Acura CSX

Parameters

The Acura CSX has 188 parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Control module voltage VPWRConfirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2007. Supported for 2008.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val1000
Range
0 to 65.535 V
Unit
V

Confirmed for 2007. Supported for 2008.

Distance traveled since last charge CSX_BAT_DIST

  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

In testing for 2006 to 2011.

High voltage battery cells, max state of charge CSX_CELL_MAX_SOC

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

High voltage battery cells, max state of charge CSX_CELL_MIN_SOC

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val100
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

High voltage battery module 1A temperature CSX_HVB_MOD_1A_T

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

High voltage battery module 3A temperature CSX_HVB_MOD_3A_T

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

High voltage battery total capacity CSX_HVB_CAP

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2006 to 2011.

High voltage battery total current CSX_HVB_C_TOTAL

Pelican can show this parameter as the traction battery current.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
val50
Range
-100 to 200 A
Unit
A

In testing for 2006 to 2011.

High voltage battery voltage CSX_HVB_V

Pelican can show this parameter as the traction battery voltage.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val20
Range
0 to 400 V
Unit
V

In testing for 2006 to 2011.

State of charge CSX_SOC

Pelican can show this parameter as the state of charge.

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

Cells

Individual cell voltage A1 CSX_CEL_V_A1

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A2 CSX_CEL_V_A2

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A3 CSX_CEL_V_A3

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A4 CSX_CEL_V_A4

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A5 CSX_CEL_V_A5

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A6 CSX_CEL_V_A6

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A7 CSX_CEL_V_A7

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A8 CSX_CEL_V_A8

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A9 CSX_CEL_V_A9

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A10 CSX_CEL_V_A10

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A11 CSX_CEL_V_A11

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A12 CSX_CEL_V_A12

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A13 CSX_CEL_V_A13

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A14 CSX_CEL_V_A14

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A15 CSX_CEL_V_A15

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A16 CSX_CEL_V_A16

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A17 CSX_CEL_V_A17

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A18 CSX_CEL_V_A18

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A19 CSX_CEL_V_A19

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A20 CSX_CEL_V_A20

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A21 CSX_CEL_V_A21

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A22 CSX_CEL_V_A22

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A23 CSX_CEL_V_A23

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A24 CSX_CEL_V_A24

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A25 CSX_CEL_V_A25

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A26 CSX_CEL_V_A26

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A27 CSX_CEL_V_A27

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A28 CSX_CEL_V_A28

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A29 CSX_CEL_V_A29

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A30 CSX_CEL_V_A30

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A31 CSX_CEL_V_A31

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A32 CSX_CEL_V_A32

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A33 CSX_CEL_V_A33

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A34 CSX_CEL_V_A34

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A35 CSX_CEL_V_A35

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A36 CSX_CEL_V_A36

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A37 CSX_CEL_V_A37

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A38 CSX_CEL_V_A38

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A39 CSX_CEL_V_A39

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A40 CSX_CEL_V_A40

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A41 CSX_CEL_V_A41

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A42 CSX_CEL_V_A42

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A43 CSX_CEL_V_A43

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A44 CSX_CEL_V_A44

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A45 CSX_CEL_V_A45

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A46 CSX_CEL_V_A46

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A47 CSX_CEL_V_A47

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A48 CSX_CEL_V_A48

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A49 CSX_CEL_V_A49

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A50 CSX_CEL_V_A50

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A51 CSX_CEL_V_A51

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A52 CSX_CEL_V_A52

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A53 CSX_CEL_V_A53

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A54 CSX_CEL_V_A54

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A55 CSX_CEL_V_A55

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A56 CSX_CEL_V_A56

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A57 CSX_CEL_V_A57

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A58 CSX_CEL_V_A58

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A59 CSX_CEL_V_A59

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A60 CSX_CEL_V_A60

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A61 CSX_CEL_V_A61

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A62 CSX_CEL_V_A62

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A63 CSX_CEL_V_A63

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A64 CSX_CEL_V_A64

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A65 CSX_CEL_V_A65

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A66 CSX_CEL_V_A66

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A67 CSX_CEL_V_A67

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A68 CSX_CEL_V_A68

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A69 CSX_CEL_V_A69

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A70 CSX_CEL_V_A70

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A71 CSX_CEL_V_A71

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A72 CSX_CEL_V_A72

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A73 CSX_CEL_V_A73

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A74 CSX_CEL_V_A74

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A75 CSX_CEL_V_A75

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A76 CSX_CEL_V_A76

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A77 CSX_CEL_V_A77

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A78 CSX_CEL_V_A78

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A79 CSX_CEL_V_A79

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A80 CSX_CEL_V_A80

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A81 CSX_CEL_V_A81

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A82 CSX_CEL_V_A82

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A83 CSX_CEL_V_A83

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Individual cell voltage A84 CSX_CEL_V_A84

  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
val5
Range
0 to 5000 mV
Unit
mV

In testing for 2006 to 2011.

