Audi SQ8

Parameters

The Audi SQ8 has 80 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Range remaining SQ8_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x0064 = 100 → 100 mi

Confirmed for 2021. In testing for 2020, 2022 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

12V battery capacity SQ8_12V_BAT_CAP

  • Service 22DID 2A06
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2020 to 2026.

Battery internal resistance, raw SQ8_BAT_INTERNAL_RES_RAW

  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val5
Range
0 to 51
Unit
Raw value

In testing for 2020 to 2026.

Control module voltage SQ8_VPWR

  • Service 22DID F442
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2020 to 2026.

Estimated reserve range SQ8_RANGE_EST_CAN

  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Generator voltage, actual SQ8_GEN_V_ACT

  • Service 22DID 4F00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2020 to 2026.

HV battery energy content SQ8_HVBAT_E_CONTENTConfirmed

Energy stored in the high voltage battery

  • Service 22DID 2AB8
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 16 to 31 of the reply, 16 bits.

Formula
val×251000
Range
0 to 1638.37 kWh
Unit
kWh

0x0000 = 0 → 0×251000 = 0 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

HV battery maximum energy, raw count SQ8_HVBAT_E_MAX_RAWConfirmed

  • Service 22DID 2AB2
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

0x0519 = 1305 → 1,305

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Maximum charge current SQ8_MAX_CHA_CUR_2

  • Service 22DID 1159
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2020 to 2026.

Maximum discharge current SQ8_MAX_DCHA_CUR_2

  • Service 22DID 1158
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3200 to 3200 A
Unit
A

In testing for 2020 to 2026.

Start/stop battery charge SQ8_SSB_AHConfirmed

  • Service 22DID 2A0F
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

0x2C = 44 → 44 Ah

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Start/stop battery current SQ8_SSB_C

  • Service 22DID 2A09
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
val1000
Range
0 to 100 A
Unit
A

In testing for 2020 to 2026.

Start/stop battery resistance SQ8_SSB_RConfirmed

  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 7 of the reply, 8 bits.

Formula
val×210
Range
0 to 51 mΩ
Unit
mΩ

0x12 = 18 → 18×210 = 3.6 mΩ

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Start/stop battery sensor temperature SQ8_SSB_TConfirmed

  • Service 22DID 2A0B
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

0x49 = 73 → 73−40 = 33 °C

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Start/stop battery state of charge SQ8_SSB_SOCConfirmed

  • Service 22DID 2A0C
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

0x47 = 71 → 71 %

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Start/stop battery target voltage SQ8_SSB_VT

  • Service 22DID 2A00
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+10.6
Range
0 to 36.1 V
Unit
V

In testing for 2020 to 2026.

Start/stop battery voltage SQ8_SSB_VConfirmed

  • Service 22DID 2A07
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000+4
Range
4 to 69.53 V
Unit
V

0x2457 = 9303 → 93031000+4 = 13.303 V

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Start/stop battery voltage, at rest SQ8_SSB_V_RESTConfirmed

  • Service 22DID 2A10
  • Module710 → 77A
  • Every1 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 7 of the reply, 8 bits.

Formula
val10+9
Range
9 to 34.5 V
Unit
V

0x22 = 34 → 3410+9 = 12.4 V

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Internal

Average battery consumption SQ8_HVBAT_CSMP_AVG_INT

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2020 to 2026.

Estimated electric power reserve SQ8_RANGE_EST_INT

  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Climate

A/c compressor torque, requested SQ8_AC_COMP_T

  • Service 22DID 1002
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2020 to 2026.

Ambient temperature SQ8_AAT_V2

  • Service 22DID 1004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val128
Range
-255 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Clocks

Time since engine start SQ8_RUNTM

How long it's been since the engine started.

  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2020 to 2026.

Control

Brake SQ8_BRAKE_PRESSED

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Brake booster pressure SQ8_BRAKE_BST_P

  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 bar
Unit
bar

In testing for 2020 to 2026.

