA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 2 failed adaptations counter TT_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER
- Service 22
DID 10ED - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Clutch 2 lower adaptation point TT_CLU_2_LO_ADPT_POINT
- Service 22
DID 1121 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 2 successful adaptations counter TT_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10EA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Clutch 2 upper adaptation point TT_CLU_2_HI_ADPT_POINT
- Service 22
DID 1125 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Clutch 2 valve current: actual TT_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL
- Service 22
DID 383E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch 2 valve current: specified TT_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED
- Service 22
DID 383D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch adaptation values initial kill point 0 for K1 TT_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1
- Service 22
DID 1156 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch adaptation values initial kill point 0 for K2 TT_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2
- Service 22
DID 1157 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch adaptation values lower current point adaptation K1 TT_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1
- Service 22
DID 1158 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch adaptation values lower current point adaptation K2 TT_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2
- Service 22
DID 1159 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Clutch overheating, clutch TT_CLU_OVERHEATING_CLU
- Service 22
DID 17FD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Clutch temperature TT_CLU_T
- Service 22
DID 1259 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1998 to 2023.
Correction values for main press adaptation: high press on clutch 1 TT_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1
- Service 22
DID 1181 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Correction values for main press adaptation: low press on clutch 1 TT_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1
- Service 22
DID 1180 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Correction values for main pressure adaptation high pressure on clutch 2 TT_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2
- Service 22
DID 1183 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Correction values for main pressure adaptation low pressure on clutch 2 TT_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2
- Service 22
DID 1182 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 1998 to 2023.
Current gear TT_CURRENT_GEAR
- Service 22
DID 3EDE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 1998 to 2023.
Current gear TT_MQB_TCM_I_GEAR_DQ200
- Service 22
DID 3816 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253
- Unit
- Number
In testing for 1998 to 2023.
Current lower pressure point clutch 1 from current to pressure adaptation TT_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1130 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Current lower pressure point clutch 2 from current to pressure adaptation TT_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1132 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Current N371 pressure control valve 6 lock-up clutch TT_CURRENT_N371_P_CTRL_6
- Service 22
DID 1029 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 1998 to 2023.
Current upper pressure point clutch 1 from current to pressure adaptation TT_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1131 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Current upper pressure point clutch 2 from current to pressure adaptation TT_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1133 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 1998 to 2023.
Driving strategy mountain factor TT_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR
- Service 22
DID 1018 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Driving strategy sport factor TT_PQ35_DRIVING_STRATEGY_SPORT_FACTOR
- Service 22
DID 1019 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Dynamic shift program TT_DYNAMIC_SHIFT
- Service 22
DID 2115 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for oxygen shift, cylinder 1 TT_EARLY_IGN_CNT_OXYGEN_1
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for oxygen shift, cylinder 2 TT_EARLY_IGN_CNT_OXYGEN_2
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for oxygen shift, cylinder 3 TT_EARLY_IGN_CNT_OXYGEN_3
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Early ignition counter for oxygen shift, cylinder 4 TT_EARLY_IGN_CNT_OXYGEN_4
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Engaged position side a gear selector 1-3 TT_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 1138 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side a gear selector 2-4 TT_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 1139 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side a gear selector 5 and neutral TT_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side a gear selector 6 and reverse TT_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side b gear selector 1-3 TT_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1144 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side b gear selector 2-4 TT_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1145 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side b gear selector 5 and neutral TT_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 1146 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engaged position side b gear selector 6 and reverse TT_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 1147 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Engine specified torque during transmission intervention TT_ENG_SPEC_TQ_DURING
- Service 22
DID 2110 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Fast fill time, clutch a TT_FAST_FILL_TIME_CLU
- Service 22
DID 7086 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 1998 to 2023.
Fast fill time, clutch b TT_FAST_FILL_TIME_CLU_B
- Service 22
DID 708A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 1998 to 2023.
Fast fill time, clutch c TT_FAST_FILL_TIME_CLU_C
- Service 22
DID 708E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 1998 to 2023.
Fast fill time, clutch d TT_FAST_FILL_TIME_CLU_D
- Service 22
DID 7092 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 1998 to 2023.
Fast fill time, clutch e TT_FAST_FILL_TIME_CLU_E
- Service 22
DID 7096 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 1998 to 2023.
Fill pressure, clutch a TT_FILL_P_CLU
- Service 22
DID 7084 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 1998 to 2023.
Fill pressure, clutch b TT_FILL_P_CLU_B
- Service 22
DID 7088 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 1998 to 2023.
Fill pressure, clutch c TT_FILL_P_CLU_C
- Service 22
DID 708C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 1998 to 2023.
Fill pressure, clutch d TT_FILL_P_CLU_D
- Service 22
DID 7090 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 1998 to 2023.
Fill pressure, clutch e TT_FILL_P_CLU_E
- Service 22
DID 7094 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 1998 to 2023.