Climate

A/C pressure CSX_AC_P

  • Service 22DID 2613
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 4000 kPa
Unit
kPa

In testing for 2006 to 2011.

Clocks

Time since engine start CSX_RUNTM_PCM

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2006 to 2011.

Time since engine start CSX_RUNTM_V2Confirmed

How long it's been since the engine started.

  • Service 22DID 2660
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2006, 2008 to 2011

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Control

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007. Supported for 2008.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007. Supported for 2008.

DTCs

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2007. Supported for 2008.

ECU

Knock control CSX_KNOCK_CTRL_PCM

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val×2255
Range
0 to 2
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 1 CSX_MIS_1_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 2 CSX_MIS_2_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 3 CSX_MIS_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 4 CSX_MIS_4_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 5 CSX_MIS_5_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count, cylinder 6 CSX_MIS_6_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Electrical

Brake fluid pressure CSX_BRK_FLD_P

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val100
Range
0 to 5
Unit
Raw value

In testing for 2006 to 2011.

Brake pedal stroke CSX_BRK_PED_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val10
Range
0 to 50 mm
Unit
mm

In testing for 2006 to 2011.

Brake pressure CSX_BRK_P

  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val−25
Range
0 to 120 bar
Unit
bar

In testing for 2006 to 2011.

Brake switch CSX_BRK_SW

  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2011.

Master cylinder stroke CSX_MSTR_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-3276.8 to 3276.7 mm
Unit
mm

In testing for 2006 to 2011.

Slave cylinder stroke CSX_SLV_CYL_STK

  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val10
Range
0 to 6553.5 mm
Unit
mm

In testing for 2006 to 2011.

Engine

A/C clutch CSX_AC_CLU_PCM

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2011.

Active cylinders CSX_ACTIVE_CYL_PCM

  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 2006 to 2011.

Air conditioner clutch CSX_AC_CLU

  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2011.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val100
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2007. Supported for 2008.

Air/gas ratio CSX_AIRGAS_RAT_PCM

  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

In testing for 2006 to 2011.

Air/gas ratio CSX_AIRGAS_RATIO_V2Confirmed

  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2006, 2008 to 2011

Bits 64 to 79 of the reply, 16 bits.

Formula
val×29.465535
Range
0 to 29.4
Unit
Number

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Ambient air temperature, cabin CSX_AAT_CAB

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2006 to 2011.

Ambient air temperature, outside CSX_AAT_OUT

  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 2006 to 2011.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007. Supported for 2008.

Catalyst temperature CSX_CAT_TConfirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2006, 2008 to 2011

Bits 96 to 111 of the reply, 16 bits.

Formula
val10−40
Range
-40 to 1500 °C
Unit
°C

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Commanded fuel/air equivalence ratio (lambda): actual A/F ratio over stoichiometric A/F ratio, so above 1 is lean and below 1 is rich. Multiply by the fuel's stoichiometric A/F ratio for the commanded A/F ratio (gasoline: 14.64 x 0.95 = 13.9). Systems with conventional oxygen sensors show the commanded value in open loop and 1.000 in closed loop; systems with wide-range (linear) sensors show it in both. On engines whose banks are controlled independently, this is bank 1.

Pelican can show this parameter as the commanded lambda.

  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2007. Supported for 2008.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2007. Supported for 2008.

Engine coolant temperature sensor 1 CSX_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine coolant temperature sensor 2 CSX_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine coolant temperature sensor 3 CSX_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine coolant temperature sensor 4 CSX_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
val10
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine oil level CSX_ENG_OIL_LEVEL

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val2
Range
0 to 127.5 mm
Unit
mm

In testing for 2006 to 2011.

Engine oil temperature CSX_EOT

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine oil temperature, variant 3 CSX_EOT_VAR_3_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine oil temperature, variant 4 CSX_EOT_VAR_4_PCM

  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Engine oil temperature,, variant 2 CSX_EOT_VAR_2

  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

In testing for 2006 to 2011.

Fuel/air commanded equivalence ratio CSX_FUELAIR_CAR_PCM

  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val2229.081633
Range
0 to 29.4
Unit
Number

In testing for 2006 to 2011.

Generator CSX_GEN

  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

Generator CSX_GENERATOR_PCM

  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

Knock control CSX_KNOCK_CONTROL_V2Confirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2006, 2008 to 2011

Bits 80 to 87 of the reply, 8 bits.