Brake pressure reading valid? SQ8_BRAKE_PRESSED_VALID

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Pressure in brake servo unit SQ8_P_BRAKE_SERVO_UNIT

  • Service 22DID 2005
  • Module713 → 77D
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val16
Range
-2048 to 2047
Unit
Raw value

In testing for 2020 to 2026.

Steering wheel angle SQ8_STEER_ANGLEConfirmed

Positive is rotated to the left, negative is rotated to the right.

  • Service 22DID 2B29
  • Module713 → 77D
  • Every100 ms
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val1000
Range
-32.768 to 32.767 rad
Unit
rad

0xFC5C = -932 → -9321000 = -0.932 rad

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Pedals

Accelerator pedal position sensor 1 SQ8_APP_POS1

  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2020 to 2026.

Accelerator pedal position sensor 2 SQ8_APP_POS2

  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65 V
Unit
V

In testing for 2020 to 2026.

DTCs

Distance traveled since dtcs cleared SQ8_CLR_DIST

  • Service 22DID F431
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Distance traveled while mil was activated SQ8_MIL_DIST

  • Service 22DID F421
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2020 to 2026.

Number of warm-ups since dtcs cleared SQ8_WARM_UPS

  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Engine

Break pressure SQ8_BREAK_P

  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val×15299910000000−42.503
Range
-543 to 458 bar
Unit
bar

In testing for 2020 to 2026.

Bze_q_elad SQ8_BZE_Q_ELAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2020 to 2026.

Bze_q_lad SQ8_BZE_Q_LAD

  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val10
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2020 to 2026.

Control module temperature SQ8_ECU_TEMP

  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-500 to 500 °C
Unit
°C

In testing for 2020 to 2026.

Elector motor 1 torque SQ8_EM_TORQ_1

  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2020 to 2026.

Elector motor 2 torque SQ8_EM_TORQ_2

  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2020 to 2026.

Elector motor 3 torque SQ8_EM_TORQ_3

  • Service 22DID 1155
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val32
Range
-1000 to 1000 N·m
Unit
N·m

In testing for 2020 to 2026.

Electric motor 1 rpm SQ8_EM_RPM_1

  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-100 to 100 rpm
Unit
rpm

In testing for 2020 to 2026.

Electric motor 2 rpm SQ8_EM_RPM_2

  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val2
Range
-100 to 100 rpm
Unit
rpm

In testing for 2020 to 2026.

Energy balance of last driving cycle SQ8_ENERGY_BALANCE_LAST

  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val100
Range
-327 to 327 Ah
Unit
Ah

In testing for 2020 to 2026.

Engine oil temperature SQ8_EOT_V2

Scaling is unknown, needs further validation.

  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2026.

Generator current SQ8_GEN_CURRENT

  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 A
Unit
A

In testing for 2020 to 2026.

Hill descent control SQ8_HDC_ACTIVE

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Hill descent control, incline SQ8_HDC_INCLINE

  • Service 22DID 1808
  • Module713 → 77D
  • Every2 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2020 to 2026.

Oil level SQ8_OIL_LEVEL

  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2020 to 2026.

Overall energy balance SQ8_OVERALL_ENERGY

  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val×2120
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2020 to 2026.

Fluids

Automatic transmission fluid temperature SQ8_ATF_T

  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Oil level warning threshold SQ8_OIL_LEVEL_WARN

  • Service 22DID 11BD
  • Module7E0 → 7E8
  • Every15 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2020 to 2026.

Oil level, critical SQ8_OIL_CRIT

  • Service 22DID 11BB
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val2500
Range
0 to 26.2 cm
Unit
cm

In testing for 2020 to 2026.

Lights

Brake light SQ8_BRAKE_LIGHT_ON

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2026.

Brake light reading valid? SQ8_BRAKE_LIGHT_ON_VALID

  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2020 to 2026.

Movement

Front left wheel speed SQ8_TIRE_FL_SPD_V2

  • Service 22DID 2B1B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2020 to 2026.

Front left wheel speed SQ8_TIRE_FL_SPD_V3

  • Service 22DID 1002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Front right wheel speed SQ8_TIRE_FR_SPD_V2

  • Service 22DID 2B1C
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2020 to 2026.

