Parameters
The Audi RS 5 has 1,258 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
12V battery adapted capacity RS5_AUX_BAT_CAP
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 Ah
- Unit
- Ah
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery aging by capacity RS5_AUX_BAT_AGE_CAP
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery aging by power RS5_AUX_BAT_AGE_POW
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery capacity RS5_12V_BAT_CAP
- Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2010 to 2026.
12V battery current RS5_AUX_BAT_C
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 47 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -1000000 to 1000000 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery sensor temperature RS5_AUX_BAT_T_S
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery soc RS5_AUX_BAT_SOC
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery temperature RS5_AUX_BAT_T
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery total charge RS5_AUX_BAT_CHRG_TOT
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery total discharge RS5_AUX_BAT_DSCH_TOT
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
12V battery voltage RS5_AUX_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 69 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal, sensor 1 voltage RS5_ACCEL_PEDAL_SENS_1_V
- Service 22
DID 102A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2010 to 2026.
Accelerator pedal, sensor 2 voltage RS5_ACCEL_PEDAL_SENS_2_V
- Service 22
DID 102B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2010 to 2026.
Aux. hydraulic pump voltage RS5_AUX_HYDRAULIC_PMP_V
- Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2010 to 2026.
Battery acid stratification RS5_BAT_ACID
- Service 22
DID 2A1D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2559 %
- Unit
- %
In testing for 2010 to 2026.
Battery charge level RS5_BAT_SOCConfirmed
- Service 22
DID 2A0C - Module
710 → 77A - Every
10 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x48 = 72 → 72 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery condition for display RS5_BAT_COND_DISPLAY
- Service 22
DID 2A0D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550 %
- Unit
- %
In testing for 2010 to 2026.
Battery current RS5_BAT_IConfirmed
- Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -2147483.648 to 2147483 A
- Unit
- A
0x00000209 = 521 → = 0.521 A
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery current filtered RS5_BAT_CURRENT_FILTERED
- Service 22
DID 2A08 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- -3000 to 13777 A
- Unit
- A
In testing for 2010 to 2026.
Battery internal resistance RS5_BAT_INT_RConfirmed
- Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
0x15 = 21 → = 4.2
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery internal resistance, raw RS5_BAT_INTERNAL_RES_RAW
- Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51
- Unit
- Raw value
In testing for 2010 to 2026.
Battery power reduction active RS5_BMS_PWR_REDUCE_ACT
- Service 22
DID 1E0A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Battery sensor temperature RS5_MQB_BAT_SEN_T
- Service 22
DID 2A0A - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Battery temperature RS5_BAT_TConfirmed
- Service 22
DID 2A0B - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x2B = 43 → = 3 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery total charge RS5_MQB_BAT_TOT_CHG
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Battery total discharge RS5_MQB_BAT_TOT_DIS
- Service 22
DID 2A61 - Module
710 → 77A - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Battery voltage RS5_BAT_V_2A07Confirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 2A07 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 4 to 69.535 V
- Unit
- V
0x2239 = 8761 → = 12.761 V
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery voltage RS5_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 2010 to 2026.
Battery voltage at rest RS5_BAT_V_AT_RESTConfirmed
- Service 22
DID 2A10 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 9 to 34.5 V
- Unit
- V
0x22 = 34 → = 12.4 V
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Battery voltage variant RS5_PQ35_BAT_V_2
- Service 22
DID 105E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2010 to 2026.
Boost pressure RS5_PQ35_CHG_P
- Service 22
DID 1057 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2010 to 2026.
Bypass valve high pressure turbine inlet, raw voltage RS5_BYPASS_VLV_HIGH_P_V
- Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2010 to 2026.
Cell state of charge max, index RS5_BMS_CELL_SOC_MAX_IDX
- Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell state of charge max, value RS5_BMS_CELL_SOC_MAX
- Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell state of charge min, index RS5_BMS_CELL_SOC_MIN_IDX
- Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell state of charge min, value RS5_BMS_CELL_SOC_MIN
- Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage max, index RS5_BMS_CELL_V_MAX_IDX
- Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage max, value RS5_BMS_CELL_V_MAX
- Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.5535 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage min, index RS5_BMS_CELL_V_MIN_IDX
- Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage min, value RS5_BMS_CELL_V_MIN
- Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6.5535 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Cell voltage sum RS5_BMS_CELL_V_SUM
- Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value RS5_CHG_AIR_COOLER_INLET_P_1_1
- Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2010 to 2026.
Charge air pressure RS5_PQ35_CHG_AIR_P
- Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge air pressure actuator position digit.value RS5_CHG_AIR_P_ACTUATOR_7E0
- Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Charge air pressure actuator, acknowledgment RS5_CHG_AIR_P_ACTUATOR
- Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Charge air pressure, actual value RS5_CHG_AIR_P_ACT
- Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2010 to 2026.
Charge air pressure, specified value RS5_CHG_AIR_P_SPEC
- Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Charge air pressure: actual RS5_PQ35_CHARGE_AIR_P_ACTUAL
- Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2010 to 2026.
Charge air pressure: specified RS5_PQ35_CHARGE_AIR_P_SPECIFIED
- Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2010 to 2026.
Charge air temp at the turbocharger outlet, calculated RS5_MQB_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED
- Service 22
DID 1798 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Charge limit overcharge protection RS5_PQ35_CHG_LIM_OVER
- Service 22
DID 1356 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Charge pressure actuator, actual position RS5_CHG_P_ACTUATOR_ACT
- Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure actuator, adaptation for lower stop RS5_CHG_P_ACTUATOR_ADPT
- Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Charge pressure actuator, adaptation for upper stop RS5_CHG_P_ACTUATOR_ADPT_HI
- Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Charge pressure actuator, maximum sensor voltage RS5_CHG_P_ACTUATOR_MAX_V
- Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 mV
- Unit
- mV
In testing for 2010 to 2026.
Charge pressure actuator, specified position RS5_CHG_P_ACTUATOR_SPEC
- Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure actuator, specified value RS5_CHG_P_ACTUATOR_SPEC_7E0
- Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure before throttle valve, calculated actual value RS5_CHG_P_BEFORE_ACT
- Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 2010 to 2026.
Charge pressure control adaptation higher than max. threshold RS5_CHG_P_CTRL_ADPT_MAX
- Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control adaptation lower than min. threshold RS5_CHG_P_CTRL_ADPT_LO_MIN
- Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control specified value RS5_CHG_P_CTRL_SPEC
- Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control valve activation pulse duty factor RS5_CHG_P_CTRL_VLV
- Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control valve position, actual value RS5_CHG_P_CTRL_VLV_POS_ACT
- Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control valve position, target value RS5_CHG_P_CTRL_VLV_POS_TGT
- Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Charge pressure control valve sensor voltage RS5_CHG_P_CTRL_VLV_SENS_V
- Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2010 to 2026.
Charge pressure control valve voltage, position closed RS5_CHG_P_CTRL_VLV_V_POS
- Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2010 to 2026.
Charge pressure control valve voltage, position opened RS5_CHG_P_CTRL_VLV_V_POS_OPENED
- Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2010 to 2026.
Charge pressure regulator, lower threshold adaptation RS5_CHG_P_REGULATOR_LO
- Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Charge pressure regulator, upper threshold adaptation RS5_CHG_P_REGULATOR_HI
- Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Charge pressure sensor, unconditioned voltage RS5_CHG_P_SENS_V
- Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Control module voltage RS5_VPWRConfirmed
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID F442 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
0x2FE4 = 12260 → = 12.26 V
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Cylinder charge specified value RS5_CYL_CHG_SPEC
- Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2010 to 2026.
Cylinder charge, actual value RS5_CYL_CHG_ACT
- Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2010 to 2026.
DC-DC converter, current RS5_DCDC_I
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
DC-DC converter, low voltage RS5_DCDC_V_LOW
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
DC-DC converter, reserved current RS5_DCDC_I_RSV
- Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- -511 to 65024 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
ECall battery charge level RS5_ECALL_SOC
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
ECall battery status RS5_ECALL_STATUS
- Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State |
|---|---|
1 | CRITICAL |
2 | NORMAL |
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electric motor battery energy RS5_EM_HVBAT_E_INFO
- Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Estimated reserve range RS5_RANGE_EST_CANConfirmed
- Service 22
DID 2AB5 - Module
710 → 77A - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x07FF = 2047 → 2,047 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Generator target voltage RS5_MQB_GEN_TRG_VConfirmed
- Service 22
DID 2A00 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 10.6 to 36.1 V
- Unit
- V
0x18 = 24 → = 13 V
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Generator voltage, actual RS5_GEN_V_ACT
- Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2010 to 2026.
High pressure turbocharger actuator, activation RS5_HIGH_P_TURBOCHARGER
- Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
High voltage battery energy information RS5_HIGH_V_EM_HVBAT
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2010 to 2026.
High voltage battery energy information RS5_HVBAT_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638 kWh
- Unit
- kWh
In testing for 2010 to 2026.
High voltage battery inlet temperature RS5_HVBAT_INLET_T
- Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2010 to 2026.
High voltage battery mode RS5_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7
- Service 22
DID 7448 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
High voltage battery outlet temperature RS5_HVBAT_OUTLET_T
- Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2010 to 2026.
High voltage battery temperature RS5_HVBAT_T
- Service 22
DID 2A0B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2010 to 2026.
HV battery coldest sensor RS5_HVBAT_T_MIN_NO
- Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery current RS5_HVBAT_CURRENT
- Service 22
DID 1E3D - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -200 to 200 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery energy content RS5_HVBAT_E_CONTENTConfirmed
Energy stored in the high voltage battery
- Service 22
DID 2AB8 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 1638.37 kWh
- Unit
- kWh
0x0000 = 0 → = 0 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
HV battery health RS5_HVBAT_SOH
- Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -1798.574 to 6524 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery highest cell RS5_HVBAT_CELL_V_MAX_NO
- Service 22
DID 1E33 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery lowest cell RS5_HVBAT_CELL_V_MIN_NO
- Service 22
DID 1E34 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery maximum energy, raw count RS5_HVBAT_E_MAX_RAWConfirmed
- Service 22
DID 2AB2 - Module
710 → 77A - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x0519 = 1305 → 1,305
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
HV battery state of charge RS5_BMS_SOC
- Service 22
DID 028C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery state of charge, hd RS5_BMS_SOC_HIRES
- Service 22
DID F45B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery temperature load RS5_HVBAT_T_LOAD
- Service 22
DID 1165 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
HV battery temperature, minimum RS5_BMS_T_MIN
- Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery temperature, minimum, cell number RS5_BMS_T_MIN_CELL
- Service 22
DID 1E0F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery total ampere hours of charge RS5_HVBAT_TOT_AH_CHRG
- Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 7818700 Ah
- Unit
- Ah
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery total ampere hours of discharge RS5_HVBAT_TOT_AH_DCHRG
- Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery total kilowatt hours of charge RS5_HVBAT_TOT_KWH_CHRG
- Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
- Range
- 0 to 500300 kWh
- Unit
- kWh
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
HV battery total kilowatt hours of discharge RS5_HVBAT_TOT_KWH_DCHRG
- Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -250199 to 250199 kWh
- Unit
- kWh
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Ignition angle current cylinder RS5_PQ35_IGN_ANG_CYL
- Service 22
DID 137A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 60 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Knock sensor voltage, cylinder 1 RS5_KNOCK_SENS_V_CYL_1
- Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor voltage, cylinder 3 RS5_KNOCK_SENS_V_CYL_3_7E0
- Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 319 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor voltage:, cylinder 2 RS5_KNOCK_SENS_V_CYL_2
- Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor voltage:, cylinder 3 RS5_KNOCK_SENS_V_CYL_3
- Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor voltage:, cylinder 5 RS5_KNOCK_SENS_V_CYL_5
- Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor voltage:, cylinder 6 RS5_KNOCK_SENS_V_CYL_6
- Service 22
DID 13FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensors average voltage bank 1, variant 2 RS5_KNOCK_SENSORS_AVG_V_1_2
- Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Maximum charge current RS5_MAX_CHA_CUR_2Confirmed
- Service 22
DID 1159 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
0x0000 = 0 → = 0 A
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Maximum charge voltage RS5_BMS_V_CHG_MAX
- Service 22
DID 5171 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Maximum discharge current RS5_MAX_DCHA_CUR_2
- Service 22
DID 1158 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Maximum dynamic charge current limit RS5_BMS_I_CHG_LIM_DYN
- Service 22
DID 1E1B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Maximum dynamic discharge current limit RS5_BMS_I_DCHG_LIM_DYN
- Service 22
DID 1E1C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Maximum predicted charge current limit RS5_BMS_I_CHG_LIM_PRED
- Service 22
DID 1E1D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Maximum predicted discharge current limit RS5_BMS_I_DCHG_LIM_PRED
- Service 22
DID 1E1E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 A
- Unit
- A
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Minimum discharge voltage RS5_BMS_V_DCHG_MIN
- Service 22
DID 5170 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Minimum dynamic charge voltage RS5_BMS_V_CHG_DYN_MIN
- Service 22
DID 5174 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Minimum dynamic discharge voltage RS5_BMS_V_DCHG_DYN_MIN
- Service 22
DID 5175 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Minimum predicted charge voltage RS5_BMS_V_CHG_PRED_MIN
- Service 22
DID 5172 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Minimum predicted discharge voltage RS5_BMS_V_DCHG_PRED_MIN
- Service 22
DID 5173 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Non-vehicle energy requirement RS5_NV_ENERGY_REQUIREMENT
- Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Service regeneration current duration RS5_PQ35_SRV_REGEN_DUR
- Service 22
DID 1164 - Module
7E0 → 7E8 - Every
30 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 715827 min
- Unit
- min
Temperature sensor for engine temperature management voltage RS5_T_SENS_ENG_T_V
- Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Turbocharger inlet pressure corrected value RS5_TURBOCHARGER_INLET_P
- Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Usable battery charge RS5_USE_BAT_CHGConfirmed
- Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 Ah
- Unit
- Ah
0x1E = 30 → 30 Ah
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Internal
Average battery consumption RS5_HVBAT_CSMP_AVG_INTConfirmed
- Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 A
- Unit
- A
0x19 = 25 → 25 A
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Estimated electric power reserve RS5_RANGE_EST_INTConfirmed
- Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Modules
Module 3, temperature 1 RS5_HVBAT_MOD3_T1
- Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Module 3, temperature 2 RS5_HVBAT_MOD3_T2
- Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Module 3, temperature 3 RS5_HVBAT_MOD3_T3
- Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Climate
A/C compressor power, actual RS5_AC_CMPR_PWR_ACT
- Service 22
DID 0800 - Module
746 → 7B0 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 W
- Unit
- W
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
A/C compressor torque, requested RS5_AC_COMP_TConfirmed
- Service 22
DID 1002 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
0x0000 = 0 → = 0 N·m
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
A/C refrigerant pressure, sensor 1 RS5_AC_REFRIG_P_SENS1
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 576.708 bar
- Unit
- bar
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
A/C refrigerant temperature, sensor 1 RS5_AC_REFRIG_T_SENS1
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
A/C refrigerant temperature, sensor 1 interior RS5_AC_REFRIG_T_SENS1_INT
- Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Air conditioning compressor power consumption RS5_PQ35_AC_COMP_PWR
- Service 22
DID 27D6 - Module
746 → 7B0 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 10.2 kW
- Unit
- kW
In testing for 2010 to 2026.
Air conditioning compressor shutdown requirement RS5_MQB_TCM_A_C_COMPRESSOR_SHUTDOWN_REQUIREMENT
- Service 22
DID 381A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Air conditioning compressor torque RS5_PQ35_AC_COMP_TRQ
- Service 22
DID 104B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Ambient air temperature RS5_AAT_7E0_7E0
- Service 22
DID F446 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Ambient temperature RS5_AAT_V2Confirmed
- Service 22
DID 1004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -255 to 255 °C
- Unit
- °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Barometric pressure RS5_BARO
- Service 22
DID F433 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Cabin humidity RS5_CABIN_HUMIDITY
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
CO2 content interior RS5_CABIN_CO2
- Service 22
DID 42DB - Module
746 → 7B0 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Outside humidity RS5_HVAC_OUTSIDE_HUM
- Service 22
DID 27C3 - Module
746 → 7B0 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Outside temperature RS5_AATConfirmed
- Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 100 °C
- Unit
- °C
0x004B = 75 → = 7.5 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Recirculation flap actual position RS5_MQB_RECIRC_FLAP_ACT
- Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Recirculation flap fresh air threshold RS5_MQB_RECIRC_FLAP_FRESH_THR
- Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Recirculation flap target position RS5_MQB_RECIRC_FLAP_TRG
- Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Recirculation flap threshold RS5_MQB_RECIRC_FLAP_THR
- Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Windshield temperature RS5_WINDSHIELD_T
- Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -38.8 to 108.08 °C
- Unit
- °C
In testing for 2010 to 2026.
Clocks
Time since engine start RS5_RUNTMConfirmed
How long it's been since the engine started.
- Service 22
DID F41F - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
0x0033 = 51 → 51 s
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Control
Absolute pedal position, drive RS5_APP_D
- Service 22
DID F449 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal release detection threshold voltage RS5_APP_REDUCE_V
- Service 22
DID 1029 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2010 to 2026.
Air gab vacuum sensor RS5_AIR_GAB_VACUUM_SNS
- Service 22
DID 1816 - Module
713 → 77D - Every
2 s - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 32767
- Unit
- Raw value
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Brake RS5_BRAKE_PRESSEDConfirmed
- Service 22
DID 0805 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b1 = 1 → 1
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Brake booster low pressure, actual RS5_BRAKE_BOOSTER_LOW_P_ACT
- Service 22
DID 1490 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.9937
- Unit
- Raw value
In testing for 2010 to 2026.
Brake booster pressure RS5_BRAKE_BOOSTER_P
- Service 22
DID 11CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559
- Unit
- Raw value
In testing for 2010 to 2026.
Brake booster pressure RS5_PQ35_BRAKE_BOOSTER_P
- Service 22
DID 2005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5434
- Unit
- Raw value
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Brake booster raw pressure RS5_BRAKE_BOOSTER_RAW_P
- Service 22
DID 11D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2026.