Formula
val×1.99255
Range
0 to 1.99
Unit
Number

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Misfire count #1, variant 1 CSX_MIS_CNT_1_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #1, variant 3 CSX_MIS_CNT_1_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count #2, variant 1 CSX_MIS_CNT_2_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #2, variant 3 CSX_MIS_CNT_2_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count #3, variant 1 CSX_MIS_CNT_3_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #3, variant 3 CSX_MIS_CNT_3_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count #4, variant 1 CSX_MIS_CNT_4_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #4, variant 3 CSX_MIS_CNT_4_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count #5, variant 1 CSX_MIS_CNT_5_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #5, variant 3 CSX_MIS_CNT_5_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count #6, variant 1 CSX_MIS_CNT_6_VAR_1_PCM

  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count #6, variant 3 CSX_MIS_CNT_6_VAR_3_PCM

  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 1 CSX_MIS_CNT_1

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 1,, variant 1 CSX_MIS_CNT_1_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 1,, variant 2 CSX_MIS_CNT_1_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 1,, variant 3 CSX_MIS_CNT_1_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 2 CSX_MIS_CNT_2

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 2,, variant 1 CSX_MIS_CNT_2_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 2,, variant 2 CSX_MIS_CNT_2_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 2,, variant 3 CSX_MIS_CNT_2_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 3 CSX_MIS_CNT_3

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 3,, variant 1 CSX_MIS_CNT_3_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 3,, variant 2 CSX_MIS_CNT_3_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 3,, variant 3 CSX_MIS_CNT_3_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 4 CSX_MIS_CNT_4

  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 4,, variant 1 CSX_MIS_CNT_4_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 4,, variant 2 CSX_MIS_CNT_4_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 4,, variant 3 CSX_MIS_CNT_4_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 5,, variant 1 CSX_MIS_CNT_5_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 5,, variant 2 CSX_MIS_CNT_5_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 5,, variant 3 CSX_MIS_CNT_5_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 6,, variant 1 CSX_MIS_CNT_6_VAR_1

  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Misfire count 6,, variant 2 CSX_MIS_CNT_6_VAR_2

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Misfire count 6,, variant 3 CSX_MIS_CNT_6_VAR_3

  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2006 to 2011.

Oil pressure CSX_OIL_P

  • Service 22DID 2203
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2006, 2008 to 2011. Not supported for 2007.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100128−100
Range
-100 to 99.2 %
Unit
%

Confirmed for 2007. Supported for 2008.

Variable timing control duty CSX_VARIABLE_TIM_CTRLConfirmed

  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2006, 2008 to 2011

Bits 224 to 231 of the reply, 8 bits.

Formula
val×2051
Range
0 to 100 %
Unit
%

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Variable valve timing duty CSX_VTC_DUTY_PCM

  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

In testing for 2006 to 2011.

VTEC valve control CSX_VTEC_VALVE_CTRLConfirmed

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing for 2006, 2008 to 2011

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2007. In testing for 2006, 2008 to 2011.

OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
val32768
Range
0 to 1.99
Unit
Number

Confirmed for 2007.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
val256−128
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2007.

Fuel

Air-fuel mixture heater CSX_AIR_FUEL_MIXTURE

  • Service 22DID 266D
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val2
Range
0 to 127 %
Unit
%

In testing for 2006 to 2011.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val×100255
Range
0 to 100 %
Unit
%

Confirmed for 2007. Supported for 2008.

Movement

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2007. Supported for 2008.

Transmission

Automatic transmission fluid temperature CSX_ATF_TConfirmed

  • Service 22DID 2201
  • ModuleDA1D → 1D
  • Every1 s
  • Testing for 2006, 2008 to 2011

Bits 208 to 215 of the reply, 8 bits.

Formula
val−40
Range
-40 to 215 °C
Unit
°C

Confirmed for 2007. In testing for 2006, 2008 to 2011.

Current gear CSX_GEAR_1D

  • Service 22DID 2221
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Current gear, variant 2 CSX_CURRENT_GEAR_VAR_2

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bits 352 to 359 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Current gear, variant 3 CSX_CURRENT_GEAR_VAR_3

  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2011.

Trips

Odometer CSX_ODO_PCM

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006 to 2011.

Odometer CSX_ODO_V2

Pelican can show this parameter as the odometer.

  • Service 22DID 2660
  • ModuleDA1D → 1D
  • Every5 s
  • Testing

Bits 344 to 367 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2006, 2008 to 2011. Not supported for 2007.

Keyboard shortcuts

jkor↓↑
Move down or up through a list or a grid.
hlor←→
Move across a row or between cards.
Enter
Open the focused link.
for/
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.