Front right wheel speed SQ8_TIRE_FR_SPD_V3

  • Service 22DID 1001
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear left wheel speed SQ8_TIRE_RL_SPD_V2

  • Service 22DID 2B1D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear left wheel speed SQ8_TIRE_RL_SPD_V3

  • Service 22DID 1004
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear right wheel speed SQ8_TIRE_RR_SPD_V2

  • Service 22DID 2B1E
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 1000 km/h
Unit
km/h

In testing for 2020 to 2026.

Rear right wheel speed SQ8_TIRE_RR_SPD_V3

  • Service 22DID 1003
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Vehicle speed SQ8_VSS

Current vehicle speed.

Pelican can show this parameter as the speed.

  • Service 22DID F40D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2026.

Vehicle speed, directional SQ8_VSS_DIR

  • Service 22DID 115B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val64
Range
-512 to 511 km/h
Unit
km/h

In testing for 2020 to 2026.

Stats

Driving time, eco SQ8_DRIVE_TIME_ECO

Value may be wrong, needs more validation. Proportion of time spent driving in eco mode

  • Service 22DID 0303
  • Module7E1 → 7E9
  • Every300 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Driving time, manual SQ8_DRIVE_TIME_MANUAL

Value may be wrong, needs more validation. Proportion of time spent driving in manual mode

  • Service 22DID 0305
  • Module7E1 → 7E9
  • Every300 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Driving time, sport SQ8_DRIVE_TIME_SPORT

Value may be wrong, needs more validation. Proportion of time spent driving in sport mode

  • Service 22DID 0304
  • Module7E1 → 7E9
  • Every300 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val2.5
Range
0 to 100 %
Unit
%

In testing for 2020 to 2026.

Total drive time SQ8_DRIVE_TIME

  • Service 22DID 0302
  • Module7E1 → 7E9
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val4
Range
0 to 16383 h
Unit
h

In testing for 2020 to 2026.

Tires

Entire energy throughput SQ8_ENTIRE_ENERGY

  • Service 22DID 2A18
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
val10
Range
-838860 to 838860 Ah
Unit
Ah

In testing for 2020 to 2026.

Steering wheel temperature SQ8_STEER_WHL_T

  • Service 22DID 5505
  • Module710 → 77A
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2026.

Transmission

Current gear SQ8_GEAR

The automatic transmission gear.

  • Service 22DID 210F
  • Module7E1 → 7E9
  • Every2 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
11First gear
22Second gear
33Third gear
44Fourth gear
55Fifth gear
66Sixth gear
77Seventh gear

In testing for 2020 to 2026.

Trips

Average consumption, category 0 SQ8_AVG_CSMP_CAT0Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 1 SQ8_AVG_CSMP_CAT1Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 16 to 31 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 2 SQ8_AVG_CSMP_CAT2Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 32 to 47 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 3 SQ8_AVG_CSMP_CAT3Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 48 to 63 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 4 SQ8_AVG_CSMP_CAT4Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 64 to 79 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 5 SQ8_AVG_CSMP_CAT5Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 80 to 95 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x00D2 = 210 → 21010 = 21 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Average consumption, category 6 SQ8_AVG_CSMP_CAT6Confirmed

  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 96 to 111 of the reply, 16 bits.

Formula
val10
Range
0 to 6553 kWh
Unit
kWh

0x0000 = 0 → 010 = 0 kWh

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Odometer SQ8_ODO_V3

Pelican can show this parameter as the odometer.

  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4000000000 km
Unit
km

In testing for 2020 to 2026.

Odometer, high resolution SQ8_ODO_HD

Pelican can show this parameter as the odometer.

  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val1000
Range
0 to 4294967.295 km
Unit
km

In testing for 2020 to 2026.

Range remaining SQ8_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2020, 2022 to 2026

Example reply from a 2021 Audi SQ8.

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mi
Unit
mi

0x0064 = 100 → 100 mi

Confirmed for 2021. In testing for 2020, 2022 to 2026.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.