Parameters
The Acura ILX has 321 parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery
Battery coolant temperature ILX_BATTERY_COOLANT_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Battery module power ILX_BATTERY_MODULE_POWER
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -524.288 to 524.272 kW
- Unit
- kW
In testing for 2013 to 2022.
Cell voltage limit during charge ILX_CEL_V_LIM
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Charging voltage target ILX_CHG_V_TGT
- Service 22
DID 2029 - Module
DA15 → 15 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2016. Supported for 2013, 2015.
Distance traveled since last charge ILX_BAT_DIST
- Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing
Bits 80 to 111 of the reply, 32 bits.
- Formula
- Range
- 0 to 250000 km
- Unit
- km
In testing for 2013 to 2022.
High voltage battery cells, max state of charge ILX_CELL_MAX_SOC
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
High voltage battery cells, max state of charge ILX_CELL_MIN_SOC
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
High voltage battery module 1A temperature ILX_HVB_MOD_1A_T
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery module 1B temperature ILX_HVB_MOD_1B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 472 to 487 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery module 2A temperature ILX_HVB_MOD_2A_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 488 to 503 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery module 3A temperature ILX_HVB_MOD_3A_T
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery module 3B temperature ILX_HVB_MOD_3B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 504 to 519 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery module 4B temperature ILX_HVB_MOD_4B_T
- Service 22
DID 202C - Module
DA16 → 16 - Every
5 s - Testing
Bits 520 to 535 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
High voltage battery total capacity ILX_HVB_CAP
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2013 to 2022.
High voltage battery total current ILX_HVB_C_TOTAL
Pelican can show this parameter as the traction battery current.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -100 to 200 A
- Unit
- A
In testing for 2013 to 2022.
High voltage battery voltage ILX_HVB_V
Pelican can show this parameter as the traction battery voltage.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
In testing for 2013 to 2022.
High voltage battery voltage, line b ILX_HVB_V_B
Pelican can show this parameter as the starter battery voltage.
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 400 V
- Unit
- V
In testing for 2013 to 2022.
HV battery cell max state of charge ILX_HV_BATTERY_CELL_MAX_STATE_OF_CHARGE
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2013 to 2022.
HV battery current ILX_HV_BATTERY_CURRENT
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2013 to 2022.
HV battery fan 3 speed ILX_HV_BATTERY_FAN_3_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
- Range
- 0 to 25500 rpm
- Unit
- rpm
In testing for 2013 to 2022.
HV battery max cell voltage ILX_HV_BATTERY_MAX_CELL_VOLTAGE
- Service 22
DID 2222 - Module
DBEF - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2013 to 2022.
HV battery usable capacity ILX_HV_BATTERY_USABLE_CAPACITY
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
Normal charger input voltage ILX_CHG_V_IN
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2013 to 2022.
Normal charger output voltage ILX_CHG_V_OUT
- Service 22
DID 2021 - Module
DA15 → 15 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 500 V
- Unit
- V
In testing for 2013 to 2022.
State of charge ILX_SOC
Pelican can show this parameter as the state of charge.
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
State of charge ILX_STATE_OF_CHARGE
- Service 22
DID 2012 - Module
DBEF - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
Cells
Battery capacity, line b ILX_HVB_CAP_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2013 to 2022.