Brake disk drying RS5_BDD_ACTIVE
- Service 22
DID 180E - Module
713 → 77D - Every
2 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Brake disk drying, odometer at last activation RS5_BDD_ODO
- Service 22
DID 180E - Module
713 → 77D - Every
2 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Brake pedal position RS5_BRAKE_PEDAL_POS
- Service 22
DID 105D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Brake pressure RS5_BRAKE_P
- Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -543.8501 to 458.8288 bar
- Unit
- bar
In testing for 2010 to 2026.
Brake pressure RS5_BRAKE_P_7E0
- Service 22
DID 195D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Brake pressure RS5_MQB_TCM_BRAKE_P
- Service 22
DID 3803 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Brake pressure RS5_PQ35_BRAKE_P
- Service 22
DID 18D0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Brake pressure reading valid? RS5_BRAKE_PRESSED_VALIDConfirmed
- Service 22
DID 0805 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bit 5 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b0 = 0 → 0
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Brake pressure sensor RS5_BRAKE_P_SNS
- Service 22
DID 1816 - Module
713 → 77D - Every
2 s - Testing
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Brake system vacuum pump active RS5_BRAKE_SYSTEM_VACUUM
- Service 22
DID 395E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Downshift point adaptation voltage RS5_DOWNSHIFT_ADAPT_V
- Service 22
DID 1028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2010 to 2026.
Electronic differential lock: active RS5_EDL_ACTIVE
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electronic differential lock: front left brake temperature RS5_EDL_FR_L_BRAKE_T
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electronic differential lock: front right brake temperature RS5_EDL_FR_R_BRAKE_T
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electronic differential lock: rear left brake temperature RS5_EDL_RR_L_BRAKE_T
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electronic differential lock: rear right brake temperature RS5_EDL_RR_R_BRAKE_T
- Service 22
DID 180C - Module
713 → 77D - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -20 to 300 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Hydraulic brake booster: active RS5_HYD_BRAKE_BOOST_ACTIVE
- Service 22
DID 1810 - Module
713 → 77D - Every
2 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Pressure in brake servo unit RS5_P_BRAKE_SERVO_UNIT
- Service 22
DID 2005 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375
- Unit
- Raw value
In testing for 2010 to 2026.
Requested brake torque, auxiliary system RS5_REQ_BRAKE_TQ
- Service 22
DID 1610 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Steering wheel angle RS5_STEER_ANGLEConfirmed
Positive is rotated to the left, negative is rotated to the right.
- Service 22
DID 2B29 - Module
713 → 77D - Every
100 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 rad
- Unit
- rad
0x003E = 62 → = 0.062 rad
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Pedals
Accelerator pedal position sensor 1 RS5_APP_POS1
- Service 22
DID 2061 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Accelerator pedal position sensor 2 RS5_APP_POS2
- Service 22
DID 2062 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65 V
- Unit
- V
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Drivetrain
Driver torque requested #1 RS5_ENG_TRQ_REQ_1
- Service 22
DID 29D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Driver torque requested #2 RS5_ENG_TRQ_REQ_2
- Service 22
DID 4380 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2019.
Distance traveled since diagnostic trouble codes cleared RS5_CLR_DISTConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 22
DID F431 - Module
7E0 → 7E8 - Every
30 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x2B9E = 11166 → 11,166 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Distance traveled while mil was activated RS5_MIL_DISTConfirmed
- Service 22
DID F421 - Module
7E0 → 7E8 - Every
30 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0000 = 0 → 0 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Number of warm-ups since diagnostic trouble codes cleared RS5_WARM_UPSConfirmed
- Service 22
DID F430 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
ECU
Misfires, cylinder 2 RS5_MISFIRES__CYL__2Confirmed
- Service 22
DID 1152 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x249E = 9374 → 9,374
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Misfires, cylinder 4 RS5_MISFIRES__CYL__4Confirmed
- Service 22
DID 1151 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x27EA = 10218 → 10,218
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Torque converter slip RS5_TORQUE_CONVERTER_SLIP_TCM
- Service 22
DID 2131 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Engine
A/C clutch RS5_CLIMATE_A_C_CLCH
- Service 22
DID 482B - Module
746 → 7B0 - Every
2 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
A/C compressor load RS5_CLIMATE_A_C_COMP_LOAD
- Service 22
DID 2604 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25.5 N·m
- Unit
- N·m
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
A/C compressor torque RS5_A_C_COMPRESSOR_TORQUE
- Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
A/C refrigerant pressure RS5_A_C_REFRIGERANT_PRES
- Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2010 to 2026.
Adaptation of loss torque RS5_ADPT_LOSS_TQ
- Service 22
DID 2929 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Adaptation of throttle valve RS5_ADPT_THROTTLE_VLV
- Service 22
DID 292B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder1 fast diagnosis RS5_ADPT_VAL_CYL1_FAST
- Service 22
DID 3F45 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder1 slow diagnosis RS5_ADPT_VAL_CYL1_SLOW
- Service 22
DID 3F41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder2 fast diagnosis RS5_ADPT_VAL_CYL2_FAST
- Service 22
DID 3F48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder2 slow diagnosis RS5_ADPT_VAL_CYL2_SLOW
- Service 22
DID 3F44 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder3 fast diagnosis RS5_ADPT_VAL_CYL3_FAST
- Service 22
DID 3F46 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder3 slow diagnosis RS5_ADPT_VAL_CYL3_SLOW
- Service 22
DID 3F42 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder4 fast diagnosis RS5_ADPT_VAL_CYL4_FAST
- Service 22
DID 3F47 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptation val.cylinder4 slow diagnosis RS5_ADPT_VAL_CYL4_SLOW
- Service 22
DID 3F43 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.53
- Unit
- Number
In testing for 2010 to 2026.
Adaptive mode RS5_ADAPTIVE_MODE
- Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Air conditioning compressor pressure, linear raw value RS5_AC_COMP_P_LINEAR_RAW
- Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2010 to 2026.
Air conditioning compressor refrigerant pressure RS5_AC_COMP_REFRIGERANT_P
- Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2010 to 2026.
Air conditioning compressor torque RS5_AC_COMP_TQ
- Service 22
DID 2017 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Air conditioning compressor torque request RS5_AC_COMP_TQ_REQ
- Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Air conditioning refrigerant pressure RS5_AC_REFRIGERANT_P
- Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2010 to 2026.
Air filling RS5_AIR_FILLING
- Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Air leakage RS5_AIR_LEAKAGE
- Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Air mass meter 1 RS5_MQB_AIR_MASS_1
- Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2010 to 2026.
Air mass, actual value, mg/stroke RS5_AIR_MASS_ACT_MG
- Service 22
DID 29D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Air mass, specified value RS5_AIR_MASS_SPEC
- Service 22
DID 104C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2026.
Air pollution level RS5_CLIMATE_AIR_POLUTION_LVL
- Service 22
DID 26ED - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -12.8 to 12.7
- Unit
- Number
In testing for 2010 to 2026.
Ambient air pressure RS5_AMBIENT_AIR_P
- Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2555.8649
- Unit
- Raw value
In testing for 2010 to 2026.
Ambient air temperature RS5_DASH_AMBIENT_AIR_TConfirmed
- Service 22
DID 1014 - Module
714 → 77E - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
0x70 = 112 → = 6 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Ambient air temperature, v1 RS5_AAT_V1
- Service 22
DID 14F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2010 to 2026.
Ambient temperature RS5_AAT_7E0
- Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2010 to 2026.
Ambient temperature RS5_AAT_7E0_2
- Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Analysis, clutch 1, maximum temperature RS5_ANALYSIS_CLU_1_MAX_T
- Service 22
DID 1064 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Analysis, clutch 2, maximum temperature RS5_ANALYSIS_CLU_2_MAX_T
- Service 22
DID 1079 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Automatic engine starts counter RS5_AUTOMATIC_ENG_STARTS
- Service 22
DID 2999 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Automatic transmission fluid temperature, lifetime max RS5_ATF_MAX
- Service 22
DID 704F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2026.
Aux. hydraulic pump internal temperature RS5_AUX_HYDRAULIC_PMP_T
- Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Aux. hydraulic pump, current RS5_AUX_HYDRAULIC_PMP
- Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 A
- Unit
- A
In testing for 2010 to 2026.
Average ignition timing angle delay adjustment RS5_AVG_IGN_TIM_ANG
- Service 22
DID 2949 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Avg. injection time RS5_AVG_INJ_TIME
- Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1717986 ms
- Unit
- ms
In testing for 2010 to 2026.
Avg. injection time RS5_AVG_INJ_TIME_7E0
- Service 22
DID 2003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25 ms
- Unit
- ms
In testing for 2010 to 2026.
Basic correction factor:, cylinder 1, filtered RS5_BASIC_CORR_FACTOR_1
- Service 22
DID 171A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2010 to 2026.
Basic correction factor:, cylinder 2, filtered RS5_BASIC_CORR_FACTOR_2
- Service 22
DID 171D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2010 to 2026.
Basic correction factor:, cylinder 3, filtered RS5_BASIC_CORR_FACTOR_3
- Service 22
DID 171B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2010 to 2026.
Basic correction factor:, cylinder 4, filtered RS5_BASIC_CORR_FACTOR_4
- Service 22
DID 171C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.999
- Unit
- Number
In testing for 2010 to 2026.
Battery module controller temperature, 3 RS5_BMS_BMCE_T3
- Service 22
DID 180E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Boost press before throttle: calculated actual value RS5_PQ35_BOOST_P_BEFORE_THROTTLE_CALCULATED_ACT
- Service 22
DID 181A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -81920000 to 81917500
- Unit
- Raw value
In testing for 2010 to 2026.
Boost pressure actuator, commanded duty RS5_BOOST_P_ACTUATOR_CMD
- Service 22
DID 16EE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.993 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Boost pressure commanded RS5_PQ35_BOOST_P_CMD
- Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Boost pressure, actual RS5_BOOST_P_ACT
- Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Boost pressure, actual RS5_BOOST_P_ACT_7E0
- Service 22
DID 111E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5242
- Unit
- Raw value
In testing for 2010 to 2026.
Boost pressure, target RS5_BOOST_P_TGT
- Service 22
DID 1118 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2550
- Unit
- Raw value
In testing for 2010 to 2026.
Boost regulation duty, commanded value RS5_BOOST_REGULATION_CMD
- Service 22
DID 1219 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Boost regulator feedback RS5_BOOST_REGULATOR_FEEDBACK
- Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Bypass valve high pressure turbine inlet, activation RS5_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Bypass valve high pressure turbine inlet, actual value RS5_BYPASS_VLV_HIGH_P_ACT
- Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Bypass valve high pressure turbine inlet, offset closed RS5_BYPASS_VLV_HIGH_P
- Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Bypass valve high pressure turbine inlet, offset open RS5_BYPASS_VLV_HIGH_P_TURBINE
- Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Bypass valve high pressure turbine inlet, target value RS5_BYPASS_VLV_HIGH_P_TGT
- Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -400 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Bze_q_elad RS5_BZE_Q_ELAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Bze_q_lad RS5_BZE_Q_LAD
- Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Cabin temperature RS5_CABIN_TConfirmed
- Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0084 = 132 → = 13.2 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Cabin temperature RS5_IAT
- Service 22
DID 2613 - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Calculated oil temperature RS5_PQ35_CALCULATED_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 20A1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Camshaft adaptation exhaust bank 1, phase position RS5_CAM_ADPT_EXH_BANK_1_PHASE
- Service 22
DID 2023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adaptation intake bank 1, phase position RS5_CAM_ADPT_INT_BANK_1_PHASE
- Service 22
DID 2021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adaptation intake, phase position RS5_CAM_ADPT_INT_PHASE
- Service 22
DID 1093 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720 to 719 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adaptation, counter due to knock RS5_CAM_ADPT_CNT_KNOCK
- Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Camshaft adaptation, exhaust bank 1, phase position RS5_CAM_ADPT_EXH_BANK_1
- Service 22
DID 1128 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adaptation, intake bank 1, phase position RS5_CAM_ADPT_INT_BANK_1
- Service 22
DID 1125 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adaptation, intake deviation RS5_CAM_ADPT_INT_DEV
- Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -256 to 255.9921 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment intake bank 1, activation % RS5_CAM_ADJ_INT_BANK_1
- Service 22
DID 2930 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Camshaft adjustment intake test bank 1 RS5_CAM_ADJ_INT_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Camshaft adjustment outlet test bank 1 RS5_CAM_ADJ_OUTLET_TEST_1
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Camshaft adjustment, exhaust bank 1, actual value RS5_CAM_ADJ_EXH_BANK_1_ACT
- Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, exhaust bank 1, specified value RS5_CAM_ADJ_EXH_BANK_1_SPEC
- Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, exhaust bank 2, actual value RS5_CAM_ADJ_EXH_BANK_2_ACT
- Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, exhaust bank 2, specified value RS5_CAM_ADJ_EXH_BANK_2_SPEC
- Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262 to 262 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, exhaust, actual value RS5_CAM_ADJ_EXH_ACT
- Service 22
DID 201A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, exhaust, specified value RS5_CAM_ADJ_EXH_SPEC
- Service 22
DID 2019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, intake bank 1, actual value RS5_CAM_ADJ_INT_BANK_1_ACT
- Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, intake bank 1, specified value RS5_CAM_ADJ_INT_BANK_1_SPEC
- Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -262.144 to 262.136 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, intake, actual value RS5_CAM_ADJ_INT_ACT
- Service 22
DID 201E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft adjustment, intake, specified value RS5_CAM_ADJ_INT_SPEC
- Service 22
DID 201D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft end position RS5_PQ35_CAMS_END
- Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft position, deviation from the base position RS5_CAM_POS_DEV_BASE_POS
- Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2010 to 2026.
Camshaft start position RS5_PQ35_CAMS_START
- Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 °
- Unit
- °
In testing for 2010 to 2026.
Cat. converter oxygen storage capacity measured RS5_CAT_CONVERTER_OXYGEN_STORAGE_CAPACITY_MEASURED
- Service 22
DID 1507 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Cat. temperature, bank 1 RS5_CAT_T_BANK_1
- Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2010 to 2026.
Cat. temperature, bank 2 RS5_CAT_T_BANK_2
- Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2010 to 2026.
Catalyst temperature, calculated RS5_CAT_T_CALC
- Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2010 to 2026.
Centrifugal oil temperature RS5_PQ35_CENTRIFUGAL_OIL_T
- Service 22
DID 38B2 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2010 to 2026.
Chain elongation inlet, mileage at last adaptation RS5_CHAIN_ELONGATION_INLET
- Service 22
DID 516C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2026.
Chain elongation outlet, mileage at last adaptation RS5_CHAIN_ELONGATION
- Service 22
DID 5149 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2026.
Chain elongation, no of valid initial values, exhaust bank 1 RS5_CHAIN_ELONGATION_NO_VALID_1
- Service 22
DID 4189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Chain elongation, no of valid initial values, intake bank 1 RS5_CHAIN_ELONGATION_NO_1
- Service 22
DID 4187 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Charge air cooler downstream air pressure RS5_AIR_P_CAC_DS
- Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Clutch #1 maximum temperature RS5_PQ35_CLUTCH_1_MAXIMUM_T
- Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch #2 maximum temperature RS5_PQ35_CLUTCH_2_MAXIMUM_T
- Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch 0 temperature calculated RS5_MQB_DL382_CLUTCH_0_T_CALCULATED
- Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch 1 temperature RS5_PQ35_CLUTCH_1_T
- Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch 1 temperature protection overheat protection 1 quantity RS5_MQB_TCM_CLUTCH_1_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Service 22
DID 3881 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 1 temperature protection warning 1 quantity RS5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_1_QTY
- Service 22
DID 387F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 1 temperature protection warning 2 quantity RS5_MQB_TCM_CLUTCH_1_T_PROTECTION_WARNING_2_QTY
- Service 22
DID 3880 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 temperature RS5_PQ35_CLUTCH_2_T
- Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch 2 temperature protection overheat protection 1 quantity RS5_MQB_TCM_CLUTCH_2_T_PROTECTION_OVERHEAT_PROTECTION_1_QTY
- Service 22
DID 3885 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 temperature protection warning 1 quantity RS5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_1_QTY
- Service 22
DID 3883 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 temperature protection warning 2 quantity RS5_MQB_TCM_CLUTCH_2_T_PROTECTION_WARNING_2_QTY
- Service 22
DID 3884 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch center central plate temperature RS5_CLU_CENTER_CENTRAL_T
- Service 22
DID 102A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Clutch temperature calculated RS5_MQB_DL382_CLUTCH_T_CALCULATED
- Service 22
DID 18E3 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Commanded crankshaft torque RS5_CMD_CRANK_TQ
- Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019.
Compression test cylinder 1 RS5_PQ35_COMPRESSION_TEST_CYL_1
- Service 22
DID 1129 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test cylinder 2 RS5_PQ35_COMP_TEST_CYL_2
- Service 22
DID 112A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test cylinder 3 RS5_PQ35_COMP_TEST_CYL_3
- Service 22
DID 112B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test, cylinder 1 RS5_COMPRESSION_TEST_CYL_1
- Service 22
DID 299B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test, cylinder 2 RS5_COMPRESSION_TEST_CYL_2
- Service 22
DID 299C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test, cylinder 3 RS5_COMPRESSION_TEST_CYL_3
- Service 22
DID 299D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compression test, cylinder 4 RS5_COMPRESSION_TEST_CYL_4
- Service 22
DID 299E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Control module temperature RS5_CTRL_MODULE_T
- Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Control module temperature RS5_ENG_CTRL_MODULE_TConfirmed
- Service 22
DID 028D - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 150 °C
- Unit
- °C
0x0BAB = 2987 → = 25.6 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Control module temperature RS5_MQB_TCM_ECU_T
- Service 22
DID 028D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2010 to 2026.