Gear TT_GEAR_V2
- Service 22
DID 14CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Gear selector synchronous position G1 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1
- Service 22
DID 1179 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position G2 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2
- Service 22
DID 117A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position G3 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3
- Service 22
DID 117B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position G4 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4
- Service 22
DID 117C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position G5 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5
- Service 22
DID 117D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position G6 TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6
- Service 22
DID 117E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Gear selector synchronous position, reverse TT_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R
- Service 22
DID 117F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 1998 to 2023.
Input shaft 1 TT_MQB_INPUT_SHAFT_1
- Service 22
DID 380C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Input shaft 2 TT_MQB_INPUT_SHAFT_2
- Service 22
DID 380D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Launch control counter, clutch 1 TT_LAUNCH_CTRL_CNT_CLU_1
- Service 22
DID 38C0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Load shift flaps, actual value TT_LOAD_SHIFT_FLAPS_ACT
- Service 22
DID 295C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Load shift flaps, specified value TT_LOAD_SHIFT_FLAPS_SPEC
- Service 22
DID 295D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Lower adapted coupling point clutch 1 from kiss point adaptation TT_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT
- Service 22
DID 388D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 1998 to 2023.
Lower adapted coupling point clutch 2 from kiss point adaptation TT_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT
- Service 22
DID 388E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 1998 to 2023.
Mileage of oxidation catalytic converter TT_MILEAGE_OXIDATION
- Service 22
DID 51A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 1998 to 2023.
Mileage of SCR catalytic converter TT_MILEAGE_SCR
- Service 22
DID 519E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 1998 to 2023.
Neutral position gear selector 1-3 TT_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3
- Service 22
DID 1140 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Neutral position gear selector 2-4 TT_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4
- Service 22
DID 1141 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Neutral position gear selector 5 and neutral TT_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N
- Service 22
DID 1142 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Neutral position gear selector 6 and reverse TT_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R
- Service 22
DID 1143 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Nominal pressure clutch 2 TT_NOMINAL_P_CLU_2
- Service 22
DID 125D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 1998 to 2023.
Output shaft 1 TT_MQB_OUTPUT_SHAFT_1
- Service 22
DID 380E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Output shaft 2 TT_MQB_OUTPUT_SHAFT_2
- Service 22
DID 380F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1998 to 2023.
Powertrain overall gear ratio TT_POWERTRAIN_OVERALL
- Service 22
DID 11DF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Number
In testing for 1998 to 2023.
Pressure_clutch_1 TT_P_CLU_1
- Service 22
DID 1260 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Pressure_clutch_2 TT_P_CLU_2
- Service 22
DID 1261 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1998 to 2023.
Road resistance TT_PQ35_ROAD_RESISTANCE
- Service 22
DID 1017 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -31 to 31.894 %
- Unit
- %
In testing for 1998 to 2023.
Selected gear TT_SELECTED_GEAR
- Service 22
DID 7050 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253 °C
- Unit
- °C
In testing for 1998 to 2023.
Shift process, selected gear TT_SHIFT_PROCCESS
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Shift process, target gear TT_SHIFT_PROCCESS_TGT
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Specified torque clutch 1 TT_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1
- Service 22
DID 382E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Specified torque clutch 1 - data TT_SPEC_TQ_CLU_1_DATA
- Service 22
DID 2142 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Specified torque clutch 2 TT_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2
- Service 22
DID 3838 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638 to 1638.35 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Specified torque clutch 2 - data TT_SPEC_TQ_CLU_2_DATA
- Service 22
DID 2143 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Synchronous position side a gear selector 1-3 TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 113C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side a gear selector 2-4 TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 113D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side a gear selector 5 and neutral TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side a gear selector 6 and reverse TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side b gear selector 1-3 TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1148 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side b gear selector 2-4 TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1149 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side b gear selector 5 and neutral TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 114A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Synchronous position side b gear selector 6 and reverse TT_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 114B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 1998 to 2023.
Time since shift TT_TIME_SINCE_SHIFT
- Service 22
DID 1033 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 1998 to 2023.
Torque converter amplification TT_TQ_CONV
- Service 22
DID 2130 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
In testing for 1998 to 2023.
Torque loss adaptation, A/C compressor + gear engaged TT_TQ_LOSS_ADPT_AC_COMP
- Service 22
DID 1222 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Torque loss adaptation, gear engaged TT_TQ_LOSS_ADPT_GEAR
- Service 22
DID 1224 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 1998 to 2023.
Transmission coolant valve, open TT_TRANS_CLT_VLV_OPEN
- Service 22
DID 3D74 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 1998 to 2023.
Transmission fluid temperature 2 TT_ATF_T_2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 38BF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1998 to 2023.
Transmission gear ratio TT_TRANS_GEAR_RAT
- Service 22
DID 0327 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1.28 to 1.27
- Unit
- Number
In testing for 1998 to 2023.
Upper adapted coupling point clutch 1 from microslip adaptation TT_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT
- Service 22
DID 388F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 1998 to 2023.
Upper adapted coupling point clutch 2 from microslip adaptation TT_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT
- Service 22
DID 3890 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 1998 to 2023.