Cell voltage, 1 ILX_CEL_V_B1
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 2 ILX_CEL_V_B2
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 3 ILX_CEL_V_B3
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 4 ILX_CEL_V_B4
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 5 ILX_CEL_V_B5
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 6 ILX_CEL_V_B6
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 7 ILX_CEL_V_B7
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 8 ILX_CEL_V_B8
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 9 ILX_CEL_V_B9
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 10 ILX_CEL_V_B10
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 11 ILX_CEL_V_B11
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 12 ILX_CEL_V_B12
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 13 ILX_CEL_V_B13
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 14 ILX_CEL_V_B14
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 15 ILX_CEL_V_B15
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 16 ILX_CEL_V_B16
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 17 ILX_CEL_V_B17
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 18 ILX_CEL_V_B18
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 19 ILX_CEL_V_B19
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 20 ILX_CEL_V_B20
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 21 ILX_CEL_V_B21
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 22 ILX_CEL_V_B22
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 23 ILX_CEL_V_B23
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 24 ILX_CEL_V_B24
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 25 ILX_CEL_V_B25
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 26 ILX_CEL_V_B26
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 27 ILX_CEL_V_B27
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 28 ILX_CEL_V_B28
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 29 ILX_CEL_V_B29
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 30 ILX_CEL_V_B30
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 31 ILX_CEL_V_B31
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 32 ILX_CEL_V_B32
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 33 ILX_CEL_V_B33
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 34 ILX_CEL_V_B34
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 35 ILX_CEL_V_B35
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 36 ILX_CEL_V_B36
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 37 ILX_CEL_V_B37
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 38 ILX_CEL_V_B38
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 39 ILX_CEL_V_B39
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 40 ILX_CEL_V_B40
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 41 ILX_CEL_V_B41
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 42 ILX_CEL_V_B42
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 43 ILX_CEL_V_B43
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 44 ILX_CEL_V_B44
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 45 ILX_CEL_V_B45
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 46 ILX_CEL_V_B46
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 47 ILX_CEL_V_B47
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 48 ILX_CEL_V_B48
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 49 ILX_CEL_V_B49
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 50 ILX_CEL_V_B50
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 51 ILX_CEL_V_B51
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 52 ILX_CEL_V_B52
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 53 ILX_CEL_V_B53
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 54 ILX_CEL_V_B54
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 55 ILX_CEL_V_B55
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 56 ILX_CEL_V_B56
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 57 ILX_CEL_V_B57
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 58 ILX_CEL_V_B58
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 59 ILX_CEL_V_B59
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 60 ILX_CEL_V_B60
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 61 ILX_CEL_V_B61
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 62 ILX_CEL_V_B62
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 63 ILX_CEL_V_B63
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 64 ILX_CEL_V_B64
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 65 ILX_CEL_V_B65
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 66 ILX_CEL_V_B66
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 67 ILX_CEL_V_B67
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 68 ILX_CEL_V_B68
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 69 ILX_CEL_V_B69
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 70 ILX_CEL_V_B70
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 71 ILX_CEL_V_B71
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 72 ILX_CEL_V_B72
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 73 ILX_CEL_V_B73
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 74 ILX_CEL_V_B74
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 75 ILX_CEL_V_B75
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 76 ILX_CEL_V_B76
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 77 ILX_CEL_V_B77
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 78 ILX_CEL_V_B78
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 79 ILX_CEL_V_B79
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 80 ILX_CEL_V_B80
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 81 ILX_CEL_V_B81
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 82 ILX_CEL_V_B82
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 83 ILX_CEL_V_B83
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Cell voltage, 84 ILX_CEL_V_B84
- Service 22
DID 2028 - Module
DA16 → 16 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell max SOC, line b ILX_CEL_MAX_SOC_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
Individual cell min SOC, line b ILX_CEL_MIN_SOC_B
- Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
Individual cell voltage A1 ILX_CEL_V_A1
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A2 ILX_CEL_V_A2
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A3 ILX_CEL_V_A3
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A4 ILX_CEL_V_A4
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A5 ILX_CEL_V_A5
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A6 ILX_CEL_V_A6
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A7 ILX_CEL_V_A7
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A8 ILX_CEL_V_A8
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A9 ILX_CEL_V_A9
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A10 ILX_CEL_V_A10
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A11 ILX_CEL_V_A11
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A12 ILX_CEL_V_A12
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A13 ILX_CEL_V_A13
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A14 ILX_CEL_V_A14
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A15 ILX_CEL_V_A15
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A16 ILX_CEL_V_A16
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A17 ILX_CEL_V_A17
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 472 to 487 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A18 ILX_CEL_V_A18
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A19 ILX_CEL_V_A19
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 504 to 519 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A20 ILX_CEL_V_A20
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 520 to 535 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A21 ILX_CEL_V_A21
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 536 to 551 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A22 ILX_CEL_V_A22
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 552 to 567 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A23 ILX_CEL_V_A23
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 568 to 583 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A24 ILX_CEL_V_A24
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 584 to 599 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A25 ILX_CEL_V_A25