Converter loss torque RS5_MQB_TCM_CONVERTER_LOSS_TORQUE
- Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Coolant circulation pump, activation RS5_CLT_CIRCULATION_PMP_ACTIVATION
- Service 22
DID 276D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant circulation pump, control RS5_CLT_CIRCULATION_PMP
- Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 1 activation, $1117 RS5_CLT_FAN_1_ACTIVATION_1117
- Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 1 duty cycle RS5_PQ35_COOL_FAN_1_DUTY
- Service 22
DID 1116 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 1, activation RS5_CLT_FAN_1_ACTIVATION
- Service 22
DID 2055 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 1, activation RS5_COOLANT_FAN_1_ACTIVATION
- Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 2 duty cycle RS5_PQ35_COOL_FAN_2_DUTY
- Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan 2, activation RS5_CLT_FAN_2_ACTIVATION
- Service 22
DID 2056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant fan, requested by A/C RS5_CLT_FAN_REQ_AC
- Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Coolant shut-off valve, closed RS5_CLT_SHUT_OFF_VLV
- Service 22
DID 2682 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2010 to 2026.
Coolant temperature at engine outlet, calculated RS5_COOLANT_T_AT_ENGINE_OUTLET_CALCULATED
- Service 22
DID 4490 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at engine outlet, calculated RS5_ECT_ENG_OUTLET_CALC
- Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at engine start RS5_COOLANT_T_AT_ENGINE_START
- Service 22
DID 1291 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at engine start RS5_ECT_ENG_START
- Service 22
DID 2935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet RS5_COOLANT_T
- Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet RS5_ECT_RADIATOR_OUTLET
- Service 22
DID 11B5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet 2 RS5_ECT_RAD_OUT_2
- Service 22
DID 109B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet v.1 RS5_ECT_RADIATOR_OUTLET_V_1
- Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet, actual value RS5_ECT_RADIATOR_OUTLET_ACT
- Service 22
DID 202B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet, actual value RS5_ECT_RADIATOR_OUTLET_ACT_7E0
- Service 22
DID 102C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature at radiator outlet, specified value RS5_ECT_RADIATOR_OUTLET_SPEC
- Service 22
DID 202C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature difference between engine and radiator RS5_ECT_DIFF_ENG
- Service 22
DID 202E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature linear RS5_ECT_LINEAR
- Service 22
DID 1513 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -48 to 143.9978 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature modeled value RS5_COOLANT_T_MODELED_VALUE
- Service 22
DID 13A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature, maximum value RS5_ECT_MAX
- Service 22
DID 1511 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2010 to 2026.
Coolant temperature, minimum value RS5_ECT_MIN
- Service 22
DID 1512 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2010 to 2026.
Correction factor of oil temperature for engine protection RS5_CORR_FACTOR_OIL_T
- Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7.99
- Unit
- Number
In testing for 2010 to 2026.
Correction values for main pressure adaptation RS5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT
- Service 22
DID 11A7 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Counter steer support RS5_CNT_STEER_SUPPORT_ACTIVE
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Counter steer support, steering torque RS5_CNT_STEER_SUPPORT_STEERING_TRQ
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 1 N·m
- Unit
- N·m
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Crankshaft rotation angle when closing the quantity control valve RS5_CRANK_ROT_ANG
- Service 22
DID 10EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Critical engine oil level RS5_PQ35_OIL_LVL_CRITConfirmed
- Service 22
DID 11BD - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -131.072 to 131.068 mm
- Unit
- mm
0x0C6E = 3182 → = 12.728 mm
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 0 RS5_CTR_MIS_DC_MMV_CYL_0
- Service 22
DID 148D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 1 RS5_CTR_MIS_DC_MMV_CYL_1
- Service 22
DID 148E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
CTR_MIS_DC_MMV_CYL_SAE, 2 RS5_CTR_MIS_DC_MMV_CYL_2
- Service 22
DID 148F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Current N215 pressure control valve 1 RS5_CURRENT_N215_P_CTRL_1
- Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current N216 pressure control valve 2 RS5_CURRENT_N216_P_CTRL_2
- Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current N217 pressure control valve 3 RS5_CURRENT_N217_P_CTRL_3
- Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current N218 pressure control valve 4 RS5_CURRENT_N218_P_CTRL_4
- Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current N233 pressure control valve 5 RS5_CURRENT_N233_P_CTRL_5
- Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current solenoid RS5_CURRENT_SOLENOID
- Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current type of driver counter RS5_CURRENT_TYPE_DRIVER
- Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Cylinder 1 internal torque RS5_CYL_1_INTERNAL_TQ
- Service 22
DID 5847 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Cylinder 2 internal torque RS5_CYL_2_INTERNAL_TQ
- Service 22
DID 5849 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Cylinder 3 internal torque RS5_CYL_3_INTERNAL_TQ
- Service 22
DID 584B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Cylinder 4 internal torque RS5_CYL_4_INTERNAL_TQ
- Service 22
DID 584D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Cylinder block temperature sensor RS5_CYL_BLOCK_T_SENS
- Service 22
DID 51D4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Cylinder head temperature RS5_CYL_HEAD_T
- Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2010 to 2026.
Desired torque raw RS5_DES_TQ_RAW
- Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Diesel particulate filter differential pressure variant 2 RS5_PQ35_DPF_DIFF_P_2
- Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Diesel particulate filter exhaust gas flow volume RS5_MQB_DPF_EXH_VOL
- Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Number
In testing for 2010 to 2026.
Diesel particulate filter surface temperature RS5_DPF_SFC_T
- Service 22
DID 1044 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2017.
Differential pressure RS5_PQ35_DIFF_P
- Service 22
DID 14F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Direct injections counter RS5_DIRECT_INJECTIONS
- Service 22
DID 4267 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2026.
Driver demand torque RS5_MQB_TCM_DRIVER_DEMAND_TORQUE
- Service 22
DID 100B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Driving mode sensor, hall sensor a RS5_DRIVING_MODE_SENS
- Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Driving position RS5_DRIVING_POS
- Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Driving resistance index RS5_DRIVING_RES_INDEX
- Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2010 to 2026.
Dynamic average of ignition angle delay adjustment RS5_DYNAMIC_AVG_IGN_ANG
- Service 22
DID 294A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Ea888b boost pressure control, adaptation value 0 RS5_EA888B_BOOST_P_CTRL_0
- Service 22
DID 11FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2010 to 2026.
Ea888b boost pressure control, adaptation value 1 RS5_EA888B_BOOST_P_CTRL_1
- Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2010 to 2026.
Ea888b boost pressure control, adaptation value 2 RS5_EA888B_BOOST_P_CTRL_2
- Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2010 to 2026.
Ea888b boost pressure control, adaptation value 3 RS5_EA888B_BOOST_P_CTRL_3
- Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -359.68 to 356.87
- Unit
- Raw value
In testing for 2010 to 2026.
Ea888b boost pressure regulator, commanded RS5_EA888B_BOOST_P_CMD
- Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Early ignition counter for toque reduction, cylinder 1 RS5_EARLY_IGN_CNT_TOQUE_1
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for toque reduction, cylinder 2 RS5_EARLY_IGN_CNT_TOQUE_2
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for toque reduction, cylinder 3 RS5_EARLY_IGN_CNT_TOQUE_3
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for toque reduction, cylinder 4 RS5_EARLY_IGN_CNT_TOQUE_4
- Service 22
DID 4E4A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder 1 RS5_EARLY_IGN_CNT_CYL_1
- Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder 2 RS5_EARLY_IGN_CNT_CYL_2
- Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder 3 RS5_EARLY_IGN_CNT_CYL_3
- Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder 4 RS5_EARLY_IGN_CNT_CYL_4
- Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 1 RS5_EARLY_IGN_CNT_CYL_SUPPRESS_1
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 2 RS5_EARLY_IGN_CNT_CYL_SUPPRESS_2
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 3 RS5_EARLY_IGN_CNT_CYL_SUPPRESS_3
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, cylinder suppress early ignition, cylinder 4 RS5_EARLY_IGN_CNT_CYL_SUPPRESS_4
- Service 22
DID 4E49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, total, cylinder 1 RS5_EARLY_IGN_CNT_TOT_1
- Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, total, cylinder 2 RS5_EARLY_IGN_CNT_TOT_2
- Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, total, cylinder 3 RS5_EARLY_IGN_CNT_TOT_3
- Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter, total, cylinder 4 RS5_EARLY_IGN_CNT_TOT_4
- Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Effective injection duration RS5_EFFECTIVE_INJ_DUR
- Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2010 to 2026.
EGT after catalyst, model bank b RS5_EGT_AFTER_CAT_MODEL_B
- Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2010 to 2026.
Elector motor 1 torque RS5_EM_TORQ_1Confirmed
- Service 22
DID 1153 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1000 to 1000 N·m
- Unit
- N·m
0x2281 = 8833 → = 276.03125 N·m
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Elector motor 3 torque RS5_EM_TORQ_3
- Service 22
DID 1155 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1000 to 1000 N·m
- Unit
- N·m
In testing for 2010 to 2017. Not supported for 2019.
Electric additional coolant pump control, high circle RS5_ELEC_ADDITIONAL_CLT
- Service 22
DID 1488 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Electric motor 2 torque RS5_EM_TORQ_2Confirmed
- Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1000 to 1000 N·m
- Unit
- N·m
0x11F0 = 4592 → = 143.5 N·m
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Electric motor non-vehicle power limitation RS5_EM_NV_PWR_LIM
- Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
- Range
- 0 to 12750 W
- Unit
- W
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Electric motor power limitation RS5_EM_PWR_LIM
- Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
- Range
- 0 to 3276750 W
- Unit
- W
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Energy balance of last driving cycle RS5_ENERGY_BALANCE_LAST
- Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Energy content RS5_ENERGY_CONTENT
- Service 22
DID 22E4 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
In testing for 2010 to 2026.
Engine air mass, specified value RS5_ENG_AIR_MASS_SPEC
- Service 22
DID 2037 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2026.
Engine compartment temperature raw value RS5_ENG_COMPARTMENT_T
- Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019.
Engine drag torque RS5_ENG_DRAG_TQ
- Service 22
DID 209C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine oil level RS5_ENG_OIL_LEVEL_7E0
- Service 22
DID 1504 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mm
- Unit
- mm
In testing for 2010 to 2026.
Engine oil level RS5_PQ35_OIL_LVL
- Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -131.072 to 131.068 mm
- Unit
- mm
In testing for 2010 to 2026.
Engine oil level current value RS5_ENG_OIL_LEVEL
- Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Engine oil pressure RS5_EOP
- Service 22
DID 1503 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 157 psi
- Unit
- psi
In testing for 2010 to 2026.
Engine oil sump temperature RS5_ENG_OIL_SUMP_T
- Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -460 to 11336.3 °F
- Unit
- °F
In testing for 2010 to 2026.
Engine oil temperature RS5_EOT
- Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine oil temperature RS5_EOT_7E0
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine oil temperature RS5_EOT_7E0_7E0
- Service 22
DID 1102 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine oil temperature measured value RS5_EOT_MEAS
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 1632 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine oil temperature sensor 2 RS5_EOT_SENS_2
- Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine oil temperature, pulse sensor RS5_EOT_PULS
- Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine outlet coolant temperature calculated RS5_ENG_OUTLET_ECT_CALC
- Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Engine protection, torque limit RS5_ENG_PROTECTION_TQ
- Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine radiator fan request RS5_ENG_RADIATOR_FAN_REQ
- Service 22
DID 100B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Engine start quantity RS5_PQ35_ENG_START_QTY
- Service 22
DID 1069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Engine temperature control actuator RS5_ENG_T_CTRL_ACTUATOR
- Service 22
DID 3D73 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Engine temperature management actuator, after-run stop RS5_ENG_T_MANAGEMENT_ACTUATOR_AFTER
- Service 22
DID 441D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Engine temperature management actuator, duty cycle activation RS5_ENG_T_MANAGEMENT_ACTUATOR
- Service 22
DID 441A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Engine temperature management actuator, raw value RS5_ENG_T_MANAGEMENT
- Service 22
DID 4419 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Engine temperature management actuator, specified value RS5_ENG_T_MANAGEMENT_SPEC
- Service 22
DID 3FE4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -399.9989 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Engine temperature management actuator, stop open RS5_ENG_T_MANAGEMENT_ACTUATOR_STOP
- Service 22
DID 441C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Engine torque RS5_ENG_TQ
- Service 22
DID 2002 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_ENG_TQ_7E0
- Service 22
DID 437C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_ENG_TQ_7E1
- Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_ENGINE_TORQUE
- Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_MQB_TCM_ENG_TORQUE
- Service 22
DID 7064 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_MQB_TCM_ENGINE_TORQUE
- Service 22
DID 100C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_PQ35_ENG_TORQUE
- Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1024 to 1023.968 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque RS5_PQ35_ENG_TRQ
- Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque limitation RS5_ENG_TQ_LIM
- Service 22
DID 108F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque limitation RS5_MQB_TCM_ENGINE_TORQUE_LIMITATION
- Service 22
DID 100E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Engine torque loss RS5_MQB_TCM_ENGINE_TORQUE_LOSS
- Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Environment data camshaft input 1 RS5_PQ35_ENVD_CAM_IN_1
- Service 22
DID 1213 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Excessive temperature protection RS5_EXCESSIVE_T
- Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Exhaust camshaft, adaptation bias RS5_EXH_CAM_ADPT_BIAS
- Service 22
DID 174A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2010 to 2026.
Exhaust camshaft, adaptation sensor tolerance RS5_EXH_CAM_ADPT_SENS
- Service 22
DID 1755 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2010 to 2026.
Exhaust gas temperature RS5_EXH_GAS_T
- Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature - calculated after catalyst RS5_EXH_GAS_T_CALC_AFTER
- Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.9904 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature at probe before precat, model value RS5_EXHAUST_GAS_T_AT_PROBE_BEFOR_PRECAT_MODEL_VALUE
- Service 22
DID 139C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature before catalyst RS5_EXHAUST_GAS_T_BEFORE_CATALYST
- Service 22
DID 1282 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -193.93 to 1116.77 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature before catalytic converter RS5_EXH_GAS_T_BEFORE
- Service 22
DID 296F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 1 RS5_EXH_GAS_T_SENS_1
- Service 22
DID 2976 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 1 RS5_EXH_GAS_T_SENS_1_7E0
- Service 22
DID 166F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 1 RS5_PQ35_EXH_GAS_T_1
- Service 22
DID 10FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 1, bank 2 RS5_EXH_GAS_T_SENS_1_2
- Service 22
DID 1670 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 2 RS5_PQ35_EXHAUST_GAS_T_SENSOR_2
- Service 22
DID 14F7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 3 RS5_EXH_GAS_T_SENS_3
- Service 22
DID 14BE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 3, bank 2 RS5_EXH_GAS_T_SENS_3_2
- Service 22
DID 156F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature sensor 4 RS5_EXH_GAS_T_SENS_4
- Service 22
DID 166D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust gas temperature, sensor 4, bank 2 RS5_EXH_GAS_T_S4_B2
- Service 22
DID 166E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust temperature before the catalyst, modeled RS5_EXH_T_BEFORE_CAT
- Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Exhaust temperature control downstream oxidation catalyst filtered model error RS5_MQB_EXH_TEMP_CTRL_AFTER_CAT_MODEL_ERR
- Service 22
DID 1AD7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Field limit value RS5_PQ35_FIELD_LIM
- Service 22
DID 11F6 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2010 to 2026.
Front left deflector temperature RS5_CLIMATE_FR_L_DEFL_TConfirmed
- Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x00BF = 191 → = 19.1 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Front left temperature flap actual value RS5_CLIMATE_FR_L_T_FLP_ACT_VALUE
- Service 22
DID 2622 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right deflector temperature RS5_CLIMATE_FR_R_DEFL_TConfirmed
- Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x00BB = 187 → = 18.7 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Front right temperature flap actual value RS5_CLIMATE_FR_R_T_FLP_ACT_VALUE
- Service 22
DID 2626 - Module
746 → 7B0 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Fuel metering valve position RS5_PQ35_FUEL_METER
- Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Fuel temperature RS5_PQ35_FUEL_T
- Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Generator current RS5_GEN_CURRENT
- Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6562.5 A
- Unit
- A
In testing for 2010 to 2026.
Generator load RS5_PQ35_GEN_LOAD
- Service 22
DID 105C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Generator load normalized value RS5_GENERATOR_LOAD_NORMALIZED_VALUE
- Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Generator load signal RS5_GEN_LOAD_SIG
- Service 22
DID 2050 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Generator load signal RS5_GEN_LOAD_SIG_7E0
- Service 22
DID 1033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Generator load signal RS5_GENERATOR_LOAD_SIG
- Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Generator performance RS5_GENERATOR_PERFORMANCE
- Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -308831.8464 to 308822.421 W
- Unit
- W
In testing for 2010 to 2026.
Generator torque request RS5_GENERATOR_TORQUE_REQUEST
- Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Heater circulation pump, nominal value RS5_HEATER_CIRCULATION
- Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Heater support pump, specified value RS5_HEATER_SUPPORT_PMP_SPEC
- Service 22
DID 4336 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Height correction RS5_HEIGHT_CORR
- Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 3.9999
- Unit
- Number
In testing for 2010 to 2026.
High pressure control, adaptation RS5_HIGH_P_CTRL_ADPT
- Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2010 to 2026.
High pressure regulation, adaptation value RS5_HIGH_P_REGULATION
- Service 22
DID 4384 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Hill descent control RS5_HDC_ACTIVE
- Service 22
DID 1808 - Module
713 → 77D - Every
2 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Hill descent control, incline RS5_HDC_INCLINE
- Service 22
DID 1808 - Module
713 → 77D - Every
2 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Hybrid temperature RS5_MQB_TCM_HYBRID_T
- Service 22
DID 1196 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010 to 2026.
ID of current driving program RS5_ID_CURRENT_DRIVING
- Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
IGA_CYL_KNK, 0 RS5_IGA_CYL_KNK_0
- Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
IGA_CYL_KNK, 1 RS5_IGA_CYL_KNK_1
- Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
IGA_CYL_KNK, 2 RS5_IGA_CYL_KNK_2
- Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
IGA_CYL_KNK, 3 RS5_IGA_CYL_KNK_3
- Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
IGA_IGC, 0 RS5_IGA_IGC_0
- Service 22
DID 138A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2010 to 2026.
IGA_IGC, 1 RS5_IGA_IGC_1
- Service 22
DID 138B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2010 to 2026.