Trips
Analysis, clutch 1 temperature time in range 1 TT_ANALYSIS_CLU_1_T_1
- Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 1 temperature time in range 2 TT_ANALYSIS_CLU_1_T_2
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 1 temperature time in range 3 TT_ANALYSIS_CLU_1_T_3
- Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 2 temperature time in range 0 TT_ANALYSIS_CLU_2_T_0
- Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 2 temperature time in range 1 TT_ANALYSIS_CLU_2_T_1
- Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 2 temperature time in range 2 TT_ANALYSIS_CLU_2_T_2
- Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Analysis, clutch 2 temperature time in range 3 TT_ANALYSIS_CLU_2_T_3
- Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Clutch 1 temperature time in range 0 TT_CLU_1_T_TIME_RANGE_0
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 1998 to 2023.
Distance to empty TT_DTE
Pelican can show this parameter as the fuel range.
- Service 22
DID 2294 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 1998 to 2014, 2016 to 2023. Not supported for 2015.
Drive cycles counter TT_MQB_TCM_DRIVE_CYCLES_COUNTER
- Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Driving time ecological TT_MQB_TCM_DRIVING_TIME_ECOLOGICAL
- Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Driving time manual TT_MQB_TCM_DRIVING_TIME_MANUAL
- Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Driving time sporty TT_MQB_TCM_DRIVING_TIME_SPORTY
- Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Ignition cycles TT_MQB_TCM_IGNITION_CYCLES
- Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 1998 to 2023.
Mixture variation in adapted part load range 1 TT_MIXTURE_VARIATION_1
- Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 1998 to 2023.
Odometer TT_ODO_7E0
Pelican can show this parameter as the odometer.
- Service 22
DID 108C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1998 to 2023.
Odometer TT_ODO_7E1_2
Pelican can show this parameter as the odometer.
- Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1998 to 2023.
Odometer (alternative) TT_ODO_2Confirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
7E0 - Every
5 s - Testing for 1998 to 2014, 2018 to 2023
Example reply from a 2017 Audi TT.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x016CAF = 93359 → 93,359 km
Confirmed for 2015 to 2017. In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013.
Odometer (dash) TT_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 2203 - Module
714 → 77E - Every
10 s - Testing for 1998 to 2014, 2018 to 2023
Example reply from a 2017 Audi TT.
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
0x016CAF = 93359 → 93,359 km
Confirmed for 2015 to 2017. In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013.
Odometer (TCM #1) TT_ODO_TCM_1
Pelican can show this parameter as the odometer.
- Service 22
DID 3841 - Module
7E1 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Odometer (TCM #2 high res) TT_ODO_TCM_2_HDConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 3887 - Module
7E1 - Every
1 s - Testing for 1998 to 2014, 2018 to 2023
Example reply from a 2017 Audi TT.
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
0x000E7A01 = 948737 → = 94,873.7 km
Confirmed for 2015 to 2017. In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013.
Odometer (TCM #2) TT_ODO_TCM_2
Pelican can show this parameter as the odometer.
- Service 22
DID 101A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1998 to 2010, 2012, 2014, 2018 to 2023. Not supported for 2011, 2013, 2015 to 2017.
Odometer at oxidation catalytic converter replacement TT_ODO_OXYDATION
- Service 22
DID 4F3F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1998 to 2023.
Odometer at SCR catalytic converter replacement TT_ODO_SCR_CATALYTIC
- Service 22
DID 4F41 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1998 to 2023.
Odometer with ECU installed TT_ODO_ECU_INSTALLED
- Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 m
- Unit
- m
In testing for 1998 to 2023.
Odometer, high resolution TT_ODO_HD
Pelican can show this parameter as the odometer.
- Service 22
DID 1160 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967.295 km
- Unit
- km
In testing for 1998 to 2023.
Odometer, mileage, HR TT_ODO_MILEAGE_HR
- Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 1998 to 2023.
Operating time, temperature range 1 TT_OP_TIME_T_RANGE_1
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Operating time, temperature range 2 TT_OP_TIME_T_RANGE_2
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Operating time, temperature range 3 TT_OP_TIME_T_RANGE_3
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Operating time, temperature range 4 TT_OP_TIME_T_RANGE_4
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Operating time, temperature range 5 TT_OP_TIME_T_RANGE_5
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Operating time, temperature range 6 TT_OP_TIME_T_RANGE_6
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 1998 to 2023.
Remaining distance until reducing agent deficiency TT_REMAINING_DIST_UNTIL
- Service 22
DID 29B1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 214748364 km
- Unit
- km
In testing for 1998 to 2023.
Torque converter time in temperature range 1 TT_TQ_CONV_TIME_T_RANGE_1
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 2 TT_TQ_CONV_TIME_T_RANGE_2
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 3 TT_TQ_CONV_TIME_T_RANGE_3
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 4 TT_TQ_CONV_TIME_T_RANGE_4
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 5 TT_TQ_CONV_TIME_T_RANGE_5
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 6 TT_TQ_CONV_TIME_T_RANGE_6
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 143 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 7 TT_TQ_CONV_TIME_T_RANGE_7
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 144 to 167 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.
Torque converter time in temperature range 8 TT_TQ_CONV_TIME_T_RANGE_8
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 168 to 191 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1998 to 2023.