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 600 to 615 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A26 ILX_CEL_V_A26
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 616 to 631 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A27 ILX_CEL_V_A27
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 632 to 647 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A28 ILX_CEL_V_A28
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 648 to 663 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A29 ILX_CEL_V_A29
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 664 to 679 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A30 ILX_CEL_V_A30
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 680 to 695 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A31 ILX_CEL_V_A31
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 696 to 711 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A32 ILX_CEL_V_A32
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 712 to 727 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A33 ILX_CEL_V_A33
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 728 to 743 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A34 ILX_CEL_V_A34
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 744 to 759 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A35 ILX_CEL_V_A35
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 760 to 775 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A36 ILX_CEL_V_A36
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 776 to 791 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A37 ILX_CEL_V_A37
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 792 to 807 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A38 ILX_CEL_V_A38
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 808 to 823 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A39 ILX_CEL_V_A39
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 824 to 839 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A40 ILX_CEL_V_A40
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 855 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A41 ILX_CEL_V_A41
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 856 to 871 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A42 ILX_CEL_V_A42
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 872 to 887 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A43 ILX_CEL_V_A43
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 888 to 903 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A44 ILX_CEL_V_A44
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 904 to 919 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A45 ILX_CEL_V_A45
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 920 to 935 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A46 ILX_CEL_V_A46
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 936 to 951 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A47 ILX_CEL_V_A47
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 952 to 967 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A48 ILX_CEL_V_A48
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 968 to 983 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A49 ILX_CEL_V_A49
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 984 to 999 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A50 ILX_CEL_V_A50
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,000 to 1,015 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A51 ILX_CEL_V_A51
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,016 to 1,031 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A52 ILX_CEL_V_A52
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,032 to 1,047 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A53 ILX_CEL_V_A53
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,048 to 1,063 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A54 ILX_CEL_V_A54
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,064 to 1,079 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A55 ILX_CEL_V_A55
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,080 to 1,095 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A56 ILX_CEL_V_A56
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,096 to 1,111 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A57 ILX_CEL_V_A57
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,112 to 1,127 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A58 ILX_CEL_V_A58
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,128 to 1,143 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A59 ILX_CEL_V_A59
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,144 to 1,159 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A60 ILX_CEL_V_A60
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,160 to 1,175 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A61 ILX_CEL_V_A61
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,176 to 1,191 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A62 ILX_CEL_V_A62
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,192 to 1,207 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A63 ILX_CEL_V_A63
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,208 to 1,223 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A64 ILX_CEL_V_A64
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,224 to 1,239 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A65 ILX_CEL_V_A65
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,240 to 1,255 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A66 ILX_CEL_V_A66
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,256 to 1,271 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A67 ILX_CEL_V_A67
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,272 to 1,287 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A68 ILX_CEL_V_A68
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,288 to 1,303 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A69 ILX_CEL_V_A69
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,304 to 1,319 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A70 ILX_CEL_V_A70
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,320 to 1,335 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A71 ILX_CEL_V_A71
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,336 to 1,351 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A72 ILX_CEL_V_A72
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,352 to 1,367 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A73 ILX_CEL_V_A73
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,368 to 1,383 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A74 ILX_CEL_V_A74
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,384 to 1,399 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A75 ILX_CEL_V_A75
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,400 to 1,415 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A76 ILX_CEL_V_A76
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,416 to 1,431 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A77 ILX_CEL_V_A77
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,432 to 1,447 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A78 ILX_CEL_V_A78
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,448 to 1,463 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A79 ILX_CEL_V_A79
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,464 to 1,479 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A80 ILX_CEL_V_A80
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,480 to 1,495 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A81 ILX_CEL_V_A81
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,496 to 1,511 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A82 ILX_CEL_V_A82
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,512 to 1,527 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A83 ILX_CEL_V_A83
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,528 to 1,543 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Individual cell voltage A84 ILX_CEL_V_A84
- Service 22
DID 2028 - Module
DA01 → 01 - Every
1 s - Testing
Bits 1,544 to 1,559 of the reply, 16 bits.
- Formula
- Range
- 0 to 5000 mV
- Unit
- mV
In testing for 2013 to 2022.
Climate
A/C pressure ILX_AC_P
- Service 22
DID 2613 - Module
DA0E → 0E - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
- Range
- 0 to 4000 kPa
- Unit
- kPa
In testing for 2013 to 2022.