IGA_IGC, 2 RS5_IGA_IGC_2
- Service 22
DID 138C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2010 to 2026.
IGA_IGC, 3 RS5_IGA_IGC_3
- Service 22
DID 138D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -35.625 to 59.9362 °
- Unit
- °
In testing for 2010 to 2026.
Ignition angle current cylinder, actual value RS5_IGN_ANG_CURRENT_CYL_ACT
- Service 22
DID 2004 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -25 to 25 °
- Unit
- °
In testing for 2010 to 2026.
Ignition timing angle retard, cylinder 4 RS5_IGNITION_TIMING_ANGLE_RETARD_C4
- Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -24576 to 24575.25 °
- Unit
- °
In testing for 2010 to 2026.
Injection amount deviation cylinder 1 RS5_INJ_AMOUNT_DEV_CYL_1
- Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2010 to 2026.
Injection amount deviation cylinder 2 RS5_INJ_AMOUNT_DEV_CYL_2
- Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2010 to 2026.
Injection amount deviation cylinder 2 RS5_INJ_AMOUNT_DEV_CYL_2_7E0
- Service 22
DID 1106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Injection amount deviation cylinder 3 RS5_INJ_AMOUNT_DEV_CYL_3
- Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2010 to 2026.
Injection amount deviation cylinder 4 RS5_INJ_AMOUNT_DEV_CYL_4
- Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -12 to 12
- Unit
- Raw value
In testing for 2010 to 2026.
Injection amount deviation cylinder 5 RS5_INJ_AMOUNT_DEV_CYL_5
- Service 22
DID 1107 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Injector 1 rail pressure calibration point 1 RS5_PQ35_INJ_1_RAIL_P_1
- Service 22
DID 10D0 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 1 rail pressure calibration point 2 RS5_PQ35_INJ_1_RAIL_P_2
- Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 2 rail pressure calibration point 1 RS5_PQ35_INJ_2_RAIL_P_1
- Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 2, rail pressure calibration point 1 RS5_INJ_2_RAIL_P_1
- Service 22
DID 10D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 3 rail pressure calibration point 1 RS5_PQ35_INJ_3_RAIL_P_1
- Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 4 rail pressure calibration point 3 RS5_PQ35_INJ_4_RAIL_P_3
- Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.6384 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Injector 5, rail pressure calibration point 2 RS5_INJ_5_RAIL_P_2
- Service 22
DID 10DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2026.
Inlet flaps - actual value RS5_INLET_FLAPS_ACT
- Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Inlet flaps - requested value RS5_INLET_FLAPS_REQ
- Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Intake air temperature RS5_IAT_7E0
- Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2010 to 2026.
Intake air temperature before throttle valve, raw value RS5_IAT_BEFORE_THROTTLE
- Service 22
DID 15C1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2010 to 2026.
Intake air temperature in intake manifold RS5_INTAKE_AIR_T_IN_INTAKE_MANIFOLD
- Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2010 to 2026.
Intake air temperature raw value RS5_IAT_RAW
- Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Intake camshaft adaptation unit 1 phase length RS5_PQ35_CAMS_ADAPT_PHASE_1
- Service 22
DID 12FE - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 2 RS5_PQ35_CAMS_EDGE_POS_2
- Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 3 RS5_PQ35_CAMS_EDGE_POS_3
- Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 4 RS5_PQ35_CAMS_EDGE_POS_4
- Service 22
DID 118B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 5 RS5_PQ35_CAMS_EDGE_POS_5
- Service 22
DID 118C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 6 RS5_PQ35_CAMS_EDGE_POS_6
- Service 22
DID 118D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 7 RS5_PQ35_CAMS_EDGE_POS_7
- Service 22
DID 118E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted edge 8 RS5_PQ35_CAMS_EDGE_POS_8
- Service 22
DID 118F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft signal edge position adapted value edge 1 RS5_PQ35_INTAKE_CAMSHAFT_SIGNAL_EDGE_POS_ADAPTED_VALUE_EDGE_1
- Service 22
DID 173A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft, adaptation bias RS5_INT_CAM_ADPT_BIAS
- Service 22
DID 174B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2010 to 2026.
Intake camshaft, adaptation sensor tolerance RS5_INT_CAM_ADPT_SENS
- Service 22
DID 1740 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -720.0112 to 719.9892 °
- Unit
- °
In testing for 2010 to 2026.
Intake manifold pressure calculated RS5_MQB_INT_MAN_P
- Service 22
DID 103C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Intake manifold pressure raw value RS5_INT_MANIFOLD_P_RAW
- Service 22
DID 3E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2010 to 2026.
Intake manifold pressure, commanded RS5_INT_MANIFOLD_P_CMD
- Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Intake manifold pressure, corrected RS5_INT_MANIFOLD_P
- Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Intake manifold runner control, acknowledgment RS5_INT_MANIFOLD_RUNNER_CTRL
- Service 22
DID 206A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Intake manifold runner control, activation RS5_INT_MANIFOLD_RUNNER
- Service 22
DID 2069 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Intake model air mass flow filtered value RS5_INT_MODEL_AIR_MASS
- Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Intake phase deviation, actual value RS5_INT_PHASE_DEV_ACT
- Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2010 to 2026.
Integrated mass of air since engine start RS5_INTEGRATED_MASS_AIR
- Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2010 to 2026.
Integrated mass of air since the first engine start RS5_INTEGRATED_MASS_AIR_SINCE
- Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 23301.6246
- Unit
- Raw value
In testing for 2010 to 2026.
Intercooler air output temperature RS5_PQ35_INTERCOOLER_AIR_OUTPUT_T
- Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Kick down RS5_MQB_TCM_KICK_DOWN
- Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Kilometers driven since last event on K1 RS5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1
- Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 2010 to 2026.
Kilometers driven since last event on K2 RS5_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2
- Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 km
- Unit
- km
In testing for 2010 to 2026.
Knock retard 4 RS5_KNOCK_RETARD_4
- Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2010 to 2026.
Knock sensor 1 test RS5_KNOCK_SENS_1_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Knock sensor 2 test RS5_KNOCK_SENS_2_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Knock sensor 3 test RS5_KNOCK_SENS_3_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Knock sensor 4 test RS5_KNOCK_SENS_4_TEST
- Service 22
DID 393C - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Knock sensor, cylinder 1 RS5_KNOCK_SENS_CYL_1
- Service 22
DID 3960 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor, cylinder 1 RS5_KNOCK_SNS_C1_V_MS
- Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2010 to 2026.
Knock sensor, cylinder 2 RS5_KNOCK_SENS_CYL_2
- Service 22
DID 3961 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor, cylinder 2 RS5_KNOCK_SENS_CYL_2_7E0
- Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3272
- Unit
- Number
In testing for 2010 to 2026.
Knock sensor, cylinder 2 RS5_KNOCK_SNS_C2_V_MS
- Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2010 to 2026.
Knock sensor, cylinder 3 RS5_KNOCK_SENS_CYL_3
- Service 22
DID 3962 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor, cylinder 3 RS5_KNOCK_SNS_C3_V_MS
- Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2010 to 2026.
Knock sensor, cylinder 4 RS5_KNOCK_SENS_CYL_4
- Service 22
DID 3963 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2010 to 2026.
Knock sensor, cylinder 4 RS5_KNOCK_SNS_C4_V_MS
- Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 3276
- Unit
- Number
In testing for 2010 to 2026.
Lambda output value RS5_LAMBDA_OUTPUT
- Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2026.
Lambda, actual value RS5_LAMBDA_ACT
- Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.9999 to 7.9997
- Unit
- Number
In testing for 2010 to 2026.
Launch control counter, variant 1 RS5_LAUNCH_CTRL_CNT_VAR_1
- Service 22
DID 1200 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Launch control counter, variant 2 RS5_LAUNCH_CTRL_CNT_VAR_2
- Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Leg deflector temperature RS5_CLIMATE_LEG_DEFL_T
- Service 22
DID 2611 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 84.915 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Long term fuel trim at idle, direct injection RS5_LONG_TERM_FUEL_TRIM_IDLE
- Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Long term fuel trim at idle, port injection RS5_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1536 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Long-term adaptation of intake manifold injection RS5_LONG_TERM_ADPT_INT
- Service 22
DID 414E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Long-term adaptation of intake manifold injection at idle RS5_LONG_TERM_ADPT_INT_MANIFOLD_INJ
- Service 22
DID 414F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Lost torque adaptation A/C + driving mode RS5_LOST_TQ_ADPT_AC
- Service 22
DID 437F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Lost torque adaptation driving mode RS5_LOST_TQ_ADPT_DRIVING
- Service 22
DID 437E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Lower adapted coupling point K2 from micro-slip path adaptation RS5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_K2_FROM_MICRO_SLIP_PATH_ADAPT
- Service 22
DID 110A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
M009, desired solenoid out 10 RS5_M009_DES_SOLENOID_10
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
M009, desired solenoid out 11 RS5_M009_DES_SOLENOID_11
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
M009, desired solenoid out 12 RS5_M009_DES_SOLENOID_12
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
M009, desired solenoid out 13 RS5_M009_DES_SOLENOID_13
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
M009, desired solenoid out 14 RS5_M009_DES_SOLENOID_14
- Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Main cat oxygen storage capacity age correction factor RS5_MAIN_CAT_OSC_AGE_CORRECTION_FACTOR
- Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2010 to 2026.
Manifold absolute pressure, raw value RS5_MAP_RAW
- Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Manual engine starts counter RS5_MANUAL_ENG_STARTS
- Service 22
DID 2998 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Mass air flow over throttle valve RS5_MAF_OVER_THROTTLE
- Service 22
DID 394F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2026.
Mass air flow rate RS5_MAF_RATE
- Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2010 to 2026.
Mass air flow through throttle RS5_MAF_THROUGH_THROTTLE
- Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Mass air flow, commanded RS5_MAF_CMD
- Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Mass airflow sensor 1 bank 1 raw value RS5_MQB_MAF_1_B1_RAW
- Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2010 to 2026.
Mass flow through throttle valve RS5_MASS_FLOW_THROUGH
- Service 22
DID 110A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2010 to 2026.
Max permissible engine torque RS5_MAX_PERMISSIBLE_ENG
- Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Maximum ECU temperature RS5_MAX_ECU_T
- Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Maximum filling correction factor from knock control RS5_MAX_FILLING_CORR
- Service 22
DID 10E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.96
- Unit
- Number
In testing for 2010 to 2026.
Maximum oil level for the service interval RS5_MAX_OIL_LEVEL
- Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Mean engine air mass RS5_MEAN_ENG_AIR_MASS
- Service 22
DID 2032 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2026.
Mean engine air mass RS5_PQ35_MEAN_AIR_MASS
- Service 22
DID 1314 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2047.968
- Unit
- Raw value
In testing for 2010 to 2026.
Mean injection quantity RS5_MEAN_INJ_QUANTITYConfirmed
- Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
0x3C27 = 15399 → = 153.99
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Mileage with ECU installed RS5_MILEAGE_ECU
- Service 22
DID 10A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2010 to 2026.
Minimum oil level for the service interval RS5_MIN_OIL_LEVEL
- Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Misfires / 1000 revolutions, cylinder 1 RS5_MISFIRES_1000REV_C1
- Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires / 1000 revolutions, cylinder 2 RS5_MISFIRES_1000REV_C2
- Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 1 RS5_MIS_CNT_1
- Service 22
DID 147E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 2 RS5_MIS_CNT_2
- Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 3 RS5_MIS_CNT_3
- Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 4 RS5_MIS_CNT_4
- Service 22
DID 147F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 5 RS5_MIS_CNT_5
- Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires counter:, cylinder 6 RS5_MIS_CNT_6
- Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions 2 RS5_MIS_PER_1000_2_7E0_7E0
- Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions 4 RS5_MIS_PER_1000_4_7E0
- Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 1, port injection RS5_MIS_PER_1000_1
- Service 22
DID 426B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 2 RS5_MIS_PER_1000_2_7E0
- Service 22
DID 10F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 2, port injection RS5_MIS_PER_1000_2
- Service 22
DID 426C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 3 RS5_MIS_PER_1000_3_7E0
- Service 22
DID 10F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 3, port injection RS5_MIS_PER_1000_3
- Service 22
DID 426D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 revolutions, cylinder 4, port injection RS5_MIS_PER_1000_4
- Service 22
DID 426E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires total RS5_MIS_TOT
- Service 22
DID 2904 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires total RS5_MISFIRES_TOTAL
- Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 1 RS5_MIS_1
- Service 22
DID 10F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 1 RS5_MISFIRES_C1
- Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 2 RS5_MIS_2
- Service 22
DID 10FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 2 RS5_MISFIRES_C2
- Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 3 RS5_MIS_3
- Service 22
DID 10F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 3 RS5_MISFIRES_C3
- Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 3 RS5_MISFIRES_C3_ECM
- Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 4 RS5_MIS_4
- Service 22
DID 10F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires, cylinder 4 RS5_MISFIRES_C4
- Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Mixture adaptation factor at partial load RS5_MIXTURE_ADPT_FACTOR
- Service 22
DID 3996 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
N_32 RS5_N_32
- Service 22
DID 117D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2010 to 2026.
NL_PRE, 0 RS5_NL_PRE_0
- Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2010 to 2026.
NL_PRE, 1 RS5_NL_PRE_1
- Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2010 to 2026.
NL_PRE, 2 RS5_NL_PRE_2
- Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2010 to 2026.
NL_PRE, 3 RS5_NL_PRE_3
- Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 4.9999 V
- Unit
- V
In testing for 2010 to 2026.
Number of injections RS5_NUM_INJECTIONS
- Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Number of times the permitted centrifugal oil temperature has been exceeded RS5_NUM_TIMES_PERMITTED_T
- Service 22
DID 1154 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Number of warnings due to increased centrifugal oil temperature RS5_NUM_WARN_HI_CENTRIF_T
- Service 22
DID 1155 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
NV energy requirement RS5_NV_ENERGY
- Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2010 to 2026.
Oil ash residue RS5_PQ35_OIL_ASH_RESIDUE
- Service 22
DID 178C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5
- Unit
- Raw value
In testing for 2010 to 2026.
Oil dynamic average measurement RS5_PQ35_OIL_DYN_AVG
- Service 22
DID 123F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil fill level RS5_PQ35_OIL_FILL_LEVEL
- Service 22
DID 2006 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1966.08 to 1966.02 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil last dynamic measurement RS5_PQ35_OIL_DYN_LAST
- Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil level RS5_OIL_LEVELConfirmed
- Service 22
DID 11BA - Module
7E0 → 7E8 - Every
30 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
0x3CB1 = 15537 → = 6.2148 cm
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Oil level method 1 RS5_OIL_LEVEL_METHOD_1
- Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2010 to 2026.
Oil level method 2 RS5_OIL_LEVEL_METHOD_2
- Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2010 to 2026.
Oil level method 3 RS5_OIL_LEVEL_METHOD_3
- Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2010 to 2026.
Oil level test method 1 RS5_OIL_LEVEL_TEST_1
- Service 22
DID 4E51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Oil level test method 2 RS5_OIL_LEVEL_TEST_2
- Service 22
DID 4E52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Oil level test method 3 RS5_OIL_LEVEL_TEST_3
- Service 22
DID 4E53 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Oil level, average dynamic value RS5_OIL_LEVEL_AVG
- Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil level, static measured RS5_OIL_LEVEL_STATIC
- Service 22
DID 15A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil level, static measurement RS5_OIL_LEVEL_STATIC_7E0
- Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2010 to 2026.
Oil p RS5_OIL_P
- Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Oil pressure actual RS5_MQB_TCM_EOP_ACTUAL
- Service 22
DID 381D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2010 to 2026.
Oil pressure actual current RS5_MQB_TCM_EOP_ACTUAL_I
- Service 22
DID 381E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2010 to 2026.
Oil pressure control valve activation pulse duty factor RS5_OIL_P_CTRL_VLV
- Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Oil pressure control valve, activation pulse duty factor RS5_OIL_P_CTRL_VLV_ACTIVATION
- Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Oil pressure sensor raw value RS5_OIL_P_SENS_RAW
- Service 22
DID 4FBE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status RS5_OIL_P_SENS_PISTON
- Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure sensor, raw value RS5_OIL_P_SENS_RAW_7E0
- Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure switch activation, high pressure RS5_OIL_P_SWITCH_P
- Service 22
DID 20A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure switch for high pressure, closed RS5_OIL_P_SWITCH_HIGH_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Oil pressure switch for low pressure, closed RS5_OIL_P_SWITCH_LOW_P
- Service 22
DID 20A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Oil pressure switch for piston-cooling jets, closed RS5_OIL_P_SWITCH_PISTON
- Service 22
DID 4270 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure switch valve activation RS5_OIL_P_SWITCH_VLV
- Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure target RS5_OIL_P_TGT
- Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Oil pressure target RS5_OIL_P_TGT_7E0
- Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Oil pressure valve for piston cooling nozzles, control switch button ratio RS5_OIL_P_VLV_PISTON
- Service 22
DID 2CD8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Oil pressure valve switch, control RS5_OIL_P_VLV_SWITCH
- Service 22
DID 11B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Oil pressure, actual value RS5_OIL_P_ACT_7E0
- Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Oil pressure, actual value RS5_OIL_P_ACT_7E0_2
- Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Oil pressure, actual value RS5_OIL_P_ACT_7E0_2_7E0
- Service 22
DID 381D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Oil temp 2 RS5_PQ35_ENGINE_OIL_T_2
- Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Oil temperature RS5_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 10A7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Oil temperature RS5_PQ35_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Service 22
DID 202F - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -58 to 197 °C
- Unit
- °C
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Oil temperature variant RS5_PQ35_OIL_T_2Confirmed
- Service 22
DID 11BE - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 500 °C
- Unit
- °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Oil thermal wear RS5_DASH_OIL_THERMAL_WEARConfirmed
- Service 22
DID 224B - Module
714 → 77E - Every
300 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
0x0032 = 50 → 50 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Oil warning threshold RS5_OIL_WARN_THR
- Service 22
DID 2007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mm
- Unit
- mm
In testing for 2010 to 2026.