Outside air temperature ILX_AATConfirmed
- Service 22
DID 7028 - Module
DA60 → 60 - Every
5 s - Testing for 2013 to 2014, 2017 to 2022
Bits 132 to 143 of the reply, 12 bits. The value is signed.
- Formula
- Range
- -40 to 2047 °F
- Unit
- °F
Confirmed for 2015 to 2016. In testing for 2013 to 2014, 2017 to 2022.
Clocks
Time since engine start ILX_RUNTM_PCM
How long it's been since the engine started.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 s
- Unit
- s
In testing for 2013 to 2022.
Control
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
DTCs
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2016. Supported for 2013, 2015.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2016. Supported for 2013, 2015.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2016. Supported for 2013, 2015.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
- Range
- 0 to 127
- Unit
- Number
Confirmed for 2016. Supported for 2013, 2015.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
Confirmed for 2016. Supported for 2013, 2015.
Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2016. Supported for 2013, 2015.
Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2016. Supported for 2013, 2015.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2016. Supported for 2013, 2015.
ECU
Knock control ILX_KNOCK_CTRL_PCM
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 2
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 1 ILX_MIS_1_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 2 ILX_MIS_2_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 3 ILX_MIS_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 4 ILX_MIS_4_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 5 ILX_MIS_5_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count, cylinder 6 ILX_MIS_6_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Electrical
Brake fluid pressure ILX_BRK_FLD_P
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
- Range
- 0 to 5
- Unit
- Raw value
In testing for 2013 to 2022.
Brake pedal stroke ILX_BRK_PED_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
- Range
- 0 to 50 mm
- Unit
- mm
In testing for 2013 to 2022.
Brake pressure ILX_BRK_P
- Service 22
DID 4005 - Module
DA28 → 28 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
- Range
- 0 to 120 bar
- Unit
- bar
In testing for 2013 to 2022.
Brake switch ILX_BRK_SW
- Service 22
DID 4004 - Module
DA28 → 28 - Every
1 s - Testing
Bit 127 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2013 to 2022.
Master cylinder stroke ILX_MSTR_CYL_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 mm
- Unit
- mm
In testing for 2013 to 2022.
Slave cylinder stroke ILX_SLV_CYL_STK
- Service 22
DID 4201 - Module
DA2A → 2A - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
- Range
- 0 to 6553.5 mm
- Unit
- mm
In testing for 2013 to 2022.
Engine
A/C clutch ILX_AC_CLU_PCM
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bit 262 of the reply.
- Formula
- Range
- 0 to 1
- Unit
- Off or on
In testing for 2013 to 2022.
Absolute load value LOAD_ABSSAE J1979Confirmed
Pelican can show this parameter as the absolute engine load.
- Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Active cylinders ILX_ACTIVE_CYL_PCM
- Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
- Range
- 0 to 6
- Unit
- Number
In testing for 2013 to 2022.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2016. Supported for 2013, 2015.
Air/gas ratio ILX_AIRGAS_RAT_PCM
- Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2013 to 2022.
Ambient air temperature, cabin ILX_AAT_CAB
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2013 to 2022.
Ambient air temperature, outside ILX_AAT_OUT
- Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2013 to 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2016. Supported for 2013, 2015.
Cabin air temperature ILX_CABIN_AIR_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2013 to 2022.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2016. Supported for 2013, 2015.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.
Pelican can show this parameter as the commanded lambda.
- Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2016. Supported for 2013, 2015.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
DC-DC converter temperature ILX_DC_DC_CONVERTER_TEMPERATURE
- Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016. Supported for 2013, 2015.
Engine coolant temperature sensor 1 ILX_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine coolant temperature sensor 2 ILX_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine coolant temperature sensor 3 ILX_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine coolant temperature sensor 4 ILX_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine oil temperature, variant 3 ILX_EOT_VAR_3_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine oil temperature, variant 4 ILX_EOT_VAR_4_PCM
- Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2013 to 2022.
Engine RPM RPMSAE J1979Confirmed
Pelican can show this parameter as the engine speed.
- Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2016. Supported for 2013, 2015.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2016. Supported for 2013, 2015.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2016.
Fuel/air commanded equivalence ratio ILX_FUELAIR_CAR_PCM
- Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 29.4
- Unit
- Number
In testing for 2013 to 2022.