Open cam shaft angle at quantity control valve RS5_OPEN_CAM_SHFT_ANG
- Service 22
DID 10EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2010 to 2026.
Outside temperature RS5_OUTSIDE_T
- Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2010 to 2026.
Outside temperature, system calculated RS5_OUTSIDE_T_SYSTEMConfirmed
- Service 22
DID 260A - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 100 °C
- Unit
- °C
0x004D = 77 → = 7.7 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Overall energy balance RS5_OVERALL_ENERGY
- Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Oxygen control, adaptation value at part. load RS5_OXYGEN_CTRL_ADPT
- Service 22
DID 39A9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Oxygen sensor 1 bank 1 ceramic temperature RS5_OXYGEN_SNS_1_BANK_1_CERAMIC_T
- Service 22
DID 1290 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.15 to 1262.793 °C
- Unit
- °C
In testing for 2010 to 2026.
Oxygen sensor 1 bank 1 lambda value RS5_PQ35_O2_SEN_1_LAMBDA
- Service 22
DID 113D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 2010 to 2026.
Particle filter, field regeneration lock status RS5_PARTICLE_FLT_FIELD_REGEN
- Service 22
DID 11C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Piston cooling nozzles, control RS5_PISTON_COOLING
- Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Piston-cooling jets, activation RS5_PISTON_COOLING_JETS
- Service 22
DID 4286 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Port injection injections counter RS5_PORT_INJ_INJECTIONS
- Service 22
DID 4268 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2026.
Post-injection 1 start position RS5_PQ35_POST_INJ_1_START
- Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2010 to 2026.
Post-injection 3 activation duration RS5_PQ35_POST_INJ_3_ACTIVATION_DURATION
- Service 22
DID 14CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2010 to 2026.
Post-injection 3 start position RS5_PQ35_POST_INJ_3_START
- Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -655.36 to 655.34 °
- Unit
- °
In testing for 2010 to 2026.
Pre-injection 2 duration RS5_PQ35_PRE_INJ_2_DURATION
- Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
In testing for 2010 to 2026.
Pressure before throttle valve - actual value RS5_P_BEFORE_THROTTLE_ACT
- Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2010 to 2026.
Pressure before throttle valve - sensor measured RS5_P_BEFORE_THROTTLE
- Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 2559.96
- Unit
- Raw value
In testing for 2010 to 2026.
Pressure sensor 1 temperature RS5_MQB_DL382_P_SENSOR_1_T
- Service 22
DID 132A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Pressure sensor 2 temperature RS5_MQB_DL382_P_SENSOR_2_T
- Service 22
DID 132B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Pressure supply actual pressure RS5_MQB_DQ200_P_SUPPLY_ACTUAL_P
- Service 22
DID 1191 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Pressure supply actual pressure analog digital value RS5_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE
- Service 22
DID 102D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_1 RS5_PSN_EDGE_REL_AD_CAM_1
- Service 22
DID 1184 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2010 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_EX_2 RS5_PSN_EDGE_REL_AD_CAM_2
- Service 22
DID 1185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2010 to 2026.
PSN_EDGE_REL_AD_CAM_SAVE_IN_1 RS5_PSN_EDGE_REL_AD_CAM_SAVE_1
- Service 22
DID 1186 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -2048 to 2047.9375 °
- Unit
- °
In testing for 2010 to 2026.
Radiator fan 1, commanded duty RS5_RADIATOR_FAN_1_CMD
- Service 22
DID 109E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Radiator fan 2, commanded duty RS5_RADIATOR_FAN_2_CMD
- Service 22
DID 109C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2026.
Radiator fan actual duty RS5_CLIMATE_RAD_FAN_ACT_DUTYConfirmed
- Service 22
DID 2606 - Module
746 → 7B0 - Every
2 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Radiator fan commanded duty RS5_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Radiator outlet coolant temperature commanded RS5_PQ35_RAD_COOL_T_CMD
- Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Radiator output coolant temp: actual RS5_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUAL
- Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010 to 2026.
Rated drive torque RS5_RATED_DRIVE_TQ
- Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Reached maximum temperature RS5_PQ35_REACHED_MAXIMUM_T
- Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Rear cat converter temperature, main catalytic converter model value RS5_REAR_CAT_CONV_T_MAIN_CAT_CONV_MODEL_VALUE
- Service 22
DID 1272 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
In testing for 2010 to 2026.
Rear deflector temperature RS5_CLIMATE_RR_DEFL_TConfirmed
- Service 22
DID 263D - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0087 = 135 → = 13.5 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Reducing agent tank volume, act. value filtered RS5_REDUCING_AGENT_TANK_ACT
- Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 131 L
- Unit
- L
In testing for 2010 to 2026.
Refrigerant pressure RS5_CLIMATE_REFRIG_P
- Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 51 bar
- Unit
- bar
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Regulation factor total RS5_PQ35_REG_FACTOR
- Service 22
DID 10E4 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 3.276 %
- Unit
- %
In testing for 2010 to 2026.
Relative load value RS5_REL_LOAD
- Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1536.1605
- Unit
- Number
In testing for 2010 to 2026.
Relay for reserve coolant pump status RS5_RELAY_RESERVE_CLT
- Service 22
DID 3999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Requested torque, amount for auxiliary units RS5_REQ_TQ_AMOUNT
- Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Reserve torque RS5_RESERVE_TQ
- Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Result of crankcase ventilation test, fail RS5_RESULT_CRANKCASE_VENTILATION_TEST
- Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Result of crankcase ventilation test, successful RS5_RESULT_CRANKCASE
- Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Route data, active RS5_ROUTE_DATA_ACTIVE
- Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Secondary air injection sensor 1 RS5_SECONDARY_AIR_INJ_1
- Service 22
DID 3F68 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2010 to 2026.
SEG_AD_MMV_ER_H, 0 RS5_SEG_AD_MMV_ER_H_0
- Service 22
DID 1138 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_H, 2 RS5_SEG_AD_MMV_ER_H_2
- Service 22
DID 113A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_H, 3 RS5_SEG_AD_MMV_ER_H_3
- Service 22
DID 113B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_L, 0 RS5_SEG_AD_MMV_ER_L_0
- Service 22
DID 113E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_L, 2 RS5_SEG_AD_MMV_ER_L_2
- Service 22
DID 1140 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_L, 3 RS5_SEG_AD_MMV_ER_L_3
- Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_MID, 0 RS5_SEG_AD_MMV_ER_MID_0
- Service 22
DID 1132 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_MID, 1 RS5_SEG_AD_MMV_ER_MID_1
- Service 22
DID 1133 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER_MID, 2 RS5_SEG_AD_MMV_ER_MID_2
- Service 22
DID 1134 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER, 1 RS5_SEG_AD_MMV_ER_1
- Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER, 2 RS5_SEG_AD_MMV_ER_2
- Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
SEG_AD_MMV_ER, 3 RS5_SEG_AD_MMV_ER_3
- Service 22
DID 112F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -7.8125 to 7.8123 %
- Unit
- %
In testing for 2010 to 2026.
Service limit RS5_SERVICE_LIM
- Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Service limit RS5_SERVICE_LIM_7E0
- Service 22
DID 5851 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2010 to 2026.
Service limit value RS5_PQ35_SRV_LIM
- Service 22
DID 12CB - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2010 to 2026.
Service regeneration value, two-byte reply, raw count RS5_SRV_REGEN_VALUEConfirmed
- Service 22
DID 1164 - Module
7E0 → 7E8 - Every
30 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
0x8000 = 32768 → 32,768
Confirmed for 2019. In testing for 2017 to 2018, 2020 to 2026.
SIM card, SIM card in main unit RS5_SIM_CARD_SIM_CARD
- Service 22
DID 1814 - Module
773 → 7DD - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Spark efficiency deviation at idle RS5_SPARK_EFFICIENCY_DEVConfirmed
- Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 199 %
- Unit
- %
0x06 = 6 → = 4.686 %
Confirmed for 2019. In testing for 2017 to 2018, 2020 to 2026.
Spark efficiency deviation at idle, maximum RS5_SPARK_EFFICIENCY_DEV_MAX
- Service 22
DID 155B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Spark efficiency deviation at part load, maximum RS5_SPARK_EFFICIENCY_DEV_PART_MAX
- Service 22
DID 155C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Stop signal switch RS5_MQB_TCM_STOP_SIGNAL_SWITCH
- Service 22
DID 3800 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Sum of misfires counter RS5_SUM_MIS_CNT
- Service 22
DID 10F2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Tank fill level diagnostic reference value RS5_TANK_FILL_LEVEL
- Service 22
DID 51D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2010 to 2026.
TCO_1_ST RS5_TCO_1_ST
- Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
TCO_1_SYS RS5_TCO_1_SYS
- Service 22
DID 11CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Temperature after evaporator RS5_CLIMATE_T_AFTER_EVAPConfirmed
- Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
0x0072 = 114 → = 11.4 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Temperature at air conditioner heat exchanger output RS5_T_AC_HEAT_EXCHANGER
- Service 22
DID 1177 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Temperature sensor 14 RS5_T_SENS_14
- Service 22
DID 1EBB - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2010 to 2026.
Temperature sensor for engine temperature management RS5_T_SENS_ENG_T
- Service 22
DID 392A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Temperature sensor for engine temperature management, target value RS5_T_SENS_ENG_T_TGT
- Service 22
DID 40E2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Test of catalytic converter status, canceled RS5_TEST_CATALYTIC_CONV_STAT
- Service 22
DID 2927 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Test of catalytic converter, measured value RS5_TEST_CATALYTIC_CONV
- Service 22
DID 2926 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535
- Unit
- Number
In testing for 2010 to 2026.
Thermostat, actual RS5_THERMOSTAT_ACT
- Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Thermostat, commanded RS5_THERMOSTAT_CMD
- Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Throttle regulator nominal value RS5_THROTTLE_REGULATOR
- Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Throttle valve adapter position RS5_PQ35_THROT_VALVE_ADAPT
- Service 22
DID 12FC - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
TI_1_MPI, 0 RS5_TI_1_MPI_0
- Service 22
DID 13AC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_1_MPI, 1 RS5_TI_1_MPI_1
- Service 22
DID 13AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_1_MPI, 2 RS5_TI_1_MPI_2
- Service 22
DID 13AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_1_MPI, 3 RS5_TI_1_MPI_3
- Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_1, 1 RS5_TI_MES4_PLS_1_1
- Service 22
DID 13A1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_1, 2 RS5_TI_MES4_PLS_1_2
- Service 22
DID 13A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_1, 3 RS5_TI_MES4_PLS_1_3
- Service 22
DID 13A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_2, 0 RS5_TI_MES4_PLS_2_0
- Service 22
DID 13A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_2, 1 RS5_TI_MES4_PLS_2_1
- Service 22
DID 13A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_2, 2 RS5_TI_MES4_PLS_2_2
- Service 22
DID 13A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_2, 3 RS5_TI_MES4_PLS_2_3
- Service 22
DID 13A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_3, 0 RS5_TI_MES4_PLS_3_0
- Service 22
DID 13A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_3, 1 RS5_TI_MES4_PLS_3_1
- Service 22
DID 13A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_3, 2 RS5_TI_MES4_PLS_3_2
- Service 22
DID 13AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
TI_MES4_PLS_3, 3 RS5_TI_MES4_PLS_3_3
- Service 22
DID 13AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2010 to 2026.
Time in after-run RS5_TIME_AFTERRUN
- Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2010 to 2026.
Time since reset RS5_TIME_SINCE_RESET
- Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2010 to 2026.
Timing angle retardation cylinder 1 RS5_PQ35_TIMING_ANGLE_RETARDATION_CYL_1
- Service 22
DID 200A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
Timing angle retardation cylinder 2 RS5_PQ35_TIMING_ANGLE_RETARDATION_CYL_2
- Service 22
DID 200B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
Timing angle retardation cylinder 3 RS5_PQ35_TIMING_ANGLE_RETARDATION_CYL_3
- Service 22
DID 200C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
Timing angle retardation cylinder 4 RS5_PQ35_TIMING_ANGLE_RETARDATION_CYL_4
- Service 22
DID 200D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 47.625 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation after chain replacement, exhaust bank 1 RS5_TIM_DEV_AFTER_CHAIN_REPLACEMENT_1
- Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation after chain replacement, intake bank 1 RS5_TIM_DEV_AFTER_CHAIN_1
- Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation after other repairs, intake bank 1 RS5_TIM_DEV_AFTER_OTHER_1
- Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation after other repairs, intake bank 1 RS5_TIM_DEV_AFTER_OTHER_REPAIRS_INT_1
- Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation current value exhaust bank 1 RS5_TIM_DEV_CURRENT_EXH_1
- Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Timing deviation current value intake bank 1 RS5_TIM_DEV_CURRENT_INT_1
- Service 22
DID 4183 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 °
- Unit
- °
In testing for 2010 to 2026.
Torque converter: torque loss RS5_TORQUE_CONVERTER_TORQUE_LOSS
- Service 22
DID 7053 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque factor RS5_TQ_FACTOR
- Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Torque increase request from ESP RS5_TQ_INCREASE_REQ_ESP
- Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque limit RS5_PQ35_LIM_TRQ
- Service 22
DID 106B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque limitation RS5_TORQUE_LIMITATION
- Service 22
DID 203F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque limitation RS5_TQ_LIM
- Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque limitation RS5_TQ_LIM_7E0
- Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque limitation, clutch protection RS5_TQ_LIM_CLU
- Service 22
DID 20A0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque loss adaptation RS5_TQ_LOSS_ADPT
- Service 22
DID 2122 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque loss adaptation at idle RS5_TQ_LOSS_ADPT_IDLE
- Service 22
DID 1225 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque loss adaptation, A/C compressor RS5_TQ_LOSS_ADPT_AC_COMP_7E0
- Service 22
DID 1223 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque reduction due to exhaust temperature RS5_PQ35_TRQ_RED_EXH_T
- Service 22
DID 10E3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3.2768 to 3.276
- Unit
- Number
In testing for 2010 to 2026.
Torque reduction request from ESP RS5_TQ_REDUCTION_REQ_ESP
- Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque request, sum of auxiliary aggregate RS5_TQ_REQ_SUM_AUXILIARY
- Service 22
DID 209B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque transmitting function, ratio RS5_TQ_TRANSMITTING
- Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553
- Unit
- Number
In testing for 2010 to 2026.
Total mass of gasoline and ethyl alcohol in oil RS5_TOT_MASS_GASOLINE
- Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1398.0581
- Unit
- Raw value
In testing for 2010 to 2026.
Transmission drag torque RS5_TCM_DRAG_TQ
- Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Transmission fluid temperature, calculated RS5_ATF_T_CALCULATED
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 704E - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2026.
Transmission fluid temperature, modeled maximum reached RS5_ATF_T_MODELED_MAX_REACHED
- Service 22
DID 7051 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -55 to 200 °C
- Unit
- °C
In testing for 2010 to 2026.
Transmission torque losses RS5_TCM_TQ_LOSSES
- Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Turbine actuator 1 bank 1 activation RS5_PQ35_TURB_ACT_1_B1
- Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Turbine actuator 1 bank 1: activation RS5_ACT
- Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Upper adapted coupling point K1 from macro slip path adaptation RS5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K1_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Upper adapted coupling point K2 from macro slip path adaptation RS5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_K2_FROM_MACRO_SLIP_PATH_ADAPT
- Service 22
DID 110C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Valve lift system, result of last switch, intake RS5_VLV_LIFT_SYSTEM
- Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Valve lift system, valve lift, exhaust RS5_VLV_LIFT_SYSTEM_VLV_LIFT
- Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Valve lift system, valve lift, intake RS5_VLV_LIFT_SYSTEM_VLV
- Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Valve timing, the difference between the, actual and the set angle RS5_VLV_TIM_DIFF_ACT_SET
- Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -512 to 511.9843 °
- Unit
- °
In testing for 2010 to 2026.
Variable valve timing, intake, bank 1, regulation RS5_VARIABLE_VLV_TIM_INT_1
- Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Variable valve timing, intake, bank 1, switch on RS5_VARIABLE_VLV_TIM_INT_1_ON
- Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Wear index RS5_PQ35_WEAR_IDX
- Service 22
DID 10E2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 m
- Unit
- m
In testing for 2010 to 2026.
Wear index %, 0=new engine RS5_WEAR_INDEX_0_NEW_ENG
- Service 22
DID 20C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
DPF
Service regeneration status RS5_PQ35_SRV_REGEN_STAT
- Service 22
DID 115C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Soot mass calculated RS5_PQ35_SOOT_MASS_CALC
- Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2010 to 2026.
EGR
Exhaust gas recirculation 2: filter press loss, modeled RS5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_MODELED
- Service 22
DID 2AE1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2010 to 2026.
Exhaust gas recirculation 2: filter press loss, simulated RS5_MQB_EXHAUST_GAS_RECIRCULATION_2_FILTER_P_LOSS_SIMULATED
- Service 22
DID 2AE2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3776.8 to 2776.7
- Unit
- Raw value
In testing for 2010 to 2026.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2019.
Fluids
Automatic transmission fluid temperature RS5_ATF_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 2104 - Module
7E1 → 7E9 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
0x40 = 64 → = 24 °C
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Oil level, critical RS5_OIL_CRIT
- Service 22
DID 11BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 26.2 cm
- Unit
- cm
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Oil level, max RS5_OIL_MAX
- Service 22
DID 11C4 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262 cm
- Unit
- cm
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Oil level, min RS5_OIL_MIN
- Service 22
DID 11C5 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 262 cm
- Unit
- cm
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Fuel
Activation of fuel pump electronics RS5_ACTIVATION_FUEL_PMP
- Service 22
DID 2028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Counter of fuel entry in oil RS5_CNT_FUEL_ENTRY_OIL
- Service 22
DID 399F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Error counter bad fuel RS5_ERROR_CNT_BAD_FUEL
- Service 22
DID 44BB - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2026.
Fuel consumption RS5_FUEL_CONSConfirmed
- Service 22
DID 113F - Module
7E0 → 7E8 - Every
30 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
0x0000 = 0 → = 0 L
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Fuel consumption - actual drive cycle RS5_FUEL_CONS_ACT_DRIVE
- Service 22
DID 1519 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2010 to 2026.
Fuel consumption per driving cycle RS5_FUEL_CONS_PER
- Service 22
DID 51D6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2010 to 2026.
Fuel filter: water level sensor 1 RS5_MQB_FUEL_FILTER_WATER_LEVEL_SENSOR_1
- Service 22
DID 197C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Fuel flow RS5_FUEL_FLOW
- Service 22
DID 10A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 L
- Unit
- L
In testing for 2010 to 2026.
Fuel flow rate RS5_PQ35_FUEL_FLOW
Pelican can show this parameter as the fuel rate.
- Service 22
DID 111A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 L
- Unit
- L
In testing for 2010 to 2026.
Fuel high pressure, actual value RS5_FUEL_HIGH_P_ACT
- Service 22
DID 2027 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Fuel high pressure, control deviation RS5_FUEL_HIGH_P_CTRL_DEV
- Service 22
DID 20BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 bar
- Unit
- bar
In testing for 2010 to 2026.
Fuel high pressure, specified value RS5_FUEL_HIGH_P_SPEC
- Service 22
DID 293B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Fuel injector time deviation, cylinder 1 RS5_FUEL_INJ_TIME_DEV_1
- Service 22
DID 2000 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel injector time deviation, cylinder 2 RS5_FUEL_INJ_TIME_DEV_2
- Service 22
DID 207B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel injector time deviation, cylinder 2 RS5_FUEL_INJ_TIME_DEV_CYL_2
- Service 22
DID 21C1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel injector time deviation, cylinder 3 RS5_FUEL_INJ_TIME_DEV_3
- Service 22
DID 2100 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel injector time deviation, cylinder 4 RS5_FUEL_INJ_TIME_DEV_4
- Service 22
DID 2101 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel level RS5_FLI
- Service 22
DID 1008 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2026.
Fuel level RS5_PQ35_FUEL_LEVEL_7E0_2206
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 2206 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level RS5_PQ35_FUEL_LVL
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 2206 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level input RS5_FLI_714
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 229A - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 8191.875 L
- Unit
- L
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Fuel level input % RS5_FLI_INPUT
Pelican can show this parameter as the fuel tank level.
- Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Fuel level input, v1 RS5_FUEL_LEVEL_INPUT_V1
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 14B4 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2010 to 2026.
Fuel level variant RS5_PQ35_FUEL_LVL_2
- Service 22
DID 100C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2010 to 2026.
Fuel low pressure, actual value RS5_FUEL_LOW_P_ACT
- Service 22
DID 2025 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2010 to 2026.
Fuel low pressure, specified value RS5_FUEL_LOW_P_SPEC
- Service 22
DID 2932 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2010 to 2026.
Fuel mass request, integral controller RS5_FUEL_MASS_REQ_I_CTL
- Service 22
DID 130D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel mass request, proportional controller RS5_FUEL_MASS_REQ_P_CTL
- Service 22
DID 1312 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -694 to 694
- Unit
- Raw value
In testing for 2010 to 2026.
Fuel mix correction coefficient RS5_FUEL_MIX_CORR
- Service 22
DID 1710 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273.1 to -73.1003
- Unit
- Number
In testing for 2010 to 2026.
Fuel part from EVAP system RS5_FUEL_PART_EVAP
- Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -0.9996 to 0.9918
- Unit
- Number
In testing for 2010 to 2026.
Fuel pressure regulator position RS5_PQ35_FUEL_P_REG
- Service 22
DID 11BF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Fuel pressure regulator valve: specified value rail pressure RS5_SPEC_VALUE_RAIL_P
- Service 22
DID 121E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2010 to 2017. Not supported for 2019.
Fuel pressure, low actual RS5_FUEL_P_LOW_ACT
- Service 22
DID 1AB8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Fuel pump adaptation RS5_FUEL_PMP_ADPT
- Service 22
DID 11C9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Fuel pump specified value RS5_FUEL_PMP_SPEC
- Service 22
DID 1109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Fuel pump, commanded duty RS5_FUEL_PMP_CMD_DUTY
- Service 22
DID 11A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 99.998 %
- Unit
- %
In testing for 2010 to 2026.
Fuel rate RS5_FUEL_RATE
- Service 22
DID 204C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 L
- Unit
- L
In testing for 2010 to 2026.
Fuel rate difference, injector/sensor RS5_FUEL_RATE_DIFF_INJ
- Service 22
DID 180A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -127.9983 to 127.9944 L
- Unit
- L
In testing for 2010 to 2026.
Fuel tank fill level RS5_FUEL_TANK_FILL_LEVEL
- Service 22
DID 24FC - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2010 to 2026.
Fuel temperature RS5_FUEL_T
- Service 22
DID 128A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2010 to 2026.
Fuel temperature RS5_FUEL_T_7E0
- Service 22
DID 203E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2010 to 2026.
Fuel temperature RS5_FUEL_T_7E0_2
- Service 22
DID 111C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2026.
Fuel volume RS5_FLI_VOL
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 22B0 - Module
714 → 77E - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 L
- Unit
- L
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
High fuel pressure control deviation RS5_HIGH_FUEL_P_CONTROL_DEVIATION
- Service 22
DID 121F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2010 to 2017. Not supported for 2019.
High fuel pressure, actual RS5_HIGH_FUEL_P_ACT
- Service 22
DID 159F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2010 to 2026.
High fuel pressure, actual value RS5_HIGH_FUEL_P_ACT_7E0
- Service 22
DID 4460 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2010 to 2026.
High fuel pressure, commanded RS5_HIGH_FUEL_P_CMD
- Service 22
DID 11D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.7675
- Unit
- Raw value
In testing for 2010 to 2026.
High fuel pressure, regulation error RS5_HIGH_FUEL_P
- Service 22
DID 11D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16.384 to 16.3835
- Unit
- Raw value
In testing for 2010 to 2026.
High fuel pressure, target RS5_HIGH_FUEL_P_TGT
- Service 22
DID 111B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32.76
- Unit
- Raw value
In testing for 2010 to 2026.
High pressure fuel pressure actual RS5_PQ35_FUEL_P_HIGH
- Service 22
DID 1169 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2010 to 2026.
High pressure fuel pressure commanded RS5_PQ35_FUEL_P_HIGH_CMD
- Service 22
DID 116A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276800 to 3276700
- Unit
- Raw value
In testing for 2010 to 2026.
Long term fuel trim at idle RS5_LONG_TERM_FUEL_TRIM_7E0
- Service 22
DID 110E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 %
- Unit
- %
In testing for 2010 to 2026.
Long term fuel trim at idle RS5_LONG_TERM_FUEL_TRIM_IDLE_7E0
- Service 22
DID 4381 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2026.
Long term fuel trim bank 1 RS5_LONG_TERM_FUEL_TRIM_1
- Service 22
DID F407 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2010 to 2026.
Long term fuel trim direct injection at load RS5_LONG_TERM_FUEL_TRIM
- Service 22
DID 1779 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2010 to 2026.
Long term fuel trim port injection at load RS5_LONG_TERM_FUEL_TRIM_PORT
- Service 22
DID 177B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.9999
- Unit
- Number
In testing for 2010 to 2026.
Low fuel pressure, actual RS5_LOW_FUEL_P_ACT
- Service 22
DID 11C8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Low fuel pressure, commanded RS5_LOW_FUEL_P_CMD
- Service 22
DID 11CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 kPa
- Unit
- kPa
In testing for 2010 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, actual RS5_RAT_EVAPORATED_FUEL_ACT
- Service 22
DID 1711 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.9915
- Unit
- Number
In testing for 2010 to 2026.
Ratio between evaporated fuel mass from engine oil and base fuel mass needed, maximum RS5_RAT_EVAPORATED_FUEL_MAX
- Service 22
DID 1712 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.992
- Unit
- Number
In testing for 2010 to 2026.
Short term fuel trim bank 1 RS5_SHORT_TERM_FUEL_TRIM_1
- Service 22
DID F406 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2187 %
- Unit
- %
In testing for 2010 to 2026.
GPS
Satellites, tracked RS5_GPS_SATS_TRACKEDConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0x00 = 0 → 0
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Satellites, visible RS5_GPS_SATS_VISIBLEConfirmed
- Service 22
DID 2431 - Module
767 → 7D1 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
0xFF = 255 → 255
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Lights
Brake light RS5_BRAKE_LIGHT_ONConfirmed
- Service 22
DID 0805 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
0b0 = 0 → 0
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Brake light reading valid? RS5_BRAKE_LIGHT_ON_VALIDConfirmed
- Service 22
DID 0805 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bit 4 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
0b1 = 1 → 1
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Movement
A/C compressor speed RS5_CLIMATE_A_C_COMP_SPD
- Service 22
DID 2603 - Module
746 → 7B0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Acceleration RS5_ACCEL
- Service 22
DID 2116 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276 to 3276 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Acceleration RS5_ACCEL_7E0
- Service 22
DID 10CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Acceleration RS5_ACCELERATION
- Service 22
DID 1187 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Acceleration RS5_ACCELERATION_29BIT
- Service 22
DID 12B0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Acceleration/deceleration mode RS5_ACCEL_DECCELERATION
- Service 22
DID 2118 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Accelerator pedal limit RS5_PQ35_LIM_ACCEL_PED
- Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Accelerator pedal position RS5_ACCEL_PEDAL_POS
- Service 22
DID 3804 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Accelerator pedal position RS5_ACCEL_PEDAL_POS_7E1
- Service 22
DID F449 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Accelerator pedal position 1 RS5_ACCEL_PEDAL_POS_1
- Service 22
DID F449 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Accelerator pedal position 2 RS5_ACCEL_PEDAL_POS_2
- Service 22
DID F44A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Accelerator pedal sensor 1 RS5_PQ35_ACCEL_PED_1
- Service 22
DID 1221 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Accelerator pedal sensor 2 RS5_PQ35_ACCEL_PED_2
- Service 22
DID 102E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2010 to 2026.
Accelerator pedal torque limit RS5_ACCEL_PEDAL_TQ_LIM
- Service 22
DID 1059 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Aux. hydraulic pump RPM RS5_AUX_HYDRAULIC_PMP_RPM
- Service 22
DID 70D6 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 8160 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Camshaft speed RS5_CAM_SPD
- Service 22
DID 1092 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Camshaft speed RS5_CAMSHAFT_VSS
- Service 22
DID 1124 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Camshaft speed RS5_PQ35_CAMS_SPD
- Service 22
DID 133B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -9830.4 to 9830.1 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Compressor speed RS5_COMP_SPD
- Service 22
DID 46E1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Crankshaft speed RS5_CRANKSHAFT_VSS
Pelican can show this parameter as the engine speed.
- Service 22
DID 16F3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Crankshaft speed, RPM RS5_CRANK_SPD_RPM
- Service 22
DID 206E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Engine RPM RS5_RPM
- Service 22
DID F40C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Engine RPM at idle required RS5_ENGINE_RPM_AT_IDLE_REQUIRED
- Service 22
DID 1161 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Front left wheel speed RS5_FL_VSS_V2
- Service 22
DID 1800 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front left wheel speed RS5_TIRE_FL_SPDConfirmed
- Service 22
DID 2B1B - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Front left wheel speed RS5_TIRE_FL_SPD_713
- Service 22
DID 2B1B - Module
713 → 77D - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front left wheel speed RS5_TIRE_FL_SPD_V3
- Service 22
DID 1002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right wheel speed RS5_FR_VSS_V2
- Service 22
DID 1801 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right wheel speed RS5_TIRE_FR_SPDConfirmed
- Service 22
DID 2B1C - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Front right wheel speed RS5_TIRE_FR_SPD_713
- Service 22
DID 2B1C - Module
713 → 77D - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right wheel speed RS5_TIRE_FR_SPD_V3
- Service 22
DID 1001 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Idle speed specified rpm RS5_IDLE_SPD_SPEC_RPM
- Service 22
DID 4056 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Injection speed injector 0 RS5_INJ_SPD_INJ_0
- Service 22
DID 10A4 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Injection speed injector 1 RS5_INJ_SPD_INJ_1
- Service 22
DID 10A5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Injection speed injector 2 RS5_INJ_SPD_INJ_2
- Service 22
DID 10A6 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Injection speed injector 3 RS5_INJ_SPD_INJ_3
- Service 22
DID 10A8 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Input shaft speed 1 RS5_INPUT_SHFT_SPD_1
- Service 22
DID 70E0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Input shaft speed 2 RS5_INPUT_SHFT_SPD_2
- Service 22
DID 70E1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32769 to 7000 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Lateral acceleration RS5_LATERAL_ACCEL
- Service 22
DID 1644 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Longitudinal acceleration RS5_LONGITUDINAL_ACCEL
- Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Longitudinal acceleration, raw RS5_LONGTITUDINAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15CF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Misfires per 1000 rpm, all cylinders RS5_MIS_PER_1000_RPM_ALL
- Service 22
DID 148B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 rpm:, cylinder 1 RS5_MIS_PER_1000_RPM_1
- Service 22
DID 1484 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 rpm:, cylinder 3 RS5_MIS_PER_1000_RPM_3
- Service 22
DID 1486 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 rpm:, cylinder 4 RS5_MIS_PER_1000_RPM_4
- Service 22
DID 1485 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 rpm:, cylinder 5 RS5_MIS_PER_1000_RPM_5
- Service 22
DID 1489 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires per 1000 rpm:, cylinder 6 RS5_MIS_PER_1000_RPM_6
- Service 22
DID 1487 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires/1000 rpm, cylinder 1 RS5_MISFIRES_1000_RPM_C1
- Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires/1000 rpm, cylinder 2 RS5_MISFIRES_1000_RPM_C2
- Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires/1000 rpm, cylinder 3 RS5_MISFIRES_1000_RPM_C3
- Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Misfires/1000 rpm, cylinder 4 RS5_MISFIRES_1000_RPM_C4
- Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Mixture adaptation factor at idle speed RS5_MIXTURE_ADPT_FACTOR_IDLE
- Service 22
DID 3997 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Rear left wheel speed RS5_RL_VSS_V2
- Service 22
DID 1802 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear left wheel speed RS5_TIRE_RL_SPDConfirmed
- Service 22
DID 2B1D - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Rear left wheel speed RS5_TIRE_RL_SPD_713
- Service 22
DID 2B1D - Module
713 → 77D - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear left wheel speed RS5_TIRE_RL_SPD_V3
- Service 22
DID 1004 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear right wheel speed RS5_RR_VSS_V2
- Service 22
DID 1803 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear right wheel speed RS5_TIRE_RR_SPDConfirmed
- Service 22
DID 2B1E - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
0x0000 = 0 → = 0 km/h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Rear right wheel speed RS5_TIRE_RR_SPD_713
- Service 22
DID 2B1E - Module
713 → 77D - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1000 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear right wheel speed RS5_TIRE_RR_SPD_V3
- Service 22
DID 1003 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Reducing agent pump, differential speed calculated RS5_REDUCING_AGENT_PMP
- Service 22
DID 18CC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Specified idle RPM RS5_MQB_DQ250_SPECIFIED_IDLE_RPM
- Service 22
DID 3871 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Speed output RS5_MQB_DQ250_SPD_OUTPUT
- Service 22
DID 1009 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 7000 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Transmission input shaft speed RS5_PQ35_TRANS_IN_SPD
- Service 22
DID 11F1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Transmission input speed RS5_MQB_TCM_TRANSMISSION_INPUT_SPD
- Service 22
DID 2102 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Transmission input speed RS5_MQB_TCM_TRANSMISSION_INPUT_SPD_7E1_380A
- Service 22
DID 380A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Transmission output speed RS5_MQB_TCM_TRANSMISSION_OUTPUT_SPD
- Service 22
DID 2103 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Transmission output speed RS5_MQB_TCM_TRANSMISSION_OUTPUT_SPD_7E1_380B
- Service 22
DID 380B - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Vehicle lateral acceleration, raw value RS5_VEHICLE_LATERAL_ACCELERATION_RAW_VALUE
- Service 22
DID 15D1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 g
- Unit
- g
In testing for 2010 to 2026.
Vehicle speed RS5_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
0x00 = 0 → 0 km/h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Vehicle speed RS5_VSS_7E1
- Service 22
DID F40D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Vehicle speed ESP RS5_VSS_ESP
- Service 22
DID 1005 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Vehicle speed from transmission RS5_MQB_DQ250_VEHICLE_SPD_FROM_TRANSMISSION
Pelican can show this parameter as the speed.
- Service 22
DID 100A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Vehicle speed, HR RS5_VSS_HR
- Service 22
DID 2106 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Yaw acceleration, raw value RS5_YAW_ACCEL_RAW
- Service 22
DID 15D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 m/s²
- Unit
- m/s²
In testing for 2010 to 2026.
Stats
Driving time in eco mode RS5_DRIVE_TIME_ECOConfirmed
Value may be wrong, needs more validation. Proportion of time spent driving in eco mode
- Service 22
DID 0303 - Module
7E1 → 7E9 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0xF8 = 248 → = 99.2 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Driving time in manual mode RS5_DRIVE_TIME_MANUALConfirmed
Value may be wrong, needs more validation. Proportion of time spent driving in manual mode
- Service 22
DID 0305 - Module
7E1 → 7E9 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x00 = 0 → = 0 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Driving time in sport mode RS5_DRIVE_TIME_SPORTConfirmed
Value may be wrong, needs more validation. Proportion of time spent driving in sport mode
- Service 22
DID 0304 - Module
7E1 → 7E9 - Every
1 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
0x02 = 2 → = 0.8 %
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Launch control count RS5_LAUNCH
How many times you've initiated launch control on the car.
- Service 22
DID 5200 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 1000000
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Total drive time RS5_DRIVE_TIMEConfirmed
- Service 22
DID 0302 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383 h
- Unit
- h
0x1686 = 5766 → = 1,441.5 h
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Tires
Entire energy throughput RS5_ENTIRE_ENERGY
- Service 22
DID 2A18 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
- Range
- -838860 to 838860 Ah
- Unit
- Ah
In testing for 2010 to 2026.