Generator ILX_GENERATOR_PCM
- Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
Intake air temperature IATSAE J1979Confirmed
- Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2016. Supported for 2013, 2015.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2016. Supported for 2013, 2015.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Maintenance, air cleaner ILX_MAINT_AIR_CLN
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, cabin filter ILX_MAINT_CABIN_FLT
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, engine coolant ILX_MAINT_COOL
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, general inspection ILX_MAINT_INSP
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, oil & filter ILX_MAINT_OIL_FLT
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, rake fluid ILX_MAINT_BRK_FLD
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, spark plugs & valves ILX_MAINT_SPARK
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Maintenance, transmission fluid ILX_MAINT_TRANS_FLD
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Misfire count #1, variant 1 ILX_MIS_CNT_1_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #1, variant 3 ILX_MIS_CNT_1_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #2, variant 1 ILX_MIS_CNT_2_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #2, variant 3 ILX_MIS_CNT_2_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #3, variant 1 ILX_MIS_CNT_3_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #3, variant 3 ILX_MIS_CNT_3_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #4, variant 1 ILX_MIS_CNT_4_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #4, variant 3 ILX_MIS_CNT_4_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #5, variant 1 ILX_MIS_CNT_5_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #5, variant 3 ILX_MIS_CNT_5_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #6, variant 1 ILX_MIS_CNT_6_VAR_1_PCM
- Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Misfire count #6, variant 3 ILX_MIS_CNT_6_VAR_3_PCM
- Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535
- Unit
- Number
In testing for 2013 to 2022.
Motor inverter, current ILX_MOTOR_INVERTER_CURRENT
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2013 to 2022.
Outside air temperature ILX_OUTSIDE_AIR_TEMPERATURE
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2013 to 2022.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2016. Supported for 2013, 2015.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2016. Supported for 2013, 2015.
Variable valve timing duty ILX_VTC_DUTY_PCM
- Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
In testing for 2013 to 2022.
OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2016. Supported for 2015.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2016. Supported for 2015.
Fuel
Air-fuel mixture heater ILX_AIR_FUEL_MIXTURE
- Service 22
DID 266D - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
- Range
- 0 to 127 %
- Unit
- %
In testing for 2013 to 2022.
Fuel level ILX_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing for 2013 to 2014, 2017 to 2022
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 655 L
- Unit
- L
Confirmed for 2015 to 2016. In testing for 2013 to 2014, 2017 to 2022.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2016. Supported for 2013, 2015.
Movement
Generator motor speed ILX_GENERATOR_MOTOR_SPEED
- Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
- Range
- 0 to 16320 rpm
- Unit
- rpm
In testing for 2013 to 2022.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2016. Supported for 2013, 2015.
OBD
OBD requirements to which vehicle is designed OBDSUPSAE J1979Confirmed
- Service 01
PID 1C - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | OBD II | OBD II (California ARB) |
2 | OBD | OBD (Federal EPA) |
3 | OBD & OBD II | |
4 | OBD I | |
5 | NO OBD | Not OBD compliant |
6 | EOBD | |
7 | EOBD & OBD II | |
8 | EOBD & OBD | |
9 | EOBD, OBD, OBD II | |
10 | JOBD | |
11 | JOBD & OBD II | |
12 | JOBD & EOBD | |
13 | JOBD, EOBD, OBD II | |
14 | EURO IV B1 | Heavy duty vehicles (EURO IV) B1 |
15 | EURO V B2 | Heavy duty vehicles (EURO V) B2 |
16 | EURO C | Heavy duty vehicles (EURO EEC) C (gas engines) |
17 | EMD | Engine manufacturer diagnostics (EMD) |