Front left flat tire indicator RS5_TPMS_FR_L_FLAT_TIRE_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front left tire pressure diffusion indicator RS5_TPMS_FR_L_TIRE_P_DIFF_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front left wheel speed RS5_FL_WHL_SPD
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Front right flat tire indicator RS5_TPMS_FR_R_FLAT_TIRE_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right tire pressure diffusion indicator RS5_TPMS_FR_R_TIRE_P_DIFF_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Front right wheel speed RS5_FR_WHL_SPD
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Rear left flat tire indicator RS5_TPMS_RR_L_FLAT_TIRE_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear left tire pressure diffusion indicator RS5_TPMS_RR_L_TIRE_P_DIFF_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear left wheel speed RS5_RL_WHL_SPD
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Rear right flat tire indicator RS5_TPMS_RR_R_FLAT_TIRE_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 320 to 327 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear right tire pressure diffusion indicator RS5_TPMS_RR_R_TIRE_P_DIFF_IND
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Rear right wheel speed RS5_RR_WHL_SPD
- Service 22
DID 03E8 - Module
713 → 77D - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 km/h
- Unit
- km/h
In testing for 2010 to 2026.
Steering wheel angle RS5_MQB_SWA_ALT
- Service 22
DID 1804 - Module
713 → 77D - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -14336 to 14335.562 °
- Unit
- °
In testing for 2010 to 2026.
Steering wheel temperature RS5_STEER_WHL_T
- Service 22
DID 5505 - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2010 to 2026.
Tire pressure monitoring available RS5_TPMS_AVAIL
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bit 7 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Transmission
Actual position clutch 1 duty cycle factor 1 RS5_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_1
- Service 22
DID 3832 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Actual position clutch 1 duty cycle factor 2 RS5_MQB_DQ200_ACTUAL_POS_CLUTCH_1_DUTY_CYCLE_FACTOR_2
- Service 22
DID 3833 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Actual position clutch 2 duty cycle factor 1 RS5_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_1
- Service 22
DID 383B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Actual position clutch 2 duty cycle factor 2 RS5_MQB_DQ200_ACTUAL_POS_CLUTCH_2_DUTY_CYCLE_FACTOR_2
- Service 22
DID 383C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Actual position of gear positioner a RS5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_A
- Service 22
DID 3852 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Actual position of gear positioner b RS5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_B
- Service 22
DID 385A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Actual position of gear positioner c RS5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_C
- Service 22
DID 3862 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Actual position of gear positioner d RS5_MQB_DQ250_ACUTAL_POS_GEAR_POSER_D
- Service 22
DID 386A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Adaptation counter PF lockup clutch RS5_ADPT_CNT_PF_LOCKUP
- Service 22
DID 1103 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter torque converter lockup clutch RS5_ADPT_CNT_TSF_LOCKUP
- Service 22
DID 1101 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, clutch a RS5_ADPT_CNT_CLU
- Service 22
DID 7085 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, clutch b RS5_ADPT_CNT_CLU_B
- Service 22
DID 7089 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, clutch c RS5_ADPT_CNT_CLU_C
- Service 22
DID 708D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, clutch d RS5_ADPT_CNT_CLU_D
- Service 22
DID 7091 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, clutch e RS5_ADPT_CNT_CLU_E
- Service 22
DID 7095 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, fast fill time, clutch a RS5_ADPT_CNT_FAST_FILL
- Service 22
DID 7087 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, fast fill time, clutch b RS5_ADPT_CNT_FAST_FILL_B
- Service 22
DID 708B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, fast fill time, clutch c RS5_ADPT_CNT_FAST_FILL_C
- Service 22
DID 708F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, fast fill time, clutch d RS5_ADPT_CNT_FAST_FILL_D
- Service 22
DID 7093 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation counter, fast fill time, clutch e RS5_ADPT_CNT_FAST_FILL_E
- Service 22
DID 7097 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Adaptation inflation current PF lockup clutch RS5_ADPT_INFLATION
- Service 22
DID 1102 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 mA
- Unit
- mA
In testing for 2010 to 2026.
Adaptation inflation time torque converter lockup clutch RS5_ADPT_INFLATION_TIME
- Service 22
DID 1100 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 ms
- Unit
- ms
In testing for 2010 to 2026.
All-wheel drive clutch blockage degree RS5_MQB_HAL_CLUTCH_BLOCK
- Service 22
DID 180A - Module
713 → 77D - Every
1 s - Testing
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
All-wheel drive clutch fully open RS5_MQB_HAL_CLUTCH_OPEN
- Service 22
DID 180A - Module
713 → 77D - Every
1 s - Testing
Bit 2 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2010 to 2026.
Clutch 0 commanded pressure offset RS5_MQB_DL382_CLUTCH_0_CMD_P_OFFSET
- Service 22
DID 1426 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 absolute pressure RS5_MQB_DL382_CLUTCH_1_ABSOLUTE_P
- Service 22
DID 13CC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 actual pressure RS5_PQ35_CLUTCH_1_ACTUAL_P
- Service 22
DID 38EB - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 actual pressure raw value RS5_PQ35_DL382_CLUTCH_1_ACTUAL_P_RAW_VALUE
- Service 22
DID 10F9 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 0 moment RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_0_MOMENT
- Service 22
DID 1058 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 0 position RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_0_POS
- Service 22
DID 1057 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 1 moment RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_1_MOMENT
- Service 22
DID 105A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 1 position RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_1_POS
- Service 22
DID 1059 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 2 moment RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_2_MOMENT
- Service 22
DID 105C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 2 position RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_2_POS
- Service 22
DID 105B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 3 moment RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHARAC_POINT_3_MOMENT
- Service 22
DID 105E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristic point 3 position RS5_PQ35_CLUTCH_1_ADAPT_BASIC_CHAR_POINT_3_POS
- Service 22
DID 105D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristics point 0 position RS5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_0_POS
- Service 22
DID 38AE - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristics point 1 position RS5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_1_POS
- Service 22
DID 38AF - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristics point 2 position RS5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_2_POS
- Service 22
DID 7000 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 adaptation basic characteristics point 3 position RS5_MQB_DQ200_CLUTCH_1_ADAPT_BASIC_CHARS_POINT_3_POS
- Service 22
DID 7001 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 adaptation clutch end position closed RS5_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_CLOSED
- Service 22
DID 38FF - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 adaptation clutch end position open RS5_MQB_DQ200_CLUTCH_1_ADAPT_CLUTCH_END_POS_OPEN
- Service 22
DID 38FE - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 characteristic curve shift RS5_PQ35_CLUTCH_1_CHAR_CURVE_SHIFT
- Service 22
DID 1063 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.11 to 32.111 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 1 commanded pressure RS5_PQ35_CLUTCH_1_CMD_P
- Service 22
DID 38EC - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 failed adaptations counter RS5_PQ35_CLUTCH_1_FAILED_ADAPTS_COUNTER
- Service 22
DID 10CC - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 1 friction value correction factor RS5_PQ35_CLUTCH_1_FRICTION_VALUE_CORRECTION_FACTOR
- Service 22
DID 1062 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Clutch 1 lower adaptation point RS5_CLU_1_LO_ADPT_POINT
- Service 22
DID 1120 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 nominal pressure RS5_CLU_1_NOMINAL_P
- Service 22
DID 125C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 pressure RS5_MQB_DL382_CLUTCH_1_P
- Service 22
DID 214C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 protection function engaged quantity RS5_PQ35_CLUTCH_1_PROT_ENGAGED_QTY
- Service 22
DID 1069 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2026.
Clutch 1 successful adaptations counter RS5_PQ35_CLUTCH_1_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10C9 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 1 upper adaptation point RS5_CLU_1_HI_ADPT_POINT
- Service 22
DID 1124 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 1 valve current: actual RS5_MQB_DQ250_CLUTCH_1_VALVE_I_ACTUAL
- Service 22
DID 3835 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch 1 valve current: specified RS5_MQB_DQ250_CLUTCH_1_VALVE_I_SPECIFIED
- Service 22
DID 3834 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -3276 to 3276.7 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch 2 absolute pressure RS5_MQB_DL382_CLUTCH_2_ABSOLUTE_P
- Service 22
DID 13CD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 actual pressure RS5_PQ35_CLUTCH_2_ACTUAL_P
- Service 22
DID 38EA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 actual pressure raw value RS5_PQ35_DL382_CLUTCH_2_ACTUAL_P_RAW_VALUE
- Service 22
DID 10FA - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 actual torque RS5_MQB_TCM_CLUTCH_2_ACTUAL_TORQUE
- Service 22
DID 3839 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 0 moment RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_0_MOMENT
- Service 22
DID 106D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 0 position RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_0_POS
- Service 22
DID 106C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 1 moment RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_1_MOMENT
- Service 22
DID 106F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 1 position RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_1_POS
- Service 22
DID 106E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 2 moment RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_2_MOMENT
- Service 22
DID 1071 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 2 position RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_2_POS
- Service 22
DID 1070 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 3 moment RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHARAC_POINT_3_MOMENT
- Service 22
DID 1073 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristic point 3 position RS5_PQ35_CLUTCH_2_ADAPT_BASIC_CHAR_POINT_3_POS
- Service 22
DID 1072 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristics point 0 position RS5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_0_POS
- Service 22
DID 38FA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristics point 1 position RS5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_1_POS
- Service 22
DID 38FB - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristics point 2 position RS5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_2_POS
- Service 22
DID 38FC - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation basic characteristics point 3 position RS5_MQB_DQ200_CLUTCH_2_ADAPT_BASIC_CHARS_POINT_3_POS
- Service 22
DID 38FD - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation clutch end position closed RS5_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_CLOSED
- Service 22
DID 38AB - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation clutch end position open RS5_MQB_DQ200_CLUTCH_2_ADAPT_CLUTCH_END_POS_OPEN
- Service 22
DID 38AA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 adaptation end position closed RS5_PQ35_CLUTCH_2_ADAPT_END_POS_CLOSED
- Service 22
DID 1075 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 adaptation end position opened RS5_PQ35_CLUTCH_2_ADAPT_END_POS_OPENED
- Service 22
DID 1074 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 characteristic curve shift RS5_PQ35_CLUTCH_2_CHAR_CURVE_SHIFT
- Service 22
DID 1078 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32.11 to 32.111 mm
- Unit
- mm
In testing for 2010 to 2026.
Clutch 2 commanded pressure RS5_PQ35_CLUTCH_2_CMD_P
- Service 22
DID 38ED - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 failed adaptations counter RS5_PQ35_CLUTCH_2_FAILED_ADAPTS_COUNTER
- Service 22
DID 10ED - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 friction value correction factor RS5_MQB_DQ200_CLUTCH_2_FRICTION_VALUE_CORRECTION_FACTOR
- Service 22
DID 1077 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Clutch 2 lower adaptation point RS5_CLU_2_LO_ADPT_POINT
- Service 22
DID 1121 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 pressure RS5_MQB_DL382_CLUTCH_2_P
- Service 22
DID 214D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -1 to 24.5 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 protection function engaged quantity RS5_PQ35_CLUTCH_2_PROT_ENGAGED_QTY
- Service 22
DID 107E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 successful adaptations counter RS5_PQ35_CLUTCH_2_SUCCESSFUL_ADAPTS_COUNTER
- Service 22
DID 10EA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Clutch 2 upper adaptation point RS5_CLU_2_HI_ADPT_POINT
- Service 22
DID 1125 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Clutch 2 valve current: actual RS5_MQB_DQ250_CLUTCH_2_VALVE_I_ACTUAL
- Service 22
DID 383E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch 2 valve current: specified RS5_MQB_DQ250_CLUTCH_2_VALVE_I_SPECIFIED
- Service 22
DID 383D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 3276.7 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch adaptation values initial kill point 0 for K1 RS5_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K1
- Service 22
DID 1156 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch adaptation values initial kill point 0 for K2 RS5_MQB_DQ250_CLUTCH_ADAPT_VALUES_IKP0_K2
- Service 22
DID 1157 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch adaptation values lower current point adaptation K1 RS5_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K1
- Service 22
DID 1158 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch adaptation values lower current point adaptation K2 RS5_MQB_DQ250_CLUTCH_ADAPT_VALUES_LOWER_I_POINT_ADAPT_K2
- Service 22
DID 1159 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Clutch kiss point rapid adaptation remaining RS5_PQ35_CLUTCH_KISSPOINT_RAPID_ADAPT_REMAINING
- Service 22
DID 1711 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2026.
Clutch overheating, clutch RS5_CLU_OVERHEATING_CLU
- Service 22
DID 17FD - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Clutch temperature RS5_CLU_T
- Service 22
DID 1259 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2026.
Correction values for main press adaptation: high press on clutch 1 RS5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_1
- Service 22
DID 1181 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Correction values for main press adaptation: low press on clutch 1 RS5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_1
- Service 22
DID 1180 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Correction values for main pressure adaptation high pressure on clutch 2 RS5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_HIGH_P_ON_CLUTCH_2
- Service 22
DID 1183 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Correction values for main pressure adaptation low pressure on clutch 2 RS5_MQB_DQ250_CORRECTION_VALUES_MAIN_P_ADAPT_LOW_P_ON_CLUTCH_2
- Service 22
DID 1182 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 bar
- Unit
- bar
In testing for 2010 to 2026.
Current gear RS5_CURRENT_GEAR
- Service 22
DID 3EDE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 256
- Unit
- Number
In testing for 2010 to 2026.
Current gear RS5_MQB_TCM_I_GEARConfirmed
- Service 22
DID 210F - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253
- Unit
- Number
0x02 = 2 → = 0
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Current gear RS5_MQB_TCM_I_GEAR_DQ200
- Service 22
DID 3816 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253
- Unit
- Number
In testing for 2010 to 2026.
Current gear RS5_PQ35_GEAR
- Service 22
DID 100D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127
- Unit
- Number
In testing for 2010 to 2026.
Current lower pressure point clutch 1 from current to pressure adaptation RS5_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1130 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Current lower pressure point clutch 2 from current to pressure adaptation RS5_MQB_DQ250_I_LOWER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1132 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Current N371 pressure control valve 6 lock-up clutch RS5_CURRENT_N371_P_CTRL_6
- Service 22
DID 1029 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2010 to 2026.
Current upper pressure point clutch 1 from current to pressure adaptation RS5_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_1_FROM_I_TO_P_ADAPT
- Service 22
DID 1131 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Current upper pressure point clutch 2 from current to pressure adaptation RS5_MQB_DQ250_I_UPPER_P_POINT_CLUTCH_2_FROM_I_TO_P_ADAPT
- Service 22
DID 1133 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1275 mA
- Unit
- mA
In testing for 2010 to 2026.
Driving strategy mountain factor RS5_PQ35_DRIVING_STRATEGY_MOUNTAIN_FACTOR
- Service 22
DID 1018 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Driving strategy sport factor RS5_PQ35_DRIVING_STRATEGY_SPORT_FACTOR
- Service 22
DID 1019 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Dynamic shift program RS5_DYNAMIC_SHIFT
- Service 22
DID 2115 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for oxygen shift, cylinder 1 RS5_EARLY_IGN_CNT_OXYGEN_1
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for oxygen shift, cylinder 2 RS5_EARLY_IGN_CNT_OXYGEN_2
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for oxygen shift, cylinder 3 RS5_EARLY_IGN_CNT_OXYGEN_3
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Early ignition counter for oxygen shift, cylinder 4 RS5_EARLY_IGN_CNT_OXYGEN_4
- Service 22
DID 4E48 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Engaged position side a gear selector 1-3 RS5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 1138 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side a gear selector 2-4 RS5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 1139 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side a gear selector 5 and neutral RS5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side a gear selector 6 and reverse RS5_MQB_DQ250_ENGAGED_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side b gear selector 1-3 RS5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1144 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side b gear selector 2-4 RS5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1145 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side b gear selector 5 and neutral RS5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 1146 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engaged position side b gear selector 6 and reverse RS5_MQB_DQ250_ENGAGED_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 1147 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Engine specified torque during transmission intervention RS5_ENG_SPEC_TQ_DURING
- Service 22
DID 2110 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Fast fill time, clutch a RS5_FAST_FILL_TIME_CLU
- Service 22
DID 7086 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2010 to 2026.
Fast fill time, clutch b RS5_FAST_FILL_TIME_CLU_B
- Service 22
DID 708A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2010 to 2026.
Fast fill time, clutch c RS5_FAST_FILL_TIME_CLU_C
- Service 22
DID 708E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2010 to 2026.
Fast fill time, clutch d RS5_FAST_FILL_TIME_CLU_D
- Service 22
DID 7092 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2010 to 2026.
Fast fill time, clutch e RS5_FAST_FILL_TIME_CLU_E
- Service 22
DID 7096 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -256 to 254 ms
- Unit
- ms
In testing for 2010 to 2026.
Fill pressure, clutch a RS5_FILL_P_CLU
- Service 22
DID 7084 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2010 to 2026.
Fill pressure, clutch b RS5_FILL_P_CLU_B
- Service 22
DID 7088 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2010 to 2026.
Fill pressure, clutch c RS5_FILL_P_CLU_C
- Service 22
DID 708C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2010 to 2026.
Fill pressure, clutch d RS5_FILL_P_CLU_D
- Service 22
DID 7090 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2010 to 2026.
Fill pressure, clutch e RS5_FILL_P_CLU_E
- Service 22
DID 7094 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1280 to 1270
- Unit
- Raw value
In testing for 2010 to 2026.
Gear RS5_GEAR_V2
- Service 22
DID 14CB - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G1 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G1
- Service 22
DID 1082 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G2 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G2
- Service 22
DID 1090 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G3 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G3
- Service 22
DID 1086 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G4 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G4
- Service 22
DID 1094 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G5 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G5
- Service 22
DID 109E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G6 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G6
- Service 22
DID 10AC - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position G7 RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_G7
- Service 22
DID 10A2 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation engaged position GR RS5_PQ35_GEAR_ACTUATOR_ADAPT_ENGAGED_POS_GR
- Service 22
DID 10B0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G1 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G1
- Service 22
DID 1083 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G2 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G2
- Service 22
DID 1091 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G3 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G3
- Service 22
DID 1085 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G4 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G4
- Service 22
DID 1093 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G5 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G5
- Service 22
DID 109F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G6 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G6
- Service 22
DID 10AD - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position G7 RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_G7
- Service 22
DID 10A1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear actuator adaptation synchronization position reverse RS5_PQ35_GEAR_ACTUATOR_ADAPT_SYNCHRO_POS_GR
- Service 22
DID 10AF - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear selector a adaptation neutral position RS5_PQ35_GANGSTELLER_A_ADAPT_NEUTRALPOS
- Service 22
DID 1084 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear selector b adaptation neutral position RS5_PQ35_GANGSTELLER_B_ADAPT_NEUTRALPOS
- Service 22
DID 1092 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear selector c adaptation neutral position RS5_PQ35_GANGSTELLER_C_ADAPT_NEUTRALPOS
- Service 22
DID 10A0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear selector d adaptation neutral position RS5_PQ35_GANGSTELLER_D_ADAPT_NEUTRALPOS
- Service 22
DID 10AE - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -327.68 to 327.67 mm
- Unit
- mm
In testing for 2010 to 2026.
Gear selector synchronous position G1 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G1
- Service 22
DID 1179 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position G2 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G2
- Service 22
DID 117A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position G3 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G3
- Service 22
DID 117B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position G4 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G4
- Service 22
DID 117C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position G5 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G5
- Service 22
DID 117D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position G6 RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G6
- Service 22
DID 117E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Gear selector synchronous position, reverse RS5_MQB_DQ250_GEAR_SELECTOR_SYNCHRONOUS_POS_G_R
- Service 22
DID 117F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 327.67 %
- Unit
- %
In testing for 2010 to 2026.
Input shaft 1 RS5_MQB_INPUT_SHAFT_1
- Service 22
DID 380C - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Input shaft 2 RS5_MQB_INPUT_SHAFT_2
- Service 22
DID 380D - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Launch control counter, clutch 1 RS5_LAUNCH_CTRL_CNT_CLU_1
- Service 22
DID 38C0 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Load shift flaps, actual value RS5_LOAD_SHIFT_FLAPS_ACT
- Service 22
DID 295C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Load shift flaps, specified value RS5_LOAD_SHIFT_FLAPS_SPEC
- Service 22
DID 295D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Lower adapted coupling point clutch 1 from kiss point adaptation RS5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_KISS_POINT_ADAPT
- Service 22
DID 388D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2010 to 2026.
Lower adapted coupling point clutch 2 from kiss point adaptation RS5_MQB_DQ250_LOWER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_KISS_POINT_ADAPT
- Service 22
DID 388E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2010 to 2026.
Mileage of oxidation catalytic converter RS5_MILEAGE_OXIDATION
- Service 22
DID 51A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2010 to 2026.
Neutral position gear selector 1-3 RS5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_1_3
- Service 22
DID 1140 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Neutral position gear selector 2-4 RS5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_2_4
- Service 22
DID 1141 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Neutral position gear selector 5 and neutral RS5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_5_N
- Service 22
DID 1142 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Neutral position gear selector 6 and reverse RS5_MQB_DQ250_NEUTRAL_POS_GEAR_SELECTOR_6_R
- Service 22
DID 1143 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Nominal pressure clutch 2 RS5_NOMINAL_P_CLU_2
- Service 22
DID 125D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327 to 327 bar
- Unit
- bar
In testing for 2010 to 2026.
Output shaft 1 RS5_MQB_OUTPUT_SHAFT_1
- Service 22
DID 380E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Output shaft 2 RS5_MQB_OUTPUT_SHAFT_2
- Service 22
DID 380F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2010 to 2026.
Powertrain overall gear ratio RS5_POWERTRAIN_OVERALL
- Service 22
DID 11DF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35
- Unit
- Number
In testing for 2010 to 2026.
Pressure_clutch_1 RS5_P_CLU_1
- Service 22
DID 1260 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Pressure_clutch_2 RS5_P_CLU_2
- Service 22
DID 1261 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2026.
Road resistance RS5_PQ35_ROAD_RESISTANCE
- Service 22
DID 1017 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -31 to 31.894 %
- Unit
- %
In testing for 2010 to 2026.
Selected gear RS5_PQ35_SELECTED_GEAR
- Service 22
DID 15AA - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Selected gear RS5_SELECTED_GEAR
- Service 22
DID 7050 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -2 to 253 °C
- Unit
- °C
In testing for 2010 to 2026.
Shift process, selected gear RS5_SHIFT_PROCCESS
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Shift process, target gear RS5_SHIFT_PROCCESS_TGT
- Service 22
DID 70D1 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Specified torque clutch 1 RS5_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_1
- Service 22
DID 382E - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Specified torque clutch 1 - data RS5_SPEC_TQ_CLU_1_DATA
- Service 22
DID 2142 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Specified torque clutch 2 RS5_MQB_DQ250_SPECIFIED_TORQUE_CLUTCH_2
- Service 22
DID 3838 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
- Range
- -1638 to 1638.35 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Specified torque clutch 2 - data RS5_SPEC_TQ_CLU_2_DATA
- Service 22
DID 2143 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -1638 to 1638 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Stiffness point pressure clutch 1 RS5_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_1
- Service 22
DID 1419 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2010 to 2026.
Stiffness point pressure clutch 2 RS5_MQB_DL382_STIFFNESS_POINT_P_CLUTCH_2
- Service 22
DID 141A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32.768 to 32.767 bar
- Unit
- bar
In testing for 2010 to 2026.
Synchronous position side a gear selector 1-3 RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_1_3
- Service 22
DID 113C - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side a gear selector 2-4 RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_2_4
- Service 22
DID 113D - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side a gear selector 5 and neutral RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_5_N
- Service 22
DID 113E - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side a gear selector 6 and reverse RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_A_GEAR_SELECTOR_6_R
- Service 22
DID 113F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side b gear selector 1-3 RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_1_3
- Service 22
DID 1148 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side b gear selector 2-4 RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_2_4
- Service 22
DID 1149 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side b gear selector 5 and neutral RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_5_N
- Service 22
DID 114A - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Synchronous position side b gear selector 6 and reverse RS5_MQB_DQ250_SYNCHRONOUS_POS_SIDE_B_GEAR_SELECTOR_6_R
- Service 22
DID 114B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2010 to 2026.
Time since shift RS5_TIME_SINCE_SHIFT
- Service 22
DID 1033 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2010 to 2026.
Torque converter amplification RS5_TQ_CONV
- Service 22
DID 2130 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 2.55
- Unit
- Number
In testing for 2010 to 2026.
Torque converter lockup clutch status RS5_MQB_TCM_TORQUE_CONVERTER_LOCKUP_CLUTCH_STATUS
- Service 22
DID 7078 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Torque loss adaptation, A/C compressor + gear engaged RS5_TQ_LOSS_ADPT_AC_COMP
- Service 22
DID 1222 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Torque loss adaptation, gear engaged RS5_TQ_LOSS_ADPT_GEAR
- Service 22
DID 1224 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2010 to 2026.
Transmission coolant valve, open RS5_TRANS_CLT_VLV_OPEN
- Service 22
DID 3D74 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2026.
Transmission fluid temperature 2 RS5_ATF_T_2
Pelican can show this parameter as the transmission fluid temperature.
- Service 22
DID 38BF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2026.
Transmission gear ratio RS5_TRANS_GEAR_RAT
- Service 22
DID 0327 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -1.28 to 1.27
- Unit
- Number
In testing for 2010 to 2026.
Transmission part 1 pressure actual RS5_MQB_TCM_TRANSMISSION_PART_1_P_ACTUAL
- Service 22
DID 3821 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2010 to 2026.
Transmission part 1 pressure commanded RS5_MQB_TCM_TRANSMISSION_PART_1_P_CMD
- Service 22
DID 3820 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2010 to 2026.
Transmission part 1 valve current actual RS5_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_ACTUAL
- Service 22
DID 3827 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2010 to 2026.
Transmission part 1 valve current commanded RS5_MQB_TCM_TRANSMISSION_PART_1_VALVE_I_CMD
- Service 22
DID 3826 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2010 to 2026.
Transmission part 2 pressure actual RS5_MQB_TCM_TRANSMISSION_PART_2_P_ACTUAL
- Service 22
DID 3824 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2010 to 2026.
Transmission part 2 pressure commanded RS5_MQB_TCM_TRANSMISSION_PART_2_P_CMD
- Service 22
DID 3823 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655.35 bar
- Unit
- bar
In testing for 2010 to 2026.
Transmission part 2 valve current actual RS5_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_ACTUAL
- Service 22
DID 382B - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2010 to 2026.
Transmission part 2 valve current commanded RS5_MQB_TCM_TRANSMISSION_PART_2_VALVE_I_CMD
- Service 22
DID 382A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 6553.5 mA
- Unit
- mA
In testing for 2010 to 2026.
Upper adapted coupling point clutch 1 from microslip adaptation RS5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_1_FROM_MICROSLIP_ADAPT
- Service 22
DID 388F - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2010 to 2026.
Upper adapted coupling point clutch 2 from microslip adaptation RS5_MQB_DQ250_UPPER_ADAPTED_COUPLING_POINT_CLUTCH_2_FROM_MICROSLIP_ADAPT
- Service 22
DID 3890 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 1.275 A
- Unit
- A
In testing for 2010 to 2026.
Working hours RS5_PQ35_WORKING_HOURS
- Service 22
DID 1110 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.929
- Unit
- Raw value
In testing for 2010 to 2026.
Trips
Analysis, clutch 1 temperature time in range 1 RS5_ANALYSIS_CLU_1_T_1
- Service 22
DID 1066 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 1 temperature time in range 2 RS5_ANALYSIS_CLU_1_T_2
- Service 22
DID 1067 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 1 temperature time in range 3 RS5_ANALYSIS_CLU_1_T_3
- Service 22
DID 1068 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 2 temperature time in range 0 RS5_ANALYSIS_CLU_2_T_0
- Service 22
DID 107A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 2 temperature time in range 1 RS5_ANALYSIS_CLU_2_T_1
- Service 22
DID 107B - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 2 temperature time in range 2 RS5_ANALYSIS_CLU_2_T_2
- Service 22
DID 107C - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Analysis, clutch 2 temperature time in range 3 RS5_ANALYSIS_CLU_2_T_3
- Service 22
DID 107D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Average consumption, category 0 RS5_AVG_CSMP_CAT0Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 1 RS5_AVG_CSMP_CAT1Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 2 RS5_AVG_CSMP_CAT2Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 32 to 47 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 3 RS5_AVG_CSMP_CAT3Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 48 to 63 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 4 RS5_AVG_CSMP_CAT4Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 5 RS5_AVG_CSMP_CAT5Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x00E6 = 230 → = 23 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Average consumption, category 6 RS5_AVG_CSMP_CAT6Confirmed
- Service 22
DID 2AB7 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553 kWh
- Unit
- kWh
0x0000 = 0 → = 0 kWh
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Clutch 1 adaptation kiss point part 1 odometer reading RS5_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READING
- Service 22
DID 10CA - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2010 to 2026.
Clutch 1 temperature time in range 0 RS5_CLU_1_T_TIME_RANGE_0
- Service 22
DID 1065 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 1310.7 s
- Unit
- s
In testing for 2010 to 2026.
Clutch 2 adaptation kiss point part 1 odometer reading RS5_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READING
- Service 22
DID 10EB - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 655350 km
- Unit
- km
In testing for 2010 to 2026.
Counter steer support, odometer, last activated RS5_CNT_STEER_SUPPORT_ODO_RDG_OF_LAST_ACT
- Service 22
DID 18B6 - Module
713 → 77D - Every
900 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
- Range
- 0 to 1 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Distance to empty RS5_PQ35_DIST_EMPTY
Pelican can show this parameter as the fuel range.
- Service 22
DID 2294 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Drive cycles counter RS5_MQB_TCM_DRIVE_CYCLES_COUNTER
- Service 22
DID 388B - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Driving time ecological RS5_MQB_TCM_DRIVING_TIME_ECOLOGICAL
- Service 22
DID 3888 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Driving time manual RS5_MQB_TCM_DRIVING_TIME_MANUAL
- Service 22
DID 388A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Driving time sporty RS5_MQB_TCM_DRIVING_TIME_SPORTY
- Service 22
DID 3889 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Ignition cycles RS5_MQB_TCM_IGNITION_CYCLES
- Service 22
DID 388C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2026.
Mixture variation in adapted part load range 1 RS5_MIXTURE_VARIATION_1
- Service 22
DID 39BC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2010 to 2026.
Odometer RS5_MQB_TCM_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 3841 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer RS5_ODOConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 10E0 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
0x000194AB = 103595 → 103,595 km
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Odometer RS5_ODO_7E0
Pelican can show this parameter as the odometer.
- Service 22
DID 108C - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2010 to 2026.
Odometer RS5_ODO_7E1_2
Pelican can show this parameter as the odometer.
- Service 22
DID 103D - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2026.
Odometer RS5_ODO_ECM
Pelican can show this parameter as the odometer.
- Service 22
DID 295A - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer RS5_PQ35_ODO
Pelican can show this parameter as the odometer.
- Service 22
DID 2203 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer #2 RS5_MQB_TCM_ODO_2
Pelican can show this parameter as the odometer.
- Service 22
DID 3887 - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 429496729.5 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer #3 RS5_PQ35_ODO_3
Pelican can show this parameter as the odometer.
- Service 22
DID 101A - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer at oxidation catalytic converter replacement RS5_ODO_OXYDATION
- Service 22
DID 4F3F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2010 to 2026.
Odometer reading at fourth-to-last warning RS5_TPMS_ODO_RDG_AT_FOURTH_TO_LAST_WARN
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 232 to 263 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading at last adaptation RS5_TPMS_ODO_RDG_AT_LAST_ADAPT
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 8 to 39 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading at last warning RS5_TPMS_ODO_RDG_AT_LAST_WARN
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 136 to 167 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading at next-to-last warning RS5_TPMS_ODO_RDG_AT_NEXT_TO_LAST_WARN
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 168 to 199 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading at third-to-last warning RS5_TPMS_ODO_RDG_AT_THIRD_TO_LAST_WARN
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 200 to 231 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading four adaptations ago RS5_TPMS_ODO_RDG_FOUR_ADAPTATIONS_AGO
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 104 to 135 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading three adaptations ago RS5_TPMS_ODO_RDG_THREE_ADAPTATIONS_AGO
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 72 to 103 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer reading two adaptations ago RS5_TPMS_ODO_RDG_TWO_ADAPTATIONS_AGO
- Service 22
DID 1821 - Module
713 → 77D - Every
5 s - Testing
Bits 40 to 71 of the reply, 32 bits.
- Formula
- Range
- 0 to 200000 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Odometer with ECU installed RS5_ODO_ECU_INSTALLED
- Service 22
DID 295B - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 m
- Unit
- m
In testing for 2010 to 2026.
Odometer, alternate RS5_PQ35_ODO_2
Pelican can show this parameter as the odometer.
- Service 22
DID 16A9 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2010 to 2026.
Odometer, high resolution RS5_ODO_HDConfirmed
Pelican can show this parameter as the odometer.
- Service 22
DID 1160 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967295 m
- Unit
- m
0x0626A69C = 103196316 → 103,196,316 m
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Odometer, mileage, HR RS5_ODO_MILEAGE_HR
- Service 22
DID 22B8 - Module
714 → 77E - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2010 to 2026.
Operating time, temperature range 1 RS5_OP_TIME_T_RANGE_1
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Operating time, temperature range 2 RS5_OP_TIME_T_RANGE_2
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Operating time, temperature range 3 RS5_OP_TIME_T_RANGE_3
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 64 to 95 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Operating time, temperature range 4 RS5_OP_TIME_T_RANGE_4
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 127 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Operating time, temperature range 5 RS5_OP_TIME_T_RANGE_5
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 159 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Operating time, temperature range 6 RS5_OP_TIME_T_RANGE_6
- Service 22
DID 1111 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 160 to 191 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
- Range
- 0 to 23860.7 h
- Unit
- h
In testing for 2010 to 2026.
Range remaining RS5_RANGE_V2Confirmed
- Service 22
DID 2AB6 - Module
710 → 77A - Every
5 s - Testing for 2010 to 2018, 2020 to 2026
Example reply from a 2019 Audi RS 5.
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 mi
- Unit
- mi
0x003C = 60 → 60 mi
Confirmed for 2019. In testing for 2010 to 2018, 2020 to 2026.
Range remaining, displayed RS5_RANGE_DSP
- Service 22
DID 22E0 - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2018, 2020 to 2026. Not supported for 2019.
Remaining distance until reducing agent deficiency RS5_REMAINING_DIST_UNTIL
- Service 22
DID 29B1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
- Range
- 0 to 214748364 km
- Unit
- km
In testing for 2010 to 2026.
Torque converter time in temperature range 1 RS5_TQ_CONV_TIME_T_RANGE_1
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 2 RS5_TQ_CONV_TIME_T_RANGE_2
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 3 RS5_TQ_CONV_TIME_T_RANGE_3
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 4 RS5_TQ_CONV_TIME_T_RANGE_4
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 95 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 5 RS5_TQ_CONV_TIME_T_RANGE_5
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 96 to 119 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 6 RS5_TQ_CONV_TIME_T_RANGE_6
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 120 to 143 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 7 RS5_TQ_CONV_TIME_T_RANGE_7
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 144 to 167 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Torque converter time in temperature range 8 RS5_TQ_CONV_TIME_T_RANGE_8
- Service 22
DID 17FC - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 168 to 191 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 min
- Unit
- min
In testing for 2010 to 2026.
Trip consumption, short RS5_TRIP_USE_SHORT
- Service 22
DID 0530 - Module
714 → 77E - Every
500 ms - Testing
Bits 238 to 255 of the reply, 18 bits. The value is signed.
- Formula
- Range
- -131 to 131 kWh/100 mi
- Unit
- kWh/100 mi
In testing for 2010 to 2026.