18 | EMD+ | Engine Manufacturer Diagnostics Enhanced (EMD+) |
19 | HD OBD-C | Heavy Duty On-Board Diagnostics (Child/Partial) |
20 | HD OBD | Heavy Duty On-Board Diagnostics |
21 | WWH OBD | World Wide Harmonized OBD |
23 | HD EOBD-I | Heavy Duty Euro OBD Stage I without NOx Control |
24 | HD EOBD-I N | Heavy Duty Euro OBD Stage I with NOx Control |
25 | HD EOBD-II | Heavy Duty Euro OBD Stage II without NOx Control |
26 | HD EOBD-II N | Heavy Duty Euro OBD Stage II with NOx Control |
27 | HD-ZEV | Heavy Duty ZEV |
28 | OBDBr-1 | Brazil OBD Phase 1 |
29 | OBDBr-2 | Brazil OBD Phase 2 and Phase 2+ |
30 | KOBD | Korean OBD |
31 | IOBD-I-BS4 | India BS4 OBD I |
32 | IOBD-II-BS4 | India BS4 OBD II |
33 | HD EOBD-VI | Euro VI |
34 | OBD, OBD II and HD OBD | |
35 | OBDBr-3 | Brazil OBD Phase 3 |
36 | MC EOBD-I | Motorcycle, Euro OBD-I |
37 | MC EOBD-II | Motorcycle, Euro OBD-II |
38 | MC COBD-I | Motorcycle, China OBD-I |
39 | MC TOBD-I | Motorcycle, Taiwan OBD-I |
40 | MC JOBD-I | Motorcycle, Japan OBD-I |
41 | CN-OBD-6 | China Nationwide Stage 6 |
42 | OBDBr-P7 | Brazil OBD Phase 7 |
43 | CN-HDOBD-VI | China Heavy Duty VI |
44 | IOBD-I-BS6 | India BS6 OBD I |
45 | IOBD-II-BS6 | India BS6 OBD II |
46 | IHDOBD-BSVI | India BSVI HD OBD |
47 | OBDBr-P8 | Brazil OBD Phase 8 |
48 | HD-JOBD-II | Japan Heavy Duty OBD-II |
49 | HD-KOBD-II | Korea Heavy Duty OBD-II |
50 | CN-OROBD-IV | China Off-Road IV OBD |
51 | CARB ACC-II | Light Duty ZEV, ACC-II |
52 | MC JOBD-II | Motorcycle, Japan OBD-II |
53 | MC CARB OBD | Motorcycle, California (CARB) OBD |
54 | MC EPA OBD | Motorcycle, Federal (EPA) OBD |
55 | MC CARB & EPA OBD | Motorcycle, 50-State (CARB & EPA) OBD |
56 | HD ZEV CARB ZEP | Heavy Duty ZEV, CARB ZEP |
57 | CARB ACC-II & EPA TIER4 | Light Duty ZEV, CARB ACC-II and EPA Tier 4 (GTR 22) |
58 | EPA TIER4 | Light Duty ZEV, EPA Tier 4 (GTR 22) |
59 | EPA HD | EPA HD OBD |
Confirmed for 2016. Supported for 2013, 2015.
Tires
Front left tire pressure ILX_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 80 to 95 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Front left tire temperature ILX_TT_FLConfirmed
Pelican can show this parameter as the front left tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 200 to 207 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Front right tire pressure ILX_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 64 to 79 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Front right tire temperature ILX_TT_FRConfirmed
Pelican can show this parameter as the front right tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Maintenance, tire rotation ILX_MAINT_TIRE
- Service 22
DID 7060 - Module
DA60 → 60 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2013 to 2022.
Rear left tire pressure ILX_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 112 to 127 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Rear left tire temperature ILX_TT_RLConfirmed
Pelican can show this parameter as the rear left tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Rear right tire pressure ILX_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 96 to 111 of the reply, 16 bits.
- Formula
- Range
- 0 to 65535 kPa
- Unit
- kPa
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Rear right tire temperature ILX_TT_RRConfirmed
Pelican can show this parameter as the rear right tire temperature.
- Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing for 2013 to 2015, 2017 to 2022
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2016. In testing for 2013 to 2014, 2017 to 2022. Not supported for 2015.
Transmission
Current gear var.2 ILX_CURRENT_GEAR_VAR_2
- Service 22
DID 2612 - Module
DA0E → 0E - Every
1 s - Testing
Bits 352 to 359 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Current gear var.3 ILX_CURRENT_GEAR_VAR_3
- Service 22
DID 2612 - Module
DA0E → 0E - Every
1 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
- Range
- 0 to 255
- Unit
- Number
In testing for 2013 to 2022.
Trips
Odometer ILX_ODO_PCM
Pelican can show this parameter as the odometer.
- Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2013 to 2022.
Odometer, variation 3 ILX_ODO_V3
- Service 22
DID 7022 - Module
DA60 → 60 - Every
30 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
- Range
- 0 to 200000 mi
- Unit
- mi
In testing for 2013 to 